THE ENCLOSED INST ALL ATION INSTRUCT I ONS AND ANY APPL ICABLE
LOCAL, STA T E , AND NAT IONAL CODES INCLUDING, BUT NOT LI MITED
TO, BUILDING, ELECTRICAL, AND MECHANICAL CODES.
THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH
WARNING
OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY
OR PROPERTY DAM AGE.
I NCORRECT INSTAL LATION MAY CREATE A CONDITION WHERE THE
SUNLINE™ SPLIT-SYSTEM
EVAPORATOR BLOWERS
(AIR COOLED)
INSTALLATION INSTRUCTION
MODELS K5EU090A50A & K4EU120A50A
Supersedes: Nothing550.39-N4YI (894)
035-12122
(WORLD 50 HZ)
GENERAL
These completely assembled blower units are manufactured under ISO 9002 Quality System Certification and
include a well-insulated cabinet, a DX cooling coil with
copper tubes and aluminum fins, an expansion valve, a
distributor, throwaway filters, a centrifugal blower, a
blower motor, a blower motor contactor, an adjustable
belt drive and a small holding charge of Refrigerant-22.
Blower motors and adjustable drives are factoryinstalled on all units.
The units are shipped in the vertical position with a vertical air
discharge. The blower section can be repositioned as shown in
Figure1 for horizontal applications.
REFERENCE
Additional information for the accessories on this equip
ment is available in the following instructions:
•
Electric Heater - 550.13-N10.1V
•
Supply Air Plenum - 550.13-N10.2V
•
Return Air Grille - 550.13-N10.3V
•
Base - 550.13-N10.4V
Installer should pay particular attention to the words: NOTE, CAUTION and WARNING. Notes
stallation easier. Cautions
are intended to clarify or make the in
are given to prevent equipment damage. Warnings are given to alert installer that personal injury
•
Hot Water & Steam Coil - 550.13-N10.7V
Renewal Parts:
•
Refer to Parts Manual for complete listing of replacement
parts on this equipment.
All forms may be ordered from:
Publications Distribution Center
Unitary Products Group
P.O. Box 1592, York, PA 17405
INSPECTION
As soon as a unit is received, it should be inspected for
possible damage during transit. If damage is evident, the
extent of the damage should be noted on the carrier's de
livery receipt. A separate request for inspection by the
6Typical Motor Mounting Assembly ....................... 7
7Pressure Drop Across Dry Coil vs Supply Air ...... 7
8Hole Locations (Pressure Drop Readings)........... 7
9Unit Dimensions and Clearances.........................10
10Typical Field Wiring (Cooling only).......................11
PRODUCT NOMENCLATURE
K4EU502A
PRODUCT CATEGORY
= Split-System Evaporator Blowerwith
Motor and Drive
PRODUCT GENERATION
4,5 = Design Level
PRODUCT IDENTIFIER
EU = Evaporator Blower Unit
2Unitary Products Group
10
NOMINAL COOLING
CAPACITY
090 = 90 Mbh (26.36kW)
120 = 120 Mbh (35.13kW)
VOLTAGE CODE
50 = 380/415-3-50
FACTORY INSTALLED HEAT
A = Not Applicable
INSTALLATION
carrier's agent should be made in writing. See Local Dis
tributor for additional information.
LIMITATIONS
These units must be installed in accordance with applicable na
tional, local and municipal safety codes.
If components are to be added to a unit to meet local codes,
they are to beinstalled atthe dealer'sand/or the customer's ex
pense. Refer to Table 1 for Unit Application Data.
LOCATION
These blower units are not designed for outdoor installation.
They must be locatedwithin the building structure, either inside
or outside the conditioned space.
These Evaporator Blower sections allow for vertical or horizon
tal installation in any area offering proper electrical supply, duct
TABLE 1 - UNIT APPLICATION DATA
They may be installed either with ductwork ormatching plenum
-
and inlet grille.
The unit should be located as close to the condensing unit as
practical and positioned to minimize bends in the refrigerant
piping.
Units being installed vertically or horizontally can be set directly
on a floor or platform, or they can be supported by metal or
wooden beams.
Units being installed horizontally can be suspended from
above. Four
frame to accommodate hanger rods. Knockouts must be re
3
" (9.5mm) weld nuts are provided in the unit
8
moved from the unit panels to expose these weld nuts. Refer to
Figure 1 for their location and the individual load on each
hanger rod.
WARNING: Be careful when attaching the hanger rods. They
* Utilization Range “A” in accordance with ARI Standard 110.
Power
Supply
Voltage
Variation*
Min.Max.Min.Max.Min.Max.Min.Max.
Supply Air Range
CFM/m
3
/s
Entering Air Temperature, °F(°C)
Cooling-db/wbHeating-db
and drain connections.
(66.7).
44-7/8 (1140)
(1251) 49-1/4
(35)
1-3/8
(25.7)
Model
KEU09026
KEU12026
Center of Gravity
Dimensions, (In./mm)
ABW1W2W3W4TOTAL
1
/ 66723
4
5
/ 67624
8
3
/ 60385 /38.593 / 42.270 / 3277 / 34.9325 / 147.4
4
1
/ 61385 /38.593 / 42.270 / 3280 / 36.2330 / 149.7
8
Weight Distribution
(lbs/kg)
FIG. 1 - UNIT SUSPENSION MOUNTING (Horizontal)
Unitary Products Group3
550.39-N4YI
CLEARANCES
The clearances listed on the unit dimension drawing
(Figure 9) are required for the proper service and opera
tion of the unit.
RIGGING AND HANDLING
Be careful when moving the unit. Do not remove any
packaging until the unit is near its final location.
The packaging consists of a bottom wooden skid that
can be lifted with a fork truck from any direction, a card
board container that covers the entire unit, and strapping
that secures the cardboard container to the bottom of the
skid.
These units can be rigged with slings under the bottom
skid.
-
-
CAUTION: Spreader bars should be used to prevent slings
from crushing the unit panels and frame.
Before rigging any unit, determine its weight from Ta
ble 2. Before rigging a unit for horizontal installation,
make sure that its weight will be distributed equally.
VERTICAL/HORIZONTAL INSTALLATION
The unit is shipped for vertical installation with a vertical
air discharge as shownin Figure 2, but maybe converted
for horizontal installation as shown in Figure 2 by interchanging the solid bottom panel and the return air duct
flange.
DUCT CONNECTIONS
All ducts should be designed and installed in accordance
with applicable national and/or local codes.
Refer to Figure 3 for suggested method of connecting
supply air ductwork.
-
FIG. 3 - SUPPLY AIR DUCT CONNECTION
Ducts should be sized no smaller than the duct flanges
on the unit or the accessory electric heater (if used). Ref
er to the unit dimensions (Figure 1) and the heater detail
(Figure 4) for these sizes.
Use flexible fiber glass or plastic cloth collars or other
non-flammable material at the unit duct connections to
minimize the transmission of noise and vibration.
Insulate all ductwork running through unconditioned areas to prevent moisture condensation and to provide
more economical operation.
The return air duct flange is factory-mounted on the front of the
unit, but it can be reversed with the solid bottom panel for hori
zontal applications. When the return air grille is used, the duct
connection frame is not used.
NOTE: If return air duct is not used, applicable lnstalltion
The field installed air plenum and return air grille accessories
should be used in place of ductwork only when a free blow/free
return application is practical.
codes may limit the unit to installation only in a single
story residence.
-
-
(489)
(565)
FIG. 2 - VERTICAL AND HORIZONTAL APPLICATION
4Unitary Products Group
FIG. 4 - ELECTRIC HEATER ACCESSORY
(25)