Xo Ventilation XORI36S User Manual

XORI36S
NEED HELP? Call our ventilation experts toll free al 800-966-8300 AVEZ-VOUS BESOIN D’AIDE ? Contactez nos experts au numéro gratuit 800-966-8300 ¿NECESITA AYUDA? Póngase en contacto con nuestros expertos a través del número gratis 800-966-8300
USA
F
E
RANGE HOOD - User instructions
HOTTE DE CUISINE - Notice d’utilisation
CAMPANA EXTRACTORA - Manual de utilización
XO Hood Warranty
Proof of original purchase date and invoice is needed to obtain service under warranty.
What is covered
What is not covered
Limited 2 Year Warranty.
For 2 years from the original date of purchase, we will provide, free of charge, parts and service labor in your home to repair or replace any part of the hood that fails because of a manufacturing defect.
The warranty is extended to the original purchaser for products purchased for ordinary home use in North America.
Should you require service for your XO product call a product service specialist at 800.966.8300
Improper Installation. Service trips to the home to teach you how to use the product. Resetting circuit breakers. Damage caused after delivery.
EXPECT MORE FROM XO
When buying any XO appliance you can be confident you have purchased a high quality, innovative, and stylish product, from a company who cares about you
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
FOR RESIDENTIAL USE ONLY
USA
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference.
Take care when using cleaning agents or detergents. Suitable for use in household cooking area.
WARNING - To reduce the risk of re or electric shock, do not use this fan with any
Solid-State Speed Control Device.
CAUTION - To reduce risk of re and to properly exhaust air, be sure to duct air out-
side – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
CAUTION - For general ventilating use only. Do not use to exhaust hazardous or ex-
plosive materials and vapors.
CAUTION - To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. o power unit.
CAUTION - Please read specication label on product for further information and
requirements.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer.
B. Before servicing or cleaning unit, switch power o at service panel and lock the serv-
ice disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a promi­nent warning device, such as a tag, to the service panel.
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers cause smoking and
greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
B. Always turn hood ON when cooking at high heat or when ambeing foods (i.e.
- 3 -
Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè).
C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on
fan or lter.
D. Use proper pan size. Always use cookware appropriate for the size of the surface
element.
E. Keep fan, lters and grease laden surface clean. F. Use high range setting on range only when necessary.Heat oil slowly on low to me-
dium setting.
G. Don’ t leave range unattended when cooking. H. Always use cookware and utensils appropriate for the type and amount o food be-
ing prepared.
WARNING – TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE
TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:
A. SMOTHER FLAMES with a close-tting lid, cookie sheet, or metal tray, then turn o
the burner. BE CAREFUL TO PREVENT BURNS. If the ames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
B. NEVER PICK UP A FLAMING PAN – You may be burned. C. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion
will result.
D. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate
it.
2. The re is small and contained in the area where it started.
3. The re department is being called.
4. You can ght the re with your back to an exit.
a
Based on “kitchen resafety tips” published by NFPA.
Proper maintenance of the Range Hood will assure proper performance of the
unit.
INSTALLATION INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualied person(s) in accord-
ance with all applicable codes and standards, including re-rated construction.
B. Sucient air is needed for proper combustion and exhausting of gases through the
ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heat­ing equipment manufacturer’s guideline and safety standards such as those pub­lished by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
- 4 -
D. Ducted fans must always be vented to the outdoors. E. This unit must be grounded.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
WARNING - UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE
DANGEROUS.
A. Do not check lters with hood working. B. Do not touch the lamps after a prolonged use of the appliance. C. No food must be cooked ambè underneath the hood. D. The use of an unprotected ame is dangerous for the lters and could cause res. E. Watch constantly the fried food in order to avoid the cooking oil ares up. F. Before performing any mainteinance operation, disconnect the hood from the
electrical service.
The manufacturers will not to accept any responsability for eventual damages,
because of failure to observe the above instructions.
- 5 -
DUCT FITTINGS:
This Hood Must Use an 6" Round Duct. It Can Transition to 3-1/4" x
10" or 3-1/4" x 12" Duct.
Use this chart to compu­te maximum permissible lengths for duct runs to
outdoors.
Duct Piece:
Equivalent
Dimensions:
Round, straight
3-1/4" x 10" straight
90° elbow 12 ft.
Number Length*:
1 ft. (per foot lenhgth)
1 ft. (per foot lenhgth)
Quantity Used:
Total Equivalent Length:
NOTE: Do not exceed maxi-
Installation Preparation
mum permissible equivalent lengths!
Maximum duct length: 100 feet for range ho-
ods. Flexible ducting:
If flexible metal ducting is used, all the equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as much as
possible. DO NOT use flexible plastic
ducting.
