XPiQ inc PUP56-12, PUP56-13, PUP56-13-1, PUP56-14, PUP56-16 Datasheet

...
96
DESCRIPTION
The PUP56 Series of AC/DC switching power supplies provide 55 watts of continuous output power. They are enclosed in a 94V-1 rated polyphenylene-oxide case with an IEC320 inlet connector to mate with an interchangeable cord for worldwide use. All models meet CISPR 22 and FCC Class B emission limits, and comply with UL, CSA, IEC and CE requirements.
FEATURES
Built-in EMI filter
Overvoltage protection
Overcurrent protection
Input surge current protection
Wide input voltage 85 to 264 VAC
100% burn-in at full load
Optional on/off switch
Output Maximum
Output
Model Vnom Imin Imax Tol. Power
PUP56-12 12V 0A 4.2A 3% 50W PUP56-13 15V 0A 3.7A 3% 55W PUP56-13-1 18V 0A 3.1A 3% 55W PUP56-14 24V 0A 2.3A 3% 55W PUP56-16 30V 0A 1.9A 3% 55W PUP56-17 36V 0A 1.6A 3% 55W PUP56-18 48V 0A 1.2A 3% 55W
OUTPUT VOLTAGE/CURRENT RATINGS CHART
NEW • DESKTOP POWER SUPPLIES
• UNIVERSAL INPUT
• COMPACT FORM FACTOR
®
International Power Sources, Inc.
55 WATT
SWITCHING
POWER SUPPLY
U
L
®
97
GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25°C.
Efficiency: 75% minimum Hold-up time: 10msec minimum at 110 VAC Line regulation: ±0.5% maximum at full load Inrush current: 15A@115 VAC or 30A@
230 VAC at 25°C cold start
Withstand voltage: 3000 VAC from input to output
1500 VAC from input to ground 500 VAC from output to ground
Insulation resistance: 10 Mohm minimum from output
to ground Operating temperature: 0°C to 60°C* Storage temperature: –40°C to +85°C Relative humidity: 5% to 95% non-condensing MTBF: 100,000 hours minimum at
full load at 25°C ambient EMI requirements: In compliance with radiated and
conducted limits of CISPR 22
(EN 55022) Class B and FCC Class B Safety requirements: Approved to:
a) UL 1950
b) CSA C22.2 No. 234
c) IEC 950 (EN60950) Switching frequency: 85KHz ±10KHz
INPUT SPECIFICATIONS
Input voltage: 85 to 264 VAC Input frequency: 47 to 63 Hz Input current: 1.22A (rms) for 115 VAC
0.76A (rms) for 230 VAC Safety ground 0.47mA max. @ 110VAC 60 Hz leakage current: 0.85mA max. @ 240VAC 50 Hz
OUTPUT SPECIFICATIONS
Total output power: See Rating Charts Ripple and noise: 1% peak to peak maximum Overvoltage protection: Set at 112-132% of
nominal output voltage
Overcurrent protection:
Protected under short circuit conditions Temperature coefficient: ±0.04%/°C maximum Transient response: Maximum excursion of 4% or better
on all models, recovering to 1% of
final value 500us after a 25% step
load change
* Derate linearly from 100% load at 40°C to 50% load at 60°C
PIN CHART
Model PIN 12345
PUP56-12 PUP56-13 PUP56-13-1 PUP56-14 RETURN RETURN OUTPUT RETURN OUTPUT PUP56-16 PUP56-17 +V +V PUP56-28
NOTES: 1. Dimensions shown in inches (mm) 3. Optional output connectors available 5. Weight: 500 grams
2. Tolerance 0.02 (0.5) maximum 4. Optional on/off switch
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL: (508) 429-4440 FAX: (800) 226-2100
http://www.intlpower.com
International
Power Sources, Inc.
Loading...