Xtramus NuStreams-P6GW User Manual

Page 1
NuStreams-P6GW
USM Ver 1.0
Page 2
Foreword
Copyright
Copyright © 2011 Xtramus Technologies, all rights reserved. The information contained in this document is the property of Xtramus Technologies. No part of this publication shall be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, without the prior written permission of Xtramus Technologies.
Disclaimer
The information contained in this document is subject to change without notice and does not represent a commitment on the part of Xtramus Technologies. The information in this document is believed to be accurate and reliable. However, Xtramus Technologies assumes no responsibility or liability for any errors or inaccuracies that may appear in the document.
Trademarks NuStreams-P6GW, NuSet-MiniPG, NuSet-MiniPG-Config, NuSet-MiniPG-ST and NuSet-MiniPG-UG are trademarks or
registered trademarks of Xtramus Technologies. All other trademarks and registered trademarks are the property of their respective owners.
Warranty
Xtramus Technologies warrants for the hardware provided along with this document under proper usage and conditions in normal environment; any improper operation or in irregular environment may possibly ca use this product NOT function well. For detailed terms, please contact your local dealer.
Contact Information
Xtramus Technologies E-mail: sales@xtramus.com Website: www.xtramus.com Tel: +886-2-8227-6611 Fax: +886-2-8227-6622
2
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 3
Revision History
Date Version History
2011/10/14 Ver 1.0 First draft version
3
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 4
Table of Contents
Foreword..........................................................................................................................................2
Revision History..............................................................................................................................3
1. NuStreams-P6GW Overview.......................................................................................................6
1.1. NuStreams-P6GW General Description............................................................................6
1.2. Key Features of NuStreams-P6GW...................................................................................7
1.3. NuPAD Overview ................................................................................................................7
2. NuStreams-P6GW Function Overview.......................................................................................8
2.1. NuStreams-P6GW Interface Ports.....................................................................................8
2.2. NuStreams-P6GW Front Panel – LCD & LEDs.................................................................9
2.3. NuStreams-P6GW Front Panel – LED Status.................................................................10
2.4. NuStreams-P6GW Front Panel – Buttons.......................................................................12
3. Hardware Installation of NuStreams-P6GW............................................................................13
3.1. Installation for Residential Gateway (Broadband Router) Test....................................13
3.2. Installation for Switch Test ..............................................................................................14
3.3. Installation for Residential Gateway (Broadband Router) + Switch Test....................15
3.4. Installation for WLAN (Wireless LAN) Testing ...............................................................16
4. Making Settings with Front Panel Buttons & LCD .................................................................17
4.1. NuStreams-P6GW Buttons Overview .............................................................................17
4.2. NuStreams-P6GW LCD Overview....................................................................................18
4.3. NuStreams-P6GW Front Panel Functions – Basic Controls.........................................19
4.4. NuStreams-P6GW Front Panel Functions – Test Setting..............................................21
4.5. NuStreams-P6GW Front Panel Functions – Test Log...................................................23
4.6. NuStreams-P6GW Front Panel Functions – System Setting........................................24
4.7. NuStreams-P6GW Front Panel Functions – System Information ................................25
5. NuSet-MiniPG.............................................................................................................................26
5.1. Installing/Uninstalling NuSet-MiniPG..............................................................................27
5.2. NuSet-MiniPG Overview...................................................................................................31
5.2.1. Starting NuSet-MiniPG................................................................................................31
5.2.2. NuSet-MiniPG Overview..............................................................................................32
5.3. NuSet-MiniPG-Config Functions.....................................................................................33
5.3.1. NuSet-MiniPG-Config Functions Overview...............................................................33
5.3.2. NuSet-MiniPG-Config Function – Menu Bar..............................................................34
5.3.2.1. Menu Bar – File.....................................................................................................34
5.3.2.2. Menu Bar – Task ...................................................................................................35
5.3.2.3. Menu Bar – Log.....................................................................................................35
5.3.2.4. Menu Bar – Service...............................................................................................36
5.3.2.5. Menu Bar – Languages ........................................................................................36
5.3.2.6. Menu Bar – Help....................................................................................................36
5.3.3. NuSet-MiniPG-Config Function – Quick Launch Buttons........................................37
5.3.3.1. Quick Launch Buttons – Reconnect...................................................................37
5.3.3.2. Quick Launch Buttons – Load & Save................................................................37
5.3.3.3. Quick Launch Buttons – Get Task/Apply All......................................................38
5.3.3.4. Quick Launch Buttons – Get Log/Clear Log/Log Folder...................................38
5.3.4. NuSet-MiniPG-Config Function – Info/Run Select List ............................................39
5.3.5. Configuring Tasks with NuSet-MiniPG-Config..........................................................41
5.3.5.1. NuSet-MiniPG-Config Task Setting – Router .....................................................42
5.3.5.2. NuSet-MiniPG-Config Task Setting – Switch .....................................................44
5.3.5.3. NuSet-MiniPG-Config Task Setting – Router + Switch......................................46
5.4. NuSet-MiniPG-ST Functions............................................................................................48
5.4.1. NuSet-MiniPG-ST Functions Overview......................................................................48
5.4.2. NuSet-MiniPG-ST Function – Menu Bar ....................................................................50
5.4.2.1. Menu Bar – File.....................................................................................................50
5.4.2.2. Menu Bar – Config................................................................................................50
5.4.2.3. Menu Bar – Report................................................................................................51
4
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 5
5.4.2.4. Menu Bar – Languages ........................................................................................52
5.4.2.5. Menu Bar – Help....................................................................................................52
5.4.3. NuSet-MiniPG-ST Function – Quick Launch Buttons ..............................................53
5.4.3.1. Quick Launch Buttons – Reconnect...................................................................53
5.4.3.2. Quick Launch Buttons – Port Select...................................................................53
5.4.3.3. Quick Launch Buttons – Port Config..................................................................54
5.4.3.4. Quick Launch Buttons – WLAN Config..............................................................55
5.4.3.5. Quick Launch Buttons – Counter........................................................................56
5.4.4. NuSet-MiniPG-ST Function – Info/Port Select List...................................................57
5.4.5. NuSet-MiniPG-ST Function – Control Buttons .........................................................58
5.4.6. Counter Report ............................................................................................................59
5.4.6.1. Control Buttons ....................................................................................................60
5.4.6.2. Main Display Screen.............................................................................................60
5.4.6.3. Port/Packet Setting Options................................................................................61
5.5. NuSet-MiniPG-UG Functions...........................................................................................64
5.5.1. NuSet-MiniPG-UG Functions Overview.....................................................................64
5.5.2. NuSet-MiniPG-UG Function – Menu Bar....................................................................65
5.5.2.1. Menu Bar – File.....................................................................................................65
5.5.2.2. Menu Bar – Upgrade.............................................................................................65
5.5.2.3. Menu Bar – Languages ........................................................................................72
5.5.2.4. Menu Bar – Help....................................................................................................72
5.5.3. NuSet-MiniPG-UG Function – Quick Launch Buttons..............................................73
5.5.3.1. Quick Launch Buttons – Reconnect...................................................................73
5.5.3.2. Quick Launch Buttons – Firmware Upgrade......................................................73
5.5.3.3. Quick Launch Buttons – FPGA Upgrade............................................................73
5.5.3.4. Quick Launch Buttons – NuPAD Firmware Upgrade.........................................73
5.5.3.4. Quick Launch Buttons – License Upgrade ........................................................74
5.5.4. NuSet-MiniPG-UG Function – Info Select List ..........................................................74
6. Controlling Tests with NuPA D..................................................................................................75
6.1. NuPAD Functions Overview ............................................................................................75
6.2. Connecting NuPAD with NuSTreams-P6GW..................................................................76
6.3. Starting DUT Tests with NuPAD ......................................................................................77
5
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 6
6
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
1. NuStreams-P6GW Overview
1.1. NuStreams-P6GW General Description
NuStreams-P6GW is a four-port stand-alone Switch /Residential Gateway (Broadband Router) test device for testing switches and
broadband routers (along with their switch ports) at wirespeed with its 4 Switch Ports, 1 WAN Port and Wireless Module. Also, NuStreams-P6GW can be connected to PC for accessing its simple and easy-to-use configuration utility.
Each of NuStreams-P6GW’s 3 RUNs contains 4 Tasks. These Tasks allow users to simultaneously perform tests in 10M Full/Half, 100M Full/Half and 1000M Full with a single button. This innovative design can greatly reduce the time consumed when performing product tests.
With 3 different Test Types (Router, Switch, and Router + Switch) available, NuStreams-P6GW can perform tests on switch/router, or combining each of these test subjects under “Router + Switch” Test Type, and test a broadband router’s WAN/LAN performance at the same time.
NuStreams-P6GW supports bi-direction LAN/WAN test packets with 253 IP addresses. Each IP has its own settings and transmitting/receiving counters, including independent statistics and calculations for latency and Serial Number. Also, both DUT and NuStreams-P6GW’s IP addresses can be any IP of 256 IP addresses from Class C.
Embedded with a Wireless Module that complies with IEEE802.11n Draft 2.0, NuStreams-P6GW can connect to DUT wirelessly and perform wireless throughput tests.
NuStreams-P6GW comes with its own utility software. NuSet-MiniPG allows users to set DUT test criteria, upgrading NuStreams-P6GW firmware/FPGA, and accessing detail test logs/statistics for further analysis.
With the ability to provide high reliable test results and the best cost/performance ratio, NuStreams-P6GW is the best solutions available for router and switch tests.
