XPower P-830, P-800H-BLUE, X-830, X-830H User Manual

P-800 / P-800H / P-830 / P-830H X-800 / X-800C / X-800H / X-800TF X-830 / X-830H (115V / 60Hz)
XPOWER Air Movers are ETL/CETL Certified Professional Level Multifunctional Air Movers with the most efficient engineering design.
Features:
• Low power draw with an high velocity air flow from 3,200 to 3,600 CFM
• Super quiet motor and super lightweight.
• Easy and quick to disassemble for thorough cleaning and service.
• Power cord lengths are 20’ for P models and 25’ for X models.
• Easy cord wrap on handle.
• Luggage handle and wheels for "H" series models.
• Carpet clamp for "C" series models.
• Timer and filter for "TF" series models.
• 3-speed switch.
• Durable and rugged housing with 5 years warranty.
• 3 air-flow positions for “H” series models (0°, 20° Kickstand, 90°).
• 4 air-flow positions for other models (0°, 20°, 45°, 90°).
45°
XPOWER Air Movers are intended to move air and to dry floors, walls, furniture, etc. Durable and easy to operate with an effective balance of static pressure and airflow, the units are suitable for a variety of applications.
1. XPOWER Air Movers are shipped ready-to-use. Prior to plugging the unit into the power source, inspect completely for any shipping damage.
2. Plug the electrical cord into the power outlet.
3. Carefully place the Air Mover unit on a stable, flat dry surface.
4. The unit is capable to be used at 4 different angles to direct air flow, except that the unit with handle is at 3 different angles.
5. Turn the switch to select desired speed, while making sure unit operates normally.
6. All Air Movers in operation must be supervised
at all times.
(For X-800TF model)
TM
Air Movers can be stacked (up to 3) on their sides for storage.
NOTICE:
Stacking feature is not secure for transportation. Must remove the filters before stacking. (For unit with filters)
1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug
the unit with wet hands or while standing in water.
2. To avoid risk of injury, do not direct air flow at face or any part of body.
3. To reduce the risk of fire or electric shock, do not use the Air Mover with any solid-state speed
control device.
4. Use only with GFCI protected receptacles. Please contact a qualified electrician for verification and / or install GFCI receptacle if necessary.
5. Do not operate any Air Mover with a damaged cord or plug. Discard the unit or return it to an authorized service facility for examination and/or repair.
6. Unplug the Air Mover from the power supply before moving, servicing or cleaning.
7. Do not run the power cord under carpeting. Do not cover the power cord with throw rugs, runners, or similar coverings. Place the power cord away from traffic area to prevent tripping.
8. Do not allow children to play with or around an Air Mover at any time.
9. Do not move or carry an Air Mover while unit is operating.
10. All Air Movers in operation must be supervised at all times.
2. Never clean the Air Mover with water directly. When not in use, unplug and store the Air Mover in a dry indoor place out of reach of children.
Clean the filters ( for unit with filters) often as necessary to avoid loss of airflow when available.5.
Air Mover
vibrates
Model P-800/X-800 P-800H/X-800H X-800C X-800TF P-830/X-830 P-830H/X-830H
Volt/Frequency
Power
Amp
Unit Weight
Speeds
Size(WxDxH)
Handle/Wheels
Carpet clamp
Timer
Filter
Cord Length
Overheating Protecting
Rated Airflow (on high)
Positions
Housing
115V,60Hz 115V,60Hz 115V,60Hz 115V,60Hz 115V,60Hz 115V,60Hz
3/4 HP 3/4 HP 3/4 HP 3/4 HP 1 HP 1 HP
7.5 Amps 7.5 Amps 7.5 Amps 7.5 Amps 8.5 Amps 8.5 Amps
23Lbs./24.5Lbs. 26Lbs./27.5Lbs. 24.7Lbs. 24.7Lbs. 24Lbs./25.5Lbs. 27Lbs./28.5Lbs.
Three Three Three Three Three Three
15.9x17.5x18.5 in. 15.9x18.7x18.7 in. 15.9x17.5x18.5 in. 15.9x17.5x18.5 in. 15.9x17.5x18.5 in. 15.9x18.7x18.7 in.
Optional Incl. Optional Optional Optional Incl.
Optional Optional Incl. Optional Optional Optional
N.A. N.A. N.A. Incl. N.A. N.A.
Optional Optional Optional Incl. Optional Optional
20 Ft. / 25 Ft. 20 Ft. / 25 Ft. 25 Ft. 25 Ft. 20 Ft. / 25 Ft. 20 Ft. / 25 Ft.
Thermally
Protected
3200 CFM 3200 CFM 3200 CFM 3200 CFM 3600 CFM 3600 CFM
4(0°, 20°, 45°, 90°) 3 (0°, 20°, 90°) 4(0°, 20°, 45°, 90°) 4(0°, 20°, 45°, 90°) 4(0°, 20°, 45°, 90°) 3 (0°, 20°, 90°)
PP / ABS PP / ABS ABS ABS PP / ABS PP / ABS
Thermally
Protected
Thermally
Protected
Thermally
Protected
Thermally
Protected
Thermally
Protected
* All models are ETL/CETL certified
XPOWER Warranty covers the unit from defects in materials and craftsmanship. The Warranty covers normal use for a term of one year from the original date of purchase including parts, labor and one way shipping. The XPOWER Air Mover Housing and handle are covered for a term of five years from the date of original purchase.
This Warranty does not cover signs of misuse including, but not limited to, a unit that has been dropped, subjected to water damage, tampered with, improper voltage use and unauthorized maintenance and repairs. The POWER CORD and filters are not covered by the warranty.
Call for a Return Merchandise Authorization (RMA) number through our Service Department
A.
and obtain ship back instructions. Have original proof of purchase.
B.
Use original non damaged packaging or Industrial certified packaging method.
C.
800 Series Parts List
800-1
800-3
800-5
800-7
800-9
800-11
800-13
800-15
16
Timer & Switch Plate
Capacitor
4-2
4-1
800-2
800-4-1/2 Switch Knob & Timer Knob
800-6
800-8
800-10
800-12
800-14
Filters800-16
15
16
Luggage Handle & Wheels (for 800H and 830H models)
XPOWER Air Mover Model P-800H, P-830H, X-800H and X-830H comes with built-in extendable luggage handle and wheels for easy transportation and mobility.
Carpet clamp (for 800C models)
XPOWER Air Mover Model X-800C, comes with a carpet clamp specifically for drying under the carpets.
Filters (Optional)
A set of Filters is available for the Air Mover models which will help prevent small debris and dust
from entering the unit. To clean the filters: Remove the filters from the unit and wash with warm
soapy water, rinse with clean water and let dry thoroughly before reinstalling.
Installation: Filters snaps into the air inlets.
Note: The filter I is for Motor Side, The filter II is for Fan Side
Filter Removal: Pull the filters off the unit.
Note: After cleaning make sure the filters are dry before
reinstalling.
Please complete and mail or fax for your product warranty. For a multiple units, please list serial numbers on a separate sheet of paper. Address: XPOWER MANUFACTURE, INC, 220 Clary Avenue San Gabriel, CA 91776, USA Tel: (626) 285-3301; Fax: (626) 285-3302
Company Name / Contact Person / Title
State / Province
Zip Country
P-800 / P-800H / P-830 / P-830H X-800 / X-800C / X-800H / X-800TF X-830 / X-830H (115V / 60Hz)
XPOWER Air Movers are ETL/CETL Certified Professional Level Multifunctional Air Movers with the most efficient engineering design.
Features:
• Low power draw with an high velocity air flow from 3,200 to 3,600 CFM
• Super quiet motor and super lightweight.
• Easy and quick to disassemble for thorough cleaning and service.
• Power cord lengths are 20’ for P models and 25’ for X models.
• Easy cord wrap on handle.
• Luggage handle and wheels for "H" series models.
• Carpet clamp for "C" series models.
• Timer and filter for "TF" series models.
• 3-speed switch.
• Durable and rugged housing with 5 years warranty.
• 3 air-flow positions for “H” series models (0°, 20° Kickstand, 90°).
• 4 air-flow positions for other models (0°, 20°, 45°, 90°).
45°
XPOWER Air Movers are intended to move air and to dry floors, walls, furniture, etc. Durable and easy to operate with an effective balance of static pressure and airflow, the units are suitable for a variety of applications.
1. XPOWER Air Movers are shipped ready-to-use. Prior to plugging the unit into the power source, inspect completely for any shipping damage.
2. Plug the electrical cord into the power outlet.
3. Carefully place the Air Mover unit on a stable, flat dry surface.
4. The unit is capable to be used at 4 different angles to direct air flow, except that the unit with handle is at 3 different angles.
5. Turn the switch to select desired speed, while making sure unit operates normally.
6. All Air Movers in operation must be supervised
at all times.
(For X-800TF model)
TM
Air Movers can be stacked (up to 3) on their sides for storage.
NOTICE:
Stacking feature is not secure for transportation. Must remove the filters before stacking. (For unit with filters)
1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug
the unit with wet hands or while standing in water.
2. To avoid risk of injury, do not direct air flow at face or any part of body.
3. To reduce the risk of fire or electric shock, do not use the Air Mover with any solid-state speed
control device.
4. Use only with GFCI protected receptacles. Please contact a qualified electrician for verification and / or install GFCI receptacle if necessary.
5. Do not operate any Air Mover with a damaged cord or plug. Discard the unit or return it to an authorized service facility for examination and/or repair.
6. Unplug the Air Mover from the power supply before moving, servicing or cleaning.
7. Do not run the power cord under carpeting. Do not cover the power cord with throw rugs, runners, or similar coverings. Place the power cord away from traffic area to prevent tripping.
