Performance Features
• Overload Capacity: 150% for 60 sec. (Heavy Duty) 120% for 60 sec. (Normal Duty)
• Control Methods: V/f Control, Open Loop Current Vector Control, PM Open Loop Current Vector Control Simple closed loop speed control
• DC injection braking, ramp to stop
• Electronic reversing
• Adjustable accel/decel:0.01 to 6000 seconds
• Controlled speed range:
(1)
40:1
• Speed Regulation: ± 0.5 to 1% with slip compensation ± 0.2%
(2)
100:1
(2)
(1)
• Displacement power factor: 0.98
• Output frequency: 0 to 400 Hz
• Frequency resolution:
0.01 Hz with digital reference
0.06 / 60 Hz with analog reference
• Frequency accuracy:
0.01% with digital command
0.5% with analog command
• Volts / hertz ratio: infinitely adjustable pattern
• DC Injection braking: adjustable amplitude, duration, current limited
• Torque boost: full range, auto
• Power loss ride-thru: 0.5 sec.
• Speed search
• Auto restart
• 3 Critical frequency rejection settings
• Slip Compensation
• Energy $avings Function
• Enhanced PID with loss of feedback function
Design Features
• Dual microprocessor logic
• Digital keypad operator, 5 digits
• LED status display
• Remote Mount Keypad Capability
• RJ-45 Style Digital Operator Connector
• 7 multifunction digital inputs
• 3 multifunction digital outputs
• Hardwire baseblock (EN954-1 Cat. 3)
• Programmable form C output contact for customer use: 1A at 250 VAC or 30 VDC
• 24 VDC control logic compatible with sourcing or sinking outputs (PNP or NPN)
• Carrier frequency: 15 kHz max; swing PWM
• 16 multi-speed settings plus jog speed
• 2 Remote speed references: 0-10 VDC (20 kohms) or isolated 4-20 mA (250 ohms)
• Signal follower: bias and gain
• 2 programmable open collector outputs
• Analog monitor output: 0-10 VDC proportional to output frequency or output current
• Approximately 400 parameters
• Digital pulse train input (33 kHz max.)
• Cooling fan controlled by drive run/stop
• RS-422/485 Modbus 115 kbps
• UL recognized electronic overload
• MTBF: 28 years
• Built-in Dynamic Braking Transistor
• NEMA 1 enclosure
• Side-by-Side mounting
• Application presets
• Maintenance monitors
(1)
V/f Mode
(2)
Open Loop Current Vector Mode
Protective Features
• Current limit, stall prevention during accel, decel, and run
• Motor and drive overload
• Over voltage prevention function
• Instantaneous over current
• Short circuit
• Under voltage
• Heatsink overheat
• Ground fault protection
• Over/under torque
• Short circuit withstand rating: 30K RMS
Service Conditions
• Ambient service temperature:
-10° to 40°C (+14° to 104°F) NEMA 1
-10° to 50°C (+14° to 122°F) Open Chassis
• Ambient storage temperature:
-20° to 60°C (-4° to 140°F)
• Humidity: to 95% non-condensing
• Altitude: to 3300 ft; higher by derating
• Service factor: 1.0
• Input voltage: -15% to +10% 200 to 240 VAC, 380 to 480 VAC
• Input frequency: +/-5%; 50/60 Hz
• Input phase sequence insensitive
Options
• Dynamic Braking resistor (external)
• Multi-lingual, full-text remote LCD w/ copy
• Profibus-DP, DeviceNet Communications
• Modbus TCP/IP, EtherNet/IP Communications
• DriveWizardTM Plus
• CASE software
• DIN rail mounting kit
• Y-Stick Copy Unit
Standards
• UL 508C (Power Conversion)
• CSA 22.2 No. 14-95 (Industrial Control Equipment)
• UL, cUL listed; CE marked
• RoHS compliant
• EN 50178 (LVD)
• EN 50081-2, EN 50082-2 (EMC)
• EN 954-1, Category 3 Safety Standard
• EN 61800-3
• IEC 529, 146
• FCC CFR 47 Part 15 Subpart B (w/ External Filter)
• TUV
Page 1
Data subject to change without notice
PB.V1000.01, 8/1/07
Yaskawa Electric Americ
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
V1000
List Prices
V1000 Drive
Rated
Input
Voltage
200 - 240V
1-Phase
200 - 240V
3-Phase
380 - 480V
3-Phase
Drive Model
Number
CIMR-VU
BA0001FA BA0002FA BA0003FA BA0006FA BA0010FA BA0012FA BA0018FA
2A0001FA 2A0002FA 2A0004FA 2A0006FA 2A0010FA 2A0012FA 2A0020FA 2A0030FA 2A0040FA 2A0056FA 2A0069FA 4A0001FA 4A0002FA 4A0004FA 4A0005FA 4A0007FA 4A0009FA 4A0011FA 4A0018FA 4A0023FA 4A0031FA 4A0038FAA
Normal Duty
Rated Output
Current
(Amps)
(1)
Nominal HP
(2)
Rated Output
Heavy Duty
Current
(Amps)
1.2 1/8 & 1/4 0.8 1/8
1.9 1/4 1.6 1/4
3.3 1/2 & 3/4 3.0 1/2
6.0 1 5.0 3/4 & 1
9.6 2 & 3 8.0 2
12.0 3 11.0 3
17.5 5 17.5 5
1.2
1/8 & 1/4
0.8
1.9 1/4 1.6 1/4
3.5 1/2 & 3/4 3.0 1/2
6.0 1 5.0 3/4 & 1
9.6 2 & 3 8.0 2
12.0 3 11.0 3
19.6 5 17.5 5
30.0 7.5 & 10 25.0 7.5
40.0 10 33.0 10
56.0 20 47.0 15
69.0 25 60.0 20
1.2 1/2 1.2 1/2
2.1 3/4 & 1 1.8 3/4
4.1 2 3.4 1 & 2
5.4 3 4.8 3
6.9 4 5.5 3
8.8 5 7.2 4
11.1 7.5 9.2 5
17.5 10 14.8
24.0 15 18.0 10
31.0 20 24.0
38.0 25 31.0 20
(1)
Nominal HP
1/8
7.5 & 10
15
(2)
Drive List
Price $
(1) Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds (2) Horsepower rating is based on standard NEMA B 4-pole motor design and NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors