BnH = Control event (n = channel number)
ccH = Control number
vvH = Data Range
(1) All Sound Off
ccHParameterData Range (vvH)
78HAll Sound Off00H
(2) Reset All Controllers
ccHParameterData Range (vvH)
79HReset All Controllers 00H
Resets controllers as follows.
ControllerValue
Expression127 (max)
Damper Pedal0 (off)
Sostenuto0 (off)
Soft Pedal0 (off)
(3) Local Control (reception only)
ccHParameterData Range (vvH)
7AHLocal Control00H (off), 7FH (on)
(4) All Notes Off
ccHParameterData Range (vvH)
7BHAll Notes Off00H
Switches OFF all the notes that are currently ON on the specified channel. Any notes being held by the damper or sostenuto pedal will continue to sound until the pedal is released.
(5) Omni Off (reception only)
ccHParameterData Range (vvH)
7CHOmni Off00H
Same processing as for All Notes Off.
(6) Omni On (reception only)
ccHParameterData Range (vvH)
7DHOmni On00H
Same processing as for All Notes Off.
(7) Mono (reception only)
ccHParameterData Range (vvH)
7EHMono00H
Same processing as for All Sound Off.
(8) Poly (reception only)
ccHParameterData Range (vvH)
7FHPoly00H
Same processing as for All Sound Off.
• When Control Change is turned OFF, Control Change messages will not be transmitted or received.
• Local on/off, OMNI on/off are not transmitted. (The appropriate
note off number is supplied with “All Note Off” transmission).
• When a voice bank MSB/LSB is received, the number is
stored in the internal buffer regardless of the received order,
then the stored value is used to select the appropriate voice
when a program change message is received.
• Poly mode is always active. This mode will not change when
the instrument receives MONO/POLY mode message.
YDP-161/141 Data List / Daten-Liste / Liste des données / Lista de datos
2
Page 3
4. PROGRAM CHANGE
Data format: [CnH] ➝ [ppH]
CnH = Program event (n = channel number)
ppH = Program change number
P.C.#=Program Change number
YDP-161MSBLSB
Grand Piano 101221
Grand Piano 201121
E.Piano 101226
E.Piano 201225
Harpsichord 101227
Harpsichord 201237
Vibraphone012212
Church Organ 1012320
Church Organ 2012220
Strings012249
YDP-141MSBLSB
Grand Piano 101221
Grand Piano 201121
E.Piano 101226
Harpsichord01227
Church Organ012320
Strings012249
P. C. #
P. C. #
• When program change reception is turned OFF, no program
change data is transmitted or received.
• When you specify a program change as a number in the
range of 0-127, specify a number that is one less than the program change number listed above. For example, to specify
program change number 1, you would specify program
change 0.
5. Pitch Bend Change
[EnH]➝[ccH]➝[ddH]
ccH = LSB
ddH = MSB
6. SYSTEM REALTIME MESSAGES
[rrH]
F8H: Timing clock
FAH : S t a r t
FCH: Stop
FEH: Active sensing
DataTransmissionReception
F8H
FAHSong start
FCHSong stop
FEH
Transmitted every
96 clocks
Transmitted every
200 milliseconds
• If an error occurs during MIDI reception, the Damper, Sostenuto, and Soft effects for all channels are turned off and an All
Note Off occurs.
Received as 96-clock tempo timing
when MIDI clock is set to External.
Song start
Not received when the MIDI clock is
set to Internal.
Song stop
Not received when the MIDI clock is
set to Internal.
If a signal is not received via MIDI for
more than 400 milliseconds, the same
processing will take place for All
Sound Off, All Notes Off and Reset All
Controllers as when those signals are
received.
7. SYSTEM EXCLUSIVE MESSAGES
(Universal System Exclusive)
F0H = Exclusive status
7EH = Universal Non-Realtime
7FH = ID of target device
09H = Sub-ID #1=General MIDI Message
01H = Sub-ID #2=General MIDI On
F7H = End of Exclusive
or
F0H = Exclusive status
7EH = Universal Non-Realtime
XnH = When received, n=0~F.
09H = Sub-ID #1=General MIDI Message
01H = Sub-ID #2=General MIDI On
F7H = End of Exclusive
When the General MIDI mode ON message is received, the
MIDI system will be reset to its default settings.
This message requires approximately 50ms to execute, so
sufficient time should be allowed before the next message is
sent.
[llH] ➝ [mmH] ➝ [F7H]
Volume MSB
X = don’t care
Volume MSB
[F7H]
X = don’t care
YDP-161/141 Data List / Daten-Liste / Liste des données / Lista de datos
F0H = Exclusive status
43H = YAMAHA ID
1nH = When received, n=0~F.
