Wolf CG365C/S, SM15/S, FM15/S, GM15/S, TM15/S Design Guide

...
Wolf New Generation Design Guide
REVISED 2/ 2016
12 | Wolf Customer Care 800.222.7820
Gas Cooktop
BUILT-IN OVENS COOKTOPS / COFFEE RANGES / RANGETOPS OUTDOOR GRILLS VENTILATION
The new generation of Wolf gas cooktops now offers a 36" contemporary gas cooktop. The cooking surface ts ush to the countertop for a striking, low-prole look. Front­mounted controls integrate directly into cabinetry below. With a choice of knob colors, the new contemporary gas cooktop offers exceptional design exibility. Performance enhancements make delicious results even more of a certainty than ever.
CONTEMPORARY
CG365C/S
wolfappliance.com | 13
Gas Cooktop
36" CONTEMPORARY
3515/16" (913)
7 (22)
2015/16"
(532)
63/4" (171)
/8"
BURNER RATING—Btu (kW)
36" CONTEMPORARY SIM HI
20K Burner 300 (.1) 20,000 (5.9) 12K Burner (2) 300 (.1) 12,000 (3.5)
9.2K Burner (2) 300 (.1) 9,200 (2.7)
VENTILATION OUTDOOR GRILLS RANGES / RANGETOPS COOKTOPS / COFFEE BUILT-IN OVENS
14 | Wolf Customer Care 800.222.7820
Planning Information
BUILT-IN OVENS COOKTOPS / COFFEE RANGES / RANGETOPS OUTDOOR GRILLS VENTILATION
A minimum 2" (51) is required from the bottom of the cooktop to combustible materials. If the cooktop is installed
1
above an oven, a minimum of
/4" (6) is required between
units.
For the contemporary gas cooktop, the countertop must be able to sustain temperatures up to 300°F
(149°C). Wolf
downdraft systems cannot be used with the contemporary gas cooktop.
Control knobs for the contemporary gas cooktop are designed to be mounted on the front face of cabinetry below the unit. Mounting holes must be drilled through the cabinet face. Refer to the illustration on the following page for hole location.
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustration on the following page. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
GAS SUPPLY
Installation must conform with all applicable gas codes.
3
A gas supply line of the cooktop. If local codes permit, a certied, 3'
1
/2" (13) or 3/4" (19) ID exible metal appliance connector is
recommended to connect the units
/4" (19) rigid pipe must be provided to
(.9 m) long,
1
/2" NPT male inlet to
the gas supply line.
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
will function up to 8,600'
in altitude without adjustment and LP gas cooktops
(2621 m). If the installation exceeds
these elevations, contact an authorized Wolf dealer for a high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb) Min Line Pressure 7" (17.5 mb) Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb) Min Line Pressure 11" (27.4 mb) Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6'
(1.8 m)
wolfappliance.com | 15
SIDE
NOTE: combus Ma Outsid
36" Contemporary Gas Cooktop
FLUSH INSTALLATION
COUNTERTOP
PROFILE
1
/2"
(13) MAX
5
(2)
/64"
21"
(533) MIN
RECESS
(889)
35"
CUT-OUT WIDTH
36" (914) MIN
RECESS
COUNTERTOP CUT-OUT
21/2"
20"
(508)
(64)
13"
(330)
VIEW
Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
ximum facade thickness 1" (25).
e corner radius 3/8" (10).
18"
(457)
9"
(229)
30"
(762)
5"
(127)
10"
(254)
C L
FRONT VIEW
3" (76) MIN–5" (127) MAX
(102)
4"
11/4" (32)
DIAMETER
E G
C L
VENTILATION OUTDOOR GRILLS RANGES / RANGETOPS COOKTOPS / COFFEE BUILT-IN OVENS
16 | Wolf Customer Care 800.222.7820
BUILT-IN OVENS COOKTOPS / COFFEE RANGES / RANGETOPS OUTDOOR GRILLS VENTILATION
wolfappliance.com | 17
INTEGRATED MODULES
Integrated Modules
BUILT-IN OVENS COOKTOPS / COFFEE RANGES / RANGETOPS OUTDOOR GRILLS VENTILATION
Wolf integrated modules have been redesigned to match the updated lines of Sub-Zero and Wolf. Controls, grates and trim allow them to integrate perfectly with their larger counterparts and deliver equal performance.
