Features and specications are subject to change at any
time without notice. Visit wolfappliance.com/specs for the
most up-to-date information.
Throughout this guide, dimensions may vary by ±
1
/8" (3).
Dimensions in parentheses are millimeters unless otherwise
specied.
Page 3
M SERIES OVENS
wolfappliance.com | 3
Page 4
UPPER OVENLOWER OVEN
M SERIES OVENS
M Series Built-In Ovens
Four striking new looks are just the beginning. Contemporary M series ovens include stainless steel and black glass
models. Superior performance features include a more
advanced dual vertical convection fan system, touchscreen controls, convenient preset cooking programs, and
improved interior lighting. There is more usable space inside
for deliciousness on a grand scale. M series ovens can be
installed in a standard or ush inset application.
M SERIES OVENS
TRANSITIONAL
SO30TM/S/TH
DO30TM/S/TH
PROFESSIONAL
SO30PM/S/PH
DO30PM/S/PH
CONTEMPORARY
4 | Wolf Customer Care 800.222.7820
SO30CM/S
DO30CM/S
SO30CM/B
DO30CM/B
Page 5
M SERIES OVENS
30" M Series Built-In Ovens
TRANSITIONAL SINGLE OVEN
281/2"
(723)
297/8" (759)
21/2"
(65)
TRANSITIONAL DOUBLE OVEN
7
/8"
(22)
2" (51)
13/8"
CONDUIT
CHANNEL
23" (584)
BEHIND FRAME
7
/8"
(22)
2" (51)
13/8"
CONDUIT
CHANNEL
(36)
(36)
85/8"
(218)
85/8"
(218)
27"
(686)
17/8"
(46)
OPEN OVEN DOOR
17/8"
(46)
213/8"
(543)
297/8" (759)
507/8"
(1291)
21/2"
(65)
23" (584)
BEHIND FRAME
493/8"
(1254)
OPEN OVEN DOOR
213/8"
(543)
wolfappliance.com | 5
Page 6
M SERIES OVENS
30" M Series Built-In Ovens
PROFESSIONAL SINGLE OVEN
281/2"
(723)
297/8" (759)
31/4"
(83)
PROFESSIONAL DOUBLE OVEN
UPPER OVENLOWER OVEN
7
/8"
(22)
2" (51)
13/8"
CONDUIT
CHANNEL
23" (584)
BEHIND FRAME
7
/8"
(22)
2" (51)
13/8"
CONDUIT
CHANNEL
(36)
(36)
85/8"
(218)
85/8"
(218)
27"
(686)
17/8"
(46)
OPEN OVEN DOOR
17/8"
(46)
213/8"
(543)
297/8" (759)
507/8"
(1291)
31/4"
(83)
23" (584)
BEHIND FRAME
493/8"
(1254)
OPEN OVEN DOOR
213/8"
(543)
6 | Wolf Customer Care 800.222.7820
Page 7
M SERIES OVENS
30" M Series Built-In Ovens
CONTEMPORARY STAINLESS STEEL SINGLE OVEN
7
(22)
/8"
85/8"
(218)
2" (51)
(36)
13/8"
297/8" (759)
281/2"
(723)
CONDUIT
CHANNEL
23" (584)
BEHIND FRAME
27"
(686)
CONTEMPORARY STAINLESS STEEL DOUBLE OVEN
7
(22)
2" (51)
/8"
(36)
13/8"
CONDUIT
CHANNEL
85/8"
(218)
17/8"
(46)
OPEN OVEN DOOR
17/8"
(46)
213/8"
(543)
297/8" (759)
507/8"
(1291)
23" (584)
BEHIND FRAME
493/8"
(1254)
OPEN OVEN DOOR
213/8"
(543)
wolfappliance.com | 7
Page 8
M SERIES OVENS
30" M Series Built-In Ovens
CONTEMPORARY BLACK GLASS SINGLE OVEN
(25)
1"
85/8"
(218)
2" (51)
(36)
13/8"
CONDUIT
CHANNEL
23" (584)
BEHIND FRAME
297/8" (759)
281/2"
(723)
CONTEMPORARY BLACK GLASS DOUBLE OVEN
(36)
13/8"
CONDUIT
CHANNEL
85/8"
(218)
(25)
2" (51)
1"
27"
(686)
17/8"
(46)
OPEN OVEN DOOR
17/8"
(46)
213/8"
(543)
297/8" (759)
507/8"
(1291)
23" (584)
BEHIND FRAME
493/8"
(1254)
OPEN OVEN DOOR
213/8"
(543)
8 | Wolf Customer Care 800.222.7820
Page 9
M SERIES OVENS
Planning Information
The M series oven can be installed in a standard or ush
inset application. If a cooktop is being installed above an
1
oven, a minimum of
/4" (6) is required between the units.