Page 7
1.2. Key Features of NuStreams-P6GW
Compact, lightweight, and portable 4-port test device for testing network switches and routers
Flexible WAN port connection for router tests:
¾ Static IP ¾ DHCP (Dynamic Host Configuration Protocol) ¾ PPPoE (Point-to-Point Protocol over Ethernet)
Embedded with IEEE802.11n Draft 2.0 wireless module, thus allowing performing wireless throughput
tests
Supporting bi-direction LAN/WAN test packets with 253 IP addresses. Each IP has its own settings and
transmitting/receiving counters, including independent statistics and calculations for latency, Serial Number, and VLAN Tags
Both DUT and NuStreams-P6GW’s IP addresses can be any IP of 256 IP addresses from Class C
Supports and can receive packet in PPP LCP, IPCP PAP formats
Tests are performed automatically in a step-by-step manner, which makes NuStreams-P6GW a more
productive solution than traditional PC-based solutions
NuStreams-P6GW’ s hardware information, such as FPGA/Firmware version and system temperature, is
available and can be checked on its LCD screen
LCD screen for displaying test results and related statistics
1.3. NuPAD Overview
Built to be light and easy-to-handle, NuStreams-P6GW is designed to meet the needs of production lines. However, considering the buttons on NuStreams-P6GW might be too small to operate, an optional keypad NuPAD is available to solve this inconvenience.
NuPAD is an optional keypad with intuitive platforms and easy-to-use buttons, and can be connected to NuStreams-P6GW in mass production line.
Although possessing no configuration functions, the lighter and smaller NuPAD provides 3 big, durable buttons (RUN 1~3) for users to operate the test procedure easily without touching configuration buttons on the top panel of NuStreams-P6GW.
NuPAD Key Features
Simple, easy to operate, performing tests fast
Easy for maintenance. If NuPAD malfunctions, there’s no need to fix/replace the NuStreams-P6GW
that’s connected to it
Intuitive Buttons for production crews to verify test results fast
7
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 8
8
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
2. NuStreams-P6GW Function Overview
2.1. NuStreams-P6GW Interface Ports
Description
A
38400 bps RJ45 Console Port for connecting NuStreams-P6GW and NuPAD
B
Standard Type B USB Receptacle Port
C
10/100/1000 Mbps Ethernet RJ45 WAN Port
D
8-Pin Mini-DIN Receptacle Diagnostic Port
E
DC 12 V Power Jack
F
IEEE802.11n Wireless Antenna Port for 2dBi Antenna
G
10/100/1000 Mbps Ethernet RJ45 Switch/WAN Port
H
10/100/1000 Mbps Ethernet RJ45 Switch/LAN Ports × 4
Page 9
9
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
2.2. NuStreams-P6GW Front Panel – LCD & LEDs
LCD & LEDs Descriptions
Test Start Time
Packets Received
Test End Time
Error Packets
Packets Transmitted
Test Fail/Pass
LCD A
LCD Display
Screen
Throughput (packets/second) base on pre-defined allowable tolerance
B System Status
Power SYS USB
C
WLAN
Connection
b(IEEEE802.11b) a(IEEEE802.11a) g(IEEEE802.11g) n(IEEEE802.11n)
D WAN Type
Static IP DHCP PPPoE
E Test Status
Pass: DUT Test Pass Fail: DUT Test Fail
F
Test Hotkey
Status
Pause: Current running test paused Run 1/2/3: Test Task of Run 1/2/3 is
running
G
Router
(LAN
WAN)
NuStreams-P6GW is set to test Broadband Router.
H
Switch (SW
2~5)
NuStreams-P6GW is set to test Switch. LED 2~5 indicates the number of ports used. Test starts from Step 1 to Step 4
I
Test Step
Status
1. Link Status Test
3. Test Starts
2. Auto Negotiation Connection Test
4. Test Finished
LEDs
J
LAN Ports
(1~5) Status
Reserve Link/ACT Error
Page 10
10
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
2.3. NuStreams-P6GW Front Panel – LED Status
The table down below contains NuStreams-P6GW’s front panel LED status and their meanings.
LED Status Description
Power
Green ON NuStreams-P6GW is on
Green OFF NuStreams-P6GW’s CPU system down
Green ON NuStreams-P6GW CPU system initializing
Green
Blinking
NuStreams-P6GW’s CPU system active and running
Yellow ON NuStreams-P6GW is not starting properly
SYS
Yellow Green
Blinking
NuStreams-P6GW is upgrading firmware
B
System
Status
USB
Green ON
NuStreams-P6GW is connecting to PC via USB cable
b
Green On The connection is set to b(IEEEE802.11b)
a
Green On
The connection is set to a(IEEEE802.11a)
g
Green On
The connection is set to g(IEEEE802.11g)
C
WLAN
Connection
n
Green On
The connection is set to n(IEEEE802.11n)
Static IP
Green ON DUT WAN connection is set to Static-IP
DHCP
Green ON DUT WAN connection is set to DHCP
D WAN Type
PPPoE
Green ON DUT WAN connection is set to PPPoE
Pass
Green ON DUT test passed
E Test Status
Fail
Red ON DUT test failed
Pause
Yellow ON The current running test is paused
Run 1
Green ON All Tasks stored in Run 1 are running
Run 2
Green ON All Tasks stored in Run 2 are running
F
Test
Hotkey
Status
Run 3
Green ON All Tasks stored in Run 3 are running
Page 11
LED Status Description
G
Router
(LAN
WAN)
Green ON NuStreams-P6GW is set to test Broadband Router
H
Switch
(SW2~5)
Green ON
NuStreams-P6GW is set to test Switch. LED 2~5 indicates the number of ports used
Step 1
Green ON Link Status Test
Step 2
Green ON Auto-Negotiation connection test
Step 3
Green ON Starting DUT tests
I
Test Step
Status
Step 4
Green ON Test complete, generating test results and report
Reserve
Green ON LAN Port is preserved for test Green ON LAN Port is connected to DUT
Link/ACT
Green
Blinking
NuStreams-P6GW is sending test packets via LAN Port
J
LAN Port
Status
(1~5)
Error
Yellow ON Error occurred during test
11
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 12
12
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
2.4. NuStreams-P6GW Front Panel – Buttons
Buttons Descriptions
Enter the Main Menu(*) or return to the previous Menu
Move the select cursor up
Move the select cursor down
K
Configuration
Buttons
Execute the selected selection
||
Pause
Pause the current running test
Run1
St art all Tasks set in Run 1. Up to 4 Tasks can be configured in Run 1 hotkey. Press this button to test ALL TASKS AT ONCE.
Run2
2
nd
hotkey that works as Run 1
L
Operation
Buttons
Run3
3
rd
hotkey that works as Run 1
*Menu will be displayed on the LCD screen.
Page 13
13
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
3. Hardware Installation of NuStreams-P6GW
NuStreams-P6GW can perform tests on Residential Gateway (Broadband Router), Switch, or Residential Gateway + Switch. Each test has its own different test options and parameters.
To perform tests on different DUTs mentioned above, you have to connect your NuStreams-P6GW differently. Please see the installation structure mentioned in this chapter for more detail information.
3.1. Installation for Residential Gateway (Broadband Router) Test
While performing tests on Residential Gateway (Broadband Router), both WAN and LAN ports of the DUT must be connected to NuS treams-P6GW with CAT-5 UTP cables as shown in the figure down below:
If NuStreams-P6GW’s WAN/LAN Ports and DUT’s ports are connected via CAT-5 UTP cables correctly, the Link/ACT LEDs located on NuStreams-P6GW’s LAN Port Status LED will be ON accordingly.
Page 14
14
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
3.2. Installation for Switch Test
While performing tests on Switch, DUT LAN ports must be connected to NuStreams-P6GW with CAT-5 UTP cables or/and the DUT must detects the NuStreams-P6GW’s signal from its Wireless Module as shown in the figure down below:
If both NuStreams-P6GW’s Switch Port 1~5 and DUT’s ports are connected via CAT-5 UTP cables correctly, the Link/ACT LEDs 1~5 located on NuStreams-P6GW’s LAN Port Status LED will be ON accordingly. If both Nustreams-P6GW and DUT are connected via Wireless connection, the last Link/ACT LED (WLAN) will be ON accordingly.
Page 15
15
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
3.3. Installation for Residential Gateway (Broadband Router) + Switch Test
While performing tests on Residential Gateway (Broadband Router) + Switch, both WAN and LAN ports of the DUT must be connected to NuStreams-P6GW with CAT-5 UTP cables as the installation structure when performing tests on Residential Gateway (Broadband Router) as shown in the figure down below:
Test options for Residential Gateway (Residential Router) + Switch and Residential Gateway
(Residential Router) are very similar, with minor differences listed in the table down below:
DUT Type Residential Gateway + Switch Residential Gateway
LAN Port Select
Flow Control
If NuStreams-P6GW’s WAN/LAN Ports and DUT’s ports are connected via CAT-5 UTP cables correctly, the Link/ACT LEDs located on NuStreams-P6GW’s LAN Port Status LED will be ON accordingly.
Page 16
16
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
3.4. Installation for WLAN (Wireless LAN) Testing
As mentioned previously, NuStreams-P6GW complies with IEEE802.11n Draft 2.0 and can connect to DUT wirelessly and perform wireless throughput tests. However, in order to perform wireless tests, you have to connect NuStreams-P5G’s Switch Port 5 to one of DUT’s LAN Port as shown in the figure down below:
For more detailed information regarding to connect NuStreams-P6GW and your DUT wirelessly, please refer to “5.3.5. Configuring Tasks with NuSet-MiniPG-Config” and “5.4.3.4. Quick Launch Buttons – WLAN Config”.
Page 17
17
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
4. Making Settings with Front Panel Buttons & LCD
All parameters for DUT tests can be configured via control buttons located on the front panel. Also, configuring, testing, and system information are displayed and can be viewed on the LCD screen as well.
Before performing any tests, NuStreams-P5G should be connected to DUT properly according to DUT’s type. Please refer to 3. Hardware Installation of NuStreams-P6GW for more detail information.
4.1. NuStreams-P6GW Buttons Overview
With NuStreams-P6GW’s control buttons located on its front panel, all test parameters and system configurations can be set via these buttons.
Buttons Descriptions
Enter the Main Menu(*) or return to the previous Menu
Move the select cursor up
Move the select cursor down
K
Configuration
Buttons
Execute the selected selection
||
Pause
Pause the current running test
Run1
St art all Tasks set in Run 1. Up to 4 Tasks can be configured in Run 1 hotkey. Press this button to test ALL TASKS AT ONCE.
