Product Safety Data Sheet
Phaser 8860
Page 1 of 2
_________________________________________________________________________
PRODUCT DESCRIPTION
Phaser 8860 Color Solid Ink Printer
MANUFACTURER INFORMATION
XEROX Corporation
P.O. Box 1000
Wilsonville, Oregon 97070-1000, U.S.A.
PRODUCT DIMENSIONS
Depth Width Height
Phaser 8860 DN 53.3 cm / 21 inches 40.6 cm / 16.0 inches 36.8 cm / 14.5 inches
WEIGHT
28 kg / 60 lbs
ELECTRICAL INFORMATION
Voltage (Volts)
Frequency (Hertz)
Current (Amps)
PRODUCT SAFETY CERTIFICATION
Standard Certifying Body
Low Voltage Directive
CB Report & Certificate
CSA Report
ELECTROMAGNETIC COMPATIBILITY CERTIFICATION
Standard Certifying Body
EMC Directive
EMC Report
100-240 Vac
50/60 Hz
10-5 A
• 2006/95/EC
• IEC 60950-1:2001 (1
• EN 60950-1:2001
• UL 60950-1:2003, 1st Edition
• CSA 60950-1-03, 1
st
Edition)
st
Edition
XEROX Office Group
CSA International
CSA International
• 2004/108/EC
• FCC Part 15, Class A
• EN 55022:1998 +A1:2000 +A2:2003,
Class A
• EN 61000-3-2:2000 +A2:2005
• EN 61000-3-3:1995 +A1:2001
• EN 55024:1998 +A1:2001 +A2:2003
XEROX Office Group
XEROX Office Group
Product Safety Data Sheet
Phaser 8860
Page 2 of 2
_______________________________________________________________________________
POWER CONSUMPTION
Off Mode (W) Power Save (W)
0.3 45.7 103.1 227.1
115 V
Standby (W) Run Mode (W)*
230 V
Off Mode (W) Power Save (W) Standby (W) Run Mode (W)*
0.9 45.9 104.3 239.1
*Hourly rate extrapolated (color default simplex printing).
HEAT OUTPUT
115 V
Off Mode (BTU/hr) Power Save (BTU/hr) Standby (BTU/hr) Run Mode (BTU/hr)*
1.0 156.0 351.9 775.0
230 V
Off Mode (BTU/hr) Power Save (BTU/hr) Standby (BTU/hr) Run Mode (BTU/hr)*
3.1 156.7 356.0 815.9
*Hourly rate extrapolated (color default simplex printing).
NOTE: The electrical power information provided should not be used to define the electrical support required for this product.
Consult your Xerox representative if you require detailed information.
ENVIRONMENTAL LIMITATIONS
Relative Humidity (%) Ambient Temperature (ºC/ºF)
Operating
10% - 80% 10ºC to 32ºC / 50ºF to 90ºF
LIGHT SOURCE
Not applicable
AUDIBLE NOISE
Declared noise emissions in accordance with ISO 9296:1988(E):
Idling Operating
(Enhanced Mode)
LWAd (1B=10dB)
Bystander Position (1.0 m) LpAm = 30 dB (A) LpAm = 56 dB (A)
LWAd = 4.4 B (A) LWAd = 7.2 B (A)
CHEMICAL EMISSIONS
Measured Product Concentration
Ozone
Styrene
Particles (Dust)
2 ppb (0.004 mg/m³)
Not detected
Not detected
OZONE FILTER REPLACEMENT