Xtramus 2544 User Manual

Page 1
NuApps-2544
User’s Manual
Page 2
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
Xtramus Technologies E-mail: sales@xtramus.com Website: www.xtramus.com Tel: +886-2-8227-6611 Fax: +886-2-8227-6622

Copyright

Copyright © 2008 Xtramus Technologies. All Rights Reserved. The information contained in this document is the property of Xtramus Technologies. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, without the prior written permission of Xtramus Technologies.

Disclaimer

The information contained in this document is subject to change without notice and does not represent a commitment on the part of Xtramus Technologies. The information in this document is believed to be accurate and reliable, however, Xtramus Technologies assumes no responsibility or liability for any errors or inaccuracies that may appear in the document.

Trademarks

NuApps-2544 is the trademark or registered trademark of Xtramus Technologies. All other trademarks and registered trademarks are the property of their respective owners.

Warranty

Xtramus Technologies warrants to recipient that software it supplies with this document will be free from significant defects for a period of twelve (12) months from the date of delivery, under normal use and conditions. Defective Product under warranty shall be, at Xtramus Technologies’ discretion, repaired or replaced. To the extent permitted by applicable law, all implied warranties, including but not limited to implied warranties of merchantability, non-infringement and fitness for a particular purpose, are hereby excluded, and the liability to Xtramus Technologies, if any, for damages relating to any allegedly defective product shall be limited to the actual price paid by the purchaser for such product. In no event will Xtramus Technologies be liable for costs of procurement of substitute products or services, lost profits, or any special, direct, indirect, consequential, or incidental damages, however caused and on any theory of liability, arising in any way out of the sale and/or license of products or services to recipient even if advised of the possibility of such damages and notwithstanding any failure of essential purpose of any limited remedy.
Page 3
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
Date
SW Version
FPGA Version
FW Version
USM Version
History
Oct. 10, 2008
V2.0.b8
V1.0
REVISION HISTORY
Page 4
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com

TABLE OF CONTENTS

1. Introduction ........................................................................................................ 1
1.1 System Requirements ...................................................................................... 1
2. Installation and Uninstallation ............................................................................ 2
2.1 Installation ....................................................................................................... 2
2.2 Uninstallation ................................................................................................... 3
3. Start NuApps-2544 ............................................................................................ 4
4. Main Window ..................................................................................................... 6
4.1 Main Menu ....................................................................................................... 6
4.1.1 File Menu .................................................................................................................. 6
4.1.2 View Menu ................................................................................................................ 6
4.1.3 Run Menu ................................................................................................................. 6
4.1.4 Help Menu ................................................................................................................ 6
5. Port Configuration .............................................................................................. 7
5.1 Transmission ................................ ................................................................ ... 7
5.1.1 One to One Transmission ......................................................................................... 7
5.1.2 One to Many (Many to One) Transmission .............................................................. 8
5.2 Bi-Directional ................................................................ ................................... 8
5.3 Port Settings .................................................................................................... 9
6. Test Configuration ........................................................................................... 10
7. Throughput Test .............................................................................................. 12
8. Latency Test .................................................................................................... 13
9. Packet Loss Test ............................................................................................. 14
10. Back-to-Back Test ......................................................................................... 15
11. Test Results ................................................................................................... 16
12. Logs ............................................................................................................... 18
Page 5
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

1. Introduction

Card Type
Throughput
Test
Latency
Test
Packet Loss
Test
Back-to-Back
Test
XM-2202
√ √ √
XM-2301(G)
√ X √
XM-23L4(G)
√ X √
XM-28L1(CX4)
√ X √
XM-22R4
√ √ √
XM-23R2
√ √ √
NuApps-2544 is a test suite based on RFC-1242 and RFC-2544 for analyzing Ethernet switches, bridges, and routers. The multiple topologies and the load generation capabilities provide an effective way to evaluate Throughput, Latency, Packet Loss, and Back-to-Back of a DUT in One-to-One, One-to-Many, Many-to-One configurations. The real time display of test results and various customizable report formats make it easy to view the test data and organize them into an appropriate form for debug, report, and record.
Please note that the Latency test of NuApps-2544 is supported by XM-2202, XM-22R4 (port 1 must pair with port 2; port 3 with port 4), and XM-23R2 only when 2 ports are connected within the same module.

