Description: The XPS4 is a mechanical, decorative-style, non-dimming, Single-Pole/3-Way wall switch rated for 20amps. It can handle ON/
OFF loads as follows: Incandescent (120V Standard or Halogen) Bulbs, Low Voltage Transformers, High Wattage Flood Lights, Fluorescent
Lighting, Pumps/Motors and Appliances. The White LED Indicates its "ON/OFF" status. The dim LED will remain ON when the switch is OFF (making it easier to find in darker conditions) and the LED will turn OFF when the switch is ON. Its decorative paddle permits local operation of
the switch. The X10 Address Code Dials set the House Code and Unit Number and are located behind the paddle.
Specific Requirements: 120VAC, 20amps
Neutral Wire IS required. Ground Wire is not used.
tional / Supplementary Devices & Modules:
Op
XPSS - Slave Switch is required for existing 3-Way Installations. XPSPAL Almond Rocker in package of 10ea. for both XPS4 and XPSS.
XPT1 - Alternate Slave Switch (Transmitter) for existing and new 3-Way/4-way Installations.
XPF - Filter to reduce noise, from load, degrading switch operation.
Non-X10 Contactor - Heavy Load Relay device for High Intensity Discharge (HID) Lighting and other heavy-duty loads.
X10 Protocol:
House Code Dial - Letters A-P (default "A") Unit Number Dial - Numbers 1-16 (default "1") Each
X10 Receiver Module is set to a unique Unit Number or to an identical Unit Number as desired.
Each X10 Controller operating a specific set of Receiver Modules must be set to the same House (Letter) Code as the Receivers they are
controlling.
Responds to ALL LIGHTS ON command
Electrical Protocol:
Nearly all residential homes are wired SPLIT-PHASE. Each 120V Pha se is NOT directly connected with the other 120V Phase. If after installation,
an X10 Receiver does not respond to a remote Controller, then check to ensure that the breaker serving the X10 Receiver is on the same phase as
the Controller. If not, the breaker can be changed to the opposite phase. An alternative solution is recommended, to install a Phase Coupler for
improving remote communications throughout the home. See the XPCR Phase Coupler product for additional information.
Installation: for Single-Pole operation
1. Turn power OFF at Circuit Breaker
2. Pull-out the existing wall switch from the switch box.
3. Inspect inside the wall switch box for existence of white neutral wire(s) capped-off. If no white neutral wires exist, STOP. You CANNOT use the
XPS4 unless you run a neutral wire to this box.
4. Remove the existing wall switch. Two wires remain protruding out of switch box. One is HOT, the other goes to the light/load. They may be the
same color.
5. With Breaker ON, determine which protruding wire is HOT. Use a voltmeter and measure between ground and each wire individually.
One will read 120V, the other 0V.
6. With Breaker OFF, Connect a white neutral wire to the NEUTRAL Terminal. You may have to tap into a neutral wire bundle with an additional
white wire 6-8" long.
7. Connect the HOT wire to the LINE Terminal, connect the other wire to the LOAD Terminal.
8. No connection is needed at the Control Screw Terminal.
9. Re-check all connections, Turn power ON at Circuit Breaker.
10. Press switch paddle once, you will hear the switch CLICK and the light should turn ON. Press paddle again, you will hear the switch CLICK and
the light should turn OFF.
11. You are now ready to control the switch with an X10 Remote Control Module: desktop, wireless handheld, Security Panel, etc. The default
address is "A1". If you wish to change the code, the Code Dials are behind the paddle. Remove the paddle with a small flat screwdriver applied to
the side of the paddle at the center fulcrum point. Insert screwdriver in small gap space between switch plate and paddle and flip the paddle up
from its side.