Run2
2
nd
hotkey that works as Run 1
L
Operation
Buttons
Run3
3
rd
hotkey that works as Run 1
*Menu and setting options will be displayed on the LCD screen.
Page 18
18
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
4.2. NuStreams-P6GW LCD Overview
All configuration options and system information can be viewed via NuStreams-P6GW’s LCD screen. All options and their functions contained in the menu are listed down below:
Layer 1 Menu Layer 2 Menu Description
Modify Run
1~3
You can configure test parameters for Run 1~3 under this menu. Each Run can hold up to 4 Tasks
Test Setting
Load Default Restore all parameters stored in Run 1~3 to default value
View Log View test logs generated after the tests are complete
Clear Log Delete all logs stored in NuStreams-P6GW
Store Log Test reports will be stored automatically if this function is enable
T es t Log
Full Warning System will issue warnings when log storage memory is running out
Buzzer If enabled, system will buzz whenever a button is pressed
Password You can set new password for the system under this menu
Date/Time System date and time can be configured under this menu
System Setting
Load Default Restore all system settings to default value
System Information
N/A Display detailed system information
Test Settin
g
Modify Run 1
Modify Run 2
Modify Run 3
Load Default
Test Lo
g
V
iew Lo
g
ClearLo
g
Store Log On/Off
Full Warning On/Off
System Settin
g
Buzzer On/Of
f
Password
Date/Time
Load Default
System Information
Layer 1 Menu Layer 2 Menu
Page 19
19
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
4.3. NuStreams-P6GW Front Panel Functions – Basic Controls
The table down below shows NuStreams-P6GW’s basic controls.
Basic Setting Controls
Function Control Button Action LCD Display
Entering Main
Menu
Press
button to enter NuStreams-P6GW’s main
menu.
Back to
Previous
Menu
Press
button to go back to the previous menu.
Moving
Selection
Cursor
Press
to move the selection cursor up, or press
to move the selection cursor down.
Entering
Selected
Option
Press
button to enter the menu option you chose.
Page 20
20
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Basic Test Performing Controls
Function Control Button Action LCD Display
Start All T asks
Set in Run 1~3
Press Run1 button to start all Tasks set in Run 1, press Run2 button to start all Tasks set in Run 2, and press Run3 button to start all Tasks set in Run
3. All Tasks set in the Run will be performed at the same
time after pressing Run1, ► Run2, or Run3 button.
Pause
Press || Pause button to pause the current running test. Press || Pause button to resume.
Stop All
Running Tests
& Exit
Press
button to stop all running tests and exit.
Page 21
21
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
4.4. NuStreams-P6GW Front Panel Functions – Test Setting
Function Control Button Action LCD Display
Entering Test Setting Menu
Move the cursor to “Test Setting”, and press button. NuStreams-P6GW will prompt you to input the
system password. The default password is
. Press button after inputting the
password to enter the test setting menu.
Insert/Delete
Tasks
You can also insert or delete Tasks. To add a new task to the current Run, choose “insert”
from “Run List” menu, and press
button. A new
task with default parameters will be added to that Run.
To remove an existing task of the current Run, choose “delete” from “Run List” menu, and press
button. The existing task you chose will be deleted. Each “Run” can contain up to 4 Tasks, while each
Task is an independent test that can contain different test parameters.
Load Default
You can reset all settings stored in all 3 Runs and load the default test configurations here.
To load default test configurations, choose “Load Default” from “Run List” menu, and press
button.
NuStreams-P6GW will confirm if you really want to reset all test settings to default values. Press button to confirm, or press
button to cancel.
Page 22
22
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Function Control Button Action LCD Display
Modifying
Test
Parameters
Press
or buttons to choose which “Run” you
would like to modify. Press
button to start
configuring the selected “Run”. Choose “Modify” and press
to start configuring parameters for the Task
you’ve chosen. Press
or buttons to choose which
parameter you would like to configure, and press button to start configuring. Change parameter values
with
or buttons, and press button to
apply the changes.
Press
button again to save the settings you’ve
made to the Task and go back to Run List menu. NuStreams-P6GW supports 3 test modes: Router,
Switch, and Router + Switch. For detail test setting options, please refer to “5.3.5. Configuring Tasks with NuSet-MiniPG-Config”.
Page 23
23
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
4.5. NuStreams-P6GW Front Panel Functions – Test Log
Function Control Button Action LCD Display
Entering Test
Log Menu
Move the cursor to “Test Log”, and press button.
View Log
Choose “View Log” from “Test Log” menu list, and press
button.
Delete Log
Choose “Clear Log” from “Test Log” menu list, and press
button.
System will ask if you really want to delete all logs stored in NuStreams-P6GW. Press
to confirm,
or
to cancel.
Log Auto-Save
Choose “Store Log” from “Test Log” menu list, and press
button. The select cursor “” will be
changed to “” icon. Using
or buttons to
set Log Auto-Save function On or Off, and press button to apply the changes. System will save all test logs automatically if this function is ON.
Warning when
Memory Full
Choose “Full Warning” from “Test Log” menu list, and press button. The select cursor “” will be
changed to “” icon. Using
or buttons to
set Memory Full Warning function On or Off, and press
button to apply the changes. System will
alert you when its log storing memory is about to full if this function is ON.
Page 24
24
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
4.6. NuStreams-P6GW Front Panel Functions – System Setting
Function Control Button Action LCD Display
Entering
System Setting
Menu
Move the cursor to “System Setting”, and press
button. NuStreeams-P6GW will prompt you to
input the system password. The default password is
. Press button after inputting
the password to enter the test setting menu.
Buzzer
Choose “Buzzer” from “System Setting” menu list, and press
button. The select cursor “” will be
changed to “” icon. Pressing
or buttons
to set Buzzer function On or Off, and press button to apply the changes. System will make a
buzz sound whenever you press a button if this function is ON.
Password
On/Off
Choose “Password” from “System Setting” menu list, and press
button.
You can set the Password function On/Off by selecting Password: On/Off. Using /+ or /- buttons to set Password function On or Off.
Setting New
Password
Choose “Password” from “System Setting” menu list, and press
button.
You can change system password (Default
Password:
) under Setting
Password menu.
Password is a set of 4-button combination with
,
, Run1, Run2, and Run3 buttons.
Please input your old password under “ORG: “, and input your new password under “New: “.
System
Date/Time
Choose “Date/Time” from “System Setting” menu list, and press
button.
You can adjust system date and time by pressing
or buttons, and button to apply the
changes you’ve made.
Page 25
25
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Function Control Button Action LCD Display
Load System
Default Value
Choose “Load Default” from “System Setting” menu list, and press
button.
System will ask if you really want to set all system settings to default. Press
to confirm, or to
cancel.
4.7. NuStreams-P6GW Front Panel Functions – System Information
Function Control Button Action LCD Display
Entering
System
Information
Move the cursor to “System Information”, and press
button.
View System
Information
You can browser NuStreams-P6GW’s system information by pressing
or buttons.
Page 26
26
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5. NuSet-MiniPG
NuSet-MiniPG is a GUI (Graphic User Interface) configuration software that runs under
Microsoft Windows environment.
By connecting NuStreams-P6GW with PC to its USB Port with a USB cable, users can configure test parameters, download testing logs, and upgrade firmware/license. The figure down below is an example for connecting NuStreams-P6GW to PC via an USB cable.
All test parameters can be configured with NuSet-MiniPG, including all the configurations that can be set by buttons located on NuStreams-P6GW’s panels.
Please note that NuSet-MiniPG and NuStreams-P6GW’s hardware driver must be installed on PC first. After installing NuSet-MiniPG, NuStreams-P6GW’s driver will be installed automatically.
NuSet-MiniPG contains five different utilities with different functions as listed in the table down below:
Utility Description
NuSet-MiniPG-Config
Utility designed for setting test criteria and accessing test results/statistics.
NuSet-MiniPG-ST
Utility designed for testing network switch
NuSet-MiniPG-RT
Utility designed for testing residential gateway (router)
NuSet-MiniPG-RST
Utility designed for testing network switch and residential gateway (router)
NuSet-MiniPG-UG
Utility designed for upgrading NuStreams-P6GW and NuPAD’s firmware, FPGA and hardware license.
Also, please note that your PC, NuStreams-P6GW’s firmware and FPGA should meet the system requirements listed down below before installing NuSet-MiniPG.
OS Windows 2000/Windows XP Windows Vista/Windows 7
RAM
512MB RAM 1GB RAM
CPU
Pentium 1.3GHz or Higher
HDD
10 GB Available Space
Firmware
Version 0.9b012 or higher
FPGA
Version 0.1b009 or higher
Note: Large amount of data will be generated while running NuSet-MiniPG. It is recommended to preserve enough available Hard-Disk space to store these data.
This user’s manual will be focusing on NuSet-MiniPG-Config, NuSet-MiniPG-UG, and NuSet-MiniPG-ST only. The NuSet-MiniPG-RT and NuSet-MiniPG-RST are still not available.
Page 27
27
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.1. Installing/Uninstalling NuSet-MiniPG
Please follow the steps down below to install NuSet-MiniPG.
Installing NuSet-MiniPG
1. Double-click NuSet-MiniPG installation program and start the installation process*.
2. InstallShield Wizard is starting to install NuSet-MiniPG. If you would like to cancel installation, click “Cancel”.
3. Click “Next” to continue installation.
*Note: Due to different Operating Systems or system settings, warning messages might pop up when installing NuSet-MiniPG or driver for your device. When this occurs, please choose the options on these pop-up warning messages that allow you to continue installing NuSet-MiniPG or device driver.
Page 28
28
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Installing NuSet-MiniPG
4. Click “I accept the terms in the license agreement”, and click “Next” to continue.
5. Click the Change… button to install the program to another folder, or click
Next button to install the program into the default destination folder, and then continue next step. Click
Back button to
go back to the previous step to modify.
6. NuSet-MiniPG InstallShield Wizard will start installing momentarily. Click
Install
button to start installation.
Page 29
29
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Installing NuSet-MiniPG
7. InstallShield Wizard is installing NuSet-MiniPG.
8. NuSet-MiniPG installation completes. Click
Finish button to exit.
