Wolf CG365C/S, SM15/S, FM15/S, GM15/S, TM15/S Design Guide

...
Wolf New Generation Design Guide
REVISED 2/ 2016
12 | Wolf Customer Care 800.222.7820
Gas Cooktop
BUILT-IN OVENS COOKTOPS / COFFEE RANGES / RANGETOPS OUTDOOR GRILLS VENTILATION
The new generation of Wolf gas cooktops now offers a 36" contemporary gas cooktop. The cooking surface ts ush to the countertop for a striking, low-prole look. Front­mounted controls integrate directly into cabinetry below. With a choice of knob colors, the new contemporary gas cooktop offers exceptional design exibility. Performance enhancements make delicious results even more of a certainty than ever.
CONTEMPORARY
CG365C/S
wolfappliance.com | 13
Gas Cooktop
36" CONTEMPORARY
3515/16" (913)
7 (22)
2015/16"
(532)
63/4" (171)
/8"
BURNER RATING—Btu (kW)
36" CONTEMPORARY SIM HI
20K Burner 300 (.1) 20,000 (5.9) 12K Burner (2) 300 (.1) 12,000 (3.5)
9.2K Burner (2) 300 (.1) 9,200 (2.7)
VENTILATION OUTDOOR GRILLS RANGES / RANGETOPS COOKTOPS / COFFEE BUILT-IN OVENS
14 | Wolf Customer Care 800.222.7820
Planning Information
BUILT-IN OVENS COOKTOPS / COFFEE RANGES / RANGETOPS OUTDOOR GRILLS VENTILATION
A minimum 2" (51) is required from the bottom of the cooktop to combustible materials. If the cooktop is installed
1
above an oven, a minimum of
/4" (6) is required between
units.
For the contemporary gas cooktop, the countertop must be able to sustain temperatures up to 300°F
(149°C). Wolf
downdraft systems cannot be used with the contemporary gas cooktop.
Control knobs for the contemporary gas cooktop are designed to be mounted on the front face of cabinetry below the unit. Mounting holes must be drilled through the cabinet face. Refer to the illustration on the following page for hole location.
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustration on the following page. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
GAS SUPPLY
Installation must conform with all applicable gas codes.
3
A gas supply line of the cooktop. If local codes permit, a certied, 3'
1
/2" (13) or 3/4" (19) ID exible metal appliance connector is
recommended to connect the units
/4" (19) rigid pipe must be provided to
(.9 m) long,
1
/2" NPT male inlet to
the gas supply line.
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
will function up to 8,600'
in altitude without adjustment and LP gas cooktops
(2621 m). If the installation exceeds
these elevations, contact an authorized Wolf dealer for a high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb) Min Line Pressure 7" (17.5 mb) Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb) Min Line Pressure 11" (27.4 mb) Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6'
(1.8 m)
wolfappliance.com | 15
SIDE
NOTE: combus Ma Outsid
36" Contemporary Gas Cooktop
FLUSH INSTALLATION
COUNTERTOP
PROFILE
1
/2"
(13) MAX
5
(2)
/64"
21"
(533) MIN
RECESS
(889)
35"
CUT-OUT WIDTH
36" (914) MIN
RECESS
COUNTERTOP CUT-OUT
21/2"
20"
(508)
(64)
13"
(330)
VIEW
Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
ximum facade thickness 1" (25).
e corner radius 3/8" (10).
18"
(457)
9"
(229)
30"
(762)
5"
(127)
10"
(254)
C L
FRONT VIEW
3" (76) MIN–5" (127) MAX
(102)
4"
11/4" (32)
DIAMETER
E G
C L
VENTILATION OUTDOOR GRILLS RANGES / RANGETOPS COOKTOPS / COFFEE BUILT-IN OVENS
16 | Wolf Customer Care 800.222.7820