Wolf LinkEx LX-400SL../T4/..24V Series, LinkEx LX-400SH../T4/..230V Series, LinkEx LX-400SH../T4/..110V Series, LinkEx LX-400SL../T4/..48V Series Operation And Maintenance Instructions

Page 1
Wolf LinkExTM LED Temporary Luminaire
Operation and Maintenance Instructions
Please Retain – Read Before Use
EU Declaration of Conformity
The Wolf LinkEx™ LED Temporary Luminaire (LX-400) meets all relevant provisions of the 2014/34/EU Explosive Atmospheres (ATEX Equipment) Directive by virtue of the issued EU type examination certificate, demonstrating compliance with all relevant harmonised standards and essential health and safety requirements. The Wolf LinkEx™ LED Temporary Luminaire is a leadlamp with a durable enclosure construction of polycarbonate with polyurethane protective rings. Models are available in a variety of input voltages. Approved as Group II, Category 2 equipment for use in zone 1 & 2 potentially explosive gases, vapours, mists and dusts where the T4 temperature class/135ºC maximum surface temperature permits.
Certification/Approval code:
II 2 GD
Ex eb mb op is IIC T4 Gb (-20ºC Ta +55ºC) Ex tb op is IIIC T135ºC Db IP67*
EU Type examination certificate: SIRA12ATEX3177X
Notified body: Baseefa Ltd. Rockhead Business Park,
Notified body number: 1180
Harmonised standards applied: EN60079-0:2012 + A11:2013, EN60079-7:2015, EN60079-18:2015, EN60079-31:2014, EN60079-28:2015.
Ingress protection level IP67* to EN60529:1992
The Wolf LinkEx™ LED Temporary Luminaire is certified compliant with the 2014/30/EU EMC Directive. To the following harmonised standards BS EN 50015:2013, BS EN 61000-3-2: 2006 +A2:2009, BS EN 61000-3-3: 2013 and BS EN 61547: 2009
IECEx Scheme Certification
Certificate number: IECEx SIR 12.0070X
Certification/Approval code: Ex eb mb op is IIC T4 Gb (-20ºC Ta +55ºC) Ex tb op is IIIC T135ºC Db IP67*
Standards applied: IEC60079-0:2011, IEC60079-7:2015, IEC60079-18:2014, IEC60079-31:2013, IEC60079-28:2015.
Ingress protection level IP67* to IEC60529:1992
*Some variants of plugs/sockets may reduce the IP (Ingress Protection) rating. e.g. ATX and CEAG IP66, Stahl Sockets IP54 rated.
IMPORTANT: SPECIAL CONDITIONS OF USE (X)
1. The user/installer shall ensure that, when the Luminaire is fitted with a previously certified plug that has associated special conditions for safe use, they shall take into account any restrictions or conditions for safe use that are applicable to these devices.
2. Linkable luminaires fitted with Marechal sockets are certified for low impact risk use only, do not expose to shocks greater than 4 joules.
EQUIPMENT USE
1. Read this document carefully before first use of the Wolf LinkEx™ LED Temporary Luminaire and retain for future reference.
2. Check the rating label to ensure the Wolf LinkEx™ LED Temporary Luminaire is suitable for the supply provided, ambient temperature present and the environmental conditions.
3. In areas where processes that induce circulating currents in the earth system are being undertaken, such as electric welding, it is the user’s responsibility to ensure there is no potential difference between the supply earth and the earth local to the luminaire. If a potential difference exists there is a risk of arcing should the luminaires end cap fixings or metal gland come into contact with local metal work. In these situations, the luminaire should also be locally earth bonded with a flexible cable, no longer than 2 meters, with a conductor area of 6mm2 minimum. The luminaire must be de-energised during connection or disconnection of the local earth bond. An external Earth Bonding Stud is available in the spares list and can be retro fitted in place of one of the end cap retaining screws.
4. Safe Operating Voltage Indicator (SOVI). The Wolf LinkEx™ LED Temporary Luminaire incorporates SOVI technology to highlight to the user if the product is operating outside of the certified maximum and recommended minimum voltage range.
