XICOR X1227V8I-4.5A, X1227V8I-2.7A, X1227V8I-2.7, X1227V8-4.5A, X1227V8-2.7A Datasheet

...
New Features
Repetitive Alarms & Temperature Compensation
Real Time Clock/Calendar/CPU Supervisor with EEPROM
FEATURES
• Real Time Clock/Calendar — Tracks time in Hours, Minutes, and Seconds — Day of the Week, Day, Month, and Year
• 2 Polled Alarms (Non-volatile) — Settable on the Second, Minute, Hour, Day of the
Week, Day, or Month
— Repeat Mode (periodic interrupts)
• Oscillator Compensation on chip — Internal feedback resistor and compensation
capacitors — 64 position Digitally Controlled Trim Capacitor — 6 digital frequency adjustment settings to ±30ppm
• CPU Supervisor Functions — Power On Reset, Low Voltage Sense — Watchdog Timer (SW Selectable: 0.25s, 0.75s,
1.75s, off)
• Battery Switch or Super Cap Input
• 4K x 8 Bits of EEPROM — 64-Byte Page Write Mode — 8 modes of Block Lock™ Protection — Single Byte Write Capability
• High Reliability — Data Retention: 100 years — Endurance: 100,000 cycles per byte
• 2-Wire™ Interface interoperable with I2C* — 400kHz data transfer rate
• Low Power CMOS — 1.25µA Operating Current (Typical)
• Small Package Options — 8-Lead SOIC and 8-Lead TSSOP
X1227
APPLICATIONS
• Utility Meters
• HVAC Equipment
• Audio / Video Components
• Set Top Box / Television
• Modems
• Network Routers, Hubs, Switches, Bridges
• Cellular Infrastructure Equipment
• Fixed Broadband Wireless Equipment
• Pagers / PDA
• POS Equipment
• Test Meters / Fixtures
• Office Automation (Copiers, Fax)
• Home Appliances
• Computer Products
• Other Industrial / Medical / Automotive
DESCRIPTION
The X1227 device is a Real Time Clock with clock/ calendar, two polled alarms with integrated 512x8 EEPROM, oscillator compensation, CPU Supervisor (POR/LVS and WDT) and battery backup switch.
The oscillator uses an external, low-cost 32.768kHz crystal. All compensation and trim components are integrated on the chip. This eliminates several external discrete components and a trim capacitor, saving board area and component cost.
2-Wire
RTC
BLOCK DIAGRAM
Serial
X1
X2
Control
Decode
8
32.768kHz
SCL
SDA
*I2C is a Trademark of Philips.
REV 1.1.20 1/13/03
Interface Decoder
RESET
Logic
Compensation
Oscillator
Control/
Registers
(EEPROM)
OSC
Watchdog
Timer
Frequency
Divider
Registers
(SRAM)
1Hz
Status
Low Voltage
Reset
www.xicor.com
Timer
Calendar
Logic
Alarm
Time
Keeping
Registers
(SRAM)
Compare
Alarm Regs
(EEPROM)
Mask
4K
EEPROM
ARRAY
Characteristics subject to change without notice.
Battery
Switch
Circuitry
V
V
CC
BACK
1 of 28
X1227
DESCRIPTION (continued)
The Real-Time Clock keeps track of time with separate registers for Hours, Minutes, Seconds. The Calendar has separate registers for Date, Month, Year and Day­of-week. The calendar is correct through 2099, with automatic leap year correction.
The powerful Dual Alarms can be set to any Clock/ Calendar value for a match. For instance, every minute, every Tuesday, or 5:23 AM on March 21. The alarms can be polled in the Status Register. There is a repeat mode for the alarms allowing a periodic interrupt.
The X1227 device integrates CPU Supervisor func­tions and a Battery Switch. There is a Power-On Reset (RESET output) with typically 250 ms delay from power on. It will also assert RESET when Vcc goes below the specified threshold. The V
threshold is user repro-
trip
grammable. There is a WatchDog Timer (WDT) with 3 selectable time-out periods (0.25s, 0.75s, 1.75s) and a disabled setting. The watchdog activates the RESET pin when it expires.
The device offers a backup power input pin. This V
pin allows the device to be backed up by battery
BACK
or SuperCap. The entire X1227 device is fully operational from 2.7 to 5.5 volts and the clock/calendar portion of the X1227 device remains fully operational down to 1.8 volts (Standby Mode).
