XPiQ inc PU200-23B, PU200-23C, PU200-24B, PU200-24C, PU200-25B Datasheet

...
7676
76
DESCRIPTION
The PU200 Series is comprised of single and multiple output models for 200 watts of continuous output power. Auto ranging input allows them to operate from any line voltage throughout the world without a selector strap. All auxiliary outputs have magnetic amplifier or linear regulators to maintain tight output tolerances. A cover-and-fan assembly are optional. All models meet VDE Class B and FCC Class B emission limits, and are approved to UL, CSA, and, TUV safety standards.
• AUTO-RANGING INPUT
FEATURES
Auto-ranging input
Built-in EMI filter
Short circuit protection with auto-recovery
Power fail detection
100% burn-in at full rated load
Optional cover-and-fan assembly
Small size 9.0”x 5.0”x 2.55”
OUTPUT VOLTAGE/CURRENT RATINGS CHART
Output #1 Output #2 Output #3 Output #4
2
Maximum
Output
Model Vnom Imin Imax Tol. Vnom Imin Imax Ipeak Tol. Vnom Imin Imax Tol. Vnom Imin Imax Tol. Power
3
PU200-10 5V 3A 40A 2% N/A N/A N/A 200W PU200-12 12V 1.2A 16.7A 2% N/A N/A N/A 200W PU200-13 15V 1.0A 13.4A 2% N/A N/A N/A 200W PU200-14 24V 0.6A 8.4A 2% N/A N/A N/A 200W PU200-16 30V 0.5A 6.7A 2% N/A N/A N/A 200W PU200-18 48V 0.3A 4.2A 2% N/A N/A N/A 200W PU200-23 +5V 3A 30A 2% +12V 0A 8A 12A 4% N/A N/A 200W PU200-24 +5V 3A 30A 2% +15V 0A 6A 9A 4% N/A N/A 200W PU200-25 +5V 3A 30A 2% +24V 0A 4A 6A 4% N/A N/A 200W PU200-30 +5V 3A 30A 2% +12V 0A 8A 12A 4% -5V 0A 6A 4% N/A 200W PU200-31 +5V 3A 30A 2% +12V 0A 8A 12A 4% -12V 0A 4A 4% N/A 200W PU200-32 +5V 3A 30A 2% +15V 0A 6A 9A 4% -15V 0A 4A 4% N/A 200W PU200-40 +5V 3A 30A 2% +12V 0A 8A 12A 4% -12V 0A 4A 4% F 5V 0A 6A 4% 200W PU200-41 +5V 3A 30A 2% +15V 0A 6A 9A 4% -15V 0A 4A 4% F 24V 0A 4A 4% 200W PU200-42 +5V 3A 30A 2% +12V 0A 8A 12A 4% -12V 0A 4A 4% F 12V 0A 4A 4% 200W PU200-44 +5V 3A 30A 2% +12V 0A 8A 12A 4% -15V 0A 4A 4% F 15V 0A 4A 4% 200W PU200-45 +5V 3A 30A 2% +12V 0A 8A 12A 4% -12V 0A 4A 4% F 24V 0A 4A 4% 200W
NOTE: (1) Add suffix "B" for U-bracket or "C" for enclosed i.e. PU200-45C.
(2) Output #4 is floating. It can be connected externally for positive or negative output. (3) 200 watts for "C" version with a cover-and-fan assembly. 150 watts for "B" version without moving air (maximum current of output #1 & #2 derated to
70%), or 200 watts with 25 CFM forced air provided by user.
International Power Sources, Inc.
200 WATT
SWITCHING
POWER SUPPLY
P2 P3
777777
77
GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25°C.
Efficiency: 70% typical at 200W output Hold-up time: 20 msec minimum at 110 VAC input Line regulation: ±0.5% maximum at full load Inrush current: 60A maximum at cold start Safety ground 0.35mA max. @ 110VAC. 60Hz leakage current: 0.63mA max. @ 240VAC. 50Hz Withstand voltage: 3000 VAC from input to output
1500 VAC from input to ground
Operating temperature: 0 to 70°C* Storage temperature: -40 to +85°C Mean time between 85,000 hours at full load failure: at 25°C ambient EMI requirements: Meets conduction limits of
a) FCC 20780 Level B b) CISPR 22 (EN 55022) Level B
Safety requirements: Meets or exceeds:
a) UL 1950 b) CSA C22.2 No. 234
c) IEC 950 Power Fail Detect TTL logic high for normal operation (PFD SIGNAL) and TTL logic low upon loss of input
power. This signal appears at least
1mS prior to 5V output dropping 5%
below its nominal value. This signal
also provides a minimum delay of 100
mS after +5V is within regulation.
INPUT SPECIFICATIONS
Input voltage: 90 to 130 VAC, 180 to 264 VAC Input frequency: 47 to 440 Hz Input current: 4.5A (rms) for 115 VAC
2.6A (rms) for 230 VAC
OUTPUT SPECIFICATIONS
Output voltage: See Rating Chart Output current: See Rating Chart Output power range: See Note#3 on front of data sheet Ripple and noise: 2% peak to peak maximum Overvoltage protection: Provided on output #l only: set at
112-132% of its nominal output voltage
Overcurrent protection: All outputs protected to short
circuit conditions Temperature coefficient: All outputs ±0.04%/°C maximum Transient response: Maximum excursion of 4% or
better on all models recovering to
1% of final value within 500us after
a 25% step load change Cooling: 25 CFM forced air provided on
"C" version to be provided by user
on "B" version.
* Derate linearly from 100% load at 50°C to 50% load at 70°C
PIN CHART
MECHANICAL SPECIFICATIONS
NOTES:
1. Dimensions shown in inches [mm]
2. Tolerance 0.02 [0.5] maximum
3. Input connector P1 is Beau Inc. P/N 72-5-03C, output connector P2 is Beau Inc. P/N 72-5-09C. Screws are #6-32 on 0.375 inch centers.
4. Connector P3 mates with Molex housing 22-01-1043 and Molex 40445 series crimp terminal.
5. Weight:
1.25 Kgs (2.8 Lbs) approx. for "B" version.
1.50 Kgs (3.3 Lbs) approx. for "C" version.
Model PIN 1, 2 3, 4, 5 6 7 8 9 1 2 3 4
PU200-10, PU200-12 -SENSE RET. OUTPUT OUTPUT OUTPUT +SENSE P.F.D. COM. COM. FAN PU200-13, PU200-14 #1 #1 #1 RET. RET. PU200-16, PU200-18
PU200-23, PU200-24 OUTPUT COM. OUTPUT N.C. N.C. N. C. P.F.D. COM. COM. FAN PU200-25 #1 RET. #2 RET. RET.
PU200-30, PU200-31 OUTPUT COM. OUTPUT OUTPUT N.C. N.C. P.F.D. COM. COM. PU200-32 #1 RET. #2 #3 RET. RET. FAN
PU200-40, PU200-41 OUTPUT COM. OUTPUT OUTPUT OUTPUT OUTPUT P.F.D. COM. COM. FAN PU200-42, PU200-44 #1 RET. #2 #3 #4 #4 RET. RET. PU200-45 RETURN
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL: (508) 429-4440 FAX: (800) 226-2100
http://www.intlpower.com
International
Power Sources, Inc.
P1 1-Line 2-Neutral 3-Ground
Loading...