12. Mount the Switch in the wall box and attach the switch cover plate.
20A Wall Switch - ReceiverXPS4
3-Way Installation - Existing
Active
LED
Dials Behind
Rock
er
In-Active
LED
Switched Leg
A
Control to Switch
to Light
LOAD
1
Neutral
NEUTRAL
XPS4
Master
Traveler Wires
LINE
Line to Live
(HOT)
LIVE
XPSS
Slave
Installation: for 3-Way operation - Existing
Note:
A 3-Way system, by definition, means two existing wall switches which operate one light load (can be multiple lights if all come on
together).
1. Turn power OFF at Circuit Breaker.
2. Pull-out the existing 3-way wall switches from the two switch boxes.
3. Remove the common-side wire (by itself) from the two switches. In one switch box, that single wire is HOT, in the other switch box, that single
wire goes to the light.
4. With Breaker ON, determine which wire is HOT. Use a voltmeter and measure between ground and each wire individually. One will read 120V,
the other 0V. Turn Breaker OFF. Mark the wires as to which one is HOT and which one goes to the light.
5. The Slave Switch is installed in the switch box which has the HOT wire. The Master Switch is installed in the switch box that has the wire that
goes to the light.
6. Inspect inside the wall switch box (that has the wire going to the light) for existence of white neutral wire(s) capped-off. If no white neutral wires
exist, STOP. You CANNOT use the XPS4 unless you run a neutral wire to this box.
7. With Breaker OFF, remove the existing two wall switches. Three wires (minimum) remain protruding out of each switch box. At the Slave switch
box, one is HOT, the other two wires are the traveler wires. They may be the same color, normally they are different colors. At the Master switch
box, one is the Light wire, the other two wires are the traveler wires. They may be the same color, normally they are different colors.
8. With Breaker OFF, install the Slave Switch first. HOT wire goes to LIVE (either terminal, they are a common bus), One Traveler wire also goes to
LIVE, the second Traveler wire goes to SWITCH.
9. With Breaker OFF, install the Master Switch second. The One HOT Traveler wire goes to LINE, the second Traveler wire goes to CONTROL.
The Light wire goes to LOAD. Connect a white neutral wire to the NEUTRAL Terminal. You may have to tap into a neutral wire bundle with an
additional
white wire 6-8" long.
8. Re-check all connections, Turn power ON at Circuit Breaker.
9. Press Master Switch paddle once, you will hear the switch CLICK and the light should turn ON. Press paddle again, you will hear the switch
CLICK and the light should turn OFF. Press the Slave Switch paddle once, and the light should turn ON, (the Master will CLICK). Press the Slave
Switch paddle again, and the light should turn OFF (the Master will CLICK).
10. You are now ready to control the switch with an X10 Remote Control Module: desktop, wireless handheld, Security Panel, etc. The default
address is "A1". If you wish to change the code, the Code Dials are behind the paddle of the Master Switch only. Remove the paddle with a small
flat screwdriver applied to the side of the paddle at the center fulcrum point. Insert screwdriver in small gap space between switch plate and paddle
and flip the paddle up from its side.
11. Mount the Switch(s) in the wall box(s) and attach the switch cover plates.
LIVE
HOT
Switched Leg
to Light
Load
Neutral
Note: 4-Way circuits can be replaced using the XPS4 and two (2) XPSS Slave Switches.
This picture represents the switches in a "3-Way - 4-Way - 3-Way" circuit.
Simply connect an XPSS in the middle box (noted by 4 wires removed from the existing 4-Way switch):
1. Connect the 2 traveler wires that make connection from the Switch connection on the first
XPSS Slave and the CONTROL screw connection on the XPS4 Master, both to the Switch terminal on this 4-Way XPSS.
2. Connect the 2 traveler wires that make connection from the Live connection on the first
XPSS Slave and the LINE screw connection on the XPS4 Master, both to the Live terminal on this 4-Way XPSS.
