WB-CB-500-*
JOB:____________________ ITEM:_________
* 1 = One Pump
1/2 HP CHILL BOSS ICE BANK LINE CHILLER
REFRIGERATION: Air-Cooled: 1/2 HP, R134a Condensing Unit
3000 BTU Output
NOTE: 12" clearance required on on sides for optimum
air flow maintenance.
ELECTRICAL: No pump: 115 Volt AC, 60 hZ, 1 phase, 11.9 Full Load Amps
Dedicated 20 Amp circuit is required
Maximum Fuse / HACR Breaker: 20 Amp
Includes six foot cord with NEMA 5-15P grounded plug.
One Pump: 115 Volt AC, 60 hZ, 1 phase, 18.1 Full Load Amps
Dedicated 30 Amp circuit is required
Maximum Fuse / HACR Breaker: 30 Amp
Includes six foot cord with NEMA L5-30P grounded plug.
COOLING CIRCUITS: Four, 24’ Long Dual,1/4" ID cooling coils, with
3/8" Barbed Inlet/Outlet Fittings.
DIMENSIONS: Height: 26"
Width: 26"
Depth: 15-1/4"
WEIGHT: Shipping: 250# (includes packaging)
Operating: 275#
ICE BANK CAPACITY: 10 U.S. Gallons of Tap Water
PERFORMANCE: Two, 12 ounce drinks per minute at less than
40º F, 300 twelve ounce continuous drinks
until ice bank depletion (3600 ounces total)
MAXIMUM TUBING LENGTH: 50' with optional Add-A-Pump Kit
OPTIONS: 6" Adjustable Legs (up to 7") (p/n WB-BB-L)
Add-A-Pump Kit (p/n WB-BB-GRP-115)
WB-CB-500
Includes:
Six-foot long
cord
with
NEMA 5-15P,
grounded plug.
WB-CB-500-1
Includes:
Six-foot long
cord
NEMA L5-30P
grounded plug.
with
18
WB-CB-500-1 WB-CB-500
REV061108 CB500 SPECS. pub