Xantech IR-X10 Installation Instructions Manual

Page 1 Model IR-X10
INSTALLATION INSTRUCTIONS
MODEL IR-X10
INTERFACE MODULE
Section Title
Page
INTRODUCTION....................................................................................... 3
FEATURES AND SPECIFICATIONS .........................................................3
INSTALLATION......................................................................................... 5
IR-X10 SYSTEM COMMANDS .................................................................. 6
GETTING STARTED USING DRAGON DROP-IR SOFTWARE.................. 6
CHOOSING AND LISTING X10 MODULES ............................................... 7
PLACING X10 COMMANDS ON A VIRTUAL CONTROLLER..................... 8
SCENE CONTROL.................................................................................... 9
Programming a Scene ...................................................................... 10
Scenes Setup ................................................................................... 11
Programming an X10 Scene Macro................................................... 12
Transferring Data to a Real Controller ............................................... 13
Page 2 Model IR-X10
© 2002 Xantech Corporation.
Model IR-X10 Page 3
© 2002 Xantech Corporation.
INTRODUCTION
The IR-X10, Figure 1, serves to connect the Xantech IR bus to the X10
®
Power Line Interface (PL513, PSC05, etc). Specifically, the IR-X10 converts unique IR control codes, generated by the Dragon Drop-IR software program, into X10 commands. This permits the unique lighting and control functions of the X10 system to be easily integrated into Xantech IR controlled whole-house AV systems. Refer to the Dragon Drop-IR Installation and Programming Instructions and the X10 User Manuals when planning overall configuration and operational details.
X10
RJ11
Output Port
Figure 1 – The IR-X10 Interface Module
FEATURES AND SPECIFICATIONS
Converts specific Dragon Drop-IR code into X10 control signals
IR signal & power inputs - plug-in screw-type terminals for four­conductor connections handles wire sizes from 24 to 12 gauge
Opto-coupled IR IN and separate IR Gnd permits IR input to be isolated from chassis and power supply grounds, where needed
IR IN accepts Xantech IR bus output from any of the Xantech IR receivers, keypads, connecting blocks, controllers, etc.
X10 output jack – RJ11 modular connector
• RJ11-to-RJ11 cable included
Power requirements – 12 VDC ± 1.5V @ 25mA
Mounting – flanges, plus supplied screws permit easy mounting to flat surfaces
Dimensions – 4-3/8” L x 1-7/8” W x 1-1/8” H (111mm x 48mm x 29mm)
Page 4 Model IR-X10
© 2002 Xantech Corporation.
+12 VDC
IR OUT
GND
780-10
J-BOX RECEIVER
789-44
Connecting Block
Satellite Receiver
AV
Receiver
VCR
To 120 V AC (unswitched)
782-00
Power
Supply
283M
Emitter
283M
Blink IR
ROOM 2
12VDC
+12 VDC
GND
STATUS
IR IN
EMITTERS
IR
RCVR
789-44
CONNECTING BLOCK
®
283M
Emitter
Smart Pad
GND
IR OUT
+12V
Power Line
Control Link
To Additional
Modules as Needed
X10
Power Line Interface
X10
Lamp Module
X10
Appliance Module
4-Conductor Cable
(RJ11 to RJ11, included)
Mono Mini-Plug to Stripped Ends,
2-Conductor Cable (part no. 06015900, not included)
Appliance Module
Lamp Module
Hand Held
Remote
GND
IR OUT
+12V
780-10
J-BoxIR Receiver
ROOM 1
White Striped
Side +
Figure 2 – Typical Multi-Room System Using the IR-X10
Model IR-X10 Page 5
© 2002 Xantech Corporation.
INSTALLATION
Figure 2 is a typical multi-room installation where X10 control is part of the
system. A mixture of Xantech SmartPad3 keypads and IR receivers are the source of the IR control signals for both the AV products and X10. The systems is configured as follows: Note: Refer to your X10 manual for proper system configuration of X10 components.
1. Using 2-conductor cable (22AWG up to 600’, 20AWG up to 2000’ and 18AWG up to 5000’), connect PWR GND, and +12VDC connections from the IR-X10 module to the appropriate terminals on the connecting block.
2. Using a Mono Mini-Plug to Stripped Ends 2-Conductor cable (Xantech PN#06015900, not included), plug the Mini-Plug end into an available Emitter out on the Connector Block and wire the ‘Stripped End' in IR IN (White Stripe) and IR GND on the IR-X10. Note: If using Emitter Out is not practical, in Step #1 use 3-
Conductor (22AWG up to 600’, 20AWG up to 2000’ and 18AWG up to 5000’) to connect IR IN, PWR GND, and +12VDC connections from the IR-X10 module to the appropriate terminals on the connecting block. You must also connect a jumper wire from IR GND to PWR GND on the IR-X10.
3. Connect one end of the furnished RJ11 cable to the output port of the
IR-X10 module and connect the other end into the X10 Power Line Interface (not included).
4. Plug the X10 Power Line Interface into an un-switched AC Line outlet.
5. The Dragon Drop-IR software is used to program learning remotes (used with the IR receivers), in addition to the SmartPads, with the IR­X10 control commands.
Note: The Xantech RC68+ (or RC68) Programmer Remote cannot be
used to program IR-X10 commands! Use of Dragon Drop-IR is explained in the next section.
Loading...