Neutral
(White)
Control SWITCH SWITC
Line LIVE
XPS4
Master
Traveler Wires
XPSS
Slave
LIVE LIVE
H
XPSS
Slave
HOT
(Black)
LIVE
20A Wall Switch - ReceiverXPS4
3-Way Installation - Existing/Alternate
Switched Leg
to Light
LOAD
Neutral
NEUTRAL
Active
LED
A
1
Dials Behind
Rocker
LINE
HOT
NEUTRAL
Traveler Wires
White
1
A
Black
HOT
XPS4
Master
Installation: for 3-Way / 4-Way operation - Existing/Alternate
Note:
A 3-Way / 4-Way system, by definition, means two or more existing wall switches which operate one single light (can be multiple
lights if all come on together). In this alternate installation instruction, the XPSS switch may not work well due to longer traveler wire
runs between multiple switches. The XPT1 Transmitter will work over the longer wires between multiple switches.
1. Turn power OFF at Circuit Breaker.
2. Pull-out the existing 3-way wall switches from the two switch boxes.
3. Remove the common-side wire (by itself) from the two switches. In one switch box, that single wire is HOT, in the other switch box, that single
wire goes to the light.
4. With Breaker ON, determine which wire is HOT. Use a voltmeter and measure between ground and each wire individually. One will read 120V,
the other 0V. Turn Breaker OFF. Mark the wires as to which one is HOT and which one goes to the light.
5. The Alternate XPT1 Slave Switch (Transmitter) is installed in the switch box which has the HOT wire. The Master Switch is installed in the switch
box that has the wire that goes to the light.
6. Inspect inside the wall switch box (that has the wire going to the light) for existence of white neutral wire(s) capped-off. If no white neutral wires
exist, STOP. You CANNOT use the XPS4 unless you run a neutral wire to this box. (In this case, if Neutral is av
then one of the traveler wires can be utilized to carry Neutral to the Master Switch or vice versa).
7. With Breaker OFF, remove the existing two wall switches. Three wires (minimum) remain protruding out of each switch box. At the Slave switch
box, one is HOT, the other two wires are the traveler wires. They may be the same color, normally they are different colors. At the Master switch
box, one is the Light wire, the other two wires are the traveler wires. They may be the same color, normally they are different colors.
8. With Breaker OFF, install the Alternate XPT1 Slave Switch (Transmitter) first. The HOT wire goes to the XPT1 Black wire bundled with one
Traveler wire, the second Traveler wire goes to the XPT1 White wire (assuming Neutral will be picked up at the Master box).
9. With Breaker OFF, install the Master Switch second. The One HOT Traveler wire goes to LINE, the second Traveler wire goes to the NEUTRAL
Terminal together with a white neutral wire from the box NEUTRAL, as previously mentioned. You may have to tap into a neutral wire bundle with
an additional white wire 6-8" long. The Light wire goes to LOAD.
10. There will be no connection to the CONTROL TERMINAL needed.
11. Re-check all connections, Turn power ON at Circuit Breaker.
12. Press Master Switch paddle once, you will hear the switch CLICK and the light should turn ON. Press paddle again, you will hear the switch
CLICK and the light should turn OFF. Press the alternate XPT1 Slave Switch Transmitter "ON" position once, and the light should turn ON, (the
Master will CLICK). Press the alternate XPT1 Slave Switch Transmitter "OFF" position once, and the light should turn OFF (the Master will CLICK).
13. You are now ready to control the switch with an X10 Remote Control Module: desktop, wireless handheld, Security Panel, etc. The default
address is "A1" for both switches. If you wish to change the code, the Code Dials are behind the paddle/keypad. Remove the paddle with a small
flat screwdriver applied to the side of the paddle at the center fulcrum point. Insert screwdriver in small gap space between switch plate and paddle
and flip the paddle up from its side. Remove the Keypad from the Transmitter, with fingers pulling from bottom, to change the XPT1 Address Code.
