P R O W A L L C H I M N E Y V E N T I L A T I O N H O O D S
I N STA L L AT I O N I N S T RU C T I O N S
READ AND SAVE THESE IN STRUCTIONS
C O N TA C T
I N F O R M A T I O N
Wolf Customer
Service:
800-332-9513
Website:
wolfappliance.com
As you follow these instructions, you will
notice WARNING and CAUTION symbols.
This blocked information is important for the
safe and efficient installation of Wolf equipment. There are two types of potential
hazards that may occur during installation.
signals a situation where minor injury or
product damage may occur if you do not
follow instructions.
states a hazard that may cause serious
injury or death if precautions are not
followed.
READ AND SAVE THESE INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF A
RANGE TOP GREASE FIRE:
A)
Never leave surface units unattended at
high settings. Boilovers cause smoking and
greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
B)
Always turn hood ON when cooking at high
heat or when flambéing food (crêpes suzette,
cherries jubilee, peppercorn beef flambé).
C)
Clean ventilating fans frequently. Grease
should not be allowed to accumulate on fan
or filter.
D)
Use proper pan size. Always use cookware
appropriate for the size of the surface
element.
Another footnote we would like to identify is
IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation.
WOLF®is a registered trademark of Wolf Appliance, Inc.
WARNING – TO REDUCE THE RISK OF
INJURY TO PERSONS IN THE EVENT OF
A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1)
SMOTHER FLAMES with a close-fitting lid,
baking sheet or metal tray, then turn off the
burner. BE CAREFUL TO PREVENT BURNS.
IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE
DEPARTMENT.
2)
NEVER PICK UP A FLAMING PAN—You
may be burned.
3)
DO NOT USE WATER, including wet dishcloths or towels—This could cause a violent
steam explosion.
4)
Use an extinguisher ONLY IF:
A. You own a class ABC extinguisher and
you know how to operate it.
B. The fire is small and contained in the
area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to
an exit
*Based on kitchen fire safety tips published by
NFPA.
W O L F P R O W A L L C H I M N E Y V E N T I L A T I O N H O O D S
I N S TA L L AT I O N R E Q U I R E M E N T S
IMPORTANT NOTE:
This installation must be
completed by a qualified installer or Wolf
authorized service center technician.
Installer:
Please read the entire Installation
Instructions prior to installation. Save these
instructions for the local inspector’s reference, then leave them with the homeowner.
Homeowner:
Please read and keep these
instructions for future reference and be sure
to read the entire use & care information
prior to use.
Any questions or problems about the installation should be directed to your Wolf dealer or
Wolf Appliance, Inc. at 800-332-9513. You can
also visit our website at wolfappliance.com.
IMPORTANT NOTE:
This appliance must be
installed in accordance with national electrical
codes, as well as all state, municipal and local
codes. The correct voltage, frequency and
amperage must be supplied to the appliance
from a dedicated, grounded circuit which is
protected by a properly sized circuit breaker or
time delay fuse. The proper voltage, frequency,
and amperage ratings are listed on the product
rating plate.
WARNING – TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
A)
Installation work and electrical wiring
must be done by qualified person(s) in
accordance with all applicable codes and
standards, including fire-rated construction.
B)
When cutting or drilling into wall or ceiling,
do not damage electrical wiring and other
hidden utilities.
C)
Ducted fans must always be vented to the
outdoors.
The hood motor has a thermal overload
which will automatically shut off the
motor if it becomes overheated. The
motor will restart when it has cooled
down. If the motor continues to shut off
and restart, have the hood serviced.
AT I N G P L A T E
R
I N F O R M AT I O N
Model Number
Serial Number
Record the model and serial numbers before
installing the hood. Both numbers are listed on
the rating plate, located on the back wall of the
hood shell. Refer to the illustration below.
Rating plate located
inside back wall
Rating plate location
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
W O L F P R O W A L L C H I M N E Y V E N T I L A T I O N H O O D S
all Chimney Hood
W
Wall Chimney Hood
(R) Rail Option
L I S T O F M AT E R I A L S
The following is a list of materials shipped
with the Wolf pro wall chimney hood.
