Page 1
TECHNICAL
TECHNICAL
GUIDE
GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
14 SEER – R-22
MODELS:
H*BE-F018 THRU 060
(1.5 THRU 5 NOMINAL TONS)
ISO 9001
Certified Quality
Management System
LISTED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
332018-BTG-D-0208
DESCRIPTION
The 14 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be custom-matched with one of UPG’s complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-On coils are availa ble for use
with upflow, downflow, or horizontal furnaces and air handlers.
WARRANTY
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed
of copper tube and aluminum fins.
• PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and desert sand matted-textured
finish insure less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connections.
Discharge line heat exchanger knockouts are provided, if
required. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and compressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant connections, a single panel covering the electrical controls,
and the molex plug in the control box connecting the condenser fan make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
Page 2
332018-BTG-D-0208
Physical and Electrical Data
MODEL HABE-F018S HDBE-F024S HCBE-F030S HABE-F036S HBBE-F042S HBBE-F048S HCBE-F060S
Unit Supply Voltage 208-230V, 1φ, 60Hz
Normal Voltage Range
1
Minimum Circuit Ampacity 8.5 10.5 16.9 18.1 17.8 20.6 33.5
Max. Overcurrent Device Amps
Min. Overcurrent Device Amps
2
3
15 15 25 25 30 35 50
15 15 20 20 20 25 35
Compressor Type Recip Recip Recip Scroll Scroll Scroll Scroll
Compressor Amps
Rated Load 6.4 8.0 12.8 13.5 13.2 15.5 25.6
Locked Rotor 36 40.5 68 73 95 109 150
Crankcase Heater No No No No No No No
Fan Motor Amps Rated Load 0.5 0.5 0.8 1.5 1.5 1.5 1.5
Fan Diameter Inches 22 22 22 22 24 24 24
Rated HP 1/15 1/15 1/8 1/4 1/4 1/4 1/4
Fan Motor
Nominal RPM 830 830 1075 850 850 850 850
Nominal CFM 2,100 2,000 2,800 3,300 3,300 3,300 3,600
Face Area Sq Ft 15.71 15.71 23.58 23.58 22.50 27.00 27.00
Coil
R o w s D e e p1111222
Fin /Inch 22 22 22 18 18 18 18
Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Vapor Line Set OD (Field Installed) 3/4 3/4 7/8 7/8 1 1/8 1 1/8 1 1/8
Unit Charge (Lbs - Oz)
4
5 - 9 6 - 0 8 - 2 9 - 14 14 - 15 15 - 5 16 - 5
Charge Per Foot, oz. 0.68 0.68 0.70 0.68 0.76 0.76 0.76
Operating Weight Lbs 170 181 193 219 240 264 279
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15
feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
187 to 252
All dimensions are in inches. They are subject to change
without notice. Certified dimensions will be provided upon
request.
C
Unit
Model
018 27 37 27
A
024 27 37 27
030 39 37 27
036 39 37 27
042 32 43 32
048 38 43 32
Dimensions
1
A
Refrigerant Connection
(Inches)
Service Valve Size
B C Liquid Vapor
3/8
3/4
7/8
1-1/8
060 38 43 32 7/8*
B
1. Included Fan Guard.
* Adapter fitting required for 1-1/8” line set.
2 Unitary Products Group
Page 3
332018-BTG-D-0208
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase
Outdoor Unit HABE-F018S HDBE-F024S HCBE-F030S HABE-F036S HBBE-F042S HBBE-F048S HCBE-F060S
Required TXV
Factory Charge, lbs-oz 5 - 9 6 - 0 8 - 2 9 - 14 14 - 15 15 - 5 16 - 5
1
1TVM2A1 1TVM2A1 1TVM2A1 1TVM702 1TVM703 1TVM703 1TVM2C1
Indoor Coil
F C / M C / P C 2 4 A 2 A 0––––––
F C / M C / P C 2 4 B 2 A 0––––––
F C / M C / P C 3 0 A 2 A 0––––––
F C / M C / P C 3 0 B 2 A 0––—–––
F C / M C / P C 3 2 A 2 A –0–––––
F C / M C / P C 3 5 B 2 A –0–––––
F C / M C / P C 3 5 C 2 A –0–––––
F C / M C / P C 3 6 A 2 A ––0––––
F C / M C / P C 3 6 B 2 A ––0––––
F C / M C / P C 3 6 C 2 A ––0––––
F C / P C 6 0 C 2 C ––––––0 *
F C / M C / P C 6 0 D 2 C ––––––0 *
M C 6 1 D 2 C ––––––0
F C / M C 6 2 D 2 C ––––––0
H C 3 0 A 2 A 0––––––
H C 3 6 B 2 A –00––––
H C 6 0 D 2 C ––––––0 *
H D 2 4 A 2 A –––––––
H D 3 6 B 2 A –00––––
H D 6 0 D 2 C ––––––0 *
U C 2 4 A 2 A 0––––––
U C 2 4 B 2 A 0––––––
U C 3 0 A 2 A 0––––––
U C 3 0 B 2 A 0––––––
U C 3 6 A 2 A ––0––––
U C 3 6 B 2 A ––0––––
U C 3 6 C 2 A ––0––––
U C 6 0 C 2 C ––––––0 *
U C 6 0 D 2 C ––––––0 *
A H P 2 4 B 2 A 0––––––
A H P 3 0 B 2 A –00––––
A H P / S H P 6 0 D 2 C ––––––0
A V 2 4 B 2 A 0––––––
A V 3 6 C 2 A –00––––
A V / S V 6 0 D 2 C ––––––0
F C / M C / P C 2 4 A 3 X 2 A + 0––––––
F C / M C / P C 2 4 B 3 X 2 A + 0––––––
F C / M C / P C 3 0 A 3 X 2 A + 0––––––
F C / M C / P C 3 0 B 3 X 2 A + 0––––––
F C / M C / P C 3 5 B 3 X –2 A + 0–––––
F C / M C / P C 3 5 C 3 X –2 A + 0–––––
F C / M C / P C 3 6 A 3 X ––2 A + 0––––
F C / M C / P C 3 6 B 3 X ––2 A + 0––––
F C / M C / P C 3 6 C 3 X ––2 A + 0––––
FC/MC/PC37C3X – – – 702 + 9 – – –
FC/MC/PC42B3X – – – 702 + 0 – – –
FC/MC/PC42X3X – – – 702 + 0 – – –
FC/MC/PC43B3X – – – 702 + 9 – – –
FC/MC/PC43C3X – – – 702 + 9 – – –
FC/MC/PC48C3X – – – 702 + 12 703 + 9* – –
For Notes See Page 4.
