WB-BB-1500-*
JOB:____________________ ITEM:_________
* 1 = One Pump, 2 = Two Pumps, 3 = Three Pumps, 4 = Four Pumps
1-1/2 HP GLYCOL LINE CHILLER
REFRIGERATION: Air-Cooled: 1-1/2 HP, R134a Condensing Unit
12,000 BTU Output
NOTE: 12" clearance required on on sides for
optimum air flow maintenance.
ELECTRICAL: One Pump: 208 Volt AC, 60 hZ, 1 phase, 15.8 Full Load
Amps. Dedicated 25 Amp circuit is required
Maximum Fuse / HACR Breaker: 25 Amp,
Includes six foot cord with NEMA 6-20P
grounded plug.
Two Pumps: 208 Volt AC, 60 hZ, 1 phase, 18.1 Full Load
Amps. Dedicated 30 Amp circuit is required.
Maximum Fuse / HACR Breaker: 30 Amp
Includes six foot cord with NEMA L6-30P
grounded plug.
Three Pumps: 208 Volt AC, 60 hZ, 1 phase, 20.4 Full Load
Amps. Dedicated 35 Amp circuit is required
Maximum. Fuse / HACR Breaker: 35 Amp
Includes six foot cord with NEMA L6-30P
grounded plug
Four Pumps: 208 Volt AC, 60 hZ, 1 phase, 22.7 Full Load
Amps. Dedicated 35 Amp circuit is required.
Maximum. Fuse / HACR Breaker: 35 Amp.
Includes six foot cord with NEMA L6-30P
grounded plug.
RECIRCULATING PUMP: 100 GPH, Brass Recirculation Duty
RECIRCULATING MOTOR: 1/3 hp (2.3 Amps each )
DIMENSIONS: Height: 28-1/2"
Width: 34"
Depth: 20"
WEIGHT: Shipping: 350#
Operating: 370#
COOLANT CAPACITY: 10 U.S. Gallons **
(5 gallons glycol plus 5 gallons water)
MAXIMUM CONDUIT LENGTH: 1000'
OPTIONS: 6" Adjustable Legs (up to 7")
Additional Pump and Motor Kit
** Add one gallon of coolant mixture (50% glycol plus 50% water) per 100 feet of Conduit
WB-BB-1500-1
Includes:
Six-foot long
cord
with
NEMA 6-20P
grounded plug
WB-BB-1500-2
WB-BB-1500-3
WB-BB-1500-4
Includes:
Six-foot long
cord
with
NEMA L6-30P
grounded plug
WB-BB-1500-3 and WB-BB-1500-4
WB-BB-1500-1
WB-BB-1500-2
BB1500 SPECS. pub REV061108