1.1 System Requirements

NuStreams-2000/ 600 IBM or P3 compatible PC with at least a 256 MB RAM or above 20 MB free HD space Windows 2000/ XP Supported Card Modules
1
Page 6
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

2. Installation and Uninstallation

Bring out the InstallShield Wizard to prepare to install.
Start Apps-2544 software installation. Click Next to go to next step.
Read license agreement carefully before selecting to accept all terms and click Next to go to next step.
Set for the destination default route. Click Next for next step.
Review and confirm installation settings.

2.1 Installation

Double click NuApps-2544.exe to start installing the software.
2
Page 7
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan
Click Install for next step.
NuApps-2544 installation is in progress.
NuApps-2544 has been installed successfully. Click Finish to exit the Wizard.
The icon appears on the desktop.

2.2 Uninstallation

If applications do not work properly, it may be necessary to uninstall the software. Or before updating a new version of the software, the previous version must be uninstalled first.
There are two ways to uninstall NuApps-2544: Start Menu or Control Panel.
Start Menu: Click on Windows Start menu Programs Xtramus NuApps-
2544 Uninstall NuApps-2544.
Control Panel: Activate the Control Panel Add/Remove Programs NuApps-
2544 Change/Remove.
3
Page 8
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

3. Start NuApps-2544

Click NuApps-2544 icon to start the software.
Click Yes to bring up the local server.
Choose the NIC at which the server is located. In this case, it’s the NDIS 5.0 driver.
This is the main window of NuApps-2544. Please click the Connect to Server button on the lower right of the window.
4
Page 9
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan
Use the scroll bar to show the IP address of the NDIS 5.0 driver. In this case, it’s
192.168.1.1.
5
Page 10
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

4. Main Window

Open an existing configuration. Save the current active configuration to
current workplace. Save the current configuration in a new file.
Exit NuApps-2544.
Bring out the first toolbar. Bring out the second toolbar. Bring out the status bar in bottom window. Switch window between results and configuration.
Run whichever the prior test(s). Stop whichever the test(s) in progress. Print out the test results. Show preview before printout. Save current results to an Excel file. Go back to configuration window.
Show information of NuApps-2544 version.

4.1 Main Menu

The main window of the user interface is illustrated below. The top-level menu includes the following major parts: File, View, Run and Help.
The menu toolbar on the top includes four submenus.

4.1.1 File Menu

4.1.2 View Menu

4.1.3 Run Menu

Note: any of these functions could not be available and activated after any test is run.

4.1.4 Help Menu

6
Page 11
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

5. Port Configuration

5.1 Transmission

NuApps-2544 supports two directions of transmission: 1 port to 1 port and 1 port to multiple ports (multiple ports to 1 port).

5.1.1 One to One Transmission

In this section, 1 to 1 transmission is demonstrated.
In this demonstration, two XM-2202 module cards, each has two 10/100M ports individually, are inserted into the NuStreams chassis.
Choose any two of the ports…
and use the arrow key to pair them off. The following tab will be invoked when any port is chosen.
7
Page 12
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

5.1.2 One to Many (Many to One) Transmission

Choose 1 to M . The transmission mode is set as the source port sending traffic to the other ports.
Use the arrow button to change direction for transmission. In this case, 1 to M mode is switched to M to 1 mode.

