Drawer Microwave Oven Installation Guide
DRAWER MICROWAVE OVEN
Contents
3 Drawer Microwave Oven
4 Specications
7 Installation
7 Troubleshooting
Features and specications are subject to change at any
time without notice. Visit wolfappliance.com/specs for the
most up-to-date information.
Important Note
To ensure this product is installed and operated as safely
and efciently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
IMPORTANT NOTE: Save these instructions for the local
electrical inspector.
SAVE THESE INSTRUCTIONS
2 | Wolf Customer Care 800.222.7820
DRAWER MICROWAVE OVEN
Product Information
Important product information including the model and
serial number are listed on the product rating plate. The
rating plate is located on the bottom of the microwave oven
cavity. The drawer must be open to view the rating plate.
Refer to the illustration below.
If service is necessary, contact Wolf factory certied service
with the model and serial number. For the name of the
nearest Wolf factory certied service or for questions
regarding the installation, visit the contact & support section
of our website, wolfappliance.com or call Wolf customer
care at 800-222-7820.
RATING
PLATE
IMPORTANT NOTE: When using any microwave oven gener-
ating heat, there are certain safety precautions you should
follow. These precautions are listed in the Wolf drawer
microwave oven use & care guide provided with the unit.
Read all and follow carefully.
WARNING
If the information in this guide is not followed exactly,
a re or electrical shock may result that could cause
property damage, personal injury or death.
WARNING
To reduce the risk of tipping, the drawer microwave
oven must be secured by properly installed anti-tip
blocking.
This microwave oven must be electrically grounded in
accordance with local codes.
Make sure the wall coverings and the cabinets around
the appliance can withstand the heat generated by a
microwave oven.
Rating plate location.
WARNING
Improper use of the grounding plug can result in a risk
of electric shock. Do not use an extension cord. If the
power cord is too short, have a qualied electrician or
service technician install an outlet near the appliance.
wolfappliance.com | 3
SPECIFICATIONS
Installation Requirements
The drawer microwave oven can be installed in a standard
or ush inset application. Location of the electrical supply
within the oven opening may require additional cabinet
depth.
Finish the edges of the opening. They may be visible when
the drawer is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
1
For ush inset installations, a minimum
required on the top and sides and
To ensure consistent reveals, each corner of the opening
must be exactly 90°. A sales accessory is required to direct
air away from the unit. Accessories are available through an
authorized Wolf dealer. For local dealer information, visit the
nd a showroom section of our website, wolfappliance.com.
ANTI-TIP BLOCKING
To reduce the risk of tipping, the drawer microwave oven
must be secured in place by anti-tip blocking. The anti-tip
blocking must be provided by the installer. Dimensions will
vary with the installation. Refer to the illustrations on the
following pages.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
24" Model 125 lb (57 kg)
30" Model 125 lb (57 kg)
TRIM OVERLAP 24" MODEL 30" MODEL
Top
Bottom
Sides
/8" (3) reveal is
11
/16" (18) on the bottom.
5
/16" (8)
1
/16" (2)
7
/8" (22) 37/8" (98)
5
/16" (8)
1
/16" (2)
Electrical
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on
the following pages. The receptacle may also be located
in an adjacent cabinet within reach of the power cord. A
separate circuit, servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) is not recommended
and may cause interruption of operation. Refer to the illustration below for minimum power cord plug clearance.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 4'
GROUNDING INSTRUCTIONS
This appliance must be grounded. The microwave oven
is equipped with a cord having a grounding wire with a
grounding plug. It must be plugged into a wall receptacle
that is properly installed and grounded in accordance with
the National Electrical Code and local codes and ordinances. In the event of an electrical short circuit, grounding
reduces risk of electric shock by providing an escape wire
for the electric current.
(1.2 m)
RATING
PLATE
4 | Wolf Customer Care 800.222.7820
MINIMUM CORD
CLEARANCE
Power cord clearance.
3"
(76)
Rating plate location.
SPECIFICATIONS
NOTE: All dr
Dashed line represents profile of unit
Drawer Microwave Oven
STANDARD INSTALLATION
22" (559)
OPENING
DEPTH
TOP VIEW
ANTI-TIP BLOCK
VIEW
awer microwave ovens require the same opening dimensions.
OPENING WIDTH
DRAWER MICROWAVE W
24" Model 221/8" (562)
30" Model 221/8" (562)
143/4" (375)
OPENING
HEIGHT
.
E
W
OPENING WIDTH
FRONT VIEW
wolfappliance.com | 5
SPECIFICATIONS
NOTE: Dashed line represents profile of unit.
Drawer Microwave Oven
FLUSH INSET INSTALLATION
11/4" (32)
231/4"
FLUSH INSET
TOP VIEW
DEPTH
(591)
FINISHED
CLEATS*
ANTI-TIP BLOCK
VIEW
ill be visible and should be finished to match cabinetry.
FLUSH INSET WIDTH
DRAWER MICROWAVE W A
24" Model 241/8" (613) 1" (25)
30" Model 301/8" (765) 4" (102)
1515/16"
FLUSH INSET
HEIGHT
(405)
7
E
A
3
FLUSH INSET WIDTH
FRONT VIEW
/16"(11)
/4" (19)
W
6 | Wolf Customer Care 800.222.7820