WB-BB-300-1 |
JOB:____________________ ITEM:_________ |
1/3 HP GLYCOL LINE CHILLER WITH ONE PUMP
REFRIGERATION: Air-Cooled: |
1/3 HP, R134a Condensing Unit |
|
|
|
2000 BTU Output |
|
NOTE: |
12" clearance required on on sides for optimum |
|
|
air flow maintenance. |
ELECTRICAL: |
|
115 Volt AC, 60 hZ, 1 phase, 14 Full Load Amps |
|
|
Dedicated 20 Amp circuit is required |
|
|
Maximum Fuse / HACR Breaker: 20 Amp |
|
|
Includes six-foot cord with NEMA 5-20P |
|
|
grounded plug. |
RECIRCULATING PUMP: |
One 100 GPH, Brass Recirculation Duty |
|
RECIRCULATING MOTOR: |
1/3 hp (6.2 Amp) |
|
DIMENSIONS: |
Height: |
26" |
|
Width: |
26" |
|
Depth: |
15-1/4" |
WEIGHT: |
Shipping: |
225# |
|
Operating: |
250# |
COOLANT CAPACITY: |
6 U.S. Gallons ** |
|
|
|
(3 gallons glycol plus 3 gallons water) |
MAXIMUM CONDUIT LENGTH: |
175' |
|
OPTIONS: |
6" Adjustable Legs (up to 7") |
|
|
Additional Recirculating Pump and Motor Kit |
|
|
|
** Add one gallon of coolant mixture (50% glycol plus 50% water) per 100 feet of Conduit
Includes: Six-foot long cord with NEMA 5-20P, grounded plug.
BB SPECS. pub |
REV061108 |
|
|