2,3
TXV4 + Charge Adder, Oz
Unitary Products Group 3
Page 4
332018-BTG-D-0208
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued)
Outdoor Unit HABE-F018S HDBE-F024S HCBE-F030S HABE-F036S HBBE-F042S HBBE-F048S HCBE-F060S
Required TXV
Factory Charge, lbs-oz 5 - 9 6 - 0 8 - 2 9 - 14 14 - 15 15 - 5 16 - 5
1
1TVM2A1 1TVM2A1 1TVM2A1 1TVM702 1TVM703 1TVM703 1TVM2C1
Indoor Coil
FC/MC/PC48D3X – – – 702 + 12 703 + 9* – –
F C / P C 6 0 C 3 X –––– 703 + 13 703 + 6* 2C + 0*
F C / M C / P C 6 0 D 3 X –––– 703 + 13 703 + 6* 2C + 0*
M C 6 1 D 3 X ––––– 703 + 13 2C + 0
F C / M C 6 2 D 3 X ––––– 703 + 13 2C + 0
H C 3 0 A 3 X 2 A + 0––––––
H C 3 6 B 3 X –2 A + 0 2 A + 0––––
HC42C3X – – – 702 + 9 703 + 6* – –
H C 6 0 D 3 X –––– 703 + 13 703 + 6* 2C + 0*
H D 2 4 A 3 X –––––––
HD36B3X – 2A + 0 2A + 0 702 + 5 – – –
H D 4 8 C 3 X –––– 703 + 0* 703 + 0* –
H D 6 0 D 3 X –––––– 2 C + 0 *
U C 2 4 A 3 X 2 A + 0––––––
U C 2 4 B 3 X 2 A + 0––––––
U C 3 0 A 3 X 2 A + 0––––––
U C 3 0 B 3 X 2 A + 0––––––
U C 3 6 A 3 X ––2 A + 0––––
U C 3 6 B 3 X ––2 A + 0––––
U C 3 6 C 3 X ––2 A + 0––––
UC42B3X – – – 702 + 0 – – –
UC42C3X – – – 702 + 0 – – –
UC48C3X – – – 702 + 12 703 + 9* – –
UC48D3X – – – 702 + 12 703 + 9* – –
U C 6 0 C 3 X –––– 703 + 13 703 + 6* 2C + 0*
U C 6 0 D 3 X –––– 703 + 13 703 + 6* 2C + 0*
A H P 2 4 B 3 X 2 A + 0––––––
A H P 3 0 B 3 X –2 A + 0 2 A + 0––––
AHP42C3X – – – 702 + 9 – – –
A H P / S H P 4 8 D 3 X –––– 703 + 13 703 + 6* –
AHP/SHP60D3X – – – 702 + 17 703 + 13 703 + 6 2C + 0
A V 2 4 B 3 X 2 A + 0––––––
AV36C3X – 2A + 0 2A + 0 702 + 9 – – –
A V / S V 4 8 D 3 X –––– 703 + 13 703 + 6 –
A V / S V 6 0 D 3 X –––– 703 + 13 703 + 6 2C + 0
F * F P 0 4 0 ––2 A + 0––––
F4FV060H06T2C ––––– 703 + 6 0
FOOTNOTES:
PROCEDURES:
2,3
1. A TXV kit must be used with these coils to obtain system performance.
2. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.
3. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
4. If no TXV is listed, the indoor coil has the correct valve factory installed.
* Does not achieve 14 SEER with PSC furnaces. For ratings, see technical guide or visit www.aridirectory.org/ari/unitary.html
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of
interconnecting line tubing.
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evaporator + adder for line set.
TXV4 + Charge Adder, Oz
4 Unitary Products Group
Page 5
332018-BTG-D-0208
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
MODEL W
COIL MODEL
1
RATED
CFM
TOTAL SENS.
1 PH 14 SEER AC WITH MA
HABE-F018S
MA08B 17 FC/MC24B 600 17.5 12.1 14.00 12.00
MA08B 17 FC/MC30B 600 17.5 12.1 14.00 12.00
HDBE-F024S MA08B 17 FC/MC35 B 800 23.0 16.6 14.00 12.00
HCBE-F030S MA12B 17 FC/MC36 B 1000 29.0 20.0 14.00 12.00
HABE-F036S
MA14D 24 FC/MC42D 1200 35.0 25.6 14.00 11.50
MA14D 24 FC/MC48D 1200 35.2 25.7 14.00 11.50
MA14D 24 FC/MC48D 1400 39.5 28.9 13.50 11.00
HBBE-F042S
MA14D 24 FC/MC60D 1400 40.5 29.6 14.00 11.50
MA16C 21 FC60C 1400 40.5 29.6 14.00 11.50
MA16C 21 FC/MC48C 1600 45.0 33.2 13.50 11.00
MA20D 24 FC/MC48D 1600 45.0 33.2 13.50 11.00
HBBE-F048S
MA16C 21 FC60C 1600 46.5 33.9 13.85 11.00
MA20D 24 FC/MC60D 1600 46.5 33.9 13.85 11.00
MA20D 24 MC61D 1600 47.0 34.3 14.00 11.50
MA20D 24 FC/MC60D 1800 55.0 38.5 14.00 12.00
HCBE-F060S
MA20D 24 MC61D 1800 55.5 38.9 14.00 11.50
MA20D 24 FC/MC62D 1800 55.5 38.9 14.00 11.50
1 PH 14 SEER AC WITH MV - VARIABLE SPEED
HABE-F018S
MV12B 17 FC/MC24B 600 17.8 12.1 15.00 12.00
MV12B 17 FC/MC30B 600 17.8 12.1 15.00 12.00
HDBE-F024S MV12B 17 FC/MC35 B 800 23.4 16.7 15.00 12.00
HCBE-F030S
HABE-F036S
HBBE-F042S
HBBE-F048S
MV12B 17 FC/MC36B 1000 29.4 19.9 15.00 12.00
MV16C 21 FC/MC36C 1000 29.4 19.9 15.00 12.00
MV16C 21 FC/MC42C 1250 35.2 25.6 15.00 12.00
MV16C 21 FC/MC48C 1285 36.0 25.7 15.00 12.00
MV16C 21 FC/MC48C 1420 40.5 28.9 14.50 12.00
MV20D 24 FC/MC60D 1420 41.5 29.6 15.00 12.00
MV20D 24 FC/MC48D 1590 46.0 33.2 14.50 12.00
MV20D 24 FC/MC60D 1600 47.0 33.9 14.65 12.00
MV20D 24 FC/MC60D 1800 55.0 37.5 14.25 12.00
HCBE-F060S
MV20D 24 MC61D 1800 55.5 37.9 14.25 12.00
MV20D 24 FC/MC62D 1800 55.5 37.9 14.25 12.00
1 PH 13 SEER AC WITH AV / SV / FV - VARIABLE SPEED
HABE-F018S AV24 17 – 600 17.8 12.1 15.00 12.00
HDBE-F024S AV36 21 – 800 23.4 16.7 15.00 12.00
HCBE-F030S AV36 21 – 1000 29.4 19.9 15.00 12.00
HABE-F036S AV36 21 – 1200 35.2 25.6 15.00 12.00
HBBE-F042S
AV/SV48 24 – 1400 40.5 29.0 15.00 12.00
AV/SV60 24 – 1400 40.5 29.0 15.00 12.00
AV/SV48 24 – 1600 46.5 33.2 15.00 12.00
HBBE-F048S
AV/SV60 24 – 1600 46.0 33.2 15.00 12.00
F*FV060 24 – 1625 46.5 34.9 15.00 12.50
HCBE-F060S
AV/SV60 24 – 1800 55.0 37.5 14.25 11.50
F*FV060 24 – 1850 55.0 39.2 14.10 11.50
1 PH 14 SEER AC WITH AHP / F*FP
HABE-F018S AHP24 17 – 655 18.0 12.7 15.00 12.00
HDBE-F024S AHP30 17 – 830 23.0 16.7 14.00 12.00
HCBE-F030S
HABE-F036S
HBBE-F042S
HBBE-F048S
AHP30 17 – 1015 29.6 24.0 14.00 12.00
F*FP040 21 – 1015 29.6 24.0 14.00 12.00
AHP36 21 – 1200 35.0 25.1 14.00 12.00
AHP42 21 – 1200 35.0 25.1 14.00 11.50
AHP/SHP48 24 – 1400 40.5 29.8 14.00 12.00
AHP/SHP60 24 – 1400 40.5 29.8 14.00 12.00
AHP/SHP48 24 – 1600 46.5 33.6 13.85 11.00
AHP/SHP60 24 – 1600 46.5 33.6 14.00 12.00
HCBE-F060S AHP/SHP60 24 – 1850 55.0 39.2 14.00 12.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80 °F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total ele ctric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
Go to www.ari.org/aridirectory for the latest additional matches.
Unitary Products Group 5
COOLING
NET MBH
SEER EER
Page 6
332018-BTG-D-0208
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
FURNACE
UNIT MODEL
HABE-F018S
HDBE-F024S
HCBE-F030S
HABE-F036S
HBBE-F042S
HBBE-F048S
HCBE-F060S
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
CFM RANGE
(MIN.-MAX.)