The LX-400SH../T4/. 110/230 versions operating over 264V AC will pulse dim the light. The luminaire must not be used over this voltage. When operating below 90V AC** the dimmed light will pulse brighten. **The light output reduces incrementally as the supply voltage falls below 100V AC. The luminaire will shut down if the supply voltage continues to fall. The LX-400SL../T4/. 24/48 versions operating over 50V AC/DC will pulse dim the light. The luminaire must not be used over this voltage. When operating below 18V AC/DC*** the dimmed light will pulse brighten.
Staden Lane, Buxton, SK17 9RZ, UK
Alex Jackson – Managing Director, Wolf Safety Lamp Company Ltd.
***The light output reduces incrementally as the input voltage falls below 19V AC/DC. The luminaire will shut down if the supply voltage continues to fall. If connecting a large number of luminaires check for SOVI indication on all the lamps in the string. Guidance on lamp connection and extensions can be found at
www.wolf-safety.co.uk
5. The Wolf LinkEx™ LED Temporary Luminaire enclosure is constructed from polycarbonate parts, check Ex area for potential contact to corrosive and/or aggressive substances.
6. The Wolf LinkEx™ LED Temporary Luminaire is class 1 earthed electrical equipment, using 3 core cable.
7. Ex e terminal blocks must have all terminals fully tightened down even if a conductor is not fitted. On the six way terminal block, tighten screws to 0.6Nm, on the 4 way terminal block tighten to 1.8Nm.
8. ATEX/IECEx certified cable glands must be used and be suitable for the type of cable used.
9. Ensure cable is rated for the ambient temperature the Wolf LinkEx™ LED Temporary Luminaire will be used in, standard SY cable is not rated for use below -5ºC.
10. Inspect cable for damage at regular intervals.
11. Damaged equipment should be withdrawn and repaired as necessary before being put back in to service, in accordance with EN60079-17.
12. Luminaires must not be opened in Hazardous Areas.
13. When the Wolf LinkEx™ LED Temporary Luminaire is used in temporary installations two mounting points must be used, see Wolf bracket fixing kits and associated accessories.
14. The Wolf LinkEx™ LED Temporary Luminaire can be carried whilst energised/illuminated.
MAINTENANCE
1. Isolate the Wolf LinkEx™ LED Temporary Luminaire from the power supply before carrying out any maintenance work.
2. To replace LED strip, replace entire tray (see spares list).
3. External plastic components have an anti static coating. Use only a dilute water/ detergent mix to clean.
4. IMPORTANT. No modifications are permitted to the Wolf LinkEx™ LED Temporary Luminaire, all spare parts must be purchased from the manufacturer, unauthorized modifications or spare parts will invalidate certification.
5. Insulation testing must be carried out to IEC, EN standards to the correct rating i.e. 250V DC for 24/48V versions and 500V DC for 110/230VAC versions, Live and neutral cables must be shorted together and the voltage applied between earth and this connection.
ELECTRICAL DATA
MODEL SOVI Range Freq Hz POWER WATT VA
LX-400SL../T4/..24V
LX-400SL../T4/..48V
LX-400SH.. /T4/..110V 90-264VAC 50/60 30.5 31.2
LX-400SH.. /T4/..230V 90-264VAC 50/60 27.6 28.5
CHANGING CABLE OR SOCKETS
See attached diagrams.
Remove the two securing screws from the cable entry end cap, remove end cap. Disconnect the input cable. To remove the enclosure tube, slide tube over the tray assembly. With the tube removed the blank cap (non linkable Luminaire) or socket and cap (linkable Luminaire) can be removed by removing the two internal screws; care must be taken to retain the sealing washers fitted to the screws and dome nuts. If required the socket cap can then be removed, if the socket is replaced ensure correct sealing washers are used. Re-assembly is the reverse procedure. Take care not to trap/crush wires, ensure all seals are present and in good condition.
FAULT FINDING
If a Wolf LinkEx™ LED Temporary Luminaire fails to function, check input cable continuity and terminations. If satisfactory, test the output fuse to each LED strip. Only replace with Wolf encapsulated fuse of the correct rating. On 24/48V versions replace all fuses to LED strips if either has failed.
