XPiQ inc PUP30-10, PUP30-12, PUP30-13, PUP30-13-1, PUP30-14 Datasheet

...
92
9292
92
DESCRIPTION
The PUP30 Series of AC/DC switching power supplies provide 30 watts of continuous output power. They are enclosed in a 94V-0 polycarbonate case with an IEC320 inlet connector to mate with an interchangeable cord for worldwide use. All models meet VDE class B and FCC class B emission limits, and are approved to UL, CSA, and TUV safety standards.
• DESKTOP POWER SUPPLIES
• UNIVERSAL INPUT
FEATURES
13 standard desktop models
Single, dual or triple outputs
Optional output connectors
100% burn-in
Wide input voltage 85 to 264 VAC
Input surge current protection
Overvoltage protection
Overcurrent protection
OUTPUT VOLTAGE/CURRENT RATINGS CHART
Output #1 Output #2 Output #3 Maximum
Output
Model Vnom Imin Imax Tol. Vnom Imin Imax Tol. Vnom Imin Imax Tol. Power
PUP30-10 5V 0A 5.0A 3% N/A N/A 25W PUP30-12 12V 0A 2.7A 2% N/A N/A 30W PUP30-13 15V 0A 2.3A 2% N/A N/A 30W PUP30-13-1 18V 0A 1.7A 2% N/A N/A 30W PUP30-14 24V 0A 1.4A 2% N/A N/A 30W PUP30-16 30V 0A 1.1A 2% N/A N/A 30W PUP30-17 36V 0A 0.9A 2% N/A N/A 30W PUP30-18 48V 0A 0.7A 2% N/A N/A 30W PUP30-23 +5V 0.3A 3.0A 5% +12V 0.1A 2.0A 5% N/A 30W PUP30-24 +5V 0.3A 3.0A 5% +15V 0.1A 1.5A 5% N/A 30W PUP30-25 +5V 0.3A 3.0A 5% +24V 0.1A 1.0A 5% N/A 30W PUP30-31 +5V 0.3A 3.0A 5% +12V 0A 0.8A 5% -12V 0A 0.8A 5% 30W PUP30-32 +5V 0.3A 3.0A 5% +15V 0A 0.8A 5% -15V 0A 0.8A 5% 30W
NOTE: All multiple output units may be operated at no-load without damage. At no-load, output tolerance increases to 10%.
International Power Sources, Inc.
30 WATT
SWITCHING
POWER SUPPLY
®
U
L
®
939393
93
GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25°C.
Efficiency: 65% minimum at 30W output Hold-up time: 10 msec minimum at 115 VAC Line regulation: ±0.5% maximum at full load Inrush current: 15 amps @ 115 VAC, or
30 amps @ 230 VAC at 25°C cold start
Withstand voltage: 3000 VAC from input to output
1500 VAC from input to ground 500 VAC from output to ground
Insulation resistance: 10 Mohm minimum from output
to ground Operating temperature: 0 to 70°C* Storage temperature: -40 to +85°C Mean time between 100,000 hours minimum at full load failure: at 25°C ambient EMI requirements: Meets conduction and radiated limits of:
a) FCC 20780 Level B
b) CISPR 22 (EN 55022) Level B Safety requirements: Meets or exceeds
a) UL 1950
b) CSA C22.2 No. 234
c) IEC 950
INPUT SPECIFICATIONS
Input voltage: 85 to 264 VAC Input frequency: 47 to 440 Hz Input current: 0.85A (rms) for 115 VAC
0.50A (rms) for 230 VAC Safety ground 0.85mA max. @ 240 VAC 50Hz leakage current
OUTPUT SPECIFICATIONS
Output voltage: See Rating Charts Output current: See Rating Charts Output power range: 0 to 30 Watts Ripple and noise: 1% peak to peak maximum Overvoltage protection: Provided on output #1 only; set at
112-132% of its nominal output voltage.
Overcurrent protection: All outputs protected to short
circuit conditions Temperature Coefficient: All outputs ±0.04%/°C maximum Transient response: Maximum excursion of 4% on all
models recovering to 1% of final
value within 500 uS after a 25%
step load change.
* Derate linearly from 100% load at 50°C to 50%0 load at 70°C
PIN CHART
MECHANICAL SPECIFICATIONS
NOTE:
1. Dimensions shown in inches (mm)
2. Tolerance 0.02[0.5] maximum
3. Weight: 500 grams approx.
4. Consult factory for optional output connectors
*AMP Receptacle No. 212044-1 or Equivalent
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL: (508) 429-4440 FAX: (800) 226-2100
http://www.intlpower.com
International
Power Sources, Inc.
Model PIN 1 2 3 4 5
PUP30-10, PUP30-12, PUP30-13 PUP30-13-1, PUP30-14, PUP30-16 RETURN RETURN
OUTPUT
RETURN
OUTPUT
PUP30-17, PUP30-18,
#1 #1
PUP30-23, PUP30-24, PUP30-25 COMMON COMMON
OUTPUT
COMMON
OUTPUT
#1 #2
PUP30-31, PUP30-32, COMMON COMMON
OUTPUT OUTPUT OUTPUT
#1 #3 #2
Loading...