450
750
600
1000
800
1200
1000
1400
1200
1600
1400
1800
1600
2000
W
14,17 FC/MC/PC/UC24 600 17.5 12.1 14.00 12.00
14,17 FC/MC/PC/UC30 600 17.5 12.1 14.00 12.00
14 HC30 600 17.3 12.1 14.00 12.00
14 FC/MC/PC32 800 23.0 16.6 14.00 12.00
17, 21 FC/MC/PC35 800 23.0 16.6 14.00 12.00
17 HC36 800 23.2 16.6 14.00 12.00
– HD36 800 23.4 16.6 14.00 12.00
14,17,21 FC/MC/PC/UC36 1000 29.0 20.0 14.00 12.00
17 HC36 1000 29.6 20.5 14.00 12.00
– HD36 1000 30.0 20.7 14.00 12.00
14 FC/MC/PC/UC37 1200 35.2 25.7 14.00 12.00
17,21 FC/MC/PC/UC42 1200 35.0 25.6 14.00 12.00
17,21 FC/MC/PC/UC43 1200 35.2 25.7 14.00 12.00
21,24 FC/MC/PC/UC48 1200 35.2 25.7 14.00 12.00
21 HC48 1200 34.6 25.3 14.00 12.00
– HD48 1200 34.8 25.0 14.00 12.00
21,24 FC/MC/PC/UC48 1400 39.5 28.9 13.50 11.00
21,24 FC/MC/PC/UC60 1400 40.5 29.6 14.00 12.00
21 HC42 1400 39.0 28.4 13.00 11.00
24 HC60 1400 40.0 29.6 14.00 12.00
– HD48 1400 39.0 28.4 13.25 11.00
– HD60 1400 40.0 28.4 14.00 12.00
21,24 FC/MC/PC/UC48 1600 45.0 33.2 13.50 11.00
21,24 FC/MC/PC/UC60 1600 46.5 33.9 13.90 11.00
21 HC48 1600 45.0 32.6 13.30 11.00
24 HC60 1600 46.0 33.9 13.75 11.00
– HD48 1600 45.0 32.4 13.50 11.00
– HD60 1600 46.0 33.9 13.75 11.00
24 MC61 1600 47.0 34.3 14.00 12.00
21,24 FC/MC/PC/UC60 1800 55.0 38.5 14.00 12.00
24 HC60 1800 55.0 38.5 14.00 12.00
– HD60 1800 55.0 38.7 14.00 12.00
24 MC61 1800 55.5 38.9 14.00 12.00
24 FC/MC62 1800 55.5 38.9 14.00 12.00
COIL
MODEL
RATED
CFM
NET MBH
TOTAL SENS.
COOLING
SEER
1
EER
6 Unitary Products Group
Page 7
COOLING CAPACITY - With Variable Speed Furnaces
UNIT MODEL
HABE-F018S
HDBE-F024S
HCBE-F030S
HABE-F036S
For Notes See Page 9.
FURNACE MODEL
VARIABLE SPEED
1 PH 14 SEER AC WITH VARIABLE SPEED FURNACES
(F,L)L8V*A12 FC/MC/PC24A 14 600 17.9 12.3 15.00 12.00
FL9V*A12 FC/MC/PC24A 14 600 17.8 12.2 15.00 12.00
FL9(C,V)*B12 FC/MC/PC24B 17 600 17.9 12.3 15.00 12.00
(F,L)L8V*A12 FC/MC/PC30A 14 600 17.9 12.3 15.00 12.00
FL9V*A12 FC/MC/PC30A 14 600 17.8 12.2 15.00 12.00
FL9(C,V)*B12 FC/MC/PC30B 17 600 17.9 12.3 15.00 12.00
(F,L)L8V*A12 HC30 14 600 17.7 12.2 15.00 12.00
(F,L)L8V*A12 FC/MC/PC32A 14 800 23.4 17.3 15.00 12.50
FL9V*A12 FC/MC/PC32A 14 800 23.4 17.3 15.00 12.50
FL9(C,V)*B12 FC/MC/PC35B 17 800 23.2 17.2 14.00 12.00
FL9V*A12 HC36 17 800 23.6 17.4 14.00 12.00
(F,L)L8V*A12 HD36 – 800 24.0 17.7 14.00 12.00
FL9V*A12 HD36 – 800 24.0 17.7 14.00 12.00
(F,L)L8V*A12 FC/MC/PC36A 14 1000 29.2 20.1 14.75 12.00
FL9V*A12 FC/MC/PC36A 14 1000 29.2 20.1 14.75 12.00
(F,L)L8V*B16 FC/MC/PC36B 17 1000 29.4 20.2 15.00 12.00
FL9(C,V)*B12 FC/MC/PC36B 17 1000 29.2 20.1 15.00 12.00
(F,L)L8V*C16 FC/MC/PC36C 21 1000 29.4 20.2 15.00 12.00
(F,L)L8V*C20 FC/MC/PC36C 21 1000 29.4 20.2 15.00 12.00
FL9(C,V)*C16 FC/MC/PC36C 21 1000 29.4 20.2 15.00 12.00
(F,L)L8V*B16 HC36 17 1000 30.0 20.7 15.00 12.00
FL9(C,V)*B12 HC36 17 1000 30.0 20.6 15.00 12.00
(F,L)L8V*A12 HD36 – 1000 30.0 20.8 15.00 12.00
(F,L)L8V*B16 HD36 – 1000 30.0 20.9 15.00 12.00
(F,L)L8V*C16 HD36 – 1000 30.0 20.9 15.00 12.00
(F,L)L8V*C20 HD36 – 1000 30.0 20.9 15.00 12.00
FL9V*A12 HD36 – 1000 30.0 20.8 15.00 12.00
FL9(C,V)*B12 HD36 – 1000 30.0 20.8 15.00 12.00
FL9(C,V)*C16 HD36 – 1000 30.0 20.9 15.00 12.00
(F,L)L8V*A12 FC/MC/PC37A 14 1200 35.2 24.9 14.5 12.00
FL9V*A12 FC/MC/PC37A 14 1200 35.2 24.9 14.5 12.00
(F,L)L8V*B16 FC/MC/PC42B 17 1200 35.2 24.9 14.50 12.00
FL9(C,V)*B12 FC/MC/PC42B 17 1200 35.2 24.9 14.50 12.00
(F,L)L8V*C16 FC/MC/PC42C 21 1200 35.2 24.9 14.50 12.00
(F,L)L8V*C20 FC/MC/PC42C 21 1200 35.2 24.9 14.50 12.00
FL9(C,V)*C16 FC/MC/PC42C 21 1200 35.2 24.9 14.50 12.00
FL9(C,V)*C20 FC/MC/PC42C 21 1200 35.2 24.9 14.50 12.00
(F,L)L8V*B16 FC/MC/PC43B 17 1200 35.2 24.9 14.50 12.00
FL9(C,V)*B12 FC/MC/PC43B 17 1200 35.2 24.9 14.50 12.00
(F,L)L8V*C16 FC/MC/PC43C 21 1200 35.2 24.9 14.50 12.00
(F,L)L8V*C20 FC/MC/PC43C 21 1200 35.2 24.9 14.50 12.00
FL9(C,V)*C16 FC/MC/PC43C 21 1200 35.2 24.9 14.50 12.00
FL9(C,V)*C20 FC/MC/PC43C 21 1200 35.2 24.9 14.50 12.00
(F,L)L8V*C16 FC/MC/PC48C 21 1200 36.0 25.5 15.00 12.00
(F,L)L8V*C20 FC/MC/PC48C 21 1200 36.0 25.5 15.00 12.00
FL9(C,V)*C16 FC/MC/PC48C 21 1200 35.6 25.2 15.00 12.00
FL9(C,V)*C20 FC/MC/PC48C 21 1200 35.6 25.2 15.00 12.00
FL9(C,V)*D20 FC/MC/PC48D 24 1200 35.6 25.2 15.00 12.00
(F,L)L8V*C16 HC48 21 1200 35.2 24.9 14.50 12.00
(F,L)L8V*C20 HC48 21 1200 35.2 24.9 14.50 12.00
FL9(C,V)*C16 HC48 21 1200 35.2 24.9 14.50 12.00
FL9(C,V)*C20 HC48 21 1200 35.2 24.9 14.50 12.00
(F,L)L8V*C16 HD48 – 1200 35.2 24.9 14.50 12.00
(F,L)L8V*C20 HD48 – 1200 35.2 24.9 14.50 12.00
FL9(C,V)*C16 HD48 – 1200 35.2 24.9 14.50 12.00
FL9(C,V)*C20 HD48 – 1200 35.2 24.9 14.50 12.00
COIL
MODEL
1
W
RATED
CFM
COOLING
NET MBH
TOTAL SENS.
