7110(F), 7170(F)(LBR)
Surface Vertical Rod Exit Device Series
Installation Instructions
Strike Angle Must
Shim (2) Supplied
Strike Plate
Engage Strike
726
Top Strike
Top Mounting Plate
(2) 1/4-20 X 3/4" PFHMS
(Metal Door)
or
(2) #14 x 1-1/2" PFH”AB”SMS
(Wood Door)
Rod Guide
(2) #8 x 1/2" (13mm) PRH”AB”SMS
Top Rod
Roll Pin
Bottom Rod Assembly
Rod Guide
(2) #8 x 1/2" (13mm) PRH”AB”SMS
Bottom Mounting Plate
(2) 1/4-20 X 3/4" PFHMS
(Metal Door)
or
(2) #14 x 1-1/2" PFH”AB”SMS
(Wood Door)
790 Strike
791 Strike
(3) 10-24 x 3/4" (19mm) PFHMS
Top Latch
(Panic & Fire Label)
(3) 10-24 x 1/4" (6mm) PPHMS
(2) 8-32 x 1/4" (6mm) PFHMS
Latch Cover
(2) #6 x 3/8" (10mm) PTH”AB”SMS
‘
Guide Cover
Top Rod Connector
(2) 1/4-20 X 1" PPHMS
(Metal Door)
or
(2) #14 x 1-1/2" PPH”AB”SMS
(Wood Door)
(2) 8-32 x 5/16" (8mm) PFHUMS
(2) #6 x 3/8" (10mm)
ABBREVIATION
PTH”AB”SMS
Guide Cover
Deadbolt
Bottom Bolt Case
Panic & Fire Label
(3) 10-24 x 1/4" (6mm)
PPHMS
(2) 8-32 x 1/4" (6mm) PFHMS
Bolt Case Cover
12-24
PRHMS
Top bracket and 726 strike
required for 7170(F)(LBR).
End Clamp
(3) 8-32 x 5/16"
PFHUMS
End Cap
(2) 1/4-20 X 1" PPHMS
(Metal Door)
(2) #14 x 1-1/2" PPH”AB”SMS
or
(Wood Door)
Hole Plug
(Fire Label Devices)
Dogging Key
Dogging
Feature to hold bolts retracted and
touchpad depressed, for push-pull door
To Dog Device
1. Insert dogging key.
2. Hold touchbar depressed.
3. Turn key 1/4 turn clockwise.
(Not a feature of fire labeled devices.)
Cover
FASTENER DESCRIPTION
PPH”AB”SMS
PFHUMS
PFHMS
PRH”AB”SMS
PTH”AB”SMS PHILLIPS TRUSS HEAD TYPE “AB” SHEET METAL SCREW
PPHMS PHILLIPS PAN HEAD MACHINE SCREW
PFH”AB”SMS
PRHMS PHILLIPS ROUND HEAD METAL SCREW
PHILLIPS PAN HEAD TYPE “AB” SHEET METAL SCREW
PHILLIPS FLAT HEAD UNDER CUT MACHINE SCREW
PHILLIPS FLAT HEAD MACHINE SCREW
PHILLIPS ROUND HEAD TYPE “AB” SHEET METAL SCREW
PHILLIPS FLAT HEAD TYPE “AB” SHEET METAL SCREW
All dimensions are in inches (mm) unless otherwise noted.
operation.
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)

To Change Hands
Maintenance
RHR Device
Vertical Lifter Assembly
(4) 8-32 x 3/16" PPHMS
Remove (4) Screws and
Vertical Lifter Assembly.
Rotate device to opposite
hand (180 degrees). Insert
Lifter Assembly under Lift
Block and re-install screws.
Lift Block
Vertical Lifter Assembly
(4) 8-32 x 3/16" PPHMS
LHR DoorRHR Door
Check Before Starting
Unreinforced Doors or Frames
Doors and Frames with walls having a structural
thickness (metal skin plus reinforcement or solid
hardwood) to engage less than (3) full screw threads
are considered unreinforced.
Unreinforced Doors: Use SNB (sex nuts and bolts).
Unreinforced Frames: Use Blind Rivet Nuts.
Recommended fasteners for unreinforced openings
are not necessarily supplied by Yale Locks and
Hardware.