The X1227 device provides 4K bits of EEPROM with 8 modes of BlockLock™ control. The BlockLock allows a safe, secure memory for critical user and configuration data, while allowing a large user storage area.
PIN DESCRIPTIONS
X1227
8-Pin SOIC
RESET
V
X1
X2
SS
1 2
3
4
V
8
CC
V
7
BACK
SCL
6
SDA
5
Serial Clock (SCL)
The SCL input is used to clock all data into and out of the device. The input buffer on this pin is always active (not gated).
Serial Data (SDA)
SDA is a bidirectional pin used to transfer data into and out of the device. It has an open drain output and may be wire ORed with other open drain or open collector outputs. The input buffer is always active (not gated).
An open drain output requires the use of a pull-up resistor. The output circuitry controls the fall time of the output signal with the use of a slope controlled pull­down. The circuit is designed for 400kHz 2-wire inter­face speeds.
V
BACK
This input provides a backup supply voltage to the device. V event the V
supplies power to the device in the
BACK
supply fails. This pin can be connected
CC
to a battery, a Supercap or tied to ground if not used.
RESET Output – RESET
This is a reset signal output. This signal notifies a host processor that the watchdog time period has expired or that the voltage has dropped below a fixed V
TRIP
thresh­old. It is an open drain active LOW output. Recom­mended value for the pullup resistor is 5K Ohms. If unused, tie to ground.
X1, X2
The X1 and X2 pins are the input and output, respectively, of an inverting amplifier. An external
32.768kHz quartz crystal is used with the X1227 to supply a timebase for the real time clock. The recommended crystal is a Citizen CFS206-32.768KDZF. Internal compensation circuitry is included to form a complete oscillator circuit. Care should be taken in the placement of the crystal and the layout of the circuit. Plenty of ground plane around the device and short traces to X1 and X2 are highly recommended. See Application section for more recommendations.
V
BACK
V
CC
X1 X2
NC = No internal connection
REV 1.1.20 1/13/03
X1227
8-Pin TSSOP
1
8
2
7
3
6
4
5
SCL
SDA V
SS
RESET
Figure 1. Recommended Crystal connection
www.xicor.com
X1 X2
Characteristics subject to change without notice.
2 of 28
X1227
.
POWER CONTROL OPERATION
The power control circuit accepts a V
and a V
CC
BACK
input. The power control circuit powers the device from V
when V
BACK
power the device from V
CC
< V
- 0.2V. It will switch back to
BACK
CC
when V
exceeds V
CC
BACK
Figure 2. Power Control
V
V
CC
BACK
Off
Voltage
On
In
REAL TIME CLOCK OPERATION
The Real Time Clock (RTC) uses an external
32.768kHz quartz crystal to maintain an accurate internal representation of the second, minute, hour, day, date, month, and year. The RTC has leap-year correction. The clock also corrects for months having fewer than 31 days and has a bit that controls 24 hour or AM/PM format. When the X1227 powers up after the loss of both V
CC
and V
, the clock will not
BACK
operate until at least one byte is written to the clock register.
Reading the Real Time Clock
The RTC is read by initiating a Read command and specifying the address corresponding to the register of the Real Time Clock. The RTC Registers can then be read in a Sequential Read Mode. Since the clock runs continuously and a read takes a finite amount of time, there is the possibility that the clock could change during the course of a read operation. In this device, the time is latched by the read command (falling edge of the clock on the ACK bit prior to RTC data output) into a separate latch to avoid time changes during the read operation. The clock continues to run. Alarms occurring during a read are unaffected by the read operation.
Writing to the Real Time Clock
The time and date may be set by writing to the RTC registers. To avoid changing the current time by an uncompleted write operation, the current time value is loaded into a separate buffer at the falling edge of the clock on the ACK bit before the RTC data input bytes, the clock continues to run. The new serial input data replaces the values in the buffer. This new RTC value is loaded back into the RTC Register by a stop bit at the end of a valid write sequence. An invalid write operation aborts the time update procedure and the
contents of the buffer are discarded. After a valid write operation the RTC will reflect the newly loaded data beginning with the next “one second” clock cycle after the stop bit is written. The RTC continues to update the time while an RTC register write is in progress and the RTC continues to run during any nonvolatile write sequences. A single byte may be written to the RTC without affecting the other bytes.