2
332018-BTG-D-0208
SEER EER
Unitary Products Group 7
Page 8
332018-BTG-D-0208
COOLING CAP ACITY - With Variable Speed Furnaces (Continued)
UNIT MODEL
HBBE-F042S
HBBE-F048S
HCBE-F060S
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.
VARIABLE SPEED
FURNACE MODEL
1 PH 14 SEER AC WITH VARIABLE SPEED FURNACES
(F,L)L8V*C16 FC/MC/PC48C 21 1420 40.0 28.8 14.00 12.00
(F,L)L8V*C20 FC/MC/PC48C 21 1420 40.0 28.8 14.50 12.00
FL9(C,V)*C16 FC/MC/PC48C 21 1400 39.5 28.4 14.00 12.00
FL9(C,V)*C20 FC/MC/PC48C 21 1400 39.5 28.4 14.00 12.00
FL9(C,V)*D20 FC/MC/PC48D 24 1400 39.5 28.4 14.00 12.00
FL9(C,V)*D20 FC/MC/PC60D 24 1400 40.5 29.1 14.50 12.00
(F,L)L8V*C16 FC/PC60C 21 1420 40.0 28.8 14.00 12.00
(F,L)L8V*C20 FC/PC60C 21 1400 41.0 29.5 14.50 12.00
FL9(C,V)*C16 FC/PC60C 21 1400 40.5 29.1 14.50 12.00
FL9(C,V)*C20 FC/PC60C 21 1400 40.5 29.1 14.50 12.00
(F,L)L8V*C20 HC60 24 1400 41.0 29.5 14.50 12.00
FL9(C,V)*D20 HC60 24 1400 40.5 29.1 14.50 12.00
(F,L)L8V*C20 HD60 – 1400 41.0 29.5 14.50 12.00
FL9(C,V)*C20 HD60 – 1400 40.5 29.1 14.50 12.00
FL9(C,V)*D20 HD60 – 1400 40.5 29.1 14.50 12.00
FL9(C,V)*D20 FC/MC/PC60D 24 1600 46.5 33.9 14.25 12.00
(F,L)L8V*C20 FC/PC60C 21 1605 46.5 33.9 14.00 12.00
FL9(C,V)*C20 FC/PC60C 21 1600 46.5 33.9 14.00 12.00
(F,L)L8V*C20 MC60D 24 1605 46.5 33.9 14.00 12.00
FL9(C,V)*C20 MC60D 24 1600 46.5 33.9 14.00 12.00
(F,L)L8V*C20 MC61D 24 1600 47.0 34.3 14.25 12.00
FL9(C,V)*C20 MC61D 24 1600 47.0 34.3 14.25 12.00
FL9(C,V)*D20 MC61D 24 1600 47.0 34.3 14.25 12.00
(F,L)L8V*C20 FC/MC62D 24 1600 47.0 34.3 14.25 12.00
FL9(C,V)*C20 FC/MC62D 24 1600 47.0 34.3 14.25 12.00
FL9(C,V)*D20 FC/MC62D 24 1600 47.0 34.3 14.25 12.00
FL9(C,V)*D20 FC/MC/PC60D 24 1620 54.5 36.8 14.25 12.00
(F,L)L8V*C20 FC/PC60C 21 1730 54.0 37.8 14.00 12.00
FL9(C,V)*C20 FC/PC60C 21 1620 54.5 36.7 14.00 12.00
(F,L)L8V*C20 HC60 24 1730 54.0 37.8 14.00 12.00
FL9(C,V)*D20 HC60 24 1620 54.5 36.8 14.25 11.50
(F,L)L8V*C20 HD60 – 1730 55.0 38.0 14.00 12.00
FL9(C,V)*C20 HD60 – 1620 54.5 36.8 14.00 11.50
FL9(C,V)*D20 HD60 – 1620 55.0 37.0 14.25 11.50
(F,L)L8V*C20 MC61D 24 1730 55.5 38.1 14.00 12.00
FL9(C,V)*C20 MC61D 24 1620 55.0 37.1 14.00 11.50
FL9(C,V)*D20 MC61D 24 1620 55.0 37.1 14.25 11.50
(F,L)L8V*C20 FC/MC62D 24 1730 55.5 38.1 14.00 12.00
FL9(C,V)*C20 FC/MC62D 24 1620 55.0 37.1 14.00 11.50
FL9(C,V)*D20 FC/MC62D 24 1620 55.0 37.1 14.25 11.50
COIL
MODEL
1
W
RATED
CFM
NET MBH
TOTAL SENS.
2
COOLING
SEER EER
8 Unitary Products Group
Page 9
332018-BTG-D-0208
ACCESSORIES
Refer to Price Manual for specific model numbers.
Compressor Blanket - Designed to further reduce the nor-
mal operating sound and is required to meet Canadian sound
levels for units of three tons and below.
Refer to Price Manual for specific model numbers.
Blower Time Delay - Available to increase efficiency when
installed. Installs on indoor section and maintains blower for
approximately one minute after cooling thermostat has been
satisfied.
TXV KIT - 1 TVM series TXV’ s must be used to obtain system
performance. See Tabular Data Sheet for proper selection.
TYPICAL INSTALLATION
MINIMUM 18” SERVICE ACCESS
60” OVERHEAD
CLEARANCE
CLEARANCE ON ONE SIDE
WEATHERPROOF
DISCONNECT
SWITCH
ROOM THERMOSTATS - A wide selection of compatible
thermosets are available to provide optimum performance
and features for any installation.
1H/1C, manual changeover electronic non-programmable
thermostat.
1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.
1H/1C, auto/manual changeover, electronic programmable.
* For the most current accessory information, refer to the
price book or consult factory.
SOUND POWER RATINGS*
UNIT MODEL (dBA)
024 75
030 76
036 76
042 76
048 76
060 76
* Rated in accordance with ARI 270-95 Standards.
THERMOSTAT
TO FURNACE OR
AIR HANDLER
TERMINAL BLOCK
NEC CLASS 1 WIRING
NEC CLASS 2 WIRING
10” CLEARANCE
COIL AREA
NOTE: ALL OUTDOOR WIRING
MUST BE WEATHERPROOF.
TYPICAL FIELD WIRING
ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES
POWER WIRING
208/230-1-60
CONTACTOR
TERMINALS
GND.
LUG
CONDENSING UNIT
COIL
CONTROL ACCESS PANEL
24 VOLT CONTROL WIRING
MINIMUM 18 GA. WIRE
(NEC CLASS 2)
FURNACE OR AIR HANDLER TERMINAL BLOCK
TO INDOOR COIL
SEAL OPENING(S) WITH
PERMAGUM OR EQUIVALENT
POWER WIRING
CONTROL WIRING
FACTORY WIRING
CYRGW
R
Y
ROOM THERMOSTAT
GW
*
*
TERMINAL W IS ONLY
REQUIRED ON SYSTEMS
WITH HEAT.
ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.
