Description
The Multi-technology Readers feature a rugged design and can be installed almost anywhere. Durable, weatherproof, UV-resistant materials, along with advanced electronics and circuitry, protect readers against inclement weather and exposure to sunlight.
Figure 1. Multi-technology Readers
Multi-technology Readers
Installation Guide
2. Drill two mounting holes a minimum of 3.25” (82.6 cm) apart on the mounting surface of the door frame or wall. Refer to Figure 3.
3. Drill one .625” (1.587 cm) diameter hole in wall for the pigtail wire connection.
4. Follow the cable connection chart. Connect power at the panel when installation is complete.
5. Mount the base plate to the wall using the supplied screws.
6. Install gasket if required, see Figure 2.
7. Install top cover straight on to the reader base. Do not force the cover on. The four cover guides should ensure the connector seats correctly.
Figure 3.
1.750 [44.5]
1.160 [29.5]
Mounting the Reader
1. Find a suitable mounting position on the door frame or wall. Note: For out of doors or wet locations, it is recommended that the gasket provided be installed on the base as shown in Figure 2.
Figure 2. Gasket Installation
5.850 [148.6]
front view side view
Figure 4. Aligning base plate and top cover
8. Verify the connection is secure and install the security screws at the top and bottom of the reader.
9. Place a screw head cover over each of the screws. The screw head cover should be flush with the reader once in place.
Connecting the Cable
Specifications
1. The readers are supplied with a 12-conductor cable pigtail. Ensure the reader wiring is disconnected at the host panel until all connections are made at the reader. Use the cable connection chart below:
Yello w Beeper
Blue Hold
Purple Future
Green Wiegand Data 0 or RS485A
White Wiegand Data 1 or RS485A
Orange Green LED
Brown Red LED
Red Power + DC (6-16 VDC)
Black Ground
Pink Not Used
Gray Not Used
Drain Shield Ground
2. Use a DC Power source between 8-16 volts.
3. Verify the reader is properly grounded by attaching the ground wire to an earth ground connection at the power supply or panel end of the cable.
Testing the Reader
1. Power up the reader. A red LED will light followed by a beeper tone, which indicates the reader is ready.
2. Present a proper card, which has been programmed to operate the reader. * A green LED indicates a registered badge read. * A red LED indicates idle (ready to read) state in the Wiegand mode.
Removing the Cover
1. Remove the plugs and security screws.
2. Slide cover off perpendicular to base.
Trouble Shooting
1. If reader does not behave normally upon installation, verify that cover and base are connected properly:
The reader is shipped unassembled. To assemble, pull cover
away from base and rotate until the connector port on the base is aligned with the connector port on the cover. Snap shut.
2. Only connect wires necessary for use. Cut and/or isolate unused wires. Connecting unnecessary wires may lead to unexpected reader behavior.
3. If multiple reader units are installed in close proximity or back to back, RF interference may result in reduced read range performance.
4. A recurrent triple beep audio sequence may indicate that the cover is not seated properly. Remove cover and check for bent or broken pins in the connector.
Copyright © 2007-2011, XceedID. All rights reserved. Revised 2/1/2011.
Colors Black (standard), charcoal
Power supply Linear DC
Voltage range 8 - 16 VDC
Maximum and Average Current range
XF2110C: 173 mA (max), 155mA (aver) XF2100C: 157 mA (max), 141 mA (aver) XF1100C: 132 mA(max), 116 mA (aver)
Temperature range -31 F to 149 F
-35 C to 65 C
Card read distance Distance can vary depending on
reader, installation conditions and credential type.
Cable distance to panel 200 ft. max (22 gauge)
300 ft. max. (20 gauge) 500 ft. max. (18 gauge)
Wiegand output Up to 200 bits depending
on configuration and card technology
Tamper output Open Collector
Regulatory approvals
UL, CE, and FCC (part 15)
and standards
ISO Standards ISO 14443A
ISO 15693
The voltage specification for this reader is 8-16 VDC. Higher voltage with the specifications provides better performance and cable run distances.
The recommended cable gauge is 18-gauge to 22-gauge. Check with the cable supplier to determine the best choice for the application and installation distance.
FCC compliance
The FCC requires the following statement: This reader uses radio frequency energy and has been tested, and complies with the limits of FCC testing. Changes, modification, or disregard of proper installation and instructions not expressly approved by XceedID, and is strictly prohibited by the FCC and could void the user’s authority to operate the equipment.
a. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
b. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Ordering Information
Product Description
XF -1100 - B (Standard Black)
XF-2100-B (Standard Black)
XF-2110-B (Standard Black)
XF-1100-C (Charcoal) Mullion mount; Wiegand output
XF-2100-C (Charcoal) 1-Gang US mount;
XF-2110-C (Charcoal) 1-Gang US mount; Keypad; Wiegand
Mullion mount; Wiegand output
1-Gang US mount; Wiegand output
1-Gang US mount; Keypad; Wiegand output
Wiegand output
output
Loading...