INTEGRATED MODULES
SM15/S Steamer
MM15/S Multifunction
FM15/S Fryer
GM15/S Grill
TM15/S Teppanyaki
wolfappliance.com | 19
INTEGRATED MODULES
Integrated Modules
STEAMER FRYER GRILL
7
(22)
/8"
15"
(381)
DRAIN
OUTLET
4"
(102)
21"
(533)
83/4"
(222)
7
(22)
/8"
15"
(381)
DRAIN
OUTLET
4"
(102)
21"
(533)
83/4"
(222)
MULTIFUNCTION
21"
(533)
15"
(381)
7
(22)
TEPPANYAKI
21"
(533)
15"
(381)
61/2"
(165)
/8"
7
(22)
/8"
21"
(533)
3" (76)
VENTILATION OUTDOOR GRILLS RANGES / RANGETOPS COOKTOPS / COFFEE BUILT-IN OVENS
15"
(381)
5" (127)
7
/8"
(22)
BURNER RATING—Btu (kW)
MULTIFUNCTION MAX
Burner 22,000 (6.5)
20 | Wolf Customer Care 800.222.7820
INTEGRATED MODULES
Planning Information
BUILT-IN OVENS COOKTOPS / COFFEE RANGES / RANGETOPS OUTDOOR GRILLS VENTILATION
A minimum 2" (51) is required from the bottom of the module to combustible materials.
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required.
When multiple cooktops or modules are installed side by side, each must have its own separate electrical supply.
ELECTRICAL REQUIREMENTS
ELECTRIC MODULES
Electrical Supply grounded 3-wire, 240/208 VAC, 60 Hz Steamer 15 amp dedicated circuit Fryer, Grill, Teppanyaki 20 amp dedicated circuit Conduit exible 4'
GAS MULTIFUNCTION
Electrical Supply grounded, 120 VAC, 60 Hz Service 15 amp dedicated circuit Receptacle 3-prong grounding-type Power Cord 6'
(1.2 m)
(1.8 m)
DRAIN OUTLET
Steamer and fryer modules require a method for draining hot water and oil. For the steamer module, options include
5
connecting a drain hose from the
/8" (16) outlet tied into an existing drain, a separate drain with freefall or placing a heat-resistant receptacle under the drain outlet. For the fryer module, the drain outlet must be accessible to drain oil into a heat-resistant receptacle.
wolfappliance.com | 21
INTEGRATED MODULES
Planning Information
GAS SUPPLY
Installation must conform with all applicable gas codes.
3
A gas supply line of
/4" (19) rigid pipe must be provided to the gas multifunction cooktop. If local codes permit, a certied, 3'
(.9 m) long,
1
/2" (13) or 3/4" (19) ID exible metal
appliance connector is recommended to connect the units
1
/2" NPT male inlet to the gas supply line.
When multiple gas cooktops or modules are installed side by side, they can receive their gas supply from a common line. However, each unit must have its own regulator installed between the mainline and the cooktop or module.
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
will function up to 8,600'
in altitude without adjustment and LP gas cooktops
(2621 m). If the installation exceeds
these elevations, contact an authorized Wolf dealer for a high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb) Min Line Pressure 7" (17.5 mb) Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb) Min Line Pressure 11" (27.4 mb) Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
VENTILATION OUTDOOR GRILLS RANGES / RANGETOPS COOKTOPS / COFFEE BUILT-IN OVENS
22 | Wolf Customer Care 800.222.7820
INTEGRATED MODULES
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
FRONT VIEWSIDE VIEW
COUNTERTOP CUT-OUT
13"
(330)
18"
(457)
7"
(178)
E
30"
(762)
75/8"
(194)
6"
(152)
123/8"
(314)
DRAIN
OUTLET
191/2"
(495)
21/2" (64) min
21/2" (64) min
14"
(356)
Steamer Module
STANDARD INSTALLATION
BUILT-IN OVENS COOKTOPS / COFFEE RANGES / RANGETOPS OUTDOOR GRILLS VENTILATION
WARNING
The steamer module must be installed at least 15" (381) from a fryer module.