Unitary Products Group 9
Page 10
332018-BTG-D-0208
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. HABE-F018S
INDOOR COIL MODEL NO. FC/MC/PC/UC24
CONDENSER
ENTERING AIR
TEMPERATURE
65
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler Coil
AHP24 – 1.01 1.05 1.01
AV24 – 1.02 1.00 0.97
MA08B FC/MC24B 1.00 1.00 1.00
MA08B FC/MC30B 1.00 1.00 1.00
MV12B FC/MC24B 1.02 1.00 0.97
MV12B FC/MC30B 1.02 1.00 0.97
– FC/MC/PC/UC30 1.00 1.00 1.00
– HC30 0.99 1.00 1.00
ID CFM 450 600 750
ID DB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
T.C. 14.9 18.9 17.9 20.4 22.6 16.9 20.5 19.3 22.0 22.9 19.0 22.1 20.8 23.6 23.2
S.C. 14.6 14.2 11.9 12.2 10.3 16.6 16.7 14.1 14.5 11.4 18.6 19.3 16.2 16.8 12.5
K.W 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
T.C. 14.5 17.8 17.0 19.2 21.0 16.3 19.4 18.3 20.7 21.4 18.1 20.9 19.5 22.1 21.8
S.C. 14.213.711.611.7 9.7 16.016.113.513.910.917.718.515.516.012.0
K.W 1.0 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1
T.C. 14.0 16.8 16.1 18.0 19.4 15.6 18.2 17.2 19.3 19.9 17.2 19.7 18.3 20.7 20.3
S.C. 13.7 13.3 11.2 11.2 9.2 15.3 15.5 13.0 13.2 10.3 16.9 17.6 14.8 15.2 11.5
K.W 1.1 1.1 1.1 1.2 1.2 1.1 1.1 1.1 1.2 1.2 1.2 1.2 1.2 1.2 1.2
T.C. 13.6 15.7 15.2 16.9 17.8 15.0 17.1 16.1 18.0 18.3 16.4 18.5 17.0 19.2 18.9
S.C. 13.3 12.8 10.8 10.8 8.6 14.7 14.8 12.4 12.6 9.8 16.0 16.8 14.0 14.4 11.0
K.W 1.2 1.2 1.2 1.2 1.3 1.2 1.2 1.2 1.3 1.3 1.2 1.2 1.2 1.3 1.3
T.C. 12.7 14.7 14.1 15.7 16.5 14.1 16.2 15.0 16.8 16.9 15.4 17.7 15.9 17.8 17.3
S.C. 12.4 12.4 10.3 10.4 8.3 13.8 14.2 11.9 11.9 9.4 15.1 16.0 13.5 13.5 10.5
K.W 1.3 1.3 1.3 1.3 1.4 1.3 1.3 1.3 1.3 1.4 1.3 1.3 1.3 1.4 1.4
T.C. 11.8 13.8 13.0 14.6 15.3 13.2 15.3 13.9 15.6 15.5 14.5 16.9 14.8 16.5 15.7
S.C. 11.5 11.9 9.9 10.0 7.9 12.9 13.6 11.4 11.3 9.0 14.3 15.2 13.0 12.5 10.0
K.W 1.4 1.4 1.4 1.4 1.5 1.4 1.4 1.4 1.4 1.5 1.4 1.4 1.4 1.5 1.5
T.C. 10.9 12.8 12.0 13.5 14.1 12.3 14.4 12.8 14.3 14.1 13.6 16.1 13.7 15.1 14.1
S.C. 10.7 11.5 9.4 9.6 7.6 12.0 13.0 10.9 10.6 8.5 13.4 14.5 12.4 11.6 9.5
K.W 1.4 1.4 1.4 1.5 1.6 1.5 1.5 1.5 1.5 1.6 1.5 1.5 1.5 1.6 1.6
T.C. S.C. KW
Variable Speed
Furnace
(F,L)L8V*A12 FC/MC/PC24A 1.02 1.02 0.98
(F,L)L8V*A12 FC/MC/PC30A 1.02 1.02 0.98
(F,L)L8V*A12 HC30 1.01 1.01 0.97
FL9V*A12 FC/MC/PC24A 1.02 1.01 0.97
FL9V*A12 FC/MC/PC30A 1.02 1.01 0.97
FL9(C,V)*B12 FC/MC/PC24B 1.02 1.02 0.98
FL9(C,V)*B12 FC/MC/PC30B 1.02 1.02 0.98
Coil
T.C. S.C. KW
10 Unitary Products Group
Page 11
332018-BTG-D-0208
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. HDBE-F024S
INDOOR COIL MODEL NO. FC/MC/PC35
CONDENSER
ENTERING AIR
TEMPERATURE
65
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler Coil
AHP30 – 1.00 1.00 1.00
AV36 – 1.00 1.00 1.00
MA12B FC/MC35B 1.01 1.00 0.97
MV12B FC/MC35B 1.01 1.00 0.97
– FC/MC/PC/UC32B 1.00 1.00 1.00
– HC36 1.00 1.00 1.00
– HD36 1.00 1.00 1.00
ID CFM 600 800 1000
ID DB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
T.C. 20.1 22.8 25.9 27.9 23.1 24.6 26.9 29.0 26.1 26.4 27.9 30.2 25.6 27.9 30.2
S.C. 19.9 17.8 16.4 12.9 22.8 21.5 18.9 14.6 25.7 25.2 21.5 16.4 21.0 21.5 16.4
K.W 1.2 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3
T.C. 19.3 21.6 24.8 26.8 22.0 23.3 25.8 27.8 24.8 25.1 26.8 28.8 24.3 26.8 28.8
S.C. 19.1 17.4 15.8 12.5 21.8 20.8 18.1 14.1 24.5 24.2 20.4 15.6 20.6 20.4 15.6
K.W 1.3 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4
T.C. 18.5 20.3 23.7 25.7 21.0 22.1 24.7 26.5 23.5 23.8 25.8 27.4 23.0 25.8 27.4
S.C. 18.3 16.9 15.3 12.1 20.7 20.0 17.3 13.5 23.2 23.2 19.4 14.9 20.1 19.4 14.9
K.W 1.4 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.5 1.5 1.5 1.6 1.5 1.5 1.6
T.C. 17.6 19.1 22.6 24.6 19.9 20.8 23.7 25.3 22.2 22.6 24.7 25.9 21.7 24.7 25.9
S.C. 17.4 16.4 14.7 11.6 19.7 19.3 16.5 12.9 22.0 22.2 18.3 14.1 19.7 18.3 14.1
K.W 1.6 1.6 1.6 1.7 1.6 1.6 1.7 1.7 1.6 1.6 1.7 1.7 1.6 1.7 1.7
T.C. 16.8 18.2 20.8 22.8 18.8 19.6 21.6 23.4 20.7 21.1 22.5 24.0 20.1 22.5 24.0
S.C. 16.7 16.2 14.0 11.0 18.6 18.5 16.0 12.3 20.6 20.9 18.0 13.5 18.7 18.0 13.5
K.W 1.7 1.7 1.8 1.8 1.7 1.7 1.8 1.8 1.8 1.8 1.8 1.8 1.7 1.8 1.8
T.C. 16.0 17.4 19.0 21.1 17.7 18.4 19.7 21.6 19.3 19.4 20.4 22.1 18.6 20.4 22.1
S.C. 15.9 16.0 13.4 10.4 17.6 17.6 15.5 11.7 19.3 19.4 17.7 12.9 17.7 17.7 12.9
K.W 1.8 1.8 1.9 1.9 1.8 1.8 1.9 1.9 1.9 1.9 1.9 2.0 1.9 1.9 2.0
T.C. 15.2 16.5 17.3 19.4 16.6 17.2 17.7 19.8 17.9 18.3 19.2 20.1 17.1 18.2 20.1
S.C. 15.2 14.7 12.7 9.9 16.6 16.6 15.0 11.1 17.0 18.0 17.3 12.3 16.8 17.3 12.3