Stainless steel wall chimney hood
Transition with backdraft damper—
attached inside hood (needs to be removed)
Decorative stainless steel rail and installation components— (R) model hoods only
Two control knobs
Filters and grease cups (installed in hood)
Wood mounting strip
Installation package
Installation Instructions
Use & care information and product
registration card
Wolf logo nameplate
I N S TA L L AT I O N C O N S I D E R A T I O N S
Wolf pro wall chimney ventilation hoods are
recommended for use with all Wolf cooking
appliances.
Proper installation is the responsibility
of the installer. Product failure due to
improper installation is not covered
under the Wolf warranty. Refer to the
Wolf pro ventilation hoods use & care
information for warranty details, or visit
the contact & support section of our
website, wolfappliance.com.
Make sure you have the tools and materials
necessary for proper installation.
Warranty service must be performed by a
Wolf authorized service center. Wolf is not
responsible for service required to correct a
faulty installation.
IMPORTANT NOTE:
Wolf pro ventilation
hoods are shipped without the blower
assembly. Wolf internal, in-line and remote
blower assemblies are available, refer to page
17. Use only a Wolf blower with the pro wall
chimney hood.
IMPORTANT NOTE:
Wolf recommends that
the pro wall chimney hood be installed 30"
(762) to 36" (914) above the countertop.
Rail option (R) wall chimney hoods come with
a classic stainless steel decorative rail and
stand-offs. Optional platinum or brass rails are
available to match Wolf dual fuel range bezels.
Contact your Wolf dealer for details.
If you are installing an optional duct cover with
the pro wall chimney hood, refer to instructions on page 10 before installing the hood.
When performing installation, servicing
or cleaning the unit, it is recommended
to wear safety glasses and gloves.
4
I N S TA L L AT I O N I N S T R U C T I O N S
TOP WIDTH
S
UBTRACT 18" (457) FROM OVERALL WIDTH
O
VERALL WIDTH
4" (
102)
131/2"
(343)
24" (610)
OVERALL DEPTH
18" (457)
O
VERALL
H
EIGHT
2"
(51)
3
/4" (19)
DIAMETER
O
F RAIL
E
6"
(152)
5"
(127)
LOCATION OF
ELECTRICAL
30" TO 36"
(762–914)
TO COUNTERTOP
30" TO 36"
(762–914)
TO COUNTERTOP
18" (457)
HEIGHT
OF HOOD
24" (610)
DEPTH OF HOOD
WIDTH OF HOOD
NOTE: Pro wall chimney hoods have a vertical discharge.
E L E C T R I C A L R E Q U I R E M E N T S
Wolf pro wall chimney ventilation hoods
require a separate, grounded 110/120 V AC,
60 Hz power supply. The service should have
its own 15 amp circuit breaker. Locate the
electrical supply through the top of the hood
as shown in the installation specifications
illustration below. Refer to install wiring on
pages 12–13.
You must follow all national electrical code
regulations. In addition, be aware of local
codes and ordinances when installing your
service.
OV E R A L L D I M E N S I O N S
P R O W A L L C H I M N E Y H O O D S
Overall Widths36" (914), 42" (1067),
48" (1219), and 54" (1372)
Overall Height
Overall Depth (
excluding
rail)24" (610)
18" (457)
Shipping Weight (shell only)67–126 lbs
(30–57 kg)
Unit dimensions may vary to ±1/8" (3).
Pro wall chimney hood shown with (R) rail option.
I N S TA L L AT I O N S P E C I F I C A T I O N S
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
W O L F P R O W A L L C H I M N E Y V E N T I L A T I O N H O O D S
I N S TA L L AT I O N S P E C I F I C A T I O N S
The illustration and chart below provides
dimensions specific to each pro wall chimney
hood model. These dimensions are critical for
proper installation.
To reduce the risk of fire and electric
shock, install this ventilation hood only
with a blower manufactured by Wolf.
lower model numbers are listed on
B
page 17.
Pro Wall Chimney Hoods
Model(A)(B)(C)(D)
PWC362418(R)36" (914)18" (457)7" (178)9" (228)
PWC422418(R)42" (1067)24" (610)7" (178)12" (304)
PWC482418(R)48" (1219)30" (762)7" (178)15" (381)
PWC542418(R)54" (1372)36" (914)7" (178)18" (457)
Letters correspond to those in the illustrations.