Digital Operator Remote Mount Option Kits
Part Numbers: UUX000458 (blank overlay), UUX000459 (Yaskawa logo ov erlay).
Applicability: F7, G7, P7, E7
Introduction: This kit is designed to provide the functionality of the digital operator on an enclosure designed for a NEMA Type 1,
3R, 4, 4X, 12, or IPX6 environment. Refer to UL file number E131457 for details. This guide is divided into three sections detailing
the kit parts, chemical resistance, and kit installation.
HAZARDOUS VOLTAGE CAN CAUSE SEVERE INJURY OR DEATH. LOCK ALL POWER SOURCES TO THE DRIVE
IN THE “OFF” POSITION.
• To prevent physical damage to the Drive, read these instructions thoroughly before installing.
• Partially tighten and torque all hardware prior to tightening to the rated torque specifications.
• Tighten the screws in a cross-like pattern to prevent damage to the threads.
• Do not exceed the recommended torque values as described in the instructions.
Receiving: Unpack the option kit and verify that all components are present and undamaged.
Included Part List (Either Kit) Quantity
Installation Guide (IG.AFD.72) 1
1:1 Cutout Template (UDM00201) 1
Mounting Bracket Subassembly 1
M3 x 6 screw 2
Operator Z-Bracket 2
#8-32 nut w/captive washer 4
#10-32 nut w/captive washer 6
Digital Operator Cable 3ft 1
Digital Operator Cable 10ft 1
Note: Please carefully remove the protective pink plastic from the mounting bracket membrane prior to kit installation.
WARNING
CAUTION
UUX000458, UUX000459
Yaskawa Electric America, Inc – www.drives.com
IG.AFD.72, Page 1 of 4
Date: 6/14/07, Rev: 07-06
Digital Operator Remote Mount Option Kits
Chemical Resistance: The materials used in this kit were chosen specifically for resistance to harsh environments. This kit
provides short-term protection from many chemicals, including the list below. For additional information, please contact the factory.
• Toluene
• Isopropyl Alcohol
• Cyclohexanone
• Ethyl Acetate
• Xylene
• 40% NaOH
• Concentrated HCl
• Gasoline
• Butyl Cellosolve
Kit Installation:
1. Turn off power to the drive by completely removing power to the enclosure. Wait 5 minutes for capacitor discharge.
2. Unpack and verify the contents of the Digital Operator Remote Mount Kit.
3. Create the cutout at the desired location on end-use enclosure as shown below. Please use the 1:1 cutout template
(drawing UDM00201) included in this kit. Note that 3.0” clearance is required behind the operator kit to allow for cable
routing. All dimensions +/- 0.03”.
UUX000458, UUX000459
Figure 1a – Cutout Drawing Figure 1b – Side Assembly View Showing Recommended
Bending Radius (Depth)
Yaskawa Electric America, Inc – www.drives.com
IG.AFD.72, Page 2 of 4
Date: 6/14/07, Rev: 07-06