K.W 1.9 1.9 2.0 2.0 2.0 2.0 2.0 2.1 2.0 2.0 2.0 2.1 2.0 2.0 2.1
T.C. S.C. KW
Variable Speed
Furnace
(F,L)L8V*A12 FC/MC/PC32A 1.01 1.00 0.97
FL9V*A12 FC/MC/PC32A 1.01 1.00 0.97
FL9(C,V)*B12 FC/MC/PC35B 1.01 1.00 0.97
FL9(C,V)*B12 HC36 1.01 1.00 0.97
FL8V*B12 HD36 1.01 1.00 0.97
FL9(C,V)*B12 HD36 1.01 1.00 0.97
Coil
T.C. S.C. KW
Unitary Products Group 11
Page 12
332018-BTG-D-0208
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. HCBE-F030S
INDOOR COIL MODEL NO. FC/MC/PC/UC36
CONDENSER
ENTERING AIR
TEMPERATURE
65
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
ID CFM 800 1000 1200
ID DB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
T.C. 27.4 30.6 30.1 33.7 38.0 29.1 31.6 31.1 34.6 38.8 30.8 32.5 32.1 35.5 39.5
S.C. 27.3 24.2 20.2 20.1 16.7 28.8 27.1 22.4 22.4 18.1 30.2 30.0 24.6 24.6 19.4
K.W 1.5 1.5 1.5 1.5 1.6 1.5 1.5 1.5 1.6 1.6 1.5 1.5 1.5 1.6 1.6
T.C. 26.4 28.9 28.7 32.0 36.0 27.9 29.8 29.6 32.8 36.8 29.4 30.7 30.6 33.6 37.6
S.C. 25.9 23.3 19.6 19.5 16.0 27.4 26.0 21.8 21.7 17.4 28.9 28.7 24.0 23.8 18.8
K.W 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7
T.C. 25.5 27.2 27.3 30.3 34.0 26.7 28.0 28.2 31.0 34.8 28.0 28.8 29.0 31.7 35.7
S.C. 24.4 22.4 19.0 19.0 15.3 26.0 24.9 21.2 21.0 16.7 27.6 27.4 23.5 23.0 18.1
K.W 1.8 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9
T.C. 24.5 25.5 25.9 28.6 32.0 25.5 26.2 26.7 29.2 32.9 26.6 27.0 27.5 29.8 33.8
S.C. 23.0 21.5 18.4 18.4 14.6 24.7 23.8 20.7 20.3 16.0 26.4 26.1 22.9 22.2 17.5
K.W 2.0 2.0 2.0 2.1 2.1 2.0 2.0 2.0 2.1 2.1 2.0 2.0 2.0 2.1 2.1
T.C. 23.0 24.4 24.1 26.7 30.0 24.1 24.9 24.8 27.2 30.6 25.1 25.4 25.5 27.7 31.3
S.C. 21.9 20.5 17.7 17.7 14.0 23.4 22.7 19.8 19.6 15.3 24.8 24.8 21.9 21.5 16.6
K.W 2.2 2.2 2.2 2.2 2.3 2.2 2.2 2.2 2.2 2.3 2.2 2.2 2.2 2.3 2.3
T.C. 21.6 23.4 22.4 24.9 28.0 22.6 23.6 23.0 25.3 28.4 23.6 23.9 23.6 25.7 28.9
S.C. 20.8 19.5 17.0 17.0 13.5 22.1 21.5 19.0 19.0 14.6 23.4 23.6 21.0 20.9 15.8
K.W 2.3 2.3 2.3 2.4 2.5 2.3 2.4 2.3 2.4 2.5 2.4 2.4 2.4 2.4 2.5
T.C. 20.2 22.3 20.7 23.1 26.0 21.2 22.4 21.2 23.4 26.3 22.2 22.4 21.7 23.7 26.5
S.C. 19.7 18.5 16.3 16.4 12.9 20.8 20.4 18.2 18.3 14.0 21.9 22.4 20.1 20.3 15.0
K.W 2.5 2.5 2.5 2.5 2.6 2.5 2.5 2.5 2.6 2.7 2.6 2.6 2.5 2.6 2.7
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler Coil
AHP30 – 1.02 1.20 1.02
AV36 – 1.01 1.00 0.97
F*FP040 – 1.02 1.20 1.02
MA12B FC/MC36B 1.00 1.00 1.00
MV12B FC/MC36B 1.01 1.00 0.97
MV16C FC/MC36C 1.01 1.00 0.97
– HC36 1.02 1.03 1.02
– HD36 1.03 1.04 1.03
T.C. S.C. KW
Variable Speed
Furnace
(F,L)L8V*A12 FC/MC/PC36A 1.01 1.01 1.01
(F,L)L8V*A12 HD36 1.03 1.04 0.99
(F,L)L8V*B16 FC/MC/PC36B 1.01 1.01 0.97
(F,L)L8V*B16 HC36 1.03 1.04 0.99
(F,L)L8V*B16 HD36 1.03 1.05 0.99
(F,L)L8V*C16 FC/MC/PC36C 1.01 1.01 0.97
(F,L)L8V*C16 HD36 1.03 1.05 0.99
(F,L)L8V*C20 FC/MC/PC36C 1.01 1.01 0.97
(F,L)L8V*C20 HD36 1.03 1.05 0.99
FL9V*A12 FC/MC/PC36A 1.01 1.01 1.01
F L 9 V * A 1 2 H D 3 6 1 . 0 31 . 0 40 . 9 9
FL9(C,V)*B12 FC/MC/PC36B 1.01 1.01 0.96
FL9(C,V)*B12 HC36 1.03 1.03 0.99
FL9(C,V)*B12 HD36 1.03 1.04 0.99
FL9(C,V)*C16 FC/MC/PC36C 1.01 1.01 0.97
FL9(C,V)*C16 HD36 1.03 1.05 0.99
Coil
T.C. S.C. KW
12 Unitary Products Group
Page 13
332018-BTG-D-0208
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. HABE-F036S
INDOOR COIL MODEL NO. AHP42
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler Coil
AV36 – 1.00 1.01 0.97
MA14D FC/MC42D 0.99 1.01 1.06
MA14D FC/MC48D 1.00 1.02 1.07
MV16C FC/MC42C 1.00 1.01 0.97
MV16C FC/MC48C 1.02 1.02 0.97
– FC/MC/PC/UC37 1.00 1.00 1.00
– FC/MC/PC/UC42 0.99 1.01 1.06
– FC/MC/PC/UC43 1.00 1.00 1.00
– FC/MC/PC/UC48 1.00 1.02 1.07
– HC48 0.98 1.00 1.05
– HD48 0.99 0.99 1.06
ID CFM 1000 1200 1400
ID DB 85 80 70 85 80 70 85 80 70
ID WB 72 67 57 72 67 57 72 67 57
T.C. 40.0 36.9 34.3 41.3 38.1 35.7 42.0 38.9 36.7
S.C. 25.4 24.4 23.4 27.6 26.3 25.5 29.6 27.9 27.2
K.W 1.98 1.96 1.94 1.99 1.97 1.95 2.00 1.98 1.96
T.C. 38.6 35.6 32.7 39.6 36.6 34.0 40.2 37.3 34.9
S.C. 24.8 23.8 22.8 27.0 25.8 24.9 29.1 27.6 26.6
K.W 2.21 2.18 2.17 2.22 2.19 2.18 2.23 2.20 2.19
T.C. 37.2 34.2 31.0 37.8 35.2 32.4 38.4 35.8 33.0
S.C. 24.2 23.3 22.3 26.4 25.3 24.2 28.5 27.2 25.9
K.W 2.44 2.41 2.40 2.45 2.42 2.41 2.46 2.42 2.42
T.C. 35.5 32.3 29.6 36.1 33.1 30.6 36.7 33.7 31.2
S.C. 23.5 22.6 21.7 25.6 24.6 23.5 27.6 26.5 25.3
K.W 2.75 2.72 2.72 2.75 2.73 2.72 2.76 2.73 2.73
T.C. 33.7 30.4 28.1 34.4 31.1 28.7 35.0 31.7 29.4
S.C. 22.8 21.8 21.1 24.7 23.9 22.8 26.8 25.8 24.6
K.W 3.06 3.04 3.03 3.06 3.04 3.02 3.07 3.04 3.03
