Analog Voltage/Pulse Train Reference Type SERVOPACKs
SGDV-¡¡¡¡01
(For Rotary Servomotors)
SGDV-¡¡¡¡05
(For Linear Servomotors)
Model Designations
SGDV - R70 A 01 A
Options
233
Code Specifications
Series
v
SGDV SERVOPACK
Voltage
Code Specifications
F 100 VAC
A 200 VAC
D 400 VAC
Current
Code
R70 0.05 R70* 0.05 1R9 0.5
R90 0.1 R90* 0.1 3R5 1.0
2R1 0.2 1R6* 0.2 5R4 1.5
2R8 0.4 2R8* 0.4 8R4 2.0
100 V (Single Phase)
Applicable Servomotor Max. Capacity kW Applicable Servomotor Max. Capacity kW Applicable Servomotor Max. Capacity kW
Code
3R8 0.5 120 3.0
5R5* 0.75 170 5.0
7R6 1.0 210 6.0
120♣ 1.5 260 7.5
180 2.0 280 11
200 3.0 370 15
330 5.0
470 6.0
550 7.5
590 11
780 15
200 V (Three Phase)
Blank Base-mounted (standard)
001000 Rack-mounted*
*: SGDV-470A, -550A, -590A, -780A SERVOPACKs are
duct-ventilated.
Design Revision Order
A, B…
Interface
Code Specifications
Analog voltage/pulse train reference type
01
(for rotary servomotors)
Analog voltage/pulse train reference type
05
(for linear servomotors)
Code
NOTE: Shaded items are non-stock.
* These amplifiers can be powered with single or three-phase.
♣ SGDV-120A¡¡A008000, a special version of the 1.5kW
amplifier can be used for single-phase operation.
400 V (Three Phase)
Features
1Unprecedented ease-of-use through cutting-edge technology
1Slashed setup time
1High response characteristics at 1 kHz min.
SGLGW
•
New tuning-less function means no adjustment needed.
•
Impressive load regulation with strengthened vibration suppression function.
Setup wizard function and wiring conformation function of engineering tool SigmaWin+ allows
•
easy setup just by watching the monitor.
New advanced autotuning.
•
Reduced positioning time through model following control, and smooth machine control enabled
•
by vibration suppression function.
Ratings
Single-phase 100 V
SERVOPACK Model SGDV-¡¡¡¡
Applicable Servomotor Max. Capacity kW
Continuous Output Current A
Max. Output Current A
Main Circuit
Control Circuit
Three-phase 200 V
SERVOPACK Model SGDV-¡¡¡¡
Applicable Servomotor Max. Capacity kW
Continuous Output Current A
Max. Output Current A
Main Circuit
Control Circuit
Three-phase 400 V
SERVOPACK Model SGDV-¡¡¡¡
Applicable Servomotor Max. Capacity kW
Continuous Output Current A
Max. Output Current A
Main Circuit
Control Circuit
1SERVOPACK Overload Characteristics
10000
)
s
1000
(
100
Detecting time
10
1
100 200 300 350
Torque reference(percent of rated torque
Note: Overload characteristics shown above do not guarantee continuous duty of 100% or more output. Use a servomotor with effective torque within
the continuous duty zone of Torque-Motor Speed Characteristics.
SGMJV
(%)
R70F R90F 2R1F 2R8F
0.05 0.1 0.2 0.4
rms
rms
0.66 0.91 2.1 2.8
2.1 2.9 6.5 9.3
Single-phase 100 to 115 VAC
Single-phase 100 to 115 VAC
+
10% to −15% 50/60 Hz
+
10% to −15% 50/60 Hz
R70A R90A 1R6A 2R8A 3R8A 5R5A 7R6A 120A 180A 200A 330A 470A 550A 590A 780A
0.05 0.1 0.2 0.4 0.5 0.75 1.0 1.5 2.0 3.0 5.0 6 7.5 11 15
0.66 0.91 1.6 2.8 3.8 5.5 7.6 11.6 18.5 19.6 32.9 46.9 54.7 58.6 78
rms
2.1 2.9 6.5 9.3 11 16.9 17 28 42 56 84 110 130 140 170
rms
Three-phase 200 to 230 VAC
Single-phase 200 to 230 VAC
+
10% to −15% 50/60 Hz
+
10% to −15% 50/60 Hz
1R9D 3R5D 5R4D 8R4D 120D 170D 210D 260D 280D 370D
0.5 1.0 1.5 2.0 3.0 5.0 6 7.5 11 15
1.9 3.5 5.4 8.4 11.9 16.5 20.8 25.4 28.1 37.2
rms
5.5 8.5 14 20 28 42 55 65 70 85
rms
24 VDC
10000
)
1000
s
(
Detecting time
Rated
torque
+
10% to −15% 50/60 Hz
15%
±
SGMGV-03A, -05A, -09A,
-
SGMGVSGMSV-
100
10
SGMGV-44A,
1
Approx.
-55A,
-75A
Rated torque + Max. torque
13
A, -20A, -30A,
1
AA, -1EA
□□
D
□□□
2
)
Three-phase 380 to 480 VAC
10000
)
1000
s
(
100
Detecting time
10
1
100 200 300
Torque reference(percent of rated torque
SGMAV-02, 04, 06,
SGMPS
SGMAV-A5, 01, C
(%)
2
08,10
)
Max.
torque
Analog/Pulse Type SERVOPACKs
234