wolfappliance.com | 23
INTEGRATED MODULES
FRONT VIEWSIDE VIEW
COUNTERTOP CUT-OUT
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
13"
(330)
18"
(457)
7"
(178)
E
30"
(762)
75/8"
(194)
6"
(152)
123/8"
(314)
DRAIN
OUTLET
191/2"
(495)
21/2"
(64) min
21/2"
(64) min
14"
(356)
Fryer Module
STANDARD INSTALLATION
WARNING
The fryer module must be installed at least 15" (381) from any open-ame cooking device or a steamer module.
VENTILATION OUTDOOR GRILLS RANGES / RANGETOPS COOKTOPS / COFFEE BUILT-IN OVENS
24 | Wolf Customer Care 800.222.7820
INTEGRATED MODULES
191/2"
(495)
21/2" (64) min
21/2" (64) min
FRONT VIEWSIDE VIEW
COUNTERTOP CUT-OUT
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
13"
(330)
18"
(457)
7"
(178)
30"
(762)
E
14"
(356)
Grill and Teppanyaki Modules
STANDARD INSTALLATION
BUILT-IN OVENS COOKTOPS / COFFEE RANGES / RANGETOPS OUTDOOR GRILLS VENTILATION
wolfappliance.com | 25
INTEGRATED MODULES
Multifunction Cooktop
STANDARD INSTALLATION
21/2" (64)
13"
(330)
18"
(457)
14"
(356)
COUNTERTOP CUT-OUT
30"
(762)
7"
(178)
E G
191/2"
(495)
21/2" (64)
ELECTRICAL
AND GAS FLOOR
VENTILATION OUTDOOR GRILLS RANGES / RANGETOPS COOKTOPS / COFFEE BUILT-IN OVENS
5"
(127)
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero, Sub-Zero & Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, and Ingredients are registered trademarks and service marks of Sub-Zero, Inc. All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.
LOCATION
26 | Wolf Customer Care 800.222.7820
FRONT VIEWSIDE VIEW
Wolf Appliance Residential Limited Warranty
FOR RESIDENTIAL USE
FULL TWO YEAR WARRANTY*
For two years from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certied service, unless otherwise specied by Wolf Appliance, Inc. Service will be provided during normal business hours.
LIMITED FIVE YEAR WARRANTY
For ve years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: gas burners (excludes appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction generators. If the owner uses Wolf factory certied service, the service provider will repair or replace these parts with the owner paying for all other costs, including labor. If the owner uses non-certi­ed service, the owner must contact Wolf Appliance, Inc. (using the information below) to receive repaired or replacement parts. Wolf Appliance will not reimburse the owner for parts purchased from non-certied service or other sources.
TERMS APPLICABLE TO EACH WARRANTY
The warranty applies only to products installed for normal residential use. The warranty applies only to products installed in any one of the fty states of the United States, the District of Columbia or the ten provinces of Canada. This warranty does not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair.
THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE, INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDEN­TAL DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specic legal rights and you may also have other legal rights that vary from state to state.
To receive parts and/or service and the name of Wolf factory certied service nearest you, contact Wolf Appliance, Inc., P.O. Box 44848, Madison, WI 53744; check the contact & support section of our website, wolfappliance.com, email us at customerservice@subzero.com or call 800-222-7820.
*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty for cosmetic defects.
*Replacement lters for ventilation hood recirculating kits are not covered by the product warranty.
WOLF APPLIANCE, INC. P.O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM 800.222.7820
Loading...