Xantrex Back Plate for Sine Wave Plus Power Panel Installations
Installation
Instructions
XBP & XBP-DC
973-0030-01-01 A
Revision A
A two-piece, steel back plate is available for creating a unified power panel using one or two Sine Wave Plus Inverter Chargers. The combined panel is designed to accommodate the following components:
•one or two Sine Wave Plus Inverters, or
•one Sine Wave Plus Inverter and a TX Autotransformer
Plus:
•one AC Conduit Box-Long (ACCB-L), and
•one or two DC Conduit Box-Long (DCCB-L). Two DCCB-L s requires the XBP-DC.
The primary panel comes in two parts and measures 46" (89 cm) wide when assembled. If a second DCCB-L is going to be used, an optional plate (XBP-DC) attaches to the right side of the primary panel to extend it to 60” (152.5 cm).
The back plate comes with mounting hooks that can be attached to the panel to hang the components on as they’re installed. It also has conduit pass-thrus for both the ACCB-L and DCCB-L wiring.
The XBP supports the following configurations of Sine Wave Plus Inverter/
Chargers:
•Single-inverter (120 Vac Applications)
•Single-inverter with TX Autotransformer (120 to240 Vac Applications or 240 to 120 Vac Applications)
•Dual-inverter (120 and 240 Vac Applications)
•Dual-inverter with Multiple Renewable Energy Input (120 and 240 Vac Applications)
Xantrex Back Plate
AC Input Sources
Utility Grid
Generator
AC Generators
|
Sine Wave Plus Power Panel |
|
||
|
|
|
C-Series |
C-Series |
|
L1 HOT |
|
|
|
|
|
|
|
00.0 |
GND |
NEU |
|
|
DC Input Sources |
ACCB-L |
xantrex |
Sine Wave Plus Inverter / Charger |
DCCB-L |
|
Renewable Energy
|
Photovoltatic |
|
(PV) Array |
D |
D |
L1 |
L2 |
L1 |
L2 |
IN |
I N |
OUT |
OUT |
Wind
Generator
Hydro
Loads |
|
Energy Storage |
|
Generator
DC Engine
Generators
120 Vac
Loads
June 22, 2004
Figure 1-1 Single Inverter Configuration
Sine Wave Plus Power Panel
C-Series |
C-Series |
|
L1 HOT |
|
|
|
|
|
|
|
00.0 |
GND |
NEU |
|
|
DC Input Sources |
ACCB-L |
xantrex |
Sine Wave Plus Inverter / Charger |
DCCB-L |
|
AC Input Sources |
Renewable Energy |
|
|
|
|
|
|
|
|
|
Photovoltatic |
|
|
|
|
|
|
|
|
(PV) Array |
D |
D |
|
|
|
|
|
|
|
Utility Grid |
|
|
|
|
|
|
|
|
|
L1 |
L2 L1 L2 |
L |
N |
L |
NL1 |
|
|
|
I N |
I N OUT OUT |
2 |
1 |
|
|
||
|
|
|
|
|
|
|
|
Wind |
|
|
|
240 V |
120 |
TX Autotransformer |
Generator |
||
|
|
|
V |
Generator |
|
|
Hydro |
AC Generators |
Loads |
Energy Storage |
|
|
|||
|
|
|
Generator |
|
|
|
DC Engine |
|
|
|
Generators |
|
120 Vac |
240 Vac |
|
|
Loads |
Loads |
|
June 22, 2004
Figure 1-2 Single Inverter Configuration with a TX Autotransformer
2 |
973-0030-01-01 A |
Installation Instructions
Sine Wave Plus Power Panel
C-Series |
C-Series |
AC Input Sources |
L1 HOT |
|
|
|
|
|
|
|
00..00 |
DC Input Sources |
|
ACCB-L |
xantrex |
Sine Wave Plus Inverter / Charger |
DCCB-L |
|
GND
NEU
Renewable Energy
Utility Grid |
|
|
|
|
Photovoltatic |
|
|
|
|
(PV) Array |
|
D |
D |
|
|
|
|
Generator |
|
|
|
xantrex |
Sine Wave Plus Inverter / Charger |
I N IN |
OUT OUT |
|
|||
|
L1 |
L2 |
L1 |
L2 |
|
|
Wind |
AC Generators |
Generator |
|
|
|
Hydro |
Loads |
Energy Storage |
|
|
|
Generator |
|
|
DC Engine |
|
|
Generators |
120 Vac |
240 Vac |
|
Loads |
Loads |
|
June 22, 2004
Figure 1-3 Dual Inverter Configuration
AC Input Sources
Utility Grid
Generator
AC Generators
Sine Wave Plus Power Panel
|
|
|
C-Series |
C-Series |
C-Series |
C-Series |
|
L1 HOT |
|
|
|
|
|
|
|
|
|
00.0 |
|
00.0 |
ACCB-L |
xantrex |
Sine Wave Plus Inverter / Charger |
DCCB-L |
|
DCCB-L |
|
|
GND |
|
|
|
|
DC Input Sources |
|
NEU |
|
|
|
|
Renewable Energy
|
|
|
|
Photovoltatic |
D |
D |
D |
D |
(PV) Array |
|
|
|
xantrex |
Sine Wave Plus Inverter / Charger |
L1 |
L2 |
L1 |
L2 |
|
I N |
I N |
OUT |
OUT |
|
Wind
Generator
Loads |
Energy Storage |
Hydro |
|
|
|||
|
|
|
Generator |
120 Vac |
240 Vac |
|
DC Engine |
Loads |
Loads |
|
Generators |
June 22, 2004
Figure 1-4 Dual Inverter Configurations with Multiple Renewable Energy
973-0030-01-01 A |
3 |
Xantrex Back Plate
The panel is comprised of two plates that fit together and combine to create a solid support for the power system. If dual DCCB-Ls are to be installed, then an extension plate (XBP-DC) is available to complete the panel.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
14” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
23” |
|
|
|
|
|
26” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(36 cm) |
|||
|
|
|
|
|
|
|
(58 cm) |
|
|
|
|
|
(58 cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
G |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
A |
|
|
|
|
|
|
|
H |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
B |
D |
|
D |
|
|
|
H |
|||||
|
|
|
|
B |
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
H |
|
H |
|||
|
|
|
|
|
|
|
C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
35” |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
(89 cm) |
|
|
|
|
E |
|
E |
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
XBP |
|
XBP |
|
XBP-DC |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Left Side |
|
|
|
|
|
Right Side |
|
|
FF
H H
B
A Mounting hook position for ACCB-L
B Conduit Pass-thrus for ACCB-L
C Hand Holds for installing
D Mounting hook positions for SW Plus Inverter #1
E Mounting hook positions for SW Plus Inverter #2
K J
I N
L
F Mounting hook positions for TX Autotransformer
G Mounting hook position for DCCB-L
H Conduit Pass-thrus for DCCB-L
I Mounting Hooks (x6)
J1/4-20x3/4” phillips screws (x20) for mounting the components (ACCB-L, DCCB-L, SW Plus Inverters, and TX Autotransformer)
K10-32x1/2” phillips screws (x12) for the mounting holes
L Mounting Hook for XBP-DC (x1)
M |
M 1/4-20x3/4” phillips screws for |
|
XBP-DC (x4) |
||
|
N10-32x1/2” phillips screws for XBP-DC (x2)
Figure 1-5 Components of the Xantrex Back Plate (XBP and XBP-DC)
4 |
973-0030-01-01 A |