14. Mount the Switch(s) and Transmitter(s) in the wall box(s) and attach the switch cover plates.
NOTE: You can use additional XPT1 Wall Transmitter Switches to augment existing 4-Way or greater systems. Continue using the existing traveler
wires to carry HOT and Neutral to the additional existing Switch Box locations. Then install the XPT1 in those additional boxes with traveler wires,
connecting to HOT and Neutral
Note:
both switches
set to same Address
Code
XPT1
Alternate Slave
(Transmitter)
ailable at the Slave position,
20A Wall Switch - ReceiverXPS4
3-Way Installation - Create New
Switched Leg
to Light
LOAD
Active
LED
A
1
Dials Behind
Rocker
NEUTRAL
White
1
A
Black
HOT
NEUTRAL
LINE
Neutral
XPS4
Master
HOT
Installation: for 3-Way operation - Create New
Note:
A 3-Way system, by definition, means two existing wall switches which operate one single light (can be multiple lights if all come
on together). In this NEW installation instruction, there are no traveler wires between switches. The XPT1 Transmitter will be connected
to HOT and NEUTRAL only. It will communicate with the Master Switch via existing power wires.
1. Turn power OFF at Circuit Breaker.
2. Pull-out the existing single-pole wall switch from the switch box.
3. Inspect inside the wall switch box for existence of white neutral wire(s) capped-off. If no white neutral wires exist, STOP. You CANNOT use the
XPS4 unless you run a neutral wire to this box.
4. Remove the existing wall switch. Two wires remain protruding out of switch box. One is HOT, the other goes to the light/load. They may be the
same color.
5. With Breaker ON, determine which wire is HOT. Use a voltmeter and measure between ground and each wire individually. One will read 120V,
the other 0V.
6. With Breaker OFF, connect a white neutral wire to the NEUTRAL Terminal. You may have to tap into a neutral wire bundle with an additional
white wire 6-8" long.
7. Connect the HOT wire to the LINE Terminal, connect the other wire to the LOAD Terminal.
8. There will be no connection to the CONTROL TERMINAL needed.
9. Re-check all connections, Turn power ON at Circuit Breaker.
10. Press switch paddle once, you will hear switch CLICK and light should turn ON. Press paddle again, you will hear switch CLICK and light
should turn OFF.
11. You are now ready to control the switch with an X10 Remote Control Module: desktop, wireless handheld, Security Panel, etc. The default
address is "A1". If you wish to change the code, the Code Dials are behind the paddle. Remove the paddle with a small flat screwdriver applied to
the side of the paddle at the center fulcrum point. Insert screwdriver in small gap space between switch plate and paddle and flip the paddle up
from its side.
12. Install the XPT1 Wall Transmitter Switch. You will need an existing or new switch box which has power run to it.
13. With Breaker OFF, connect the XPT1 Black wire to HOT, connect the XPT1 white wire to Neutral. Turn Breaker ON.
14. Press the XPT1 Switch "ON" position once, and the light connected to the Master Switch should turn ON, (the Master will CLICK). Press the
XPT1 Switch "OFF" position once, and the light should turn OFF (the Master will CLICK).
15. To change the XPT1 Address Code, remove the Keypad, with fingers pulling from bottom, then turn the dials, with small flat screwdriver, to the
desired Address Code. Keep the XPS4 and XPT1 codes identical.
16. Mount the Switch(s) and Transmitter(s) in the wall box(s) and attach the switch cover plates.
Note:
set to same Address
Code
both switches
XPT1
Transmitter
NOTE: You can use additional XPT1 Wall Transmitter Switches to augment new 4-Way or greater systems. You will need additional wall switch
boxes with power run to them. Then install the XPT1 Transmitter, connecting HOT and Neutral.
2 YEAR LIMITED WARRANTY x10.com (X10), a division of Authinx Inc., warrants this product to be free from defective material and
workmanship for a period of 2 years from the original date of purchase at retail. X10 agrees to repair or replace, at its sole discretion, a
defective product if returned to X10 within the warranty period and with proof of purchase. If service is required under this warranty:
Call 1-888-384-0969, visit www.x10.com, or email support@x10.com