Accuracy of the Real Time Clock
The accuracy of the Real Time Clock depends on the frequency of the quartz crystal that is used as the time base for the RTC. Since the resonant frequency of a crystal is temperature dependent, the RTC perfor­mance will also be dependent upon temperature. The frequency deviation of the crystal is a fuction of the turnover temperature of the crystal from the crystal’s nominal frequency. For example, a >20ppm frequency deviation translates into an accuracy of >1 minute per month. These parameters are available from the crystal manufacturer. Xicor’s RTC family provides on­chip crystal compensation networks to adjust load­capacitance to tune oscillator frequency from +116 ppm to –37 ppm when using a 12.5 pF load crystal. For more detail information see the Application section.
CLOCK/CONTROL REGISTERS (CCR)
The Control/Clock Registers are located in an area separate from the EEPROM array and are only accessible following a slave byte of “1101111x” and reads or writes to addresses [0000h:003Fh]. The clock/control memory map has memory addresses from 0000h to 003Fh. The defined addresses are described in the Table 1. Writing to and reading from the undefined addresses are not recommended.
CCR access
The contents of the CCR can be modified by perform­ing a byte or a page write operation directly to any address in the CCR. Prior to writing to the CCR (except the status register), however, the WEL and RWEL bits must be set using a two step process (See section “Writing to the Clock/Control Registers.”)
The CCR is divided into 5 sections. These are:
1. Alarm 0 (8 bytes; non-volatile)
2. Alarm 1 (8 bytes; non-volatile)
3. Control (4 bytes; non-volatile)
4. Real Time Clock (8 bytes; volatile)
5. Status (1 byte; volatile)
REV 1.1.20 1/13/03
www.xicor.com
Characteristics subject to change without notice.
3 of 28
X1227
Each register is read and written through buffers. The non-volatile portion (or the counter portion of the RTC) is updated only if RWEL is set and only after a valid write operation and stop bit. A sequential read or page write operation provides access to the contents of only one section of the CCR per operation. Access to another sec­tion requires a new operation. Continued reads or writes, once reaching the end of a section, will wrap around to
change the time being read. A sequential read of the CCR will not result in the output of data from the mem­ory array. At the end of a read, the master supplies a stop condition to end the operation and free the bus. After a read of the CCR, the address remains at the previous address +1 so the user can execute a current address read of the CCR and continue reading the
next Register. the start of the section. A read or write can begin at any address in the CCR.
It is not necessary to set the RWEL bit prior to writing the status register. Section 5 supports a single byte read or write only. Continued reads or writes from this section terminates the operation.
The state of the CCR can be read by performing a ran­dom read at any address in the CCR at any time. This returns the contents of that register location. Addi­tional registers are read by performing a sequential read. The read instruction latches all Clock registers into a buffer, so an update of the clock does not
ALARM REGISTERS
There are two alarm registers whose contents mimic the
contents of the RTC register, but add enable bits and
exclude the 24 hour time selection bit. The enable bits
specify which registers to use in the comparison between
the Alarm and Real Time Registers. For example:
– Setting the Enable Month bit (EMOn*) bit in combi-
nation with other enable bits and a specific alarm time, the user can establish an alarm that triggers at the same time once a year.