SPARE PARTS LIST
See attached diagram.
DISPOSAL OF WASTE MATERIAL
Disposal of packaging, LinkEx™ LED Temporary Luminaire products, old LED trays and electronics should be carried out in accordance with national regulations. (WEEE)
The Wolf Safety Lamp Co. Ltd has a policy of continuous product improvement. Changes in design details may be made without prior notice.
Prices and design are subject to alteration without notice. All products sold are subject to our conditions of sale. A copy of these instructions with any relevant revisions can be found at www.wolf-safety.co.uk
18-50VAC 50/60 27.1 41.2
18-50VDC 27.1
18-50VAC 50/60 26.9 51.2
18-50VDC 26.9
WOLF SAFETY LAMP COMPANY
Saxon Road Works, Sheffield, S8 0YA, England
Tel: +44 114 255 1051 Fax: +44 114 255 7988
E-mail: info@wolf-safety.co.uk Website: www.wolf-safety.co.uk
Page 2
Wolf LinkEx™ LED Temporary Luminaire (LX-400)
CEAG
STAHL
ATX
9
13
6 7 8
25
4
1
3
2
21
17
20
4
1
4
23
24
25
5
2
25
4
10 11 12
14 15 16
180o Version
360o Version
17
26
22
18
19
(24/48V)
(110/230V)
18
19
(24/48V)
(110/230V)
27
28
Exploded View 180o and 360o Variants
Page 3
TM
Wolf LinkEx
LED Temporary Luminaire
LinkEx LED
Parts List
Item No. Part No: Spare Part Description Quantity required per lamp
180o Models 360o Models
1 LX-602 Bump Ring (pack of 2) 1 1
2 LX-304 Tube Seal Ring (pair) 1 1
3 LX-370 Tube 1 1
4 LX-622 Cap Seal 5mm and Tube Seal 10mm 1 1
(1 off of each for each end of the lamp)
5 LX-306 Cable Entry End Cap 1 1
6 LX-312 ATX Socket End Cap 1 1
7 LX-314 Stahl Socket End Cap 1 1
8 LX-310 CEAG Socket End Cap 1 1
9 LX-316 Blank End Cap Non Link 1 1
10 LX-1044 CEAG Socket 110V 1 1
11 LX-1045 CEAG Socket 230V 1 1
12 LX-1043 CEAG Socket 24V 1 1
13 LX-1047 Stahl Socket 110V 1 1
14 LX-1050 ATX Socket 110V 1 1
15 LX-1051 ATX Socket 230V 1 1
16 LX-1049 ATX Socket 24V 1 1
17 LX-684 Ex e 6 Way Weidmuller Terminal Block and 1 1
Screws M3x20, LED Output
18 LX-624 24/48V LED Driver and Fittings 1 1
19 LX-640 110/230V LED Driver and Fittings 1 1
20 LX-618 180° LED Strip Assembly and Tray 1
21 LX-636 360° LED Top Tray Assembly 1
22 LX-637 360° LED Bottom Tray Assembly and Fittings 1
23 LL-311 Trumpet Gland 1 1
24 LX-408 Gland Nut 1
25 LX-658 Dowty Seals M6, M6x30 Screws, M5 Dome nuts, 1 1
M5 Dowty Seals and M5x12 Cap Heads (2 of each)
26 LX-656 Weidmuller MK6 4 Way Terminal Block 1 1
and Screws M3x22 and Backing Plate, Cable Input
27 LX-680 Magnet bracket Kit (pack of 2) 1 1
28 LX-1258 M6 External Earth Bonding Stud 1 1
Items not shown on the exploded view diagram
LX-691 1 Amp LED Fuse (pack of 2) 1 1
LX-654 Hanging / Shoulder Strap (pack of 2) 1 1
LX-545/3 Protective Film (pack of 3) 1 1
WOLF SAFETY LAMP COMPANY
Saxon Road Works, Sheffield, S8 0YA, England
Tel: +44 114 255 1051 Fax: +44 114 255 7988
E-mail: info@wolf-safety.co.uk Website: www.wolf-safety.co.uk
LX-507 Issue 2