T.C. 31.9 28.5 26.7 32.7 29.1 26.9 33.3 29.7 27.6
S.C. 22.2 21.1 20.5 23.9 23.1 22.1 25.9 25.1 24.0
K.W 3.37 3.36 3.34 3.37 3.35 3.32 3.38 3.35 3.33
T.C. S.C. KW
Variable Speed
Furnace
(F,L)L8V*A12 FC/MC/PC37A 1.00 0.98 0.97
FL9V*A12 FC/MC/PC37A 1.00 0.98 0.97
(F,L)L8V*B16 FC/MC/PC42B 1.00 0.98 0.97
(F,L)L8V*C16 FC/MC/PC42C 1.00 0.98 0.97
(F,L)L8V*B16 FC/MC/PC43B 1.00 0.98 0.97
(F,L)L8V*C16 FC/MC/PC43C 1.00 0.98 0.97
(F,L)L8V*C16 FC/MC/PC48C 1.02 1.01 0.97
(F,L)L8V*C16 HC48 1.00 0.98 0.97
(F,L)L8V*C16 HD48 1.00 0.98 0.97
(F,L)L8V*C20 FC/MC/PC42C 1.00 0.98 0.97
(F,L)L8V*C20 FC/MC/PC43C 1.00 0.98 0.97
(F,L)L8V*C20 FC/MC/PC48C 1.02 1.01 0.97
(F,L)L8V*C20 HC48 1.00 0.98 0.97
(F,L)L8V*C20 HD48 1.00 0.98 0.97
FL9(C,V)*B12 FC/MC/PC42B 1.00 0.98 0.97
FL9(C,V)*C16 FC/MC/PC42C 1.00 0.98 0.97
FL9(C,V)*B12 FC/MC/PC43B 1.00 0.98 0.97
FL9(C,V)*C16 FC/MC/PC43C 1.00 0.98 0.97
FL9(C,V)*C16 FC/MC/PC48C 1.01 1.00 0.97
FL9(C,V)*C16 HC48 1.00 0.98 0.97
FL9(C,V)*C16 HD48 1.00 0.98 0.97
FL9(C,V)*C20 FC/MC/PC42C 1.00 0.98 0.97
FL9(C,V)*C20 FC/MC/PC43C 1.00 0.98 0.97
FL9(C,V)*C20 FC/MC/PC48C 1.01 1.00 0.97
FL9(C,V)*C20 HC48 1.00 0.98 0.97
FL9(C,V)*C20 HD48 1.00 0.98 0.97
FL9(C,V)*D20 FC/MC/PC48D 1.01 1.00 0.97
Coil
T.C. S.C. KW
Unitary Products Group 13
Page 14
332018-BTG-D-0208
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. HBBE-F042S
INDOOR COIL MODEL NO. FC/MC/PC/UC60
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler Coil
AHP/SHP48 – 1.00 1.01 1.00
AV/SV48 – 1.00 1.01 0.96
AV/SV60 – 1.00 1.01 0.96
AHP/SHP60 – 1.00 1.01 0.96
MA14D FC/MC48D 0.98 0.98 1.02
MA14D FC/MC60D 1.00 1.00 1.00
MA16C FC60C 1.00 1.00 1.00
MV16C FC/MC48C 1.00 0.98 1.00
MV20D FC/MC60D 1.02 1.00 1.02
– FC/MC/PC/UC48 0.98 0.98 1.02
– HC48 0.96 0.96 1.01
– HC60 0.99 1.00 0.99
– HD48 0.96 0.96 1.01
– HD60 0.99 0.96 0.99
ID CFM 1300 1450 1550
ID DB 85 80 75 70 85 80 75 70 85 80 75 70
ID WB 72 67 62 57 72 67 62 57 72 67 62 57
T.C. 47.3 43.8 40.3 37.2 47.7 44.3 40.9 37.7 48.0 44.5 41.2 38.0
S.C. 28.3 28.5 28.9 29.2 29.8 30.0 30.6 30.7 30.8 31.0 31.6 31.7
K . W 2 . 8 82 . 8 42 . 8 02 . 7 72 . 9 52 . 9 02 . 8 72 . 8 43 . 0 02 . 9 52 . 9 12 . 8 8
T.C. 44.6 41.3 38.1 35.1 45.0 41.8 38.6 35.5 45.2 42.1 38.8 35.9
S.C. 27.4 27.6 28.1 28.2 29.0 29.2 29.6 29.8 30.0 30.2 30.6 30.8
K.W 3.14 3.10 3.06 3.04 3.20 3.16 3.13 3.11 3.25 3.21 3.17 3.15
T.C. 42.2 39.0 36.0 33.1 42.5 39.5 36.4 33.7 42.8 39.7 36.6 33.9
S.C. 26.6 26.8 27.2 27.4 28.2 28.4 28.7 28.9 29.3 29.4 29.7 29.8
K . W 3 . 4 53 . 4 13 . 3 93 . 3 73 . 5 23 . 4 83 . 4 53 . 4 33 . 5 63 . 5 23 . 4 93 . 4 7
T.C. 39.7 36.8 33.9 31.2 40.1 37.2 34.2 31.8 40.3 37.3 34.4 32.2
S.C. 25.9 26.1 26.4 26.6 27.5 27.6 27.9 28.2 28.5 28.5 28.9 28.6
K . W 3 . 8 23 . 7 93 . 7 73 . 7 53 . 8 93 . 8 63 . 8 33 . 8 13 . 9 33 . 9 03 . 8 73 . 8 5
T.C. 37.2 34.5 31.7 29.3 37.6 34.8 32.1 30.0 37.8 35.0 32.3 30.3
S.C. 25.1 25.2 25.5 25.6 26.7 26.7 27.1 26.6 27.7 27.7 27.9 26.9
K . W 4 . 2 64 . 2 34 . 2 14 . 1 94 . 3 24 . 2 94 . 2 74 . 2 64 . 3 64 . 3 44 . 3 14 . 3 0
T.C. 34.7 32.2 29.5 27.4 35.1 32.4 30.0 28.2 35.3 32.7 30.2 28.4
S.C. 24.3 24.3 24.6 24.6 25.9 25.8 26.3 25.0 26.9 26.9 26.9 25.2
K . W 4 . 7 04 . 6 74 . 6 54 . 6 34 . 7 54 . 7 24 . 7 14 . 7 14 . 7 94 . 7 84 . 7 54 . 7 5
T.C. S.C. KW
Variable Speed
Furnace
(F,L)L8V*C16 FC/MC/PC48C 0.99 0.97 0.99
(F,L)L8V*C16 FC/PC60C 0.99 0.97 0.99
(F,L)L8V*C20 FC/MC/PC48C 0.99 0.97 0.99
(F,L)L8V*C20 FC/PC60C 1.01 1.00 1.01
(F,L)L8V*C20 HC60 1.01 1.00 1.01
(F,L)L8V*C20 HD60 1.01 1.00 1.01
FL9(C,V)*C16 FC/MC/PC48C 0.98 0.96 0.98
FL9(C,V)*C16 FC/PC60C 1.00 0.98 1.00
FL9(C,V)*C20 FC/MC/PC48C 0.98 0.96 0.98
FL9(C,V)*C20 FC/PC60C 1.00 0.98 1.00
FL9(C,V)*C20 HD60 1.00 0.98 1.00
FL9(C,V)*D20 FC/MC/PC48D 0.98 0.96 0.98
FL9(C,V)*D20 FC/MC/PC60D 1.00 0.98 1.00
FL9(C,V)*D20 HC60 1.00 0.98 1.00
FL9(C,V)*D20 HD60 1.00 0.98 1.00
Coil
T.C. S.C. KW
14 Unitary Products Group
Page 15
332018-BTG-D-0208
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. HBBE-F048S
INDOOR COIL MODEL NO. FC/MC/PC/UC60
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler Coil
AHP/SHP48 – 1.00 0.99 1.07
AHP/SHP60 – 1.00 0.99 1.03
AV/SV48 – 1.02 1.03 0.91
AV/SV60 – 1.02 1.03 0.91
F*FV060 – 1.02 1.03 0.91
MA16C FC/MC48C 0.97 0.98 1.04
MA16C FC60C 1.00 1.00 1.07
MA20D FC/MC48D 0.97 0.98 1.04
MA20D FC/MC60D 1.00 1.00 1.07
MA20D MC61D 1.01 1.01 1.04
MA20D FC/MC62D 1.01 1.01 1.04
MV20D FC/MC48D 0.99 0.98 1.02
MV20D FC/MC60D 1.01 1.00 1.04
– FC/MC/PC/UC48 0.97 0.98 1.04
– HC48 0.97 0.96 1.04
– HC60 0.99 1.00 1.06
– HD48 0.97 0.96 1.04