NOTE: Any home ventilation system, such as a ventilation hood, may interrupt the proper flow of combustion air and exhaust required by fireplaces, gas furnaces, gas water heaters and other naturally vented systems. To minimize the chance of in­terruption of such naturally vented systems, follow the heating equipment manu­facturer’s guidelines and safety standards such as those published by NFPA.
45° elbow 7 ft.
3-1/4" x 10" 3-1/4" x 12" 90° elbow
3-1/4" x 10" 3-1/4" x 12" 45° elbow
3-1/4" x 10" 3-1/4" x 12" 90° elbow
6" round to rectangular
Rectangular to 8" round
3-1/4" x 10" 3-1/4" x 12" 6" round to rectangular transition 90° elbow
3-1/4" x 10" 3-1/4" x 12" Rectangular to 6" transition 90° elbow
Round wall cap with dramper
3-1/4" x 10" 3-1/4" x 12" Rectangular wall cap with dramper
Round roof cap
14 ft. 10 ft.
8 ft. 6 ft.
33 ft. 24 ft.
2 ft.
2 ft.
4 ft. 4 ft.
4 ft. 4 ft.
24 ft.
24 ft. 18 ft.
33 ft.
*Actual length of straight duct plus duct fitting equivalent. Equivalent length of duct pieces reflect requirements for good venting performance with any ventilation hood.
- 6 -
Total Duct Run =
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option.
Use single wall rigid Metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints w/ certied Silver Tape or Duct Tape.
Installation - Ducting Options
INSTALL THE DUCTWORK:
NOTE: To reduce the risk of re, use only metal ductwork.
1. Decide where the ductwork will run between the hood and the outside.
2. A straight, short duct run will allow the hood to perform most eciently.
3. Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible.
4. Install a roof or wall cap. Connect 6” round metal ductwork to cap and work back towards hood location. Use duct tape to seal the joints between ductwork sections.
- 7 -
PRODUCT DIMENSIONS AND CLEARANCE XORI36S:
 Front of hood
Hood Specications
Max 42-11/16” - Min. 29-5/16"
3-1/8"
12-15/16"
 Side of hood
11-3/16"
22-11/16”
 Top of hood  Mounting height
and clearance:
23-5/8"
Min 27" - Max 32"
35-3/8"
36"
- 8 -
INSTALLATION INSTRUCTIONS INSTALLATION  VENTED TO THE OUTSIDE
1. INSTALLATION:
- Remove the structure from the packa­ging and remove the 2 screws A to sepa­ratethe upper part from the lower part (Fig.1).
- Position hole template on the ceiling paying attention that the arrow is posi­tioned on the same side as the appliance controls (Fig.2). Make 4, Ø8 holes in the ceiling and drive in 3 screws without completely tighte­ning them. Pay attention not to insert the screw into the hole marked with an X on the hole template (the screws and expan­sion plugs must be suitable for the type of wall).
- Take the upper part of the structure B (Fig.3) and insert the 3 slots onto the 3 screws that are not completely tightened. Rotate slightly to t (Fig.3). Drive in the fourth screw X and tighten the remaining 3 to allow denitive blocking of the upper part ofstructure B.
- Take the lower part of the telescopic structure C and insert it into the upper
Fig.1
A
B
X
B
Fig.3
Fig.2
B
- 9 -
structure B (Fig.4). Adjust the height by referring to the amounts indicated in (Fig.5) and block it usingthe 8 screws G that are supplied (Fig.6).
- Fix the exible pipe to the prepared air evacuation hole (Fig.7).
- Take the upper chimney piece and x it to the structure using the 2 screws A (Fig.8). Join the lower chimney piece with the upper one and x it carefully using adhesive tape L (Fig.9A).
- Unscrew the 2 screws O, max 3 mm (Fig.9A). Insert the exhaust unit inside
B
C
Fig.4
G
G
C
A
B
X
3-9/16"
25-9/16"
B
G
X = C - (3-9/16"+A+25-9/16"+B)
Fig.5 Fig.6
- 10 -
C
Fig.7 Fig.8
A
A
Max 3 mm
B
L
L
N
O
N
Fig.9
O
O
O
- 11 -
the structure paying attention that the
L
previously unscrewed screws O, hook into the slots in the lower part as indi­cated in (Fig.9B). Drive in the 3 screws
N (supplied)and tighten the 2 screws O (Fig.9B).
- Fix the air evacuation pipe H (not sup- plied) onto the connection ange F (Fig.10).
- Remove adhesive tape L and rest the lower chimney piece above the cooker hood (Fig.11).
- If the cooker hood is supplied with a lower chimney piece that must be xed
H
F
Fig.10
P
Fig.12
Fig.11
Fig.13
- 12 -
to the hood body with screws, remove the anti-grease lters from the hood by acting on the relevant handles (Fig.13). Then screw the lower chimney piece pipe to the inside of the hood, using screws P (Fig.12). Relocate the lters in their seat.