– *n = 0 for Alarm 0: N = 1 for Alarm 1
Table 1. Clock/Control Memory Map
Addr. Type
003F Status SR BAT AL1 AL0 0 0 RWEL WEL RTCF 01h 0037 RTC 0036 DW 0 0 0 0 0 DY2 DY1 DY0 0-6 00h 0035 YR Y23 Y22 Y21 Y20 Y13 Y12 Y11 Y10 0-99 00h 0034 MO 0 0 0 G20 G13 G12 G11 G10 1-12 00h 0033 DT 0 0 D21 D20 D13 D12 D11 D10 1-31 00h 0032 HR MIL 0 H21 H20 H13 H12 H11 H10 0-23 00h 0031 MN 0 M22 M21 M20 M13 M12 M11 M10 0-59 00h 0030 SC 0 S22 S21 S20 S13 S12 S11 S10 0-59 00h 0013 Control 0012 ATR 0 0 ATR5 ATR4 ATR3 ATR2 ATR1 ATR0 00h 0011 INT Unused 0010 BL BP2 BP1 BP0 WD1 WD0 0 0 0 00h 000F Alarm1
000E DWA1 EDW1 0 0 0 0 DY2 DY1 DY0 0-6 00h 000D YRA1 Unused - Default = RTC Year value (No EEPROM) - Future expansion 000C MOA1 EMO1 0 0 A1G20 A1G13 A1G12 A1G11 A1G10 1-12 00h
000B DTA1 EDT1 0 A1D21 A1D20 A1D13 A1D12 A1D11 A1D10 1-31 00h
000A HRA1 EHR1 0 A1H21 A1H20 A1H13 A1H12 A1H11 A1H10 0-23 00h
0009 MNA1 EMN1 A1M22 A1M21 A1M20 A1M13 A1M12 A1M11 A1M10 0-59 00h
0008 SCA1 ESC1 A1S22 A1S21 A1S20 A1S13 A1S12 A1S11 A1S10 0-59 00h
0007 Alarm0
0006 DWA0 EDW0 0 0 0 0 DY2 DY1 DY0 0-6 00h
0005 YRA0 Unused - Default = RTC Year value (No EEPROM) - Future expansion
0004 MOA0 EMO0 0 0 A0G20 A0G13 A0G12 A0G11 A0G10 1-12 00h
0003 DTA0 EDT0 0 A0D21 A0D20 A0D13 A0D12 A0D11 A0D10 1-31 00h
0002 HRA0 EHR0 0 A0H21 A0H20 A0H13 A0H12 A0H11 A0H10 0-23 00h
0001 MNA0 EMN0 A0M22 A0M21 A0M20 A0M13 A0M12 A0M11 A0M10 0-59 00h
0000 SCA0 ESC0 A0S22 A0S21 A0S20 A0S13 A0S12 A0S11 A0S10 0-59 00h
(SRAM)
(EEPROM)
(EEPROM)
(EEPROM)
Reg
Name
Y2K 0 0 Y2K21 Y2K20 Y2K13 0 0 Y2K10 19/20 20h
DTR 0 0 0 0 0 DTR2 DTR1 DTR0 00h
Y2K1 0 0 A1Y2K21 A1Y2K20 A1Y2K13 0 0 A1Y2K10 19/20 20h
Y2K0 0 0 A0Y2K21 A0Y2K20 A0Y2K13 0 0 A0Y2K10 19/20 20h
76543210 (optional)
Bit
Range
Default
REV 1.1.20 1/13/03
www.xicor.com
Characteristics subject to change without notice.
4 of 28
X1227
When there is a match, an alarm flag is set. The occur­rence of an alarm can be determined by polling the AL0 and AL1 bits or by enabling the IRQ output, using it as hardware flag.
The alarm enable bits are located in the MSB of the particular register. When all enable bits are set to ‘0’, there are no alarms.
– The user can set the X1227 to alarm every Wednes-
day at 8:00 AM by setting the EDWn*, the EHRn* and EMNn* enable bits to ‘1’ and setting the DWAn*, HRAn* and MNAn* Alarm registers to 8:00 AM Wednesday.
– A daily alarm for 9:30PM results when the EHRn*
and EMNn* enable bits are set to ‘1’ and the HRAn* and MNAn* registers are set to 9:30 PM.
*n = 0 for Alarm 0: N = 1 for Alarm 1
REAL TIME CLOCK REGISTERS
Clock/Calendar Registers (SC, MN, HR, DT, MO, YR)
These registers depict BCD representations of the time. As such, SC (Seconds) and MN (Minutes) range from 00 to 59, HR (Hour) is 1 to 12 with an AM or PM indicator (H21 bit) or 0 to 23 (with MIL=1), DT (Date) is 1 to 31, MO (Month) is 1 to 12, YR (Year) is 0 to 99.
Date of the Week Register (DW)
This register provides a Day of the Week status and uses three bits DY2 to DY0 to represent the seven days of the week. The counter advances in the cycle 0-1-2-3-4-5-6-0-1-2-… The assignment of a numerical value to a specific day of the week is arbitrary and may be decided by the system software designer. The default value is defined as ‘0’.
24 Hour Time
If the MIL bit of the HR register is 1, the RTC uses a 24-hour format. If the MIL bit is 0, the RTC uses a 12­hour format and H21 bit functions as an AM/PM indi­cator with a ‘1’ representing PM. The clock defaults to standard time with H21=0.