4CH = Model ID of XG
hhH = Address High
mmH =
llH = Address Low
ddH = Data
|
F7H = End of Exclusive
Data size must match parameter size (2 or 4 bytes).
When the XG System On message is received, the MIDI system will be reset to its default settings.
The message requires approximately 50ms to execute, so
sufficient time should be allowed before the next message is
sent.
F0H = Exclusive status
43H = YAMAHA ID
0nH = When received, n=0~F.
4CH = Model ID of XG
aaH = ByteCount
bbH = ByteCount
hhH = Address High
mmH =
llH = Address Low
ddH = Data
| |
| |
ccH = Check sum
F7H = End of Exclusive
• Receipt of the XG SYSTEM ON message causes reinitialization of relevant parameters and Control Change values. Allow
sufficient time for processing to execute (about 50 msec)
before sending this instrument another message.
• XG Native Parameter Change message may contain two or
four bytes of parameter data (depending on the parameter
size).
• For information about the Address and Byte Count values,
refer to Table 1 below. Note that the table’s Total Size value
gives the size of a bulk block. Only the top address of the
block (00H, 00H, 00H) is valid as a bulk data address.
Master Tuning (XG and last message priority) simultaneously
changes the pitch of all channels.
F0H = Exclusive Status
43H = Yamaha ID
1nH = When received, n=0~F.
27H = Model ID of TG100
30H = Sub ID
00H=
00H=
mmH = Master Tune MSB
llH = Master Tune LSB
ccH = don’t care (under 7FH)
F7H = End of Exclusive
[F0H] ➝ [43H] ➝ [1nH] ➝ [27H] ➝ [30H] ➝
➝
[00H] ➝ [mmH] ➝ [llH] ➝ [ccH] ➝
[00H]
[F7H]
When transmitted, n=0.
9. SYSTEM EXCLUSIVE MESSAGES
(Digital Piano MIDI Format)
Data format:
F0H = Exclusive status
43H = Yamaha ID
73H = Digital Piano ID
01H = Product ID (digital piano common)
xxH = Substatus
F7H = End of Exclusive
YDP-161/141 Data List / Daten-Liste / Liste des données / Lista de datos
4
[F0H] ➝ [43H] ➝ [73H] ➝ [xxH] ➝ [nnH] ➝
[F7H]
nnControl
02HInternal MIDI clock
03HExternal MIDI clock
06HBulk Data (the bulk data follows 06H)
Page 5
<Table 1>
MIDI Parameter Change table (SYSTEM)
Address (H) Size (H)Data (H)ParameterDescriptionDefault value (H)
00 00 004020C - 05F4(*1)MASTER TUNE-50 - +50[cent]00 04 00 00
011st bit 3 - 0 ➝ bit 15 - 12400
022nd bit 3 - 0 ➝ bit 11 - 8
033rd bit 3 - 0 ➝ bit 7 - 4
04100 - 7FMASTER VOLUME0 - 1277F
7E00XG SYSTEM ON00=XG sytem ON
7F00RESET ALL PARAMETERS00=ON (receive only)
TOTAL SIZE 07
*1: Values lower than 020CH select -50 cents. Values higher than 05F4H select +50 cents.
4th bit 3 - 0 ➝ bit 3 - 0
<Table 2>
MIDI Parameter Change table (EFFECT 1)
Refer to the “Effect MIDI Map” for a complete list of Reverb, Chorus and Variation type numbers.
Address (H) Size (H)Data (H)ParameterDescriptionDefault value (H)
02 01 00200 - 7FREVERB TYPE MSBRefer to Effect MIDI Map01(=HALL1)
00 - 7FREVERB TYPE LSB00 : basic type00
02 01 20200 - 7FCHORUS TYPE MSBRefer to Effect MIDI Map00(=Effect off)
• “VARIATION” refers to the EFFECT on the panel.
00 - 7FCHORUS TYPE LSB00 : basic type00
<Table 3>
MIDI Parameter Change table (MULTI PART)
Address (H) Size (H)Data (H)ParameterDescriptionDefault value (H)
08 nn 11100 - 7FDRY LEVEL0 - 1277F
08 nn 0C100 - 7FVELOCITY SENSE DEPTH0 - 12740
08 nn 0D100 - 7FVELOCITY SENSE OFFSET 0 - 12740
nn = Part Number
• Effect MIDI Map
REVERB
MSBLSB
ROOM02H10H
HALL 101H10H
HALL 201H11H
STAGE03H10H
OFF00H00H