NEED HELP?
Call our ventilation experts toll free al 800-966-8300
AVEZ-VOUS BESOIN D’AIDE?
Contactez nos experts au numéro gratuit 800-966-8300
¿NECESITA AYUDA?
Póngase en contacto con nuestros expertos a través del número gratis 800-966-8300
USA
F
E
RANGE HOOD - User instructions
HOTTE DE CUISINE - Notice d’utilisation
CAMPANA EXTRACTORA - Manual de utilización
XO Hood Warranty
Proof of original purchase date and invoice is needed to obtain
service under warranty.
What is covered
What is not covered
Limited 2 Year Warranty.
For 2 years from the original date of purchase, we will provide,
free of charge, parts and service labor in your home to repair or
replace any part of the hood that fails because of a manufacturing
defect.
The warranty is extended to the original purchaser for products
purchased for ordinary home use in North America.
Should you require service for your XO product call a product
service specialist at 800.966.8300
Improper Installation.
Service trips to the home to teach you how to use the product.
Resetting circuit breakers.
Damage caused after delivery.
EXPECT MORE FROM XO
When buying any XO appliance
you can be confident
you have purchased a high quality,
innovative, and stylish product,
from a company who cares about you
- 2 -
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
FOR RESIDENTIAL USE ONLY
USA
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.IMPORTANT: Save these Instructions for the Local Electrical Inspectors use.INSTALLER: Please leave these Instructions with this unit for the owner.OWNER: Please retain these instructions for future reference.
Take care when using cleaning agents or detergents.
Suitable for use in household cooking area.
WARNING - To reduce the risk of re or electric shock, do not use this fan with any
Solid-State Speed Control Device.
CAUTION - To reduce risk of re and to properly exhaust air, be sure to duct air out-
side – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl
spaces, or garages.
CAUTION - For general ventilating use only. Do not use to exhaust hazardous or ex-
plosive materials and vapors.
CAUTION - To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. o power unit.
CAUTION - Please read specication label on product for further information and
requirements.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer.
B. Before servicing or cleaning unit, switch power o at service panel and lock the serv-
ice disconnecting means to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers cause smoking and
greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
B. Always turn hood ON when cooking at high heat or when ambeing foods (i.e.
C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on
fan or lter.
D. Use proper pan size. Always use cookware appropriate for the size of the surface
element.
E. Keep fan, lters and grease laden surface clean.
F. Use high range setting on range only when necessary.Heat oil slowly on low to me-
dium setting.
G. Don’ t leave range unattended when cooking.
H. Always use cookware and utensils appropriate for the type and amount o food be-
ing prepared.
WARNING – TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE
TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:
A. SMOTHER FLAMES with a close-tting lid, cookie sheet, or metal tray, then turn o
the burner. BE CAREFUL TO PREVENT BURNS. If the ames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
B. NEVER PICK UP A FLAMING PAN – You may be burned.
C. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion
will result.
D. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate
it.
2. The re is small and contained in the area where it started.
3. The re department is being called.
4. You can ght the re with your back to an exit.
a
Based on “kitchen resafety tips” published by NFPA.
Proper maintenance of the Range Hood will assure proper performance of the
unit.
INSTALLATION INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualied person(s) in accord-
ance with all applicable codes and standards, including re-rated construction.
B. Sucient air is needed for proper combustion and exhausting of gases through the
ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
- 4 -
D. Ducted fans must always be vented to the outdoors.
E. This unit must be grounded.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
WARNING - UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE
DANGEROUS.
A. Do not check lters with hood working.
B. Do not touch the lamps after a prolonged use of the appliance.
C. No food must be cooked ambè underneath the hood.
D. The use of an unprotected ame is dangerous for the lters and could cause res.
E. Watch constantly the fried food in order to avoid the cooking oil ares up.
F. Before performing any mainteinance operation, disconnect the hood from the
electrical service.