The location of the electrical supply within the oven opening
may require additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
1
For ush inset installations, a minimum
/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORTMIN
Single Oven250 lb (115 kg)
Double Oven400 lb (181 kg)
TRIM OVERLAP
Top1" (25)
Bottom0" (0)
Sides
11
/16" (18)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply ush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the oven can be placed in an adjacent cabinet
within reach of the conduit.
Performance may be compromised if the electrical supply is
less than 240 volts.
The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground conductor.
The wiring diagram covering the control circuit is provided
with the oven.
ELECTRICAL REQUIREMENTS—SINGLE OVEN
Electrical Supplygrounded, 240/208 VAC, 60 Hz
Service30 amp dedicated circuit
Conduit4'
Total Amps22
Max Connected Load5.4 kW
(1.2 m)
DUAL INSTALLATION
Two 30" single M series ovens can be installed side by side
in a standard or ush inset application. A dual installation kit
is required. To maintain appropriate airow, the ovens must
be installed into one opening. Any cosmetic or structural
material placed between the ovens will impede airow and
is not recommended. Refer to the illustrations on pages
14–15.
The dual installation kit is available through an authorized
Wolf dealer. For local dealer information, visit the nd a
showroom section of our website, wolfappliance.com.
ELECTRICAL REQUIREMENTS —DOUBLE OVEN
Electrical Supplygrounded, 240/208 VAC, 60 Hz
Service50 amp dedicated circuit
Conduit5'
Total Amps45
Max Connected Load10.8 kW
(1.5 m)
wolfappliance.com | 9
Page 10
SIDE
NOTE: Location of electrical supply within opening may require additional cabinet depth.
M SERIES OVENS
30" M Series Single Oven
STANDARD INSTALLATION
231/4" (591)
TOP VIEW
OPENING
DEPTH
VIEW
271/2"
(699)
OPENING
HEIGHT
281/2" (724)
OPENING WIDTH
FRONT VIEW
5"
(127)
E
4"
(102)
E
E
10 | Wolf Customer Care 800.222.7820
Page 11
*1
**
**
NOTE: Location of electrical supply within opening may require additional cabinet depth.
SIDE
M SERIES OVENS
30" M Series Single Oven
FLUSH INSET INSTALLATION
283/4"
(730)
FLUSH INSET
HEIGHT***
7
(22)
/8"
OR
(25)**
1"
FLUSH INSET WIDTH***
24" (610)
FLUSH INSET
TOP VIEW
301/8" (765)
DEPTH
11/8" (29)
13
/16" (21)
1
/8" (3)
5"
(127)
E
4"
(102)
E
FINISHED
CLEATS*
E
VIEW
" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
7
/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model.
*Dimension provides minimum reveals.
FRONT VIEW
wolfappliance.com | 11
Page 12
SIDE
NOTE: Location of electrical supply within opening may require additional cabinet depth.
M SERIES OVENS
30" M Series Double Oven
STANDARD INSTALLATION
231/4" (591)
TOP VIEW
OPENING
DEPTH
VIEW
497/8"
(1267)
OPENING
HEIGHT
17" (432)
TYPICAL
281/2" (724)
OPENING WIDTH
FRONT VIEW
5"
(127)
E
4"
(102)
E
E
12 | Wolf Customer Care 800.222.7820
Page 13
*1
**
**
NOTE: Location of electrical supply within opening may require additional cabinet depth.
SIDE
M SERIES OVENS
30" M Series Double Oven
FLUSH INSET INSTALLATION
511/8"
(1299)
FLUSH INSET
HEIGHT***
7
(22)
/8"
OR
(25)**
1"
FLUSH INSET WIDTH***
24" (610)
FLUSH INSET
TOP VIEW
301/8" (765)
DEPTH
11/8" (29)
13
/16" (21)
5"
(127)
E
4"
(102)
FINISHED
CLEATS*
E
(432)
17"
TYPICAL
VIEW
" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
7
/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model.
*Dimension provides minimum reveals.