Leap Years
Leap years add the day February 29 and are defined as those years that are divisible by 4. Years divisible by 100 are not leap years, unless they are also divisible by 400. This means that the year 2000 is a leap year, the year 2100 is not. The X1227 does not correct for the leap year in the year 2100.
REV 1.1.20 1/13/03
www.xicor.com
STATUS REGISTER (SR)
The Status Register is located in the CCR Memory Map at address 003Fh. This is a volatile register only and is used to control the WEL and RWEL write enable latches, read two power status and two alarm bits. This register is separate from both the array and the Clock/Control Registers (CCR).
Table 2. Status Register (SR)
Addr 7 6 5 4 3 2 1 0
003Fh BAT AL1 AL0 0 0 RWEL WEL RTCF
Default 0 0 0 0 0 0 0 1
BAT: Battery Supply—Volatile
This bit set to “1” indicates that the device is operating from V
BACK
, not V
. It is a read-only bit and is set/
CC
reset by hardware (X1227 internally). Once the device begins operating from V
, the device sets this bit to
CC
“0”.
AL1, AL0: Alarm bits—Volatile
These bits announce if either alarm 0 or alarm 1 match the real time clock. If there is a match, the respective bit is set to ‘1’. The falling edge of the last data bit in a SR Read operation resets the flags. Note: Only the AL bits that are set when an SR read starts will be reset. An alarm bit that is set by an alarm occurring during an SR read operation will remain set after the read opera­tion is complete.
RWEL: Register Write Enable Latch—Volatile
This bit is a volatile latch that powers up in the LOW (disabled) state. The RWEL bit must be set to “1” prior to any writes to the Clock/Control Registers. Writes to RWEL bit do not cause a nonvolatile write cycle, so the device is ready for the next operation immediately after the stop condition. A write to the CCR requires both the RWEL and WEL bits to be set in a specific sequence.
WEL: Write Enable Latch—Volatile
The WEL bit controls the access to the CCR and memory array during a write operation. This bit is a volatile latch that powers up in the LOW (disabled) state. While the WEL bit is LOW, writes to the CCR or any array address will be ignored (no acknowledge will be issued after the Data Byte). The WEL bit is set by writing a “1” to the WEL bit and zeroes to the other bits of the Status Register. Once set, WEL remains set until either reset to 0 (by writing a “0” to the WEL bit and zeroes to the other bits of the Status Register) or
Characteristics subject to change without notice.
5 of 28
X1227
until the part powers up again. Writes to WEL bit do not cause a nonvolatile write cycle, so the device is ready for the next operation immediately after the stop condition.
RTCF: Real Time Clock Fail Bit—Volatile
This bit is set to a ‘1’ after a total power failure. This is a read only bit that is set by hardware (X1227 inter­nally) when the device powers up after having lost all power to the device. The bit is set regardless of whether V
CC
or V
is applied first. The loss of only
BACK
one of the supplies does not result in setting the RTCF bit. The first valid write to the RTC after a complete power failure (writing one byte is sufficient) resets the RTCF bit to ‘0’.
Unused Bits:
This device does not use bits 3 or 4 in the SR, but must have a zero in these bit positions. The Data Byte output during a SR read will contain zeros in these bit locations.
CONTROL REGISTERS
The Control Bits and Registers, described under this section, are nonvolatile.
Block Protect Bits—BP2, BP1, BP0
The Block Protect Bits, BP2, BP1 and BP0, determine which blocks of the array are write protected. A write to a protected block of memory is ignored. The block protect bits will prevent write operations to one of eight segments of the array. The partitions are described in Table 3 .
Table 3. Block Protect Bits
Protected Addresses
BP2
BP1
BP0
X1227 Array Lock
0 0 0 None (Default) None
180
100
000
000
000
000
000
– 1FF
h
– 1FF
h
– 1FF
h
– 03F
h
– 07F
h
– 0FF
h
– 1FF
h
h
h
h
h
h
h
h
Upper 1/4
Upper 1/2
Full Array
First Page
First 2 pgs
First 4 pgs
First 8 pgs
001
010
011
100
101
110
111
Watchdog Timer Control Bits—WD1, WD0
The bits WD1 and WD0 control the period of the Watchdog Timer. See Table 4 for options.
