30Watts Single Output External Adapter
ADE-300X series
Feature:
•90 to 264Vac universal input range.
•UL/CUL,TUV,CE,CB safety meet.
•EMI/RFI meet VDE & FCC limit B.
•Low cost & compact size.
•30 watts in 120.5×61×35.5 mm size.
•2 Year Warranty.
Specifications: typical at nominal line, full load at 25°C.
|
Input Specifications: |
General Specifications: |
|
Input voltage: 90 to 264Vac |
Efficiency: 70% typical at full load |
||
|
|
||
Input Frequency: 47 Hz to 63Hz |
Hold-up time: 10ms @ 115Vac full load |
||
|
|
||
Input inrush current: 20A a t 115Vac |
EMI/RFI: VDE & FCC Class B limits |
||
|
40A at 230Vac |
|
|
|
Dielectric Withstand: |
||
|
|
||
Earth leakage: 0.2mA max @ 115Vac |
Input/output: 3000Vac |
||
|
0.4mA max @ 230Vac |
Input/Ground: 1500Vac |
|
|
Output Specifications: |
¬Safety Meet: UL/CUL UL60950 |
|
|
|
TUV EN60950 |
|
Output Rating: See selection table |
|||
CE N55022&EN50082-1 |
|||
|
|
||
Output Voltage Accuracy : ± 5% max. |
|||
CB IEC950 |
|||
Line Regulation: ± 1% max. |
Switching frequency: 50kHz(reference) |
||
|
|
||
Load Regulation: ± 5% max. |
Weight: 300g |
||
(Full to half load) |
|
||
Transient Response: ± 1% max.dev. |
MTBF: 100,000hours(MIL-HDBK-217F) |
||
(Full to half load) 500uS recovery |
|
||
Environmental Specifications: |
|||
Temperature Coefficient: ± 0.04% / °C |
Operating temperature: 0 to +40°C |
||
|
|
||
Ripple & Noise: 1% P-P max. |
Storage temperature: -20 to +85°C |
||
|
|
||
Protections: |
Humidity: 5 to 95 % RH non-condensing |
||
|
a. Over voltage protection |
|
|
|
Vibration: 2.4G , 5 to 500Hz |
||
|
b. Over power protection |
||
|
|
||
|
c. Short circuit protection |
Cooling: Free air convection |
|
Note: |
|
1.Vibration test: Three orthogonal axes, random vibration, 10 minutes for each axis.
2.Maximum output power is 30W.
3.At least 20% of load is required to obtain stable regulation.
4.Ripple & noise test method is measured at output terminal across a 0.1uF ceramic cap & a 10uF tantalum or electrolytic cap in parallel with a 20MHz bandwidth oscilloscope
directly.
¬Please refer the safety approval status on appendix 1, For latest safety approval status Please consult YCL or visit" www.ycl.com.tw
Date: Sep 19,2003 |
60 |