Yaskawa V1000-4X Product Flyer

V1000-4X
1/8 to 25 HP NEMA 4X Current Vector Microdrive
Washdown - Dust Tight!
The V1000-4X is a version of the standard V1000 in an integral enclosure that meets NEMA type 4X/12 indoor use requirements, UL type 4X/12 standards, and the IP66 rating of IEC 60529. This enclosure provides the protection required in tough washdown or dust-tight environments, common in Food and Beverage Processing, Packaging, Metal Machining, Woodworking, Pumping, Refrigeration, and Printing. The enclosure is epoxy-coated to protect against the harmful effects of sanitizing chemicals commonly used in food industries.
Specifications
Item Specication
Overload Capacity
Output Frequency 0~400 Hz (higher frequencies available with custom software)
Control Methods
Protective Design NEMA Type 4X/IP66 (dust/water-proof)
Braking Transistor Standard in all models
Braking Torque 20 - 40% increase with intelligent high-slip braking function
KEB Function
Overvoltage Function
Maintenance
Global Certication CE, UL, cUL, RoHS, TUV
Available I/O
Network Communication
Keypad Operator
150% Overload for 60 sec. (Heavy Duty)
120% Overload for 60 sec. (Normal Duty)
Open Loop Current Vector Control, V/f Control, PM Open Loop Vector Control
Simple closed loop speed control available
Uses mechanical energy to continue operation during momentary power failure, standard
Prevention function for die-cushion in a hydraulic mechanical press and other applications
Elapsed timer assists in preventative maintenance for cooling fan, capacitors, and transistors
Easily replaceable cooling fan
(7) multi-function digital inputs
(1) hardwire baseblock
(2) multi-function analog inputs
(1) multi-function pulse input
(1) multi-function relay output
(2) multi-function photo-coupler outputs
(1) multi-function 0-10 Vdc analog output
(1) multi-function pulse output
Standard: RS-422/485 MODBUS 115 kbps
Optional: DeviceNet, EtherCAT, EtherNet/IP, MECHATROLINK-II, MECHATROLINK-III, Modbus TCP/IP, PROFIBUS-DP, PROFINET
Standard LED 5 digit display
Optional multi-lingual, full-text remote LCD
Features
• NEMA Type 4X/IP66 enclosure
• Corrosion-resistant
• Current vector control, open loop
• RoHS compliance
• On-line tuning
• Induction motor (IM) or permanent
magnet synchronous motor (PM) operation
• Function Block Diagram (FBD) programming via DriveWorksEZ™
• Starting torque of 200% at 0.5 Hz
• Removable terminal block with
parameter backup function
• “One-touch” copy function with verify
• Super-fast 2 ms scan cycle with dual CPU
• EN954-1 Safety Cat. 3, Stop Cat. 0
• Increased vibration resistance, from
20 Hz to 50 Hz (0.65G)
• 1 in 10,000 failure rate
• Swing PWM function to decrease
noise at low carrier frequencies
• Pre-maintenance function
• Modbus communication
•
MTBF: 28 years
• Short Circuit Current Rating (SCCR): 30kA rms symmetrical
• Common programming with all other Yaskawa drives
Yaskawa America, Inc.
Drives & Motion Division
V1000-4X
Beverage
Conveyor
Refrigeration
1/8 to 25 HP
200-240V / Single-Phase
Model
Number
CIMR-VU
BA0001GAA 1.2 1/4 0.8 1/8
BA0003GAA 3.3 3/4 3.0 1/2
BA0006GAA 6.0 1 5.0 1
BA0012GAA 12.0 3 11.0 3
Normal Duty Heavy Duty Dimensions (in.)
Rated
Output Current (Amps)
Rated
Output
HP
Current (Amps)
HP H W D
6.38 8.74 7.28BA0002GAA 1.9 1/4 1.6 1/4
7.36 10.04 9.25BA0010GAA 9.6 3 8.0 2
200-240V / Three-Phase
Model
Number
CIMR-VU
2A0001GAA 1.2 1/4 0.8 1/8
2A0002GAA 1.9 1/4 1.6 1/4
2A0004GAA 3.5 3/4 3.0 1/2
2A0006GAA 6.0 1 5.0 1
2A0010GAA 9.6 3 8.0 2
2A0020GAA 19.6 5 17.5 5
2A0030GAA 30 10 25 7.5
2A0040GAA 40 10 33 10
2A0056GAA 56 20 47 15
2A0069GAA 69 25 60 20 18.31
Normal Duty Heavy Duty Dimensions (in.)
Rated
Output Current (Amps)
Rated
Output
HP
Current (Amps)
HP H W D
6.38 8.74 7.28
7.36 10.04 9.252A0012GAA 12.0 3 11.0 3
11.42
16.54
12.01
Major Applications
Food &
Packaging
Industrial Washer
Size Comparison
H
18.31”
16.54”
10.04”
8.74”
Normal Duty, NEMA Type 4X/IP66
2 HP 480V
7.5 HP 480V
Pump
25 HP
240V
25 HP
480V
380-480V / Three-Phase
Model
Number
CIMR-VU
4A0001GAA 1.2 1/2 1.2 1/2
4A0004GAA 4.1 2 3.4 2
4A0005GAA 5.4 3 4.8 3
4A0007GAA 6.9 4 5.5 3
4A0009GAA 8.8 5 7.2 4
4A0011GAA 11.1 7.5 9.2 5
4A0018GAA 17.5 10 14.8 10
4A0023GAA 23 15 18 10
4A0031GAA 31 20 24 15
2A0038GAA 38 25 31 20
Normal Duty Heavy Duty Dimensions (in.)
Rated
Output Current (Amps)
Rated
Output
HP
Current (Amps)
HP H W D
6.38 8.74 7.284A0002GAA 2.1 1 1.8 3/4
7.36 10.04 9.25
11.42 16.54 12.01
Yaskawa America, Inc.
Drives & Motion Division
0
6.38” 7.36” 11.42 ”
W
Not drawn to scale
Options*
•120VACInterface
•
Network Communications: DeviceNet, EtherCAT, EtherNet/IP, MECHATROLINK-II, MECHATROLINK-III, Modbus TCP/IP, PROFIBUS-DP, PROFINET
* Although the V1000-4X is compatible with most V1000
options, those options may not be waterproof. These options require special consideration regarding proper wiring techniques, including cable glands.
Document Number: FL.V1000-4X.01 • 04/29/2015 • © 2015