Table 4. Watchdog Timer Time-Out Options
WD1 WD0
Watchdog Time-Out Period
0 0 1.75 seconds (Factory Default)
0 1 750 milliseconds
1 0 250 milliseconds
1 1 Disabled
ON-CHIP OSCILLATOR COMPENSATION
Digital Trimming Register (DTR) — DTR2, DTR1 and DTR0 (Non-Volatile)
The digital trimming Bits DTR2, DTR1 and DTR0 adjust the number of counts per second and average the ppm error to achieve better accuracy.
DTR2 is a sign bit. DTR2=0 means frequency compensation is > 0. DTR2=1 means frequency compensation is < 0.
DTR1 and DTR0 are scale bits. DTR1 gives 10 ppm adjustment and DTR0 gives 20 ppm adjustment.
A range from -30ppm to +30ppm can be represented by using three bits above.
Table 5. Digital Trimming Registers
DTR Register
Estimated frequency
PPMDTR2 DTR1 DTR0
0 0 0 0 (Default)
0 1 0 +10
0 0 1 +20
0 1 1 +30
100 0
1 1 0 -10
1 0 1 -20
1 1 1 -30
REV 1.1.20 1/13/03
www.xicor.com
Characteristics subject to change without notice.
6 of 28
X1227
Analog Trimming Register (ATR) (Non-volatile)
Six analog trimming Bits from ATR5 to ATR0 are pro­vided to adjust the on-chip loading capacitance range. The on-chip load capacitance ranges from 3.25pF to
18.75pF. Each bit has a different weight for capaci­tance adjustment. Using a Citizen CFS-206 crystal with different ATR bit combinations provides an esti­mated ppm range from +116ppm to -37ppm to the nominal frequency compensation. The combination of digital and analog trimming can give up to +146ppm adjustment.
The on-chip capacitance can be calculated as follows:
C
= [(ATR value, decimal) x 0.25pF] + 11.0pF
AT R
Note that the ATR values are in two’s complement, with ATR(000000) = 11.0pF, so the entire range runs from 3.25pF to 18.75pF in 0.25pF steps.
The values calculated above are typical, and total load capacitance seen by the crystal will include approxi­mately 2pF of package and board capacitance in addi­tion to the ATR value.
See Application section and Xicor’s Application Note AN154 for more information.
– Write one to 8 bytes to the Clock/Control Registers
with the desired clock, alarm, or control data. This sequence starts with a start bit, requires a slave byte of “11011110” and an address within the CCR and is terminated by a stop bit. A write to the CCR changes EEPROM values so these initiate a nonvolatile write cycle and will take up to 10ms to complete. Writes to undefined areas have no effect. The RWEL bit is reset by the completion of a nonvolatile write cycle, so the sequence must be repeated to again initiate another change to the CCR contents. If the sequence is not completed for any reason (by send­ing an incorrect number of bits or sending a start instead of a stop, for example) the RWEL bit is not reset and the device remains in an active mode.
– Writing all zeros to the status register resets both the
WEL and RWEL bits.
– A read operation occurring between any of the
previous operations will not interrupt the register write operation.
WRITING TO THE CLOCK/CONTROL REGISTERS
Changing any of the nonvolatile bits of the clock/con­trol register requires the following steps:
– Write a 02h to the Status Register to set the Write
Enable Latch (WEL). This is a volatile operation, so there is no delay after the write. (Operation preceeded by a start and ended with a stop).
– Write a 06h to the Status Register to set both the
Register Write Enable Latch (RWEL) and the WEL bit. This is also a volatile cycle. The zeros in the data byte are required. (Operation preceeded by a start and ended with a stop).
REV 1.1.20 1/13/03
www.xicor.com
Characteristics subject to change without notice.
7 of 28
X1227
POWER ON RESET
Application of power to the X1227 activates a Power On Reset Circuit that pulls the RESET pin active. This signal provides several benefits.
– It prevents the system microprocessor from starting
to operate with insufficient voltage.
– It prevents the processor from operating prior to sta-
bilization of the oscillator.
– It allows time for an FPGA to download its configura-
tion prior to initialization of the circuit.
– It prevents communication to the EEPROM, greatly
reducing the likelihood of data corruption on power up.
When VCC exceeds the device V
threshold value
TRIP
for typically 250ms the circuit releases RESET, allow­ing the system to begin operation. Recommended slew rate is between 0.2V/ms and 50V/ms.
WATCHDOG TIMER OPERATION
The watchdog timer is selectable. By writing a value to WD1 and WD0, the watchdog timer can be set to 3 dif­ferent time out periods or off. When the Watchdog timer is set to off, the watchdog circuit is configured for low power operation.
