York GY9S-UP User Manual

TECHNICAL GUIDE
MODELS: GY9S-UP GAS-FIRED
CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES
92% TO 94% AFUE
NATURAL GAS 40 - 135 MBH INPUT
EFFICIENCY RATING CERTIFIED
ISO 9001
Certified Quality
Management System
277805-YTG-A-1106
DESCRIPTION
These Category IV, highly efficient, compact, condensing type furnaces are designed for residential and commercial installations in a basement, closet, alcove, recreation room or garage where the ambient temperature is above 32°F, or higher. They may be either side wall or thru-roof vented using approved plastic type combustion air and vent piping. All units are factory assembled, wired and tested to assure dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig­inal purchaser; a 20-year limited warranty from original instal­lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli­cations.
5-year limited parts warranty.
FEATURES
Compact, easy to install, ideal height 40" cabinet
Blower-off delay for cooling SEER improvement.
Easy to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement applica­tion.
Integrated control module for reliable, economical opera­tion.
May be installed as either two-pipe (sealed combustion) or single pipe vent (using indoor combustion air)
T op intake & vent connection allows installation in narrow locations.
Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.
Induced combustion system with inshot main burners for quiet, efficient operation.
No special vent termination kit required.
100% shut off main gas valve for extra safety.
PSC four speed, direct drive motor with large, quiet blower.
24V , 40 V A control transformer and blower relay supplied for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Secondary (condensing) heat exchanger of 29-4C high­grade stainless steel.
Timed on, adjustable off blower capability for maximum comfort.
Solid removable bottom panel allows easy application.
Easy access from front of unit for cleaning, maintenance or service.
Protection from intake, exhaust or condensate blockage.
Due to continuous product improvement, specific a tions are subject to change without notice.
Visit us on the web at www.york.com for the most up-to-date technical information.
Additional rating information can be found at www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
277805-YTG-A-1106
28-1/2 26-1/2 24-5/8
1-1/2” GAS PIPE ENTRY
7/8” JUNCTION BOX HOLE
T-STAT WIRING 7/8” K.O.
CONDENSATE DRAIN 7/8” K.O.
OPTIONAL RETURN AIR CUT-OUT (either side) FOR USE WITH EXTERNAL FILTER FRAME
7/8
Models
23-3/4
LEFT SIDE
Nominal
CFM
13-7/8
11
7
BOTTOM IMAGE
RETURN END
30-7/8
21-1/2
7/8
26-3/4
Cabinet
Size
1-1/2
C
A
40
28-3/8
21-1/2
11
8
FRONT
1-1/4
24-3/8
20
D
2
24-7/16
TOP IMAGE
SUPPLY END
5/8
5/8
B
Cabinet Dimension
A (in.) B (in.) C (in.) D (in.)
26-1/2
25-3/8
1-1/2” GAS PIPE ENTRY
7/8” JUNCTION BOX HOLE
T-STAT WIRING 7/8” K.O.
CONDENSATE DRAIN 7/8” K.O.
RIGHT SIDE
GY9S040A12UP11 1200 A 14-1/2 13-1/4 11-1/2 6-1/4 GY9S060B12UP11 1200 B 17-1/2 16-1/4 14-1/2 8-1/2 GY9S080B12UP11 1200 B 17-1/2 16-1/4 14-1/2 8-1/2 GY9S080C16UP11 1600 C 21 19-3/4 18 8-7/8 GY9S080C20UP11 2000 C 21 19-3/4 18 8-7/8 GY9S100C16UP11 1600 C 21 19-3/4 18 8-7/8 GY9S100C20UP11 2000 C 21 19-3/4 18 8-7/8 GY9S120D20UP11 2000 D 24-1/2 23-1/4 21-1/2 10-5/8 GY9S135D20UP11 2000 D 24-1/2 23-1/4 21-1/2 10-5/8
2 Johnson Controls Unitary Products
ELECTRICAL AND PERFORMANCE DATA
277805-YTG-A-1106
Model
Input/
Cabinet
Output
Nominal
Airflow
Cabinet
Width
Total Unit AFUE Air Temp. Rise
MBH MBH CFM In. Amps % °F GY9S040A12UP11 40/A 38 1200 14-1/2 9 94.0 35 - 65 GY9S060B12UP11 60/B 56 1200 17-1/2 9 92.0 40 - 70 GY9S080B12UP11 80/B 74 1200 17-1/2 9 92.0 45 - 75 GY9S080C16UP11 80/C 75 1600 21 12 92.0 45 - 75 GY9S080C20UP11 80/C 75 2000 21 14 92.0 40 - 70 GY9S100C16UP11 100/C 93 1600 21 12 92.0 45 - 75 GY9S100C20UP11 100/C 93 2000 21 14 92.0 40 - 70 GY9S120D20UP11 120/D 112 2000 24-1/2 14 92.0 40 - 70 GY9S135D20UP11 135/D 127 2000 24-1/2 14 92.0 45 - 75
Model
Input/
Cabinet
Max.
Outlet
Air Temp.
Blower
MBH °F HP Amps In. Lbs.
Blower
Size
Max.
Over-current
Protect
Min. Wire Size
(awg) @ 75 ft.
One Way
Operating
Wt
GY9S040A12UP11 40/A 165 1/2 7.0 11 x 8 20 14 119 GY9S060B12UP11 60/B 170 1/2 7.0 11 x 8 20 14 133 GY9S080B12UP11 80/B 175 1/2 7.0 11 x 8 20 14 140 GY9S080C16UP11 80/C 175 3/4 10.2 11 x 10 20 14 155 GY9S080C20UP11 80/C 170 1 12.7 11 x 11 20 12 157 GY9S100C16UP11 100/C 175 3/4 10.2 11 x 10 20 14 160 GY9S100C20UP11 100/C 170 1 12.7 11 x 11 20 12 162 GY9S120D20UP11 120/D 170 1 12.7 11 x 11 20 12 178 GY9S135D20UP11 135/D 175 1 12.7 11 x 11 20 12 178
Nominal external static pressure is 0.50” w.c. at furnace outlet ahead of cooling coils. Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
NOTES:
1. For altitudes above 2000 ft. reduce capacit y 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
Johnson Controls Unitary Products 3