55 Watts
PUP55 Series
Built-in EMI Filter
•
Dual and Triple Outputs
•
100% Burn-In
•
International Safety Approvals
and CE Mark
•
Input Surge Protection
•
Wide Input Voltage 85 to 264 VAC
•
•
•
Specification
All specifications typical at nominal line, full load and 25°C
Intelligent Design Quality Product
XPiQ inc.
AC/DC Desktop
Input
Input Voltage • 85-264 VAC
Input Frequency • 47 to 440 Hz
Input Current • 1.5A (rms) for 115 VAC
0.9A (rms) for 230 VAC
Output
Output Power Range • 0 to 55 watts
Output Voltage • See Tables
Output Current • See Tables
Ripple and Noise • 1% peak to peak max.
Overvoltage • Provided on output #1 only
Protection set at 112-132% of its nominal
output voltage
Overcurrent • All outputs protected to short
Protection: circuit conditions
Temperature • All outputs ±0.04%/°C
Coefficient: maximum
General
Efficiency • 70% minimum at 55W output
Hold-up time • 10 msec minimum at 115 VAC
Line Regulation • ±0.5% maximum at full load
Inrush Current • 15A at 115 VAC or
30A at 230 VAC at 25°C cold start
Withstand Voltage • 3000 VAC from input to output
1500 VAC from input to ground
Insulation Resistance • 10 Mohm minimum from
output to ground
Environmental
Operating • 0°C to +70°C*
Temperature
Storage • -40°C to +85°C
Temperature
MTBF • 100,000 hours minimum at full load
at 25°C ambient
EMI Requirements • Meets conducted limits of
FCC 20780 level B, CISPR 22
(EN 55022) level B
Safety Requirements • Approved to:
a) UL 1950
b) CSA C22.2 No. 234
c) IEC 950
* Derate linearly from 100% load at 50°C to 100% load at 70°C
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.XP-iQ.com
141