IMPORTANT - The range hood must be secured to wall studs or use drywall anchors capable of supporting 75 lbs.
- 13 -
POWER SUPPLY:
IMPORTANT – (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances.
Electrical supply:
These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.
t8JSJOHNVTUCFXJSFXJUIHSPVOE t*G UIF FMFDUSJDBM TVQQMZ EPFT OPU NFFU UIF BCPWF SFRVJSFNFOUT DBMM B MJDFOTFE
electrician before proceeding. t3PVUF IPVTFXJSJOHBTDMPTFUP UIF JOTUBMMBUJPO MPDBUJPO BTQPTTJCMFJO UIF DFJMJOH PS back wall. Refer to Wiring Locations on page 15.
t$POOFDUUIFIPPEXJSJOHUPUIFIPVTFXJSJOHJOBDDPSEBODFXJUIMPDBMDPEFT
WARNING: The improper connection of the equipment-grounding conductor can
result in a risk of electric shock. Check with a qualied electrician or service representa­tive if you are in doubt whether the appliance is properly grounded.
- 14 -
2. CONNECT ELEC TRICAL: WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PER-
SONS, OBSERVE THE FOLLOWING: Before making electrical connections to power supply, the electrical box must be secured in place as indicated in Fig.14. Before installing the appliance x the electrical box as indicated in Fig.14.
A
B
Fig.14B: Remove the 3 xed screws.Fig.14A: Lift the electrical plant box.
C
Fig.14C: Position the electrical box so it is in the line with the holes of the previously
removed screws and tighten.
- 15 -
t1PXFS4VQQMZ$POOFDUJPO
For connection to the power supply refer to the following Fig.15:
1. Remove the power supply cover by undoing the (2) screws (Fig.15A).
2. Break through the hole on the box cover.
3. Secure the power supply conduit to the cover.
4. Connect the wires of the hood to those of the power supply as described Fig.15B:
BLACK = L line WHITE = N neutral GREEN/YELLOW = G ground
- A double-pole switch properly rated must be installed to provide the range hood
power supply disconnection.
- Connect the electrical conduit to the Field Wiring Compartment using listed conduit
ttings.
- Carry out the power supplly connection in accordance with the national electric code,
A B
Fig.15
- 16 -
ANSI/NFPA 70-1999.
5. Insert the wires into the box, then close the box cover, securing it using the screws
that were previously removed. The appliance must be installed at a mini­mum height of 27" from an electric cooker stove, or 32" from gas or combined cooker stoves. If a connection ductwork composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood exhaust duct air to the same duct air used to exhaust hot air or fumes from other appliances other than electrical. Before proceeding with the assembly operations, remove the anti­grease lter(s) (Fig.16) so that the unit is easier to handle.
Fig.16
3. CONNECT THE DUCTWORK:
Min 27" - Max 32"
36"
- 17 -
DUCTLESS RECIRCULATING OPTION:
F
b
a
c
CARBON FILTER KIT XORFK01: The kit includes an air diverter A, 1 screw B and 2 rect­angular lters C.
3.1
a
3.2
E
E
Fig.1: Put together the two parts of the air de­viator as shown in picture no 3.1. It may be nec­essary to cut the deviator to fit the width of the chimney as shown in picture 3.2. A sharp blade or Hacksaw is recommended to trim the plastic.
Fig.2: To remove the two screws E, to take down the lower chi- meny F.
F
- 18 -
F
2
a
b
1
E
2
6" ROUND FLEXIBLE METAL DUCT PIPE NOT INCLUDED
Fig.3: To fix the air diverter A on the support’s
bracket using the screw B as it is shown in the figure. Once that the air diverter A has been fixed, it is necessary to connect the flexible pipe (6" ROUND FLEXIBLE METAL DUCT PIPE NOT INCLUDED).
2
1
E
Fig.4: To take the upper chimeny F and to fix it to the structure using the two screws E.
F
6" ROUND FLEXIBLE METAL DUCT PIPE
3
Fig.5: To join the lower chimney 1 with the upper one and to fix it carefully with the adhesive tape 2. To fix the flexible pipe (6"
ROUND FLEXIBLE METAL DUCT PIPE NOT INCLUDED) on the flange of connection 3.
NOT INCLUDED
- 19 -
Fig.6: Remove adhesive tape 2 and rest the lower chimney piece above the cooker hood.
2
c
1
c
Fig.7: Remove the aluminum panels by pulling the lever 1 out and pushing downwards 2.
1
1
2
Fig.8: The charcoal filters C must be fit­ted in the ducting unit located inside the hood.
2
Fig.9: Put the aluminum panels back in place (Fig.7).
