GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25°C.
Efficiency: 70% typical on all models
Hold-up time: 15 msec minimum at 115VAC
Line regulation: ±0.5% maximum at full load
Inrush current: 20 amps @115VAC or
40 amps @230VAC at 25°C
cold start
Withstand voltage: 3000 VAC from input to output
1500 VAC from input to ground
500 VAC from output to ground
Operating temperature: 0 to +70°C*
Storage temperature: –40 to +85°C
Relative humidity: 5% to 95% non-condensing
MTBF:
100,000 hours at full load at 25°C ambient
EMI requirements:
Meets conduction limits of
CISPR 22
Class B and FCC Class B
Safety requirements: Approved to:
a) UL1950
b) CSA C22.2 No. 234
c) IEC 950 (EN60950)
Switching frequency: 100 kHz - 130 kHz
INPUT SPECIFICATIONS
Input voltage: 85 to 132 VAC, 170 to 264 VAC
Input frequency: 47 to 63 Hz
Input current: 3.4A (rms) for 115 VAC
2.0A (rms) for 230 VAC
Leakage current: 0.4mA max at 110VAC 60 hz
0.8mA max at 240VAC 50 hz
OUTPUT SPECIFICATIONS
Output voltage: See Rating Chart
Output current: See Rating Chart
Ripple and noise: 1% peak to peak maximum
Overvoltage protection: Set at 112-132% of maximum
output voltage (on output #1 only)
Overcurrent protection: All outputs protected to short
circuit conditions
Temperature coefficient: ±0.04%/°C maximum
Transient response: Maximum excursion of 4% or
better on all models, recovering to
1% of final value 500us after a
25% step load change.
*
Derate linearly from 100% load at 50°C to 50% load at 70°C
PIN CHART
NOTES:
1. Dimensions shown in inches (mm).
2. Tolerance 0.02 (0.5) maximum.
3. Input connector P1 mates with Molex housing 09-50-3051
and Moles 2878 series crimp terminal.
4. Output connector P3 mates with Molex housing 09-50-3031 or
09-50-3091 for multiple outputs and Molex 2878 series crimp terminal.
5. Connector P4 mates with Molex housing 51110-0851 and pins 50394-8100
6. Weight: 0.84 Kgs (1.86 Lbs) approx. for “B” version
P1 P2 P3 P4
PIN
1 2 3 1 2 1 2 3 1 2 3 4 5 6 7 8
Model
PU150-10 AC AC AC Return Output Return N.C. PFD Inhibit Inhibit N.C. N.C. Return -Sense +Sense Current
Neutral Line Ground +V -Ve +Ve Share
PU150-12 PU150-13
PU150-13-1 PU150-14 AC AC AC Return Output Return N.C. N.C. Inhibit Inhibit N.C. N.C. Return -Sense +Sense Current
PU150-16 PU150-17 Neutral Line Ground +V -Ve +Ve Share
PU150-18
P1 P2 P3 P4
PIN
1 2 3 1 2 1,2 3,4,5 6 7 8 9 1 2 3 4 5 6 7 8
Model
PU150-23 PU150-24
AC AC AC Comm Output Output Comm N.C. PFD N.C. N.C. Inhibit Inhibit Fan* N.C. Comm -Sense +Sense Current
PU150-25
Neutral Line Ground Return #1 #2 Return -Ve +Ve Rtn Share
PU150-30 PU150-31
AC AC AC Comm Output Output Comm Output PFD N.C. N.C. Inhibit Inhibit Fan* N.C. Comm -Sense +Sense Current
PU150-32 PU150-33
Neutral Line Ground Return #1 #2 Return #3 -Ve +Ve Rtn Share
PU150-40 PU150-41
AC AC AC Comm Output Output Comm Output PFD Output Output Inhibit Inhibit Fan* N.C. Comm -Sense +Sense Current
PU150-42 PU150-44
Neutral Line Ground Return #1 #2 Return #3 #4 #4 Rtn -Ve +Ve Rtn Share
PU150-45
MECHANICAL SPECIFICATIONS
* Fan Voltage is equal to output #2 voltage (ex. PU150-23 has +12V fan)
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL: (508) 429-4440 FAX: (800) 226-2100
http://www.intlpower.com