Xpelair SL100, SL150, SL100P, SL150P, SL100T Installation Instructions

...
Do’s and Don’ts
Doread the entire instruction leaflet before commencing installation.Do install each fan with a means for disconnection in all poles in the fixed wiring.Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance
or cleaning.
Guarantee.
UK only: We, Applied Energy Products Ltd., provide a guarantee against faulty parts and manufacture for a period of 3 years from the date of purchase. In the unlikely event of a product breakdown during the guarantee period the product should be returned to the place of purchase or to Applied Energy Products Ltd.
Exclusions:
This guarantee does not cover compensation for the loss of the product or consequential loss of any kind.Damage or defects to the product arising from incorrect installation or lack of maintenance.Transportation costs.
This guarantee does not affect your statutory rights
Technical advice and service
Customers outside UK - see international below. United Kingdom
Xpelair have a comprehensive range of services including:
Free technical advice help-desk from Engineers on all aspects of ventilation.Free design service, quotations and site surveys.Service and maintenance contracts to suit all requirements.
Please ask for details:
By telephone on Techline: +44 (0) 844 372 7766By fax on Techfax: +44 (0) 844 372 7767At the address below
Head Office, UK Sales Office and Spares
Applied Energy Products Ltd, Morley Way, Peterborough, PE2 9JJ England Telephone: +44 (0) 844 372 7761 Fax: +44 (0) 844 372 7762 Sales/Spares Hotline: +44 (0) 844 372 7750 Sales/Spares Faxline: +44 (0) 844 372 7760 http:\\www.xpelair.co.uk
Installation and Maintenance Instructions
Xpelair SL100 / SL150 Standard Xpelair SL100P / SL150P Pull Cord Xpelair SL100T / SL150T Timer Xpelair SL100HT / SL150HT Humidistat, Timer and Pull Cord Xpelair SL100PIR / SL150PIR Integral Body Movement Sensor
Toilet / Bathroom 100mm and 150mm AC Slimline Fan Range
International.
Guarantee: Contact your local distributor or Xpelair direct for details.Technical Advice and Service: Contact your local Xpelair distributor.
Part No: 24117AA (Revision A)
A
SL100 Overall Dimensions
Setting the fan.
SL100T / SL100PIR / SL150T / SL150PIR Only.
To adjust the over-run period turn the control (T) clockwise to increase and anti-clockwise to decrease – see Figure F.
SL100HT / SL150HT Only – see figures F and G.
The pre-set humidity operation is factory set at approximately 75% Relative Humidity (RH), but can be adjusted between 65%
and 85% RH by control H.
The over -run timer can be adjusted up to 30 minutes by control T – see Figure F.Turn the controls clockwise to increase RH or time and anti-clockwise to decrease – see Figure F.
The fan can be set so that there is a 2-minute time delayed start to its operation when used with an external on/off switch. To set the time delay start to ON (fan does not start for 2 minutes) set the jumper switch to position shown in figure F. To set the time delay start to OFF (fans starts immediately) set the jumper switch to position shown in figure F.
Using the fan.
SL100 / SL150 Only
Operate the fan using the on/off switch. Repeat to switch off.
SL100P / SL150P Only
Operate the fan by pulling and releasing the cord. Repeat to switch off.
SL100T / SL150T Only
Operate the fan using an on/off switch (not supplied). When the switch is turned off, the fan continues to operate for the set
time delay. To adjust the over-run period, turn the control “T” clockwise to increase and anti-clockwise to decrease – see Figure F.
SL100HT / SL150HT Only – see Figures F and G.
Automatic mode - The fan automatically adjusts to slow changes in natural humidity levels without operating the fan. If the
humidity levels increase at a rate slower than 5% RH in 5 minutes, up to the pre-set humidity level, the fan will not be triggered
B
SL150 Overall Dimensions
by humidity. This is to prevent nuisance triggering of the fan. If humidity levels increase quicker than 5% RH in 5 minutes the fan will operate. When relative humidity drops the fan continues to operate for the adjustable time delay.
Manual mode - Use the integral pull cord switch. When the fan is switched off, it goes into automatic mode. Light flashes when
the fan is operating in manual mode.
External operation - Use the external on/off switch. When the fan is switched off, the fan continues to operate for the
adjustable time delay then goes into automatic mode. The fan can be set so that there is a 2-minute time delayed start to its operation when used with an external on/off switch.
C D
SL100PIR / SL150PIR Only
The sensor detects movement in the room and activates the fan. When movement is sensed, the fan will run for a pre-set
overrun period and any further movement sensed will re-start the sequence. This ensures that the room is only ventilated after use.
When the fan is first installed there will be a stabilising period of approximately five minutes. During this time the fan will run for up to 2 minutes.
All Fans
Re-fit the front cover by hooking in the top corners first, and then swing the cover down to fit the bottom corners. Re-fit the screw. Re-fit the electrical cover.
Cleaning (recommended once a month).
1. Before cleaning, isolate the fan completely from the mains supply.
2. Remove the front cover by removing the screw from the underside of the cover and pulling off the cover from the bottom corners first.
3. To clean the front cover, either wipe it with a damp, lint free cloth or wash it with warm soapy water. Thoroughly dry the front cover and refit.
4. Do not immerse the fan in water or other liquids to clean any other parts of the fan.
5. Do not use strong detergents, solvents or chemical cleaners
6. Allow fan to dry thoroughly before use.
7. Apart from cleaning, no other maintenance is required.