1
/8" (3)
FRONT VIEW
E
wolfappliance.com | 13
Page 14
SIDE
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required fo
M SERIES OVENS
30" M Series Single Oven
DUAL STANDARD INSTALLATION
TOP VIEW
231/4" (591)
OPENING
DEPTH
VIEW
271/2"
(699)
OPENING
HEIGHT
5"
E
(127)
4"
(102)
581/2" (1486)
OPENING WIDTH
EE
FRONT VIEW
r this installation.
5"
(127)
E
4"
(102)
14 | Wolf Customer Care 800.222.7820
Page 15
SIDE
*1
**
**
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required fo
M SERIES OVENS
30" M Series Single Oven
DUAL FLUSH INSET INSTALLATION
283/4"
(730)
FLUSH INSET
HEIGHT***
7
1"
13
/16" (21)
(22)
/8"
OR
(25)**
11/8" (29)
1
/8" (3)
TOP VIEW
601/8" (1527)
FLUSH INSET WIDTH***
5"
E
(127)
4"
(102)
24" (610)
FLUSH INSET
DEPTH
5"
(127)
(102)
FINISHED
CLEATS*
E
4"
EE
VIEW
" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
7
/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model.
*Dimension provides minimum reveals.
FRONT VIEW
r this installation.
wolfappliance.com | 15
Page 16
E SERIES OVENS
16 | Wolf Customer Care 800.222.7820
Page 17
E SERIES OVENS
E Series Built-In Ovens
Wolf E series ovens are crafted of stainless steel. The
handles match the rest of the new Wolf cooking appliance
offering, providing a more cohesive look. E series ovens can
be installed in a standard or ush inset application.
E SERIES OVENS
TRANSITIONAL
SO24TE/S/TH
PROFESSIONAL
SO30PE/S/PH
CONTEMPORARY
SO30TE/S/TH
DO30TE/S/TH
DO30PE/S/PH
SO30CE/B/TH
DO30CE/B/TH
wolfappliance.com | 17
Page 18
E SERIES OVENS
24" E Series Built-In Oven
TRANSITIONAL SINGLE OVEN
7
(22)
/8"
22"
(559)
231/2"
(597)
231/2"
(597)
21/2"
(64)
211/2" (546)
BEHIND FRAME
231/4"
(591)
OPEN OVEN DOOR
181/8"
(460)
18 | Wolf Customer Care 800.222.7820
Page 19
E SERIES OVENS
30" E Series Built-In Ovens
TRANSITIONAL SINGLE OVEN
1" (25)
277/8"
(708)
297/8"
(759)
23/4"
(70)
TRANSITIONAL DOUBLE OVEN
1" (25)
503/8"
(1280)
(76)
3"
CONDUIT
CHANNEL
233/4" (603)
BEHIND FRAME
(76)
3"
CONDUIT
CHANNEL
271/8"
(689)
495/8"
(1261)
87/8"
(225)
281/4"
(718)
OPEN OVEN DOOR
87/8"
(225)
281/4"
(718)
95/8"
(244)
95/8"
(244)
22"
(559)
297/8"
(759)
23/4"
(70)
233/4" (603)
BEHIND FRAME
OPEN OVEN DOOR
22"
(559)
wolfappliance.com | 19
Page 20
E SERIES OVENS
30" E Series Built-In Ovens
PROFESSIONAL SINGLE OVEN
1" (25)
277/8"
(708)
297/8"
(759)
33/8"
(86)
PROFESSIONAL DOUBLE OVEN
1" (25)
503/8"
(1280)
(76)
3"
CONDUIT
CHANNEL
233/4" (603)
BEHIND FRAME
(76)
3"
CONDUIT
CHANNEL
271/8"
(689)
495/8"
(1261)
87/8"
(225)
281/4"
(718)
OPEN OVEN DOOR
87/8"
(225)
281/4"
(718)
95/8"
(244)
95/8"
(244)
22"
(559)
297/8"
(759)
33/8"
(86)
20 | Wolf Customer Care 800.222.7820
233/4" (603)
BEHIND FRAME
OPEN OVEN DOOR
22"
(559)
Page 21
E SERIES OVENS
30" E Series Built-In Ovens
CONTEMPORARY SINGLE OVEN
(32)
11/4"
277/8"
(708)
(76)
3"
CONDUIT
CHANNEL
271/16"
(687)
87/8"
(225)
281/4"
(718)
95/8"
(244)
297/8"
(759)
3"
(76)
CONTEMPORARY DOUBLE OVEN
11/4" (32)
503/8"
(1280)
297/8"
(759)
3"
(76)
233/4" (603)
BEHIND FRAME
(76)
3"
CONDUIT
CHANNEL
233/4" (603)
BEHIND FRAME
491/2"
(1257)
OPEN OVEN DOOR
87/8"
(225)
281/4"
(718)
OPEN OVEN DOOR
95/8"
(244)
22"
(559)
22"
(559)
wolfappliance.com | 21
Page 22
E SERIES OVENS
Planning Information
E series ovens can be installed in a standard or ush inset
application. If a cooktop is being installed above an oven, a
minimum of
tion of the electrical supply within the oven opening may
require additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
For ush inset installations, a minimum reveal is required
on all sides. Refer to the chart below. To ensure consistent
reveals, each corner of the opening must be exactly 90°.