The manufacturers will not to accept any responsability for eventual damages,
because of failure to observe the above instructions.
- 5 -
DUCT FITTINGS:
This Hood Must Use an
6" Round Duct. It Can
Transition to 3-1/4" x
10" or 3-1/4" x 12" Duct.
Use this chart to compute maximum permissible
lengths for duct runs to
outdoors.
Duct
Piece:
Equivalent
Dimensions:
Round, straight
3-1/4" x 10"
straight
90° elbow12 ft.
Number
Length*:
1 ft. (per foot
lenhgth)
1 ft. (per foot
lenhgth)
Quantity
Used:
Total
Equivalent
Length:
NOTE: Do not exceed maxi-
Installation Preparation
mum permissible equivalent
lengths!
Maximum duct length:
100 feet for range ho-
ods.
Flexible ducting:
If flexible metal ducting
is used, all the equivalent
feet values in the table
should be doubled. The
flexible metal duct should
be straight and smooth
and extended as much as
possible.
DO NOT use flexible plastic
ducting.
NOTE: Any home ventilation
system, such as a ventilation
hood, may interrupt the
proper flow of combustion
air and exhaust required
by fireplaces, gas furnaces,
gas water heaters and other
naturally vented systems. To
minimize the chance of interruption of such naturally
vented systems, follow the
heating equipment manufacturer’s guidelines and
safety standards such as
those published by NFPA.
45° elbow7 ft.
3-1/4" x 10"
3-1/4" x 12"
90° elbow
3-1/4" x 10"
3-1/4" x 12"
45° elbow
3-1/4" x 10"
3-1/4" x 12"
90° elbow
6" round to
rectangular
Rectangular to
8" round
3-1/4" x 10"
3-1/4" x 12"
6" round to
rectangular
transition 90°
elbow
3-1/4" x 10"
3-1/4" x 12"
Rectangular to
6" transition
90° elbow
Round wall
cap with
dramper
3-1/4" x 10"
3-1/4" x 12"
Rectangular
wall cap with
dramper
Round roof
cap
14 ft.
10 ft.
8 ft.
6 ft.
33 ft.
24 ft.
2 ft.
2 ft.
4 ft.
4 ft.
4 ft.
4 ft.
24 ft.
24 ft.
18 ft.
33 ft.
*Actual length of straight duct plus duct
fitting equivalent. Equivalent length of duct
pieces reflect requirements for good venting
performance with any ventilation hood.
- 6 -
Total Duct Run =
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces,
ceiling, attics or garages.
All exhaust must be ducted to the outside, unless using the recirculating option.
Use single wall rigid Metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints w/ certied Silver
Tape or Duct Tape.
Installation - Ducting Options
INSTALL THE DUCTWORK:
NOTE: To reduce the risk of re, use only metal ductwork.
1. Decide where the ductwork will run between the hood and the outside.
2. A straight, short duct run will allow the hood to perform most eciently.
3. Long duct runs, elbows, and transitions will reduce the performance of the
hood. Use as few of them as possible.
4.XOI3315S - XOI3315SMUA: Install a roof or wall cap.
Connect 6" round metal ductwork to cap and work back towards hood location.
Use duct tape to seal the joints between ductwork sections.
5.XOI3315KS - XOI4515KS: Install a roof or wall cap. Connect 8" round metal ductwork
to cap and work back towards hood location. Use duct tape to seal the joints
between ductwork sections.