8. Do not allow children to play with or around an Air Mover at any time.
9. Do not move or carry an Air Mover while unit is operating.
10. All Air Movers in operation must be supervised at all times.
Model P-800/X-800 P-800H/X-800H X-800C X-800TF P-830/X-830 P-830H/X-830H
Volt/Frequency
Power
Amp
Unit Weight
Speeds
Size(WxDxH)
Handle/Wheels
Carpet clamp
Timer
Filter
Cord Length
Overheating Protecting
Rated Airflow (on high)
Positions
Housing
115V,60Hz 115V,60Hz 115V,60Hz 115V,60Hz 115V,60Hz 115V,60Hz
3/4 HP 3/4 HP 3/4 HP 3/4 HP 1 HP 1 HP
7.5 Amps 7.5 Amps 7.5 Amps 7.5 Amps 8.5 Amps 8.5 Amps
23Lbs./24.5Lbs. 26Lbs./27.5Lbs. 24.7Lbs. 24.7Lbs. 24Lbs./25.5Lbs. 27Lbs./28.5Lbs.
Three Three Three Three Three Three
15.9x17.5x18.5 in. 15.9x18.7x18.7 in. 15.9x17.5x18.5 in. 15.9x17.5x18.5 in. 15.9x17.5x18.5 in. 15.9x18.7x18.7 in.
Optional Incl. Optional Optional Optional Incl.
Optional Optional Incl. Optional Optional Optional
N.A. N.A. N.A. Incl. N.A. N.A.
Optional Optional Optional Incl. Optional Optional
20 Ft. / 25 Ft. 20 Ft. / 25 Ft. 25 Ft. 25 Ft. 20 Ft. / 25 Ft. 20 Ft. / 25 Ft.
Thermally
Protected
3200 CFM 3200 CFM 3200 CFM 3200 CFM 3600 CFM 3600 CFM
4(0°, 20°, 45°, 90°) 3 (0°, 20°, 90°) 4(0°, 20°, 45°, 90°) 4(0°, 20°, 45°, 90°) 4(0°, 20°, 45°, 90°) 3 (0°, 20°, 90°)
PP / ABS PP / ABS ABS ABS PP / ABS PP / ABS
Thermally
Protected
Thermally
Protected
Thermally
Protected
Thermally
Protected
Thermally
Protected
* All models are ETL/CETL certified
2. Never clean the Air Mover with water directly. When not in use, unplug and store the Air Mover in a dry indoor place out of reach of children.
Clean the filters ( for unit with filters) often as necessary to avoid loss of airflow when available.5.
Air Mover
vibrates
XPOWER Warranty covers the unit from defects in materials and craftsmanship. The Warranty covers normal use for a term of one year from the original date of purchase including parts, labor and one way shipping. The XPOWER Air Mover Housing and handle are covered for a term of five years from the date of original purchase.
This Warranty does not cover signs of misuse including, but not limited to, a unit that has been dropped, subjected to water damage, tampered with, improper voltage use and unauthorized maintenance and repairs. The POWER CORD and filters are not covered by the warranty.
Call for a Return Merchandise Authorization (RMA) number through our Service Department
A.
and obtain ship back instructions. Have original proof of purchase.
B.
Use original non damaged packaging or Industrial certified packaging method.
C.
800 Series Parts List
800-1
800-3
800-5
800-7
800-9
800-11
800-13
800-15
16
Timer & Switch Plate
Capacitor
4-2
4-1
800-2
800-4-1/2 Switch Knob & Timer Knob
800-6
800-8
800-10
800-12
800-14
Filters800-16
15
16
Please complete and mail or fax for your product warranty. For a multiple units, please list serial numbers on a separate sheet of paper. Address: XPOWER MANUFACTURE, INC, 220 Clary Avenue San Gabriel, CA 91776, USA Tel: (626) 285-3301; Fax: (626) 285-3302
Company Name / Contact Person / Title
State / Province
Zip Country
Luggage Handle & Wheels (for 800H and 830H models)
XPOWER Air Mover Model P-800H, P-830H, X-800H and X-830H comes with built-in extendable luggage handle and wheels for easy transportation and mobility.
Carpet clamp (for 800C models)
XPOWER Air Mover Model X-800C, comes with a carpet clamp specifically for drying under the carpets.
Filters (Optional)
A set of Filters is available for the Air Mover models which will help prevent small debris and dust
from entering the unit. To clean the filters: Remove the filters from the unit and wash with warm
soapy water, rinse with clean water and let dry thoroughly before reinstalling.
Installation: Filters snaps into the air inlets.
Note: The filter I is for Motor Side, The filter II is for Fan Side
Filter Removal: Pull the filters off the unit.
Note: After cleaning make sure the filters are dry before
reinstalling.
Loading...