The new generation of Wolf gas cooktops now offers a
36" contemporary gas cooktop. The cooking surface ts
ush to the countertop for a striking, low-prole look. Frontmounted controls integrate directly into cabinetry below.
With a choice of knob colors, the new contemporary gas
cooktop offers exceptional design exibility. Performance
enhancements make delicious results even more of a
certainty than ever.
A minimum 2" (51) is required from the bottom of the
cooktop to combustible materials. If the cooktop is installed
1
above an oven, a minimum of
/4" (6) is required between
units.
For the contemporary gas cooktop, the countertop must
be able to sustain temperatures up to 300°F
(149°C). Wolf
downdraft systems cannot be used with the contemporary
gas cooktop.
Control knobs for the contemporary gas cooktop are
designed to be mounted on the front face of cabinetry
below the unit. Mounting holes must be drilled through the
cabinet face. Refer to the illustration on the following page
for hole location.
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustration
on the following page. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
GAS SUPPLY
Installation must conform with all applicable gas codes.
3
A gas supply line of
the cooktop. If local codes permit, a certied, 3'
1
/2" (13) or 3/4" (19) ID exible metal appliance connector is
recommended to connect the units
/4" (19) rigid pipe must be provided to
(.9 m) long,
1
/2" NPT male inlet to
the gas supply line.
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
will function up to 8,600'
in altitude without adjustment and LP gas cooktops
(2621 m). If the installation exceeds
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GASWC
Supply Pressure5" (12.5 mb)
Min Line Pressure7" (17.5 mb)
Max Regulator Pressure14" (34.9 mb), .5 psi (3.5 kPa)
LP GASWC
Supply Pressure10" (25 mb)
Min Line Pressure11" (27.4 mb)
Max Regulator Pressure14" (34.9 mb), .5 psi (3.5 kPa)
ELECTRICAL REQUIREMENTS
Electrical Supplygrounded, 120 VAC, 60 Hz
Service15 amp dedicated circuit
Receptacle3-prong grounding-type
Power Cord6'
(1.8 m)
wolfappliance.com | 15
GAS COOKTOP
SIDE
NOTE:
combus
Ma
Outsid
36" Contemporary Gas Cooktop
FLUSH INSTALLATION
COUNTERTOP
PROFILE
1
/2"
(13) MAX
5
(2)
/64"
21"
(533) MIN
RECESS
(889)
35"
CUT-OUT WIDTH
36" (914) MIN
RECESS
COUNTERTOP CUT-OUT
21/2"
20"
(508)
(64)
13"
(330)
VIEW
Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
Wolf integrated modules have been redesigned to match
the updated lines of Sub-Zero and Wolf. Controls, grates
and trim allow them to integrate perfectly with their larger
counterparts and deliver equal performance.
Steamer and fryer modules require a method for draining
hot water and oil. For the steamer module, options include
5
connecting a drain hose from the
/8" (16) outlet tied into
an existing drain, a separate drain with freefall or placing a
heat-resistant receptacle under the drain outlet. For the fryer
module, the drain outlet must be accessible to drain oil into
a heat-resistant receptacle.
wolfappliance.com | 21
INTEGRATED MODULES
Planning Information
GAS SUPPLY
Installation must conform with all applicable gas codes.
3
A gas supply line of
/4" (19) rigid pipe must be provided
to the gas multifunction cooktop. If local codes permit, a
certied, 3'
(.9 m) long,
1
/2" (13) or 3/4" (19) ID exible metal
appliance connector is recommended to connect the units
1
/2" NPT male inlet to the gas supply line.
When multiple gas cooktops or modules are installed side
by side, they can receive their gas supply from a common
line. However, each unit must have its own regulator
installed between the mainline and the cooktop or module.
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
will function up to 8,600'
in altitude without adjustment and LP gas cooktops
(2621 m). If the installation exceeds
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GASWC
Supply Pressure5" (12.5 mb)
Min Line Pressure7" (17.5 mb)
Max Regulator Pressure14" (34.9 mb), .5 psi (3.5 kPa)
LP GASWC
Supply Pressure10" (25 mb)
Min Line Pressure11" (27.4 mb)
Max Regulator Pressure14" (34.9 mb), .5 psi (3.5 kPa)
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero,
Sub-Zero & Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, and Ingredients are registered trademarks and service marks
of Sub-Zero, Inc. All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.
LOCATION
26 | Wolf Customer Care 800.222.7820
FRONT VIEWSIDE VIEW
Wolf Appliance Residential Limited Warranty
FOR RESIDENTIAL USE
FULL TWO YEAR WARRANTY*
For two years from the date of original installation, this Wolf Appliance product warranty covers all parts
and labor to repair or replace, under normal residential use, any part of the product that proves to be
defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty
must be performed by Wolf factory certied service, unless otherwise specied by Wolf Appliance, Inc.
Service will be provided during normal business hours.
LIMITED FIVE YEAR WARRANTY
For ve years from the date of original installation, Wolf Appliance will repair or replace the following
parts that prove to be defective in materials or workmanship: gas burners (excludes appearance), electric
heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and
induction generators. If the owner uses Wolf factory certied service, the service provider will repair or
replace these parts with the owner paying for all other costs, including labor. If the owner uses non-certied service, the owner must contact Wolf Appliance, Inc. (using the information below) to receive repaired
or replacement parts. Wolf Appliance will not reimburse the owner for parts purchased from non-certied
service or other sources.
TERMS APPLICABLE TO EACH WARRANTY
The warranty applies only to products installed for normal residential use. The warranty applies only to
products installed in any one of the fty states of the United States, the District of Columbia or the ten
provinces of Canada. This warranty does not cover any parts or labor to correct any defect caused by
negligence, accident or improper use, maintenance, installation, service or repair.
THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE,
INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION
OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER
EXPRESS, IMPLIED OR STATUTORY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty gives you specic legal rights and you may also
have other legal rights that vary from state to state.
To receive parts and/or service and the name of Wolf factory certied service nearest you, contact Wolf
Appliance, Inc., P.O. Box 44848, Madison, WI 53744; check the contact & support section of our website,
wolfappliance.com, email us at customerservice@subzero.com or call 800-222-7820.
*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited
60-day parts and labor warranty for cosmetic defects.
*Replacement lters for ventilation hood recirculating kits are not covered by the product warranty.
WOLF APPLIANCE, INC. P.O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM 800.222.7820