Yale 781N Installation Instructions Manual

781N Electric Latch Pullback Controller
Installation Instructions
INSTALLATION
For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code. Transformer model BE31763001 by Basler Electric and transformer model 2010028 by Galaxy Transformer and Magnetics have been certified for UL and C-UL applications. Transformer model A41-130-28A34 by EWC has been certified for UL applications only.
For the 120VAC power input, terminal block TB1 will accommodate up to 12 AWG wire (solid). Conduit must be used to provide an adequate earth ground to the enclosure.
NOTE: The maximum input current is 750mA.
The 781N is designed to be used with electric latch pullback exit devices. Use the chart below to determine the correct wire gauge per given length of two-conductor cable that will be run from the 781N to each exit device. Do not exceed the maximum length listed with each wire gauge.
WIRE GAUGE MAXIMUM LENGTH OF TWO-CONDUCTOR CABLE
16 AWG 40 FEET 14 AWG 60 FEET 12 AWG 100 FEET
Up to two devices can be used with the 781N. If only one device is to be used, wire to the "DEVICE ONE" location at TB3, terminals 5 and 6.
NOTE: Be sure to observe polarity when connecting devices 1 and 2 to TB3.
(Refer to the wiring diagram located on the lid of the controller.)
An ASSA ABLOY Group brand
80-9477-0781-010 (01-13)
STANDARD OPERATION
The 781N provides a choice of two methods of electric latch pullback: Single System or Dual System
SINGLE SYSTEM LATCH PULLBACK
This method allows one input to control two devices sequentially. A momentary switch closure across terminals 1 and 2 of TB3 will pull back DEVICE ONE first, followed by DEVICE TWO. Use this method for single door applications or on a pair of doors using a device on one or both leaves. The 781N comes from the factory already set up for this method.
DUAL SYSTEM LATCH PULLBACK (OPTIONAL)
This method allows independent control of DEVICE ONE and DEVICE TWO outputs by their own separate input. A momentary switch closure across terminals 1 and 2 of TB3 will pull back DEVICE ONE only. A momentary switch closure across terminals 7 and 8 of TB3 will pull back DEVICE TWO. No more than one device can be used per output. Use this option for applications requiring two single door systems or two pair door systems using one device on the active leaf of each pair of doors. To change over to the optional dual system latch pullback, move the program jumper PJ1 from between the middle post and the end post, marked "S" (Single System) to between the middle post and the end post, marked "D" (Dual System).
NOTE: When using the optional method, DEVICE ONE and DEVICE TWO can never be activated
at the same time in the event that both input switches are actuated simultaneously. If this should occur, DEVICE ONE will always activate first, followed by DEVICE TWO.
When using a momentary, normally open switch for activating latch pullback, adjust pot R2 (for DEVICE ONE) or pot R4 (for DEVICE TWO) on the p.c. board to the desired latch pullback delay time from 1 to 20 seconds. Turn the pot clockwise to increase the delay time.
When using normally open contacts from a keypad or card reader ( with built-in time delay) or a maintain switch, turn pot R2 (or R4) fully counterclockwise to the minimum delay time (approx. 0.5 sec.). A contact closure will activate latch pullback. Upon opening of the timed or maintained contacts, the device will latch within 0.5 second.
Each modified exit device contains a pulse module which delivers a pulse at approx. 24VDC to a high current coil inside the exit device every 6 seconds until the latch is finally pulled back all the way. At this point, a control rod passes over a reflective sensor and signals the module to stop pulsing. There is always an initial pulse that occurs at the moment the system is activated. During the period the system remains activated, output voltage is applied to a low current secondary coil. This coil is responsible for holding the latch in the "pulled back" position until instructed to return to the "fail secure" position. (See note 2 on page 5.)