5.2 Bi-Directional

Check the button to run the test in two-way mode.
If it is desired to configure multiple ports all at once, click this button
Note: Latency Test does not support this function yet with the box checked.
to invoke Config All Ports table.
8
Page 13
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

5.3 Port Settings

Configure setting for individual port here. Please note that only two tabs are provided, so only configure two ports at once.
Activate flow control to enforce transmitting port to send packets in same
speed with receiving port.
9
Page 14
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

6. Test Configuration

To edit test configuration, use this dialogue. Choose the tabs of any four standard tests. For the tab of Latency, choose Performing Synchronization to start the feature.
Use the dialogue of General (Packet Size) to edit the range for packet size variation.
Click Use Custom to invoke the window of Packet Size Customization for more detailed settings.
Choose Learning Mode to enable the Device under Test (DUT) to create an address table according to the source address in the received frame. If Never is chosen, the
10
Page 15
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan
address of current port will not be built into the table. If Once is chosen, the address of current port will be learned to be built into the table only once. If Every Trial is chosen, the address of current port will be built into the table very time. For Learning Retry, fill in the number of packets to be sent through the ports chosen to be learned for building address table.
Use this dialogue to activate layer 3 test. Choose Enable Router Test to start the test.
Choose Perform Next Hop Test to test the next layer 3 switch.
11
Page 16
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

7. Throughput Test

Press the test launch button to start the Throughput test. The individual test tab for the Throughput test will show after the test launch button is clicked.
Throughput Test determines the maximum throughput rate at which a DUT can support the transmission of packets without dropping one. The test duration, packet length, packet transmission rate can all be customized to meet the desired test condition. In this case, the throughput of traffic from port (0,2,1) to port (0,2,2) is 148,809 bps with 64-byte packets.
Use the tabs at the bottom of the window to activate the individual Throughput test tab. To end the test, press . Press to return to the main window.
12
Page 17
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

8. Latency Test

Press the test launch button to start the Latency test. The individual test tab for the Latency test will show after the test launch button is clicked.
NuApps-2544 provides the Latency information of DUT by measuring the time it takes to forward a packet while under load. The load generated by NuStreams-2000/600 can be customized in accordance with different packet length and last for a specified period of time.
Use the tabs at the bottom of the window to activate the individual Latency test tab. To end the test, press . Press to return to the main window.
13
Page 18
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

9. Packet Loss Test

Press the test launch button to start the Packet Loss test. The individual test tab for the Packet Loss test will show after the test launch button is clicked.
By measuring the percentage of packets that are not forwarded because of lack of resource, the Packet Loss rate of DUT can be determined. The loading, and test duration can be customized to simulate real-world scenario; thus, giving the user a clear view of the performance limits of the DUT under different loading environments.
Use the tabs at the bottom of the window to activate the individual Packet Loss test tab. To end the test, press . Press to return to the main window.
14
Page 19
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

10. Back-to-Back Test

Press the test launch button to start the Back-to-Back test. The individual test tab for the Back-to-Back test will show after the test launch button is clicked.
Back-to-Back Test measures the buffer capacity of the DUT by sending bursts of traffic at the maximum frame rate and by measuring the longest burst size for which no packets are dropped. For each packet length specified in test setup, the test is automatically repeated to provide an accurate view of the buffer capacity of the DUT under different conditions.
Use the tabs at the bottom of the window to activate the individual Back-to-Back test tab. To end the test, press . Press to return to the main window.
15
Page 20
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

11. Test Results

Test Results includes all four individual tests: Throughput, Latency, Packet Loss, and Back-to-Back.
Use the tabs at the bottom of the window to activate the Reports tab. Scroll down the bar on the right side to see the complete test report data.
Test Report for Throughput Part
Test Report for Latency Part
Test Report for Packet Loss Part
16
Page 21
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan
Test Report for Back-to-Back Part
Press to return to the main window.
17
Page 22
Tel: +886-2-8227-6611
Fax: +886-2-8227-6622
E-Mail: sales@xtramus.com
Http://www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
5th Floor, No. 102, Lide Street, Junghe City, Taipei County 235, Taiwan

12. Logs

The Logs tab records detailed operation record.
Use the tabs at the bottom of the window to activate the Logs tab.
18