- 20 -
USE
t*GUIFBQQBSBUVTJTFRVJQQFEXJUIUIF
following controls luminous: A = LIGHT B = OFF C = SPEED I D = SPEED II E = SPEED III F = AUTOMATIC STOP TIMER - 15 minutes (*)
tIf your appliance does not have the
INTENSIVE speed function, press key E for two seconds and it will be activated for 10 minutes after which it will return to the previously set speed. When the function is active the LED ashes. To interrupt it before the 10 minutes have expired press key E again.
ABCDEF
t By pressing key F for two seconds (with the hood switched o) the “clean air” function is activated. This function switches the appliance on for ten minutes every hour at the rst speed. As soon as this function is activated the motor starts up at the rst speed for ten minutes. During this time key F and key C must ash at the same time. After ten minutes the motor switches o and the LED of key F remains switched on with a xed light until the motor starts up again at the rst speed after fty minutes and keys F and C start to ash again for ten minutes and so on. By pressing any key for the exclusion of the hood light the hood will return immediately to its normal functioning (e.g. if key D is pressed the “clean air” function is deactivated and the motor moves to the 2nd speed straight away. By pressing key B the function is deactivated).
(*) The “automatic stop timer” delays stopping of the hood, which will continue func- tioning for 15 minutes at the operating speed set at the time this function is activated.
t"DUJWFDBSCPOHSFBTFöMUFSTBUVSBUJPO
- When button A ashes at a frequency of 2 seconds, the grease lters must be cleaned.
- When button A ashes at a frequency of 0.5 seconds, the carbon lters must be replaced.
After the clean lter has been replaced, the electronic memory must be reset by pressing button A for approximately 5 seconds, until the light on the button stops ashing.
- 21 -
MAINTENANCE
tWe recommend that the cooker hood is switched on before any food is cooked. We also recommend that the appliance is left running for 15 minutes after the food is cooked, in order to thoroughly eliminate all contaminated air. The eective perfor­mance of the cooker hood depends on constant maintenance; the anti-grease filter and the active carbon filter both require special attention. t5IFBOUJHSFBTF öMUFS is used to trap any grease particles suspended in the air, therefore is subject to saturation (the time it takes for the lter to become saturated depends on the way in which the appli­ance is used). The grease lters should be cleaned frequently. Use a warm detergent solution. Grease lters are a dishwasher safe.
- To prevent potential re hazards, the anti-grease lters should be washed a minimum
of every 2 months (it is possible to use the dishwasher for this task).
- After a few washes, the colour of the lters may change. This does not mean they have
to be replaced. If the replacement and washing instructions are not followed, the anti­grease lters may present a re hazard. t5IFBDUJWFDBSCPOöMUFST are used to purify the air which is released back into the room. The lters are not washable or re-usable and must be replaced at least once every four months. The active carbon lter saturation level depends on the frequency with which the appliance is used, the type of cooking performed and the regularity with which the anti-grease lters are cleaned.
t$MFBOUIFDPPLFSIPPEGSFRVFOUMZCPUIJOTJEFBOEPVUTJEFVTJOHBDMPUIXIJDIIBTCFFO
dampened with denatured alcohol or neutral, non-abrasive liquid detergents.
t5IFMJHIUPOUIFDPPLFSIPPEJTEFTJHOFEGPSVTFEVSJOHDPPLJOHBOEOPUGPSHFOFSBM
room illumination. Extended use of the light reduces the average duration of the bulb.
t)PPE$MFBOJOH
Stainless steel is one of the easiest materilas to keep clean. Occasional care will help preserve its ne appearance. Cleaning tips:
- Hot water with soap or detergent is all that is usually needed.
- Follow all cleaningby rising with clear water. Wipe dry with a clean, soft cloth to avoid
water marks.
- For discolorations or deposit that persist, use a non-scratching household cleanser or
stainless steel polishing powder with a little water and a soft cloth.
- For stubborn cases, use a plastic scouring pad or soft bristle brush together with cleaser
and water. Rub lightly in direction of polishing lines or “grain” of the stainless finish. Avoid using too much pressure wich may mar the surface.
- 22 -
- DO NOT allow deposit to remain for long periods of time.
- DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the
surface causing rust.
- DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain
in contact with stainless steel for extended periods. Many of these compounds contain chemicals with may be harmful. Rinse with water after exposure and wipe dry with a clean cloth. Painted surfaces should be cleaned with warm water and mild detergent only.
- 23 -
t Replacing halogen light bulbs: To replace the halogen light bulbs B, remove the glass panel C using a lever action on the relevant cracks. Replace the bulbs with new ones of the same type. Caution: do not touch the light bulb with bare hands.
B
C
- 24 -
XORI36S:
171
173
20
10
30
230
469
100
29
261
39
110
70
160
40
609
- 25 -
140
241
554
120
OPTIONS AND ACCESSORIES:
Model XORFK01 - Ductless Recirculating Filter Kit.
- 26 -
Loading...
+ 58 hidden pages