- 7 -
PRODUCT DIMENSIONS AND CLEARANCE
XOI3315S - XOI3315SMUA:
Front of hood
Hood Specications
32-3/8" - 44-3/8"
24-1/2"
33-3/4"
1-1/4"
Side of hood
Ø 6"
15/16"
11-1/2"
1-3/16"
12-5/8"
15"
Top of hood Mounting height
1-1/16"
2-1/16"2-1/16"
4-1/4"4-1/4"
and clearance:
Min 27" - Max 32"
36"
Fig.1A
- 8 -
PRODUCT DIMENSIONS AND CLEARANCE
XOI3315KS - XOI4515KS:
Front of hood
32-3/8" - 44-3/8"
24-1/2" - 36-1/2"
33-3/4" - 45-3/4"
1-1/4"
11-1/2"
Side of hood
Ø 7-7/8"
3-17/32"
1-3/16"
12-5/8"
15"
4-7/8"
Hood Specications
Top of hood Mounting height
and clearance:
1-1/16"
2-1/16"2-1/16"
4-1/4"4-1/4"
Min 27" - Max 32"
36"
Fig.1B
- 9 -
INSTALLATION INSTRUCTIONS
INSTALLATION VENTED TO THE OUTSIDE
1. INSTALLATION:
This product can be installed in 2 dierent ways:
1) Fixing of the hood with wood framework
(Fig.3).
2) Fixing of the hood in the lower part of the
kitchen cabinet (Fig.4-5-6-7).
t'JYJOHPGUIFIPPEXJUIXPPEGSBNFXPSL
When tting the hood use screws that are suitable
for the type of cabinet to which the appliance is
being xed, following the corresponding holes as
shown in gure 1A - gure 1B respecting the measurements indicated.
When xing the hood in place make sure a wooden
frame (not supplied) is tted inside the cabinet, as
gure 2 and fully
16-3/8"
Fig.2
13-1/32"
32-1/2" or
32-1/2" or
44-1/2"
44-1/2"
Fig.2
- 10 -
shown in gure 3.
B
1 9/16" min
1-9/16" min
Fix the appliance in place using the 6 screws P (Fig.3) and then t the two safety screws
D (Fig.3).
IMPORTANT - The range hood must be secured to wall studs or use drywall
anchors capable of supporting 75 lbs.
For all measurements relating to the cooker hood, please refer to Fig.2.
Before xing the cooker hood to the lower part of the cabinet, the following steps should
be performed:
1. Remove the 4 screws E xing the two cooker hood brackets H (RHS and LHS) in place
as indicated in Fig.4A.
2. Remove the brackets H as shown in Fig.4B.
3. Make sure the thickness of the cabinet falls within the range of values listed in
Fig.4C.
Fit the cooker hood in the cabinet (Fig.8) and make sure the 4 springs are xed in place
well. Fix the cooker hood to the cabinet securely by using a screwdriver to tighten the
screws M until the appliance is ush with the cabinet (Fig.5). Place again the 2 brackets H (right and left) of the hood and x them with the 4 screws E (Fig.6 - Fig.7).
When installed in this way the appliance discharges fumes outside, either through a
perimeter wall or existing ducting.It is therefore necessary to purchase a non-ammable
air exhaust tube A (not supplied) which complies with all current legislation and connect
it to ange B (Fig.3).
B
B
E
H
B
F
F
Min - 0-1/2"
Max - 1-0/16"
E
A
D
Fig.4
E
C
- 12 -
H
M
F
Fig.5
E
Fig.6
E
Fig.7
- 13 -
POWER SUPPLY:
IMPORTANT – (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before beginning installation. Do not use an
extension cord or adapter plug with this appliance. Follow National electrical codes or
prevailing local codes and ordinances.
Electrical supply:
These vent hoods must be supplied with 120V, 60Hz, and connected to an individual,
properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or
time delay fuse.
WARNING: The improper connection of the equipment-grounding conductor can
result in a risk of electric shock. Check with a qualied electrician or service representative
if you are in doubt whether the appliance is properly grounded.
- 14 -
2. CONNECT ELEC TRICAL:
tPower Supply Connection
For connection to the power supply refer to the follows Fig.3-Fig.8:
BLACK = L line
WHITE = N neutral
GREEN/YELLOW = G ground.
- A double-pole switch properly rated must be installed to provide the range hood
power supply disconnection.
- Connect the electrical conduit to the Field Wiring Compartment using listed conduit
ttings.