ID CFM 1400 1600 1800
ID DB 85 80 70 85 80 70 85 80 70
ID WB 72 67 57 72 67 57 72 67 57
T.C. 53.3 49.5 45.5 54.3 50.2 46.4 55.2 51.0 47.3
S.C. 33.4 32.6 31.1 35.9 35.0 33.0 38.3 37.4 34.9
K.W 2.76 2.72 2.69 2.77 2.74 2.70 2.77 2.76 2.70
T.C. 51.2 47.7 43.9 52.0 48.4 44.8 52.8 49.1 45.7
S.C. 33.1 32.1 30.6 35.4 34.5 32.6 37.7 36.8 34.6
K.W 3.07 3.04 3.01 3.07 3.05 3.02 3.08 3.06 3.03
T.C. 49.0 45.9 42.4 49.7 46.5 43.2 50.3 47.2 44.1
S.C. 32.7 31.6 30.0 34.9 33.9 32.2 37.1 36.2 34.4
K.W 3.37 3.35 3.33 3.38 3.36 3.34 3.38 3.37 3.35
T.C. 46.6 43.5 40.1 47.3 44.1 40.8 48.0 44.7 41.6
S.C. 31.7 30.7 29.0 34.0 32.9 31.2 36.3 35.1 33.3
K.W 3.78 3.75 3.74 3.79 3.76 3.75 3.79 3.77 3.75
T.C. 44.1 41.1 37.8 44.9 41.6 38.4 45.6 42.2 39.1
S.C. 30.8 29.8 28.1 33.1 31.9 30.2 35.4 34.1 32.3
K.W 4.18 4.16 4.15 4.19 4.16 4.15 4.21 4.16 4.15
T.C. 41.7 38.7 35.5 42.5 39.2 36.0 43.3 39.7 36.6
S.C. 29.8 28.8 27.1 32.2 31.0 29.2 34.6 33.1 31.3
K.W 4.59 4.56 4.56 4.60 4.56 4.55 4.62 4.56 4.55
T.C. S.C. KW
– HD60 0.99 1.00 1.06
– MC61 1.01 1.01 1.04
Variable Speed
Furnace
(F,L)L8V*C20 FC/PC60C 1.00 1.00 1.03
(F,L)L8V*C20 MC60D 1.00 1.00 1.03
(F,L)L8V*C20 MC61D 1.01 1.01 1.04
(F,L)L8V*C20 FC/MC62D 1.01 1.01 1.04
FL9(C,V)*C20 FC/PC60C 1.00 1.00 1.03
FL9(C,V)*C20 MC60D 1.00 1.00 1.03
FL9(C,V)*C20 MC61D 1.01 1.01 1.04
FL9(C,V)*C20 FC/MC62D 1.01 1.01 1.04
FL9(C,V)*D20 FC/MC/PC60D 1.00 1.00 1.03
FL9(C,V)*D20 MC61D 1.01 1.01 1.04
FL9(C,V)*D20 FC/MC62D 1.01 1.01 1.04
Coil
T.C. S.C. KW
Unitary Products Group 15
Page 16
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. HCBE-F060S
INDOOR COIL MODEL NO. MC61
CONDENSER
ENTERING AIR
TEMPERATURE
65
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler Coil
AHP/SHP60 – 1.00 1.06 1.00
AV/SV60 – 1.00 1.06 1.00
F*FV060 – 1.00 1.06 1.00
MA20D FC/MC60D 1.00 1.04 1.00
MA20D MC61D 1.01 1.05 1.01
MA20D FC/MC62D 1.01 1.05 1.01
MV20D FC/MC60D 1.00 1.01 1.00
MV20D MC61D 1.01 1.02 1.01
MV20D FC/MC62D 1.01 1.02 1.01
– FC/MC/PC/UC60 1.00 1.04 1.00
– HC60 1.00 1.04 1.00
– HD60 1.00 1.04 1.00
ID CFM 1550 1800 2050
ID DB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
T.C. 52.7 58.9 53.1 62.5 62.4 55.9 60.2 55.2 64.0 62.9 59.1 61.5 57.2 65.6 63.5
S.C. 47.9 48.5 38.3 38.0 28.9 50.5 51.7 41.4 42.2 30.4 53.1 54.9 44.5 46.4 31.9
K.W 2.7 2.8 2.8 2.9 2.9 2.8 2.8 2.8 2.9 2.9 2.8 2.8 2.8 2.8 2.9
T.C. 52.0 56.8 51.6 59.9 60.5 54.9 58.2 53.4 61.5 61.3 57.9 59.6 55.3 63.1 62.1
S.C. 46.8 47.3 37.7 37.6 28.4 49.3 50.3 40.7 41.4 30.0 51.7 53.4 43.7 45.2 31.7
K.W 3.2 3.2 3.2 3.3 3.3 3.2 3.2 3.2 3.3 3.3 3.2 3.2 3.2 3.3 3.3
T.C. 51.2 54.7 50.0 57.4 58.7 54.0 56.2 51.7 59.0 59.7 56.7 57.7 53.3 60.7 60.7
S.C. 45.8 46.0 37.1 37.2 27.9 48.0 48.9 40.0 40.6 29.7 50.3 51.8 42.9 44.0 31.5
K.W 3.6 3.6 3.6 3.6 3.7 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.7 3.7
T.C. 50.5 52.6 48.4 54.9 56.9 53.0 54.2 49.9 56.6 58.1 55.5 55.8 51.4 58.2 59.4
S.C. 44.7 44.8 36.4 36.8 27.4 46.8 47.5 39.2 39.8 29.3 48.8 50.3 42.0 42.8 31.2
K.W 4.0 4.0 4.0 4.0 4.1 4.0 4.0 4.0 4.1 4.1 4.0 4.1 4.0 4.1 4.1
T.C. 48.3 49.8 46.0 52.6 54.4 50.8 51.8 47.4 54.1 55.5 53.4 53.7 48.8 55.6 56.7
S.C. 42.9 43.1 35.3 35.9 26.3 44.8 45.5 38.0 38.9 28.2 46.8 48.0 40.6 41.8 30.2
K.W 4.6 4.6 4.6 4.6 4.7 4.6 4.6 4.6 4.6 4.7 4.6 4.6 4.6 4.7 4.7
T.C. 46.1 47.1 43.7 50.4 52.0 48.7 49.4 45.0 51.7 53.0 51.3 51.7 46.3 53.1 54.1
S.C. 41.1 41.5 34.2 35.1 25.3 43.0 43.6 36.7 38.0 27.2 44.8 45.7 39.3 40.8 29.1
K.W 5.1 5.2 5.2 5.2 5.2 5.1 5.2 5.2 5.2 5.3 5.2 5.2 5.2 5.2 5.3
T.C. 44.0 44.4 41.3 48.2 49.6 46.6 47.0 42.5 49.4 50.5 49.2 49.7 43.7 50.5 51.4
S.C. 39.4 39.9 33.1 34.3 24.2 41.1 41.7 35.5 37.0 26.1 42.9 43.5 37.9 39.8 28.1
K.W 5.7 5.7 5.7 5.7 5.8 5.7 5.7 5.7 5.8 5.8 5.7 5.8 5.7 5.8 5.8
T.C. S.C. KW
Variable Speed
Furnace
(F,L)L8V*C20 FC/PC60C 0.98 1.02 0.98
(F,L)L8V*C20 HC60 0.98 1.02 0.98
(F,L)L8V*C20 HD60 1.00 1.02 1.00
(F,L)L8V*C20 MC61D 1.01 1.03 1.01
(F,L)L8V*C20 FC/MC62D 1.01 1.03 1.01
FL9(C,V)*C20 FC/PC60C 0.99 0.99 0.99
FL9(C,V)*C20 HD60 0.99 0.99 0.99
FL9(C,V)*C20 MC61D 1.00 1.00 1.00
FL9(C,V)*C20 FC/MC62D 1.00 1.00 1.00
FL9(C,V)*D20 FC/MC/PC60D 0.99 0.99 0.99
FL9(C,V)*D20 HC60 0.99 0.99 0.99
FL9(C,V)*D20 HD60 1.00 1.00 1.00
FL9(C,V)*D20 MC61D 1.00 1.00 1.00
FL9(C,V)*D20 FC/MC62D 1.00 1.00 1.00
Coil
T.C. S.C. KW
Subject to change without notice. Printed in U.S.A. 332018-BTG-D-0208
Copyright © by Unitary Products Group. 2008. All rights reserved. Supersedes: 332018-BTG-C-0108
Unitary 5005 Norman
Product York OK
Group Drive 73069