Page 30
30
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
To uninstall NuSet-MiniPG, you can:
Uninstalling NuSet-MiniPG
Click Start Æ Programs Æ Xtramus Æ
NuSet-MiniPG Æ Uninstall NuSet-MiniPG.
Go to the Control Panel, choose
NuSet-MiniPG from installed program
list, and click “Remove” to uninstall.
Please note that all of NuSet-MiniPG’s components will be uninstalled.
Page 31
31
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.2. NuSet-MiniPG Overview
5.2.1. Starting NuSet-MiniPG
Before starting NuSet-MiniPG, please be sure that your NuStreamsP6GW is properly connected to your PC. The figure down below is an example for connecting NuStreams-P6GW to PC via an USB cable.
You can start NuSet-MiniPG by:
Starting NuSet-MiniPG
¾ Double-click NuSet-MiniPG icon
located on your PC’s desktop
¾
Click Start Æ Programs Æ
Xtramus Æ NuSet-MiniPG Æ NuSet-MiniPG.
If your PC is not connected with NuStreams-P6GW, you can still run both NuSet-MiniPG-Config and NuSet-Mini-UG under Demo Mode. Almost all functions are available under Demo Mode. However, please note that Demo Mode is for system demo purposes only, and does not serve any testing purposes at all.
Page 32
32
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.2.2. NuSet-MiniPG Overview After starting NuSet-MiniPG as mentioned in “5.2.1. Starting NuSet-MiniPG”, a NuSet-MiniPG Option Menu will pop up as shown in the figure down below:
Utility Description
A NuSet-MiniPG-Config
Utility designed for setting test criteria and accessing test results/statistics.
B NuSet-MiniPG-ST
Utility designed for testing network switch
C
NuSet-MiniPG-RT Utility designed for testing residential gateway (router)
D
NuSet-MiniPG-RST
Utility designed for testing network switch and residential gateway (router)
E NuSet-MiniPG-UG
Utility designed for upgrading NuStreams-P6GW and NuPAD’s firmware, FPGA and hardware license.
Exit
Close NuSet-MiniPG.
*Only ONE utility can run at the same time, and NuSet-MiniPG can only work with ONE device.
You have to install different utilities in order to access different test modes listed on the NuSet-MiniPG Option Menu. Test modes without the proper utilities installed will be displayed as gray in color and
cannot be accessed from the NuSet-MiniPG Option Menu. When clicking an accessible option from NuSet-MiniPG
Option Menu, a Device Selection window will pop up, and prompt you to choose the device that will be used for testing. Please choose Nustreams-P6GW from the scroll-down menu, and click OK.
Note: Please note that this user’s manual will be focusing on NuSet-MiniPG-Config, NuSet-MiniPG-UG, and NuSet-MiniPG-ST only. The NuSet-MiniPG-RT and NuSet-MiniPG-RST are still not available.
Page 33
33
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.3. NuSet-MiniPG-Config Functions
5.3.1. NuSet-MiniPG-Config Functions Overview
If you choose Configuration for Hotkeys Operation from NuSet-MiniPG Option Menu, NuSet-MiniPG-Config’s main window
will pop up as shown below:
Function Descriptions
A Menu Bar
The Menu Bar allows you to access configuration files from your PC and NuStreams-P6GW, manage test logs, and perform system maintenance.
B
Quick Launch
Buttons
With a simple click of these Quick Launch Buttons, you can access configuration files from your PC/NuStreams-P6GW and managing test logs.
C Info/Run Select List
This section contains a selectable list of NuStreams-P6GW’s detailed system information and Test List.
D
Main Display
Window
This section displays detailed system information or all test p arameters you can configure for each Task in Run 1~3.
E
USB Connection
Status
This icon shows the connection status between your PC and NuStreams-P6GW.
Page 34
5.3.2. NuSet-MiniPG-Config Function – Menu Bar
The Menu Bar includes configuration options such as File, Task, Log, Service, Language, and Help.
5.3.2.1. Menu Bar – File File
Load Default Config. Profile
The system will load the default test settings for Run 1~3. All test parameters in Run 1~3 will be set to default value. However , loading test settings won’t be saved to NuStreams-P6GW until applied.
Load Config. Profile From
You can choose to load test settings either from Existing Files, or Pre-defined Files for Network Products.
Existing Files: NuSet-MiniPG-Config will load test settings which you saved
previously.
Pre-defined Files for Network Products: NuSet-MiniPG-Config will load
test setting samples for network products pre-defined by Xtramus. All these test settings are stored in “Default Config Profile” folder located under NuSet-MiniPG-Config’s installation folder. These test settings are named by the format of A_B_C_D_E_F, which means:
¾ A: Name of the testing device. In here ¾ B: Type of the DUT (Chip or Model) ¾ C: Name of the Manufacturer ¾ D: DUT Model Name ¾ E: DUT Version ¾ F: Testing WAN type.
Please note that loading test settings won’t be saved to NuStreams-P6GW until applied.
Save Configuration
You can save all parameter changes through Run 1~3 you made to your PC. If you haven’t saved the changes previously , a Select Run window will pop up and ask you which test setting (Run) you would like to save.
Save As…
The “Save As…” function is similar to the “Save Configuration”. The only difference is that you can save test settings (Run) with different file names.
Exit
Exit NuSet-MiniPG-Config.
34
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 35
35
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.3.2.2. Menu Bar – Task Task
Get Task
This function allows NuSet-MiniPG-Config to access all test settings (Run) from NuStreams-P6GW and show those settings in both Info/Run Select List and
Main Display Window.
Add Task
As mentioned in sections above, each Run can hold up to 4 different Tasks. Y ou can add new Tasks to each Run with this function. To add a new Task, click the Run you would like to add the new Task to from Info/Run Select List, then click
Task Add Task on the Menu Bar.
Delete Task
You can delete an existing Task with this function. To delete an existing task, click the Task you would like to delete from Info/Run Select List, and click Task
Delete Task on the Menu Bar.
Apply All
Apply and save all changes you’ve made to NuStreams-P6GW.
*Please note that the connection (of USB cable) between PC and NuStreams- P6GW must be connected at all time while getting/setting tasks.
5.3.2.3. Menu Bar – Log Log
Get Log
Accessing test logs from NuStreams-P6GW’s memory and save these logs to a specific folder on your PC. After retrieving test logs from NuStreams-P6GW, the log folder will pop up. Also, a message window contains detail information about system log file memory buffer will pop up. Click YES if you want to clear all stored logs or click NO to cancel.
Clear Log
Clear all test logs stored in NuStreams-P6GW’s memory.
Log Saving Settings
Log saving settings can be configured here:
Save Log to Device: If this
function is ON, all test logs will be saved in its log file memory buffer.
Warning when Log storage
space is full: System will issue a warning if the log file memory buffer is about to full.
Log Folder
Show the file folder where test logs are stored.
Set Log Folder
Change where you would like to save test logs retrieved from NuStreams-P6GW. You can create new folders for log-saving as well.
Page 36
36
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.3.2.4. Menu Bar – Service Service
If NuStreams- P6GW’s password has been changed, you could reset it to default (
) by “Clear Device Password” function.
A “Clear Device Password” window will pop up when you choose this function from Menu Bar. Input “admin” in the “Password” column and click “OK”. The password will be cleared and
set to the default
.
You can change NuSet-MiniPG’s password (default: admin) by click the Modify” button on “Clear Device
Password” window. A “Modify Password” window will pop up.
Input NuSet-MiniPG’s old password under “Old Password” column, and type in the new password under both “New Password” and “Confirm
Password” columns.
System Setting
If you forget NuSet-MiniPG’s password, please uninstall NuSet-MiniPG, and re-install it again. NuSet-MiniPG’s password will be set to “admin” after re-installation.
5.3.2.5. Menu Bar – Languages Languages
English Simplified Chinese
NuSet-MiniPG-Config has 2 different languages for its UI available. You can set the language of UI to either English or Simplified Chinese.
5.3.2.6. Menu Bar – Help
Help Xtramus Web
Access Xtramus Website (www.xtramus.com).
System Requirements
A “System Requirements” window will pop up and show the requirements for your PC and the FPGA/Firmware of NuStreams-P6GW.
¾ OK: Click this button to exit the
System Requirements” pop-up window.
About NuSet-MiniPG-Config
An “About” window will pop up and show detailed system information.
Page 37
37
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.3.3. NuSet-MiniPG-Config Function – Quick Launch Buttons
These Quick Launch Buttons allow you to reconnect NuStreams-P6GW, access test setting files from your PC or NuStreams-P6GW, or managing test log files.
5.3.3.1. Quick Launch Buttons – Reconnect Reconnect
If the USB connection between your PC and NuStreams-P6GW is down, a “Disconnected” icon
will be shown in “USB Connection
Status”.
Reconnect
Press Reconnect button
to re-establish the connection between your PC and NuStreams-P6GW. If the connection has been established successfully, a message window will pop up, and the “USB Connection Status” will be shown as “Connected
.
5.3.3.2. Quick Launch Buttons – Load & Save Load & Save
The Load and Save buttons allow you to load or save test settings from/to your PC, identical to “Load Config. Profile From Existing Files” and “Save
Configuration” functions available in the Menu Bar mentioned in 5.3.1.1. Menu Bar – File.
To load test setting files stored in your PC, click “Load” button, select which Run (or All 3 Runs) to apply the settings, and choose the path which the test setting file are located.
To save test setting on your PC, click “Save” button, select which Run (or All 3 Runs) to save, and choose where you would like to save the test settings.
Load & Save
Test setting files for each Run (Run 1~3) are named in the format of “.run”, while test setting files for all runs are named in the format of
.all”.
Page 38
38
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.3.3.3. Quick Launch Buttons – Get Task/Apply All Get Task/Apply All
By clicking Get Task button, you can load test settings from NuStreams-P6GW, display all settings in Info/Run Select List and Main Display Window.
On the other hand, Apply All button allows you to apply all the changes you’ve made to all Runs and save these settings to your NuStreams-P6GW.
To load test settings from NuStreams- P6GW, click “Get Task” button. Settings will be displayed in
Info/Run Select List and Main Display Window.