- Carry out the power supplly connection in accordance with the national electric code,
ANSI/NFPA 70-1999.
5. Insert the wires into the box, then close the box cover, securing it using the screws
that were previously removed.
The appliance must be installed at a minimum height of 27" from an electric cooker stove,
or 32" from gas or combined cooker stoves. If a connection ductwork composed of two
Fig.8Fig.9
- 15 -
parts is used, the upper part must be placed outside the lower part. Do not connect the
range hood exhaust duct air to the same duct air used to exhaust hot air or fumes from
other appliances other than electrical. Before proceeding with the assembly operations,
remove the anti-grease lter(s) (Fig.9) so that the unit is easier to handle.
3. CONNECT
THE DUCTWORK:
Min 27" - Max 32"
36"
- 16 -
USE
t*G UIF BQQBSBUVT JT FRVJQQFE XJUI UIF
following controls:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
G = MOTOR WORKING indicator.
G
B
C
D
E
A
- 17 -
MAINTENANCE
tWe recommend that the cooker hood is
switched on before any food is cooked.
We also recommend that the appliance
is left running for 15 minutes after the
food is cooked, in order to thoroughly
eliminate all contaminated air. The eective
performance of the cooker hood depends
on constant maintenance; the anti-grease
filter and the active carbon filter both
require special attention.
t5IFBOUJHSFBTFGJMUFS is used to trap
any grease particles suspended in the air,
therefore is subject to saturation (the time
it takes for the lter to become saturated
depends on the way in which the appliance
is used). The grease lters should be cleaned
frequently. Use a warm detergent solution. Grease lters are a dishwasher safe.
- To prevent potential re hazards, the anti-grease lters should be washed a minimum
of every 2 months (it is possible to use the dishwasher for this task).
- After a few washes, the colour of the lters may change. This does not mean they have
to be replaced. If the replacement and washing instructions are not followed, the antigrease lters may present a re hazard.
t5IFBDUJWFDBSCPOöMUFST are used to purify the air which is released back into the room.
The lters are not washable or re-usable and must be replaced at least once every four
months. The active carbon lter saturation level depends on the frequency with which
the appliance is used, the type of cooking performed and the regularity with which the
anti-grease lters are cleaned.
tClean the cooker hood frequently, both inside and outside, using a cloth which has been
dampened with denatured alcohol or neutral, non-abrasive liquid detergents.
tThe light on the cooker hood is designed for use during cooking and not for general
room illumination. Extended use of the light reduces the average duration of the bulb.
t)PPE$MFBOJOH
Stainless steel is one of the easiest materilas to keep clean. Occasional care will help
preserve its ne appearance.
Cleaning tips:
- Hot water with soap or detergent is all that is usually needed.
- Follow all cleaningby rising with clear water. Wipe dry with a clean, soft cloth to avoid
water marks.
- For discolorations or deposit that persist, use a non-scratching household cleanser or
stainless steel polishing powder with a little water and a soft cloth.
- For stubborn cases, use a plastic scouring pad or soft bristle brush together with cleaser
and water. Rub lightly in direction of polishing lines or “grain” of the stainless finish. Avoid
using too much pressure wich may mar the surface.
- DO NOT allow deposit to remain for long periods of time.
- 18 -
- DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the
surface causing rust.
- DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain
in contact with stainless steel for extended periods. Many of these compounds contain
chemicals with may be harmful. Rinse with water after exposure and wipe dry with a clean
cloth.
Painted surfaces should be cleaned with warm water and mild detergent only.
- 19 -
t3FQMBDJOHIBMPHFOMJHIUCVMCT
To replace the dichroic lamps, rotate the
lamp anticlockwise by means of a suction
cup as shown in Figure.
Replace the bulbs with new ones of the
same type.
- 20 -
XOI3315S - XOI3315SMUA:
173173
145
110
100
120
261
39
12
29
609
492
- 21 -
70
40
140