WB-BB-LP-1000-*
* 1 = One Pump, 2 = Two Pumps, 3 = Three Pumps, 4 = Four Pumps
LOW PROFILE 1 HP GLYCOL LINE CHILLER
REFRIGERATION: Air-Cooled: 1 HP, R22 Condensing Unit
7800 BTU Output
NOTE: 12" clearance required on on sides for optimum
air flow maintenance.
ELECTRICAL: One Pump: 208 Volt AC, 60 hZ, 1 phase, 11.9 Full Load Amps
Dedicated 20 Amp circuit is required
Maximum Fuse / HACR Breaker: 20 Amp
Includes six foot cord with NEMA 6-15P grounded plug.
Two Pumps: 208 Volt AC, 60 hZ, 1 phase, 14.2 Full Load Amps
Dedicated 25 Amp circuit is required
Maximum Fuse / HACR Breaker: 25 Amp
Includes six foot cord with NEMA 6-20P grounded plug
Three Pumps: 208 Volt AC, 60 hZ, 1 phase, 16.5 Full Load Amps
Dedicated 25 Amp circuit is required
Maximum Fuse / HACR Breaker: 25 Amp
Includes six foot cord with NEMA L6-30P grounded plug
Dedicated 30 Amp circuit is required
Maximum Fuse / HACR Breaker: 30 Amp
Includes six foot cord with NEMA L6-30P grounded plug
RECIRCULATING PUMP: 100 GPH, Brass Recirculation Duty
RECIRCULATING MOTOR: 1/3 hp (2.3 Amps each)
Four Pumps: 208 Volt AC, 60 hZ, 1 phase, 18.8 Full Load Amps
DIMENSIONS: Height: 17-1/2"
Width: 38"
Depth: 27"
WEIGHT: Shipping: 320#
Operating: 350#
COOLANT CAPACITY: 10 U.S. Gallons **
(5 gallons glycol plus 5 gallons water)
MAXIMUM CONDUIT LENGTH: 500'
OPTIONS: 6" Adjustable Legs (up to 7")
Additional Pump and Motor Kit
** Add one gallon of coolant mixture (50% glycol plus 50% water) per 100 feet of Conduit
JOB:____________________ ITEM:_________
WB-BB-LP-1000-1
Includes:
Six-foot long
cord
with
NEMA 6-15P
grounded plug.
WB-BB-LP-1000-2
Includes:
Six-foot long
cord
NEMA 6-20P
grounded plug.
with
WB-BB-LP-1000-3
WB-BB-LP-1000-4
Includes:
Six-foot long
cord
NEMA L6-30P
grounded plug
with
WB-BB-LP-1000-1 and WB-BB-LP-1000-2 WB-BB-LP-1000-3 and WB-BB-LP-1000-4
BB1000 LP SPECS. pub REV061008