WATER SYSTEMS
Features
• 6 speed fan
• Cabinet factory tted
• Valve factory tted
• Electrical heater factory tted
• Thermal or modulating valve
• Service valve
Thermostats
CSL00 (Built in)
CSR00 (Wall mounted)
Fan speed selector
CML00 (Built in)
CMR00 (Wall mounted)
Thermostat with manual fan speed and S/W
change over
CEL00 (Built in)
CER00 (Wall mounted)
Thermostat with manual fan speed and automatic
change over
CEL20 (Built in)
CER20 (Wall mounted)
Thermostat with auto. fan speed and automatic
change over
CEL30 (Built in)
CER30 (Wall mounted)
Thermostat with auto. fan speed and automatic
change over for modulating valve
Fan Coil Unit
LOW BODY (2 & 4 pipe system)
A complete range from 0.8 kW up to 2.7 kW
Technical features
YLVR - YLIVR
Model 110 112 114 216 218
Cooling capacity (1) 2 rows
Cooling capacity (1) 3 rows
Heating capacity (2) 1 row
Pressure drop (3)
Power supply
Sound power level (3)
Sound pressure level at 3 m
Water connections
Dimensions indicated next page
(1) Cooling capacities based on 7ºC EWT ∆t 5ºC indoor temperature 27ºC DB / 19ºC WB - (2 pipes - high speed fan)
(2) Heating capacities based on 70ºC EWT ∆t 10ºC indoor temperature 20ºC - (2 pipes - high speed fan)
(3) In cooling mode 2 rows
For other conditions contact York international
W 832 1054 1493 2041 2356
W 913 1266 1790 2327 2714
W 1167 1691 2319 3029 3552
kPa 7 1.7 3.8 9 11.7
V/Ph/Hz 230 / 1 / 50 + E
dB(A) 49 50 53 53 55
dB(A) 31 32 35 35 37
inch 1/2 “
Selection
software
Fan Coil Unit LOW BODY
0.8 to 2.7 kW
Compatibility table / Codes
Model 110 112 114 216 218
With Cabinet
YLVR
Without Cabinet
YLIVR
Options (Factory fitted)
Coil and heaters
1 row heating BA1
Kit electrical heater (with relay and safety switch) KREL
Built in thermostat
Fan speed selector CSL00
Thermostat with manual fan speed and S/W change over CML00
Thermostat with manual fan speed, dead band, automatic
change over
Thermostat with automatic fan speed, dead band, automatic
change over
Thermostat with automatic fan speed, dead band, automatic
change over for modulating valve
Parallel connection
For ON/OFF valve one/FCU CBL20
For modulating valve one/FCU CBL30
3 way valve factory fitted
For 2 pipe systems ON/OFF J3A2 (2p)
For 4 pipe systems ON/OFF J3A2 (4p)
3 way modulating valve factory fitted
For 2 pipe systems Modulating J3AM (2p)
For 4 pipe systems Modulating J3AM (4p)
Shut off valves factory fitted
For 2 pipe systems DT (2p)
For 4 pipe systems DT (4p)
2 rows
3 rows
4 rows
2 rows
3 rows
4 rows
CEL00
CEL20
CEL30
l l l l l
l l l l l
l l l l l
l l l l l
l l l l l
l l l l l
l l l l l
l l l l l
l
l
l
l
l
l
l
l
l
l
l
l
l
Condensate pump
WS sensor change over for CEL/CER
Minimum temperature thermostat
Accessories (Supplied loose)
Remote controllers and thermostat (wall mounted)
Fan speed selector CSR00
Thermostat with manual fan speed and S/W change over CMR00
Thermostat with manual fan speed, dead band, automatic
change over
Thermostat with automatic fan speed, dead band, automatic
change over
Thermostat with automatic fan speed, dead band, automatic
change over for modulating valve
(1) for check compatibility with the models of FCU see compatibility table
E-COM-H0702
PC
WS
TM
CER00
CER20
CER30
l
l
l
l
l
l
l
l