LHR Device
1. Periodically remove covers and coat mechanisms with a
silicone base lubricant. This is particularly required in corrosive
environments for proper product function.
2. Check mounting fasteners periodically. Retighten if found
loose. Apply screw locking compound (available at automotive
part stores) or change part fasteners if screws continue to back
out.
3. Periodic checks (and adjustments) of strikes are required to
compensate for changes in the opening (e.g. door sagging).
Min. Door Stile
4-1/2" (114mm)
Door and frame must
meet structural and
dimensional specifications
on exit device template(s)
for door and frame
preparation.
Reinforcement
Door Skin
Blind Rivet Nut
Door Must Swing Freely
1. Mark Door
Single Door or Pair without Mullion
Locate and Mark Horizontal and Vertical Reference Centerlines as shown.
LHR door shown, preparation is typical for both door hands.
Note: Door should be in the closed position while marking horizontal and
vertical reference lines. Paper or the Plastic Template may be used in this step.
FINISHED
FLOOR
or THRESHOLD
2. Prepare Door, Frame, & Sill
A. Locate “Device Template” aligning VERTICAL REFERENCE and HORIZONTAL
REFERENCE lines. Tape template to door face.
B. Extend centerline of Rod and Strikes from “Device Template” to door top and
bottom, on door face.
C. Locate Top Latch/Strike and Bottom Bolt Case templates in place over centerline
of Rods and Strikes on door. Tape templates in place and mark holes.
Note that the centerline of the rods and strikes used to install top and bottom bolts
is not the Vertical Reference centerline.
D. Locate and tape Trim Template to door when required (See instructions packed with Trim).
E. Mark and prepare holes per installation template (exclude 791 or 726 strike, holes
prepared in Step 7).
F. Locate 790 Bottom Strike Template. Tape in place over Rods and Strikes centerline
on door. Tape template in place and mark hole locations. Holes to be prepared in Step 7.
G. Remove templates from door.
op Latch & 791or 726
T
LHR DOOR
INSIDE FACE
VERTICAL
REFERENCE
HORIZONTAL
39-15/16
(1014)
emplate
ike T
Str
Device Template
Bottom Case
Template
Floor Strike Template
FINISHED FLOOR or THRESHOLD
REFERENCE
LHR DOOR
INSIDE FACE
Rods & Strikes
VERTICAL
REFERENCE
HORIZONTAL
REFERENCE
2
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)

3. Size Device
Device must be field cut to size, as required
* LHR Door (Door Open)
inside face
STILE
Horizontal line
C
L
Dogging
Hole
4. Mount Device & Components
Note: 726 Strike and top
bracket not shown.
Top
Mounting
Plate
Top
Latch
16-3/8
(416)
791 Strike
D
1-3/8
(35)
3/8
(10)
HINGE SIDE OF DOOR
Min.
Min.
CUT
LINE
STOP
SURFACE
2-1/4
(57)
Determine device length
1. Close door. Measure 2-1/4" (57mm)
from the Stop Surface on the hinge side of
the door, mark Horizontal Reference at
this point.
Note: This dimension must be 3/8"
(10mm) minimum from edge of the stile
on the door.
2. Open door. Align mounting holes in
device with Mounting Holes in the door.
Mark device where it crosses the mark
from Step 1. If mark is less than 1-3/8"
(35mm) min. from Dogging Hole, a shorter
device is required.
3. Before cutting, make sure the End
Cover is in place and there is no gap
between it and the Pushpad. Cut device
on mark from Step 2.
(2) 1/4-20 x 3/4" (19mm)
PFHMS
F
C
L
B
C
Device Mounting Holes,
L
Rods, & Strikes
Rod Guide
F
15
(381)
D
Bottom Bolt
Case
790 Strike
Rod Guide
Bottom
Mounting
(3) 10-24 x 1/4" (6mm)
PPHMS
Plate
(2) 1/4-20 x 3/4" (19mm)
PFHMS
Bottom Bolt
Case
End
Clamp
C
1/2
vice
De
(3) 10-24 x 1-1/4" (32mm)
PPHMS
(13)
Figure 3.
An ASSA ABLOY Group brand
3
80-9470-0010-000 (03-13)