To apply all the changes you’ve made with the utility software and save these settings to NuStreams-P6GW, click “Apply All”.
Get Task/Apply All
Please note that the USB cable connection between PC and NuStreams­P6GW must be connected at all time while getting/setting tasks.
5.3.3.4. Quick Launch Buttons – Get Log/Clear Log/Log Folder Get Log/Clear Log/Log Folder
Get Log and Clear Log buttons allow you to obtain test logs from
NuStreams-P6GW or clear all test logs stored in NuStreams-P6GW, just like the “Get Device Log” and “Clear Device Log” on the Menu Bar.
To get all test logs from NuStreams­P6GW, click “Get Log” button. A window with NuStreams-P6GW log memory space and log folder screen will pop up. Click Yes to clear all test logs in NuStreams-P6GW, or click No to leave these test logs be.
Get Log/Clear Log
To clear all test logs stored in NuStreams –P6GW’s log memory, click “Clear Log” button, and click Yes.
Log Folder
Click “Log Folder” button to open the folder where all test logs are stored on your PC. All log folders are named with the test date, and all logs are named with the test date and time.
Page 39
39
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.3.4. NuSet-MiniPG-Config Function – Info/Run Select List
The Info/Run Select List contains a list of selectable options. When selected, the Main Display Window will show the corresponding information/Run setting.
System Information
To show NuStreams-P6GW’s detailed system information, click “System Information” on the Info/Run Select List. A detailed System Information will display on the Main Display Window
located in the right side of the Info/Run Select List.
The System Information displayed on Main Display Window shows NuStreams-P6GW and NuPAD’s detail information and status.
Refresh: Update the latest system information and status, press this button.
Page 40
40
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Test List
To access test settings stored in NuStreams-P6GW, please click button located on the Quick Launch Buttons section so NuSet-MiniPG-Config can access and display all Runs stored in NuStreams-P6GW.
Please note that the USB connection between PC and NuStreams- P6GW must be connected at all time while getting/setting tasks.
All test settings stored in NuStreams-P6GW will be displayed under Test List. All parameters in each Task can be viewed or changed by the detailed configuration window displayed on the Main Display Window.
By right clicking a Task on Test List, you can Add Task, Delete Task, Apply All, Copy, or Paste Tasks.
Add Task: Add a Task with default test setting
values to the current Run. Up to 4 Tasks can be added in one Run.
Delete Task: Delete the current Task.
Apply All: Apply all test settings and save these
settings to NuStreams-P6GW.
Copy: Copy current Task.
Paste: Paste the Task you copied to the current
Run.
Also, by clicking Run 1~3 listed on Test List, you can change the title of each Run on the Main Display Window.
Page 41
41
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.3.5. Configuring Tasks with NuSet-MiniPG-Config
After acquiring all the Tasks stored in NuStreams-P6GW, click the specific Task you would like to configure on the Info/Run Select List to configure/view all parameters of that Task in Main Display Window as shown in the figure down below:
Before configuring test parameters in each Task, please select the DUT Test Type first. The test parameters listed in the Main Display Window will change according to the DUT Te st Type you chose.
NuStreams-P6GW utility has 3 different test types:
Router: Testing Broadband Router including its WAN abilities.
Switch: Testing Switch and its switch functions.
Router + Switch: Testing Broadband Router as well as its
switch functions.
Page 42
42
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.3.5.1. NuSet-MiniPG-Config Task Setting – Router DUT – Router
T est Type/DUT Description
DUT: Choose “Router” from this scroll-down menu to start configuring router tests.
Get DUT Description: Enable this function to acquire DUT information during test and output it to test logs.
WLAN Setting
WLAN: You can enable/disable the WLAN function
here.
WLAN Rate(Mbps): You can modify WLAN transfer
rate by Mbps.
Attenuation (dB): You can modify the strength of
transmission wave here.
Password: This field must be filled with the password
for WAP setting of the DUT. *
Media Type
Media Type: You can set the connection speed here
with the scroll-down menu.
Link Down Time: The connection link between DUT
and NuStreams-P6GW will be forced to terminate when this function is enabled.
Link Wait (Minimum): NuStreams-P6GW will attempt
to establish connection with the DUT and wait for the minimum time (seconds). NuStreams-P6GW will keep waiting until the minimum time is met even the DUT has already responded.
Link Wait (Time Out): NuStreams-P6GW will attempt
to establish connection with the DUT and wait for a period of time until time out (second), and NuStreams-P6GW will not attempt to establish connection anymore.
Page 43
Connection Setting
et
input the static IP address you set in
the DUT here.
WAN Link Type: Choose the WAN connection type for DUT testing. Three WAN Link Types are available: DHCP, Static IP, and PPPoE. The WAN Link Type s here must be the same with the setting of the DUT.
DUT WAN Static IP: If the WAN Link Type is set as Static IP, please
ttempting to establish connection
put the gateway IP address you set
Connection Wait Timeout: This function sets the duration of time for a with DHCP server.
WAN Gateway IP: If the WAN Link Type is set as Static IP, please in in the DUT here.
Ts’
match DUT vender’s
CP Process if Valid: Disable or enable DHCP
server.
Check Vender ID: Enable this function to check DU MAC address and see if they designated MAC address.
Skip DH
If Check Vender ID is enabled, please input the vender’s designated MAC address here for
Vendor MAC:
comparisons.
VLAN Setting
LAN VLAN Tag: Add VLAN tags to all LAN packets. • LAN VLAN ID: VLAN ID for LAN.
WAN VLAN Tag: Add VLAN tags to all WAN packets WAN VLAN ID: VLAN ID for WAN.
Test Traffic
Packet Length: Length of testing packets.
ount of time
Delay Time After Learning: When enabled, NuStreams-P6GW will halt for the set am after performing network learning.
Test Time: The duration of time for DUT test. Delay Before Report: When ena bled,
NuStreams-P6GW will halt for the set amount of time before report.
Test Delay: When enabled, NuStreams-P6GW will h
for the set amount of time before starting DUT test.
alt
WAN to LAN Utilization (%): The traffic flow ratio from
WAN to LAN, presented in percentage (1~100).
Flow Control: W
transmitting rate w
hen Flow Control is enabled, the
ill drop if traffic overflow occurs.
o fromLAN to WAN Utilization (%): The traffic flow rati
LAN to WAN, presented in percentage (1~100).
Pass/Fail Criteria
Loss Tolerance (pkts): The acceptable number of lost
n data transmitting during tests (0~9999).
rance (pkts): The acceptable number of
exc packets in data transmitting during tests packets i
Excess Tole
ess
(0~9999).
Apply Run
Click this button to apply all the settings you’ve made and save the settings to NuStreams-P6GW.
* Note: It is recommended to perform WLAN tests in a shielding room.
Note: When WLAN is enabled, NuStreams-P6GW will attempt to connect with the first WAP
(Wireless Access Point) that appears in it*s SSID list. If that WAP is encrypted, NuStreams-P6GW will apply the password you input here.
43
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 44
44
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.3.5.2. NuSet-MiniPG-Config Task Setting – Switch DUT – Switch
T est Type/DUT Description
DUT: Choose “Switch” from this scroll-down menu to start configuring switch tests.
WLAN Setting*
WLAN: You can turn on or off the WLAN function here.
WLAN Rate(Mbps): You can modify WLAN transfer
rate by Mbps.
Attenuation(dB): You can modify the strength of
transmission wave here.
Password: This field must be filled with the password
for WAP setting of the DUT. *
Media Type
Testing Po rts: Please connect the DUT with
NuStreams-P6GW’s Switch Ports with Cat-5 cables according to the Testing LAN Ports you set here.
Media Type: You can set the connection speed here
with the scroll-down menu.
Link Wait (Minimum): NuStreams-P6GW will attempt
to establish connection with the DUT and wait for the minimum time (seconds). NuStreams-P6GW will keep waiting until the minimum time is met even the DUT has
onded. already resp
Link Wait (Time Out): NuStreams-P6GW will attempt
to establish connection with the DUT and wait for a period of time until time out (second), and NuStreams-P6GW will not attempt to establish connection anymore.
VLAN Setting
VLAN Tag: Add VLAN tags to all packets. • VLAN ID: VLAN ID.
Page 45
Test Traffic
Packet Length: The length of test packets (from
64~1518 Bytes) transmitting by NuStreams-P6GW.
Delay Time After Learning: When enabled,
NuStreams-P6GW will halt for the set amount of time after performing network learning.
Learning Time: NuStreams-P6GW will start sending
learning packets to the DUT. The DUT will record the MAC addresses of these packets, and learn the routing to NuStreams-P6GW.
Delay Before Report: When enabled,
NuStreams-P6GW will halt for the set amount of time before report.
Test Time: The duration of time for DUT test. Test Utilization (%): The traffic flow ratio of the entire
network, presented in percentage (1~100).
Flow Control: When Flow Control is enabled, the transmitting rate will drop if traffic overflow occurs.
Pass/Fail Criteria
Loss Tolerance (pkts): The acceptable number of lost
packets in data transmitting during tests (0~9999).
Excess Tolerance (pkts): The acceptable number of
excess packets in data transmitting during tests (0~9999).
Apply Run
Click this button to apply all the settings you’ve made and save the settings to NuStreams-P6GW.
* Note: It is recommended to perform WLAN tests in a shielding room. * Note: When WLAN is enabled, NuStreams-P6GW will attempt to connect with the first WAP
(Wireless Access Point) that appears in its SSID list. If that WAP is encrypted, NuStreams-P6GW will apply the password you input here.
45
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 46
46
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.3.5.3. NuSet-MiniPG-Config Task Setting – Router + Switch DUT: Router + Switch
T est Type/DUT Description
DUT: Choose “Router + Switch” from this scroll-down menu to start configuring tests for both routers and switches.
Get DUT Description: Enable this function to acquire DUT information during test and output it to test logs.
WLAN Setting*
WLAN: You can turn on or off the WLAN function here.
WLAN Rate(Mbps): You can modify WLAN transfer
rate by Mbps.
Attenuation(dB): You can modify the strength of
transmission wave here.