Watchdog Timer Restart
The Watchdog Timer is started by a falling edge of SDA when the SCL line is high and followed by a stop bit. The start signal restarts the watchdog timer counter, resetting the period of the counter back to the maximum. If another start fails to be detected prior to the watchdog timer expiration, then the RESET pin becomes active. In the event that the start signal occurs during a reset time out period, the start will have no effect. When using a single START to refresh watchdog timer, a STOP bit should be followed to reset the device back to stand-by mode.
LOW VOLTAGE RESET OPERATION
When a power failure occurs, and the voltage to the part drops below a fixed v
voltage, a reset pulse is
TRIP
issued to the host microcontroller. The circuitry moni­tors the VCC line with a voltage comparator which senses a preset threshold voltage. Power up and power down waveforms are shown in Figure 4. The Low Voltage Reset circuit is to be designed so the RESET signal is valid down to 1.0V.
When the low voltage reset signal is active, the operation of any in progress nonvolatile write cycle is unaffected, allowing a nonvolatile write to continue as long as possi­ble (down to the power on reset voltage). The low voltage reset signal, when active, terminates in progress commu­nications to the device and prevents new commands, to reduce the likelihood of data corruption.
Figure 3. Watchdog Restart/Time Out
t
RSP
t
RSP<tWDO
SCL
SDA
RESET
REV 1.1.20 1/13/03
Start
Note: All inputs are ignored during the active reset period (t
Stop
t
RSP>tWDO
Start
www.xicor.com
t
RSP>tWDO
t
RST
).
RST
Characteristics subject to change without notice. 8 of 28
t
RST
X1227
Figure 4. Power On Reset and Low Voltage Reset
V
TRIP
V
CC
t
PURST
t
R
RESET
t
RPD
t
PURST
t
F
V
RVALID
VCC THRESHOLD RESET PROCEDURE [OPTIONAL]
The X1227 is shipped with a standard VCC threshold (V
) voltage. This value will not change over normal
TRIP
operating and storage conditions. However, in applica­tions where the standard V higher precision is needed in the V
is not exactly right, or if
TRIP
value, the
TRIP
X1227 threshold may be adjusted. The procedure is described below, and uses the application of a nonvol­atile write control signal.
Figure 5. Set V
RESET
V
CC
SCL
SDA
Level Sequence (V
TRIP
01234567
AEh 00h
= desired V
CC
VP = 15V
01234567 01234567 01234567
Setting the V
TRIP
Voltage
It is necessary to reset the trip point before setting the new value.
To set the new V
voltage, apply the desired V
TRIP
threshold voltage to the VCC pin and tie the RESET pin to the programming voltage VP. Then write data 00h to address 01h. The stop bit following a valid write opera­tion initiates the V
programming sequence. Bring
TRIP
RESET to VCC to complete the operation. Note: this operation may take up to 10 milliseconds to complete and also writes 00h to address 01h of the EEPROM array.
value)
TRIP
01h
00h
TRIP
V
CC
Note: BP0, BP1, BP2 must be disabled.
Resetting the V
This procedure is used to set the V voltage level. For example, if the current V and the new V be reset. When V
Voltage
TRIP
must be 4.0V, then the V
TRIP
is reset, the new V
TRIP
to a “native”
TRIP
TRIP
TRIP
is 4.4V
must
TRIP
is some­thing less than 1.7V. This procedure must be used to set the voltage to a lower value.
To reset the new V
voltage, apply more than 5.5V
TRIP
to the VCC pin and tie the RESET pin to the programming voltage VP. Then write 00h to address 03h. The stop bit of a valid write operation initiates the V
programming sequence. Bring RESET to VCC to
TRIP
complete the operation. Note: this operation takes up
REV 1.1.20 1/13/03
www.xicor.com
to 10 milliseconds to complete and also writes 00h to address 03h of the EEPROM array.
For best accuracy in setting V
, it is advised that the
TRIP
following sequence be used.
1.Program V
2.Measure resulting V
TRIP
as above.
TRIP
by measuring the VCC value where a RESET occurs. Calculate Delta = (Desired – Measured) V
3.Perform a V
program using the following formula
TRIP
TRIP
value.
to set the voltage of the RESET pin:
V
= (Desired Value – Delta) + 0.025V
RESET
Characteristics subject to change without notice. 9 of 28