Password: This field must be filled with the password
for WAP setting of the DUT. *
Page 47
Media Type
Media Type: You can set the connection speed here
with the scroll-down menu.
Link Down Time: The connection link between DUT
and NuStreams-P6GW will be forced to terminate when this function is enabled.
Link Wait (Minimum): NuStreams-P6GW will attempt
to establish connection with the DUT and wait for the minimum time (seconds). NuStreams-P6GW will keep waiting until the minimum time is met even the DUT has already responded.
Link Wait (Time Out): NuStreams-P6GW will attempt
to establish connection with the DUT and wait for a period of time until time out (second), and NuStreams-P6GW will not attempt to establish connection anymore.
Testing LAN Ports: Please connect the DUT with NuStreams-P6GW’s Switch Ports with Cat-5 cables according
to the Testing LAN Port s you set here.
Connection Setting
WAN Link Type: Choose the WAN connection type for
DUT testing. Three WAN Link Types are available: DHCP, Static IP, and PPPoE. The WAN Link Type set here must be the same with the setting of the DUT.
DUT WAN Static IP: If the WAN Link Type is set as
Static IP, please input the static IP address you set in the DUT here.
Connection Wait Timeout: This function sets the
duration of time for attempting to establish connection with DHCP server.
WAN Gateway IP: If the WAN Link Type is set as
Static IP, please input the gateway IP address you set in the DUT here.
Check Vender ID: Enable this function to check DUTs’
MAC address and see if they match DUT vender’s designated MAC address.
Skip DHCP Process if Valid: Disable or enable DHCP
server.
Vendor MAC: If Check Vender ID is enabled, please input the vender’s designated MAC address here for
comparisons.
VLAN Setting
LAN VLAN Tag: Add VLAN tags to all LAN packets. • LAN VLAN ID: VLAN ID for LAN.
WAN VLAN Tag: Add VLAN tags to all WAN packets WAN VLAN ID: VLAN ID for WAN.
Test Traffic
Packet Length: Length of testing packets. Delay Time After Learning: When enabled,
NuStreams-P6GW will halt for the set amount of time after performing network learning.
Test Time: The duration of time for DUT test. Delay Before Report: When ena bled,
NuStreams-P6GW will halt for the set amount of time before report.
Learning Time: The time for the Nustreams-P6GW to
learn the information received from DUT.
Switch Utilization (%): The traffic flow for Switch
transmission rate, presented in percentage (1~100).
Test Delay: When enabled, NuStreams-P6GW will halt
for the set amount of time before starting DUT test.
WAN to LAN Utilization (%): The traffic flow ratio from
WAN to LAN, presented in percentage (1~100).
ill drop if traffic overflow occurs.
o from
LAN to WAN, presented in percentage (1~100).
Flow Control: When Flow Control is enabled, the transmitting rate w
LAN to WAN Utilization (%): The traffic flow rati
Pass/Fail Criteria
st
packets in data transmitting during tests (0~9999).
r of
kets in data transmitting during tests
(0~9999).
Loss Tolerance (pkts): The acceptable number of lo Excess Tolerance (pkts): The acceptable numbe
excess pac
Apply Run
Click this button to apply all the settings you’ve made and save the settings to NuStreams-P6GW.
* Note: It is recommended to perform WLAN tests in a shielding room.
Note: When WLAN is enabled, NuStreams-P6GW will attempt to connect with the first WAP
(Wireless Access Point) that appears in i*ts SSID list. If that WAP is encrypted, NuStreams-P6GW will apply the password you input here.
47
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 48
48
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.4. NuSet-MiniPG-ST Functions
5.4.1. NuSet-MiniPG-ST Functions Overview
If you choose Network Switch Test from NuSet-MiniPG Option Menu, NuSet-MiniPG-ST’s main window will pop up as shown below:
A Port Select window will pop up as shown in the figure on the right hand. To access NuSet-MiniPG-ST and performing network switch tests, you have to select which switch port you would like to apply for performing tests first.
Click the check-box for the switch ports you would like to apply for the test (Switch Port 1~6, where Switch Port 6 also serves as WLAN Port), and click the Apply button to apply all settings you’ve made.
Page 49
49
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Function Descriptions
A Menu Bar
The Menu Bar allows you to select test ports, access configuration files from your PC and view counter reports.
B
Quick Launch
Buttons
With a simple click of these Quick Launch Buttons, you can select test ports, access configuration files from your PC and view counter reports.
C Info/Port Select List
This section contains a selectable list of NuStreams-P6GW’s detailed system information and port list.
D
Control Buttons &
Test Running Status
Icon
The Control Buttons allow you to start/stop tests, and the Test Running Status Icon indicates if the test is running.
E
Main Display
Window
This section displays detailed system information including all ports you’ve selected.
F
USB Connection
Status
This icon shows the connection status between your PC and NuStreams-P6GW.
Page 50
50
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.4.2. NuSet-MiniPG-ST Function – Menu Bar
The Menu Bar includes configuration options such as File, Config, Report, Language, and Help.
5.4.2.1. Menu Bar – File File
Load Default Configuration
The system will load the default test settings for switch tests.
Load Existing Configuration
NuSet-MiniPG-ST will load test settings which you saved previously.
Save Configuration
You can save all settings you’ve made for all ports to your PC.
Configuration Save As
The “Configuration Save As” function is similar to the “Save Configuration”. The only difference is that you can save settings with different file names.
Exit
Exit NuSet-MiniPG-ST.
5.4.2.2. Menu Bar – Config
Config
Port Select
As mentioned in 5.4.1. NuSet-MiniPG-ST Functions Overview, if you choose Port Select from the Menu Bar, a Port Select window will pop up
as shown in the figure on the right hand. To access NuSet-MiniPG-ST and performing network switch tests, you have to select which switch port you would like to apply for performing tests first.
Click the check-box for the switch ports you would like to apply for the test (Port 1~6, where Switch Port 6 serves as WLAN Port), and click the Apply button to apply all settings you’ve made.
¾ Apply: Apply all the settings you’ve made and exit. ¾ Cancel: Cancel all the settings you’ve made and exit.
Page 51
51
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Config
When you choose Port Configuration from the Menu Bar, a Port Configuration window will pop up, allowing you to set configuration parameters for all the ports you’ve selected.
You can set the Media Type or enabling Flow Control function here on the Port
Configuration pop-up window. Media Type
You can set the connection rate for all selected ports with the Media Type menu tab.
¾ Auto All: Set all ports to auto
-negotiation.
¾ Force 10M Full: All ports will be
set to 10M full-duplex.
¾ Force 100M Full: All ports will be
set to 100M full-duplex.
¾ Apply: Save all the settings you’ve
made without exiting.
¾ OK: Save all the settings you’ve
made and exit.
Flow Control
Port Configuration
You can enable/disable Flow Control here with the Flow Control menu tab.
¾ ON: Enable Flow Control. ¾ OFF: Disable Flow Control. ¾ Apply: Save all the settings you’ve
made without exiting.
¾ OK: Save all the settings you’ve
made and exit.
5.4.2.3. Menu Bar – Report
Report
Counter Report
When you choose Counter Report from the Menu Bar, the Counter Report will be displayed on NuSet-MiniPG-ST’s Main Display Window as shown in the figure on
the right. For more detailed information regarding to
Counter Report, please refer to 5.4.6. Counter Report.
Page 52
52
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.4.2.4. Menu Bar – Languages Languages
English Simplified Chinese
NuSet-MiniPG-ST has 2 different languages for its UI available. You can set the language of UI to either English or Simplified Chinese.
5.4.2.5. Menu Bar – Help
Help Xtramus Web
Access Xtramus Website (www.xtramus.com).
System Requirements
A “System Requirements” window will pop up and show the requirements for your PC and the FPGA/Firmware of NuStreams-P6GW.
¾ OK: Click this button to exit the
System Requirements” pop-up window.
About NuSet-MiniPG-ST
An “About” window will pop up and show detailed system information.
Page 53
53
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.4.3. NuSet-MiniPG-ST Function – Quick Launch Buttons
These Quick Launch Buttons allow you to reconnect NuStreams-P6GW, select test ports, access configuration files from your PC and view counter reports.
5.4.3.1. Quick Launch Buttons – Reconnect Reconnect
If the connection between your PC and NuStreams-P6GW is down, a “Disconnected” icon
will be shown in “USB Connection Status”.
Reconnect
Press Reconnect button
to re-establish the connection between your PC and NuStreams-P6GW. If the connection has been established successfully, a message window will pop up, and the “USB Connection Status” will be shown as “Connected
.
5.4.3.2. Quick Launch Buttons – Port Select Port Select
Port Select
As mentioned in 5.4.1. NuSet-MiniPG-ST Functions Overview, if you choose Port Select from the Menu Bar, a Port Select window will pop up as
shown in the figure on the right hand. To access NuSet-MiniPG-ST and performing network switch tests, you have to select which switch port you would like to apply for performing tests first.
Click the check-box for the switch ports you would like to apply for the test (Port 1~6, where Switch Port 6 serves as WLAN Port), and click the Apply button to apply all settings you’ve made.
¾ Apply: Apply all the settings you’ve made and exit. ¾ Cancel: Cancel all the settings you’ve made and exit.
Page 54
54
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.4.3.3. Quick Launch Buttons – Port Config
Port Config
When you press the Port Configuration button, a Port Configuration window will pop up, allowing you to set configuration parameters for all the ports you’ve selected.
You can set the Media Type or enabling Flow Control function here on the Port
Configuration pop-up window.
Media Type
You can set the connection rate for all selected ports with the Media Type menu tab.
¾ Auto All: Set all ports to auto
-negotiation.
¾ Force 10M Full:
A
ll ports will be set
to 10M full-duplex.
¾ Force 100M Full: All ports will be
set to 100M full-duplex.
¾ Apply: Save all the settings you’ve
made without exiting.
¾ OK: Save all the settings you’ve
made and exit.
Flow Control
Port Config
You can enable/disable Flow Control here with the Flow Control menu tab.
¾ ON: Enable Flow Control. ¾ OFF: Disable Flow Control. ¾ Apply: Save all the settings you’ve
made without exiting.
¾ OK: Save all the settings you’ve
made and exit.
Page 55
55
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.4.3.4. Quick Launch Buttons – WLAN Config
WLAN Config
When you press the WLAN Configuration button, a WLAN Config window will pop up, allowing you to set configuration parameter for WLAN port.
You can choose the WAP (Wireless Access Point) you would like to connect to by clicking the Setting button or modify the Attenuation (dB) and WLAN Rate (Mbps) values here.
WLAN Config
You can set the Attenuation (dB) and WLAN Rate (Mbps) value in this window.
¾ Setting: Choose the ESSID. ¾ Attenuation (dB): Set the
gradual loss of the radio wave during transmission.
¾ WLAN Rate (Mbps): Set the flow
rate for the radio wave transmission.
¾ Apply: Save all the setting
you’ve made without exiting.
¾ OK: Save all the setting you’ve
made and exit.
Settings
WLAN
Config
When you press the Setting button on the WLAN Config window, a WLAN Setting
window will pop up, allowing you to view all available WAPs (Wireless Access Point) and connect to the specific WAP for WLAN tests.
¾
Refresh: Press this button to
refresh the WLAN station list.
¾ No.: The number of the ESSID. ¾ ESSID: ESSID stands for Extended
Service Set Identifier, an ID for identifying different WAP. Also, you can view detail information (MAC Address, Protocol, ESSID, Quality, and Encryption) about that WAP if you move your mouse to the specific ESSID.
¾ Quality: WAP’s signal quality. ¾ Operate: You can connect/disconnect
to WAP by clicking the buttons here. If the WAP you chose is encrypted, a WLAN Password window will pop up, allowing you to input the password for that WAP.
¾ OK: Save all the setting you’ve made
and exit.
Page 56
56
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.4.3.5. Quick Launch Buttons – Counter Counter
Counter
When you press the Counter Report button, the Counter Report will be displayed on
NuSet-MiniPG-ST’s Main Display Window as shown in the figure on the right.
For more detailed information regarding to Counter Report, please refer to 5.4.6. Counter Report.
Page 57
57
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.4.4. NuSet-MiniPG-ST Function – Info/Port Select List
The Info/Port Select List allows you to view system information, as well as all information regarding to the ports you’ve selected.
System Information
To show NuStreams-P6GW’s detailed system information, click “System Information” on the Info/Run Select List. A detailed System Information will display on the Main Display Window
located in the right side of the Info/Run Select List.
The System Information displayed on Main Display Window shows NuStreams-P6GW and NuPAD’s detail information and status.
¾ Refresh: Update the latest system information and status, press this button.
Page 58
5.4.5. NuSet-MiniPG-ST Function – Control Buttons
The Control Buttons allow you to start/stop tests, and the Test Running Status Icon indicates if there’s a test running.
Control Buttons
Start test
Stop test
Test Running Status Icon
No test is underway
Test is running
58
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 59
59
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.4.6. Counter Report
You can view test counter reports or set switch port parameters here. There are two ways to access
Counter Report:
Accessing Chart
Click Counter Report located on Report in the Menu Bar.
Click the Counter button located on Quick Launch Buttons.
Counter Report
A Control Buttons
These two buttons allow you to save the counter report or all the settings you’ve made here on Counter Report.
B Main Display Screen
This field displays the counter report of all ports.
C
Port/Packet Setting
Options
You can make configurations for all the ports you’ve selected here in this field, as well as packet contents.
D Elapsed Time
This field displays the elapsed time of performing test.
E Apply/Cancel
You can press Apply to apply all the changes you’ve made here, or press Cancel to cancel all the changes you’ve made.
Page 60
60
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.4.6.1. Control Buttons
Control Buttons
The Save Report button allows you to save the current counter reports to Microsoft Excel ® format files.
The Save Report button allows you to save the current settings to your PC.
The Clear button allows you to clear all statistics displayed in the Main Display Screen. The Hide button allows you to hide some of the TX/Rx statistics, as well as fold all tree style
tab statistics in the Main Display Screen. The Show button allows you to show all TX/Rx statistics, as well as unfold all tree style tab
statistics in the Main Display Screen.
5.4.6.2. Main Display Screen
Main Display Screen
The Main Display Screen displays counter report statistics of all ports you’ve selected for test.
Page 61
61
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.4.6.3. Port/Packet Setting Options
You can make configurations for all the ports you’ve selected here in this field, as well as packet contents here.
Test Mode
The Test Mode allows you to set how packets will be transmitted through ports you’ve selected. There are two modes available here:
¾ Rotate: In Rotate test mode, packets will be sent from port to port in
a loop while the last port will be connected to the first port.
¾ Pair: In Pair test mode, two ports will be paired and packets will be
sent from the source port to the destination port. Please note that if you would like to set the test mode as Pair, the number of the ports you’ve selected must be an even number.
When the test mode is set as Pair, NuSet-MiniPG-ST will pair ports automatically. If you would like to pair the selected ports manually, please press the Setting button as shown in the figure on the right hand. A Pair Setting window will pop up. Please follow the steps down below to pair ports manually.
1. Please press the << button on the Pair Setting pop-up window to remove port pair setting made by NuSet-Mini-PG-ST automatically.
2. Please select a port that will be assigned as the source port from the Source Ports field.
Page 62
62
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Test Mode
3. Please select a port that will be assigned as the destination port from the Destination Ports field.
4. Press the > button to add the pair you’ve made to the Pair Ports field. If you would like to remove a port pair setting, please press the < button instead. If you would like to remove all port pair settings, please press the << button.
(Continued)
5. Please repeat step 2~4 until all ports are paired, then press the OK button to save all the settings you’ve made.
Learning Setting
You can enable or disable network learning function here in this field.
VLAN Setting
You can enable or disable VLAN functions for all the ports you’ve selected. When VLAN function is enabled, you can press the Setting button to set the VID manually.
A VLAN Setting window will pop up, allowing you to input VID (VLAN ID) manually for each port. After inputting VID for all the ports, please press the OK button to save all the changes you’ve made and exit VLAN Setting pop-up window.
Page 63
Packet Setting
You can set packet properties here in this field.
¾ Length: You can set the packet length here with the length
scroll-down menu. The packet length available here include 128, 256, 512, 1024, 1518, and Random.
¾ Payload: This scroll-down menu allows you to set packet
contents to Random, 16’0 16’1, 32’0 32’1, 55AA, 5555AAAA, All 1 or All 0.
¾ Utilization: You can set the utilization rate (in percentage) here
in this field.
Transmitting Setting
You can set the duration for packet transmission here in the Transmitting Setting field.
¾ By Time: NuSet-MiniPG-ST will send packets for the set
amount of time.
¾ By Packet: NuSet-MiniPG-ST will send the set amount of
packets.
63
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Page 64
64
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.5. NuSet-MiniPG-UG Functions
5.5.1. NuSet-MiniPG-UG Functions Overview
If you choose System Upgrade from NuSet-MiniPG Option Menu, NuSet-MiniPG-UG’s main window will pop up as shown below:
Function Descriptions A Menu Bar
The Menu Bar allows you to update NuStreams-P6GW/NuPAD’s firmware, FPGA and NuSet-MiniPG license.
B
Quick Launch
Buttons
With a simple click of these Quick Launch Buttons, you can reconnect to disconnected NuStreams-P6GW and updating firmware, FPGA and license.
C Info Select List
This section displays NuStreams-P6GW’s information.
D
Main Display
Window
This section displays detailed system information.
E
USB Connection
Status
This icon shows the connection status between your PC and NuStreams-P6GW.
Page 65
65
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.5.2. NuSet-MiniPG-UG Function – Menu Bar
The Menu Bar includes configuration options such as File, Upgrade, Language, and Help.
5.5.2.1. Menu Bar – File File
Exit
Exit NuSet-MiniPG-UG.
5.5.2.2. Menu Bar – Upgrade Upgrade
Firmware/FPGA Upgrade
Before upgrading NuStreams-P6GW’s firmware/FPGA, please be sure that NuStreams–P6GW and your PC are connected via USB cable all the time.
The following demonstrations will show you how to upgrade NuStreams-P6GW’s firmware. Processes for upgrading NuStreams-P6GW’s FPGA are quite the same and can be related.
1. To start upgrading NuStreams-P6GW’s firmware, click Upgrade Firmware Upgrade on NuSet-MiniPG-UG’s Menu Bar as shown in the figure
down below.
2. A message window will pop up, reminding you that all NuStreams-P6GW’s settings will be reset to default after firmware upgrading. Please click Yes to continue. Please note that all test logs stored in NuStreams-P6GW will be erased as well.
3. Select where NuStreams-P6GW’s firmware file (in the format of “*.bin”) is stored in your PC, then click “Open”.
Page 66
66
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Upgrade
Firmware/FPGA Upgrade (Contd.)
4. Click Yes to start upgrading firmware.
5. NuStreams-P6GW utility will start uploading firmware from your PC to NuStreams-P6GW.
It might take several minutes uploading firmware. Please note that the connection between NuStreams-P6GW and your PC shall remain connected at all time, and please be sure that the NuStreams-P6GW and your PC’s power remain ON during the process.
6. NuStreams-P6GW’s LCD will display messages as shown in the figure down below during firmware upgrading.
7. Firmware upgrading complete! Click OK to finish.
8. NuStreams-P6GW will reboot and its LCD will display messages as shown in the figure down below while rebooting.
9. The connection between NuStreams-P6GW and your PC will be severed after firmware upgrading. Please click the Reconnect button
on NuStreams-P6GW’s Quick Launch Button in order to re-establish the connection between your PC and NuStreams-P6GW.
Page 67
67
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Upgrade
Before upgrading NuPAD’s firmware, please connect NuPAD, NuStreams-P6GW, and your PC properly as shown below. The following sections will demonstrate how to upgrade NuPAD’s firmware with NuStreams-P6GW.
Installation for Upgrading NuPA D
1. Connect NuPAD with NuStreams-P6GW’s Console Port via a CAT-5
Straight- through cable as shown in the figure down below.
2. Connect NuStreams-P6GW’s USB Port with your PC via a USB cable as
shown in the figure down below.
NuPAD Firmware Upgrade
After connecting NuPAD, NuStreams-P6GW, and your PC according the descriptions shown above, please start upgrading NuPAD’s firmware according to steps shown on the following page.
Page 68
68
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Upgrade
NuPAD Firmware Upgrade (Contd.)
1. To start upgrading NuStreams-P6GW’s firmware, click Upgrade NuPAD Firmware Upgrade on NuSet-MiniPG-UG’s Menu Bar as shown in the figure
down below.
2. Select NuPAD’s firmware (in the format of “*.bin”) stored in your PC, then click “Open”.
3. Click Yes to start upgrading firmware.
4. NuSet-MiniPG-UG will start the NuPAD firmware upgrading process. Please note that during the upgrading process, NuPAD, NuStreams-P6GW, and your PC must be power on and connected properly at all time.
Page 69
69
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Upgrade
NuPAD Firmware Upgrade (Contd.)
5. During the firmware uploading process, NuPAD’s LCD screen will show the firmware upgrading process as shown in the figures down below.
6. During the firmware uploading process, NuPAD’s LCD screen will display messages as figure shown down below.
7. Firmware upgrading completes. Please click OK to continue.
8. When the firmware completes uploading, NuPAD’s LCD will display messages as figure shown down below.
9. NuPAD will reboot and try to re-connect with NuStreams-P6GW after upgrading its firmware. Please remove the USB cable between your PC and NuStreams-P6GW when NuPAD is connecting to NuStreams-P6GW.
Page 70
70
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Upgrade
License Upgrade
Before upgrading NuStreams-P6GW’s license, please be sure that NuStreams–P6GW and your PC are connected via USB cable all the time.
The following sections will demonstrate how to upgrade NuStreams-P6GW’s license.
1. To start upgrading NuStreams-P6GW’s license, click Upgrade License Upgrade on NuSet-MiniPG-UG’s Menu Bar as shown in the figure down below.
2. A License Update window will pop up, showing licenses for NuSet-MiniPG and NuStreams-P6GW. Please click the Load button located on the upper-left part to start updating license.
3. Select the license file (in the format of “*.PMW”) stored in your PC, then click “Open”.
Page 71
71
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Upgrade
License Upgrade (Contd.)
4. A message window will pop up and remind you that the PMW file has been loaded. Please click OK to continue.
5. Please note that the PMW file you’ve chosen hasn’t been upgraded yet. Click
the Upgrade button located on License Update window’s bottom-right part to finish upgrading your license.
If you have any problems with your NuStreams-P6GW/NuSet-MiniPG’ s license s, please contact Xtramus Technologies with the following contact information:
E-mail: sales@xtramus.com Tel: +886-2-8227-6611 Fax: +886-2-8227-6622
Page 72
72
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.5.2.3. Menu Bar – Languages
Languages English
Simplified Chinese
NuSet-MiniPG-Config has 2 different languages for its UI available. You can set the language of UI to either English or Simplified Chinese.
5.5.2.4. Menu Bar – Help Help
Xtramus Web
Access Xtramus Website (www.xtramus.com).
System Requirements
A “System Requirements” window will pop up and show the requirements for your PC and the FPGA/Firmware of NuStreams-P6GW.
¾ OK: Click this button to exit the
System Requirements” pop-up window.
About NuSet-MiniPG-UG
An “About” window will pop up and show detailed system information.
Page 73
73
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.5.3. NuSet-MiniPG-UG Function – Quick Launch Buttons
These Quick Launch Buttons allow you to reconnect NuStreams-P6GW, upgrading NuStreams-P6GW’s firmware/FPGA, upgrading NuPAD’s firmware, and upgrading NuSet-MiniPG/NuStreams-P6GW’s license.
5.5.3.1. Quick Launch Buttons – Reconnect
Reconnect
If the USB connection between your PC and NuStreams-P6GW is down, a “Disconnected” icon
will be shown in “USB Connection
Status”.
Reconnect
Press Reconnect button
to re-establish the connection between your PC and NuStreams-P6GW. If the connection has been established successfully, a message window will pop up, and the “USB Connection Status” will be shown as “Connected
.
5.5.3.2. Quick Launch Buttons – Firmware Upgrade Firmware Upgrade
Firmware Upgrade
The Firmware Upgrade button allows you to upgrade NuStreams-P6GW’s firmware. For more detailed descriptions, please refer to the “Firmware/FPGA Upgrade” section in “5.5.2.2. Menu Bar – Upgrade”.
5.5.3.3. Quick Launch Buttons – FPGA Upgrade FPGA Upgrade
FPGA Upgrade
The FPGA Upgrade button allows you to upgrade NuStreams-P6GW’s FPGA. For more detailed descriptions, please refer to the “Firmware/FPGA
Upgrade” section in “5.5.2.2. Menu Bar – Upgrade”.
5.5.3.4. Quick Launch Buttons – NuPAD Firmware Upgrade NuPAD Firmware Upgrade
NuPAD Firmware
Upgrade
The NuPAD Firmware Upgrade button allows you to upgrade NuPAD’s firmware. For more detailed descriptions, please refer to the “NuPAD Firmware Upgrade” section in “5.5.2.2. Menu Bar – Upgrade”.
Page 74
74
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
5.5.3.4. Quick Launch Buttons – License Upgrade License Upgrade
License Upgrade
The License Upgrade button allows you to upgrade NuSet-MiniPG or NuStreams-P6GW’s license. For more detailed descriptions, please refer to the “License Upgrade” section in “5.5.2.2. Menu Bar – Upgrade”.
5.5.4. NuSet-MiniPG-UG Function – Info Select List
The Info Select List contains a list of selectable o ptions. When selected, the Main Display W indow will show NuStreams-P6GW’s system information.
To show NuStreams-P6GW’s detailed system information, click “System Information” on the Info
Select List. A detailed System Information will display on the Main Display Window located in the right side of the Info Select List as shown in the figure down below.
The System Information displayed on Main Display Window shows NuStreams-P6GW and NuPAD’s detailed information and status.
Refresh: Update the latest system information and status, press this button.
Page 75
75
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
6. Controlling Tests with NuPAD
NuPAD is an assistant extension keypad, especially designed for running
tests at mass production line.
With all test parameters set and stored in NuStreams-P6GW, NuPAD allows users to perform tests without changing pre-set parameters.
6.1. NuPAD Functions Overview
Description
A Connection Port
Connecting NuPAD with NuStreams-P6GW’s Console Port.
B LCD Screen
Displaying system information, status, and test results.
C Control Buttons
¾ || Pause: Press this button to pause the current running test.
Press this button again to resume the test.
¾ Stop: Press this button to stop the current running test. ¾ Run: Press this button to start test.
D/E System LEDs
¾ Sys/Link/Alarm: Showing NuPAD running status. ¾ Power: When NuPAD is connected to NuStreams-P6GW’s
Console Port, the Green Power LED will be ON.
¾ Pass/Fail: If the test passed, the Pass/Fail Green LED will be
ON; if the test failed, the Pass/Fail Amber LED will be ON.
¾ Step 1~4: Showing the progress of the test.
Page 76
76
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
6.2. Connecting NuPAD with NuSTreams-P6GW
Before using NuPAD as NuStreams-P6GW’s assistant extension keypad, you have to connect NuPAD’s Connection Port with NuStreams-P6GW’s Console Port with a CAT-5 straight-through cable first. The figure down below is an installation example of connecting NuStreams-P6GW and NuPAD.
After connecting NuStreams-P6GW with CAT-5 straight-through cable, NuPAD will start establishing connection with NuStreams-P6GW, and its LCD will display system status as shown down below.
1. NuPAD is powering up.
2. Showing NuPAD’s hardware and firmware version.
3. NuPAD is starting connecting with NuStreams-P6GW. During this process, NuPAD’s buzzer will be beeping.
4. Connection established, and NuPAD’s buzzer stops beeping. If NuPAD’s buzzer keeps beeping and the connection between NuStreams-P6GW and NuPAD can’t be established, please power off both NuStreams-P6GW and NuPAD, power them on, and try again.
Please note that NuStreams-P6GW cannot be connected to your PC and its LCD should be on the Main Display menu when connecting NuStreams-P6GW with NuPAD for controlling DUT tests.
Page 77
77
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
6.3. Starting DUT Tests with NuPAD
NuPAD has 3 buttons on its front panel: “|| Pause”, “ Stop”, and “
Run”. After connecting NuPAD
with NuStreams-P6GW with Cat-5 cable, you can start/pause/stop DUT tests with these 3 buttons. Please see the table down below for a detailed description about these buttons’ functions.
Function Button Description
Start Testing All
Tasks in Current Run
Run
Press “ Run” to start all Tasks in the current Run. The current Run (Run 1~3) about to be tested will be displayed on the upper-right part of LCD.
Switching Current
Run
|| Pause
+
Stop
To change the current Run (Run 1~3), press both “|| Pause” and “Stop” buttons at the same time. If NuPAD is current in Run 1, pressing both “|| Pause” and “Stop” buttons at the same time will switch the current Run from Run 1 to Run 2.
Pause Current
Running Test
|| Pause
Press “|| Pause” button once to pause the current running test. Press “|| Pause” button again to resume the test.
Stop Current
Running Test
Stop
Press “■Stop” button once to stop the current running test.
Page 78
78
Note: Information and specifications contained in this document are subject to change without notice. Note: Information and specifications contained in this document are subject to change without notice.
All products and company names are trademarks of their respective corporations. All products and company names are trademarks of their respective corporations.
Copyright © 2011 Xtramus Technologies, all rights reserved. Copyright © 2011 Xtramus Technologies, all rights reserved.
Do not reproduce, redistribute or repost without written permission from Xtramus. Do not reproduce, redistribute or repost without written permission from Xtramus.
Doc # USM_NuStreams-P6GW_V1.0_ENG_Preliminary_20111 014 Doc # USM_NuStreams-P6GW_V1.0_ENG_Preliminary_20111 014
78
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES®
Loading...