1
/4" (6) is required between the units. The loca-
INSTALLATION REQUIREMENTS
BASE SUPPORTMIN
24" Oven150 lb (68 kg)
30" Single Oven250 lb (113 kg)
30" Double Oven400 lb (181 kg)
TRIM OVERLAP24" OVEN30" OVEN
Top
Bottom0" (0)
Sides
REVEALMIN
24" Oven
30" Oven
1
11
/16" (17)
/4" (6)
1
/2" (13)
1
11
/16" (17)
1
1
/8" (3)
/8" (3)
/4" (6)
22 | Wolf Customer Care 800.222.7820
Page 23
E SERIES OVENS
Electrical Requirements
24" OVEN
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation. Refer to the illustration below for minimum power
cord plug clearance.
Performance may be compromised if the electrical supply is
less than 240 volts.
ELECTRICAL REQUIREMENTS—24" OVEN
Electrical Supplygrounded, 240/ 208 VAC, 60 Hz
Service20 amp dedicated circuit
ReceptacleNEMA 6-20R grounding-type
Power Cord6'
(1.8 m)
30" OVEN
Installation must comply with all applicable electrical codes.
Locate the electrical supply ush with the back wall and
within the shaded area shown in the illustrations on the following pages. For ease of installation, the electrical supply
for the oven can be placed in an adjacent cabinet within
reach of the conduit.
Performance may be compromised if the electrical supply is
less than 240 volts.
The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground conductor.
The wiring diagram covering the control circuit is provided
with the oven.
ELECTRICAL REQUIREMENTS—30" SINGLE OVEN
Electrical Supplygrounded, 240/ 208 VAC, 60 Hz
Service30 amp dedicated circuit
Conduit4'
Total Amps21
Max Connected Load5.1 kW
(1.2 m)
1" (25)
MINIMUM
CLEARANCE
Power cord clearance
CORD
ELECTRICAL REQUIREMENTS—30" DOUBLE OVEN
Electrical Supplygrounded, 240/ 208 VAC, 60 Hz
Service50 amp dedicated circuit
Conduit5'
Total Amps37
Max Connected Load8.9 kW
(1.5 m)
wolfappliance.com | 23
Page 24
E SERIES OVENS
SIDE
24" E Series Single Oven
STANDARD INSTALLATION
23" (584)
OPENING
TOP VIEW
DEPTH
VIEW
231/4"
(591)
OPENING
HEIGHT
E
221/8" (562)
OPENING WIDTH
FRONT VIEW
24 | Wolf Customer Care 800.222.7820
Page 25
SIDE
*W
**
E SERIES OVENS
24" E Series Single Oven
FLUSH INSET INSTALLATION
7
/8" (22)
TOP VIEW
24" (610)
FLUSH
INSET
DEPTH
FINISHED
CLEATS*
233/4" (603)
FLUSH INSET
HEIGHT**
VIEW
ill be visible and should be finished to match cabinetry.
Dimension provides minimum reveals.
3
E
/8" (10)
13
/16" (21)
1
/8" (3)
233/4" (603)
FLUSH INSET WIDTH**
FRONT VIEW
wolfappliance.com | 25
Page 26
E SERIES OVENS
SIDE
NOTE: Location of electrical supply within opening may require additional cabinet depth.
30" E Series Single Oven
STANDARD INSTALLATION
TOP VIEW
24" (610)
OPENING
DEPTH
VIEW
271/4"
(692)
OPENING
HEIGHT
281/2" (724)
OPENING WIDTH
FRONT VIEW
5"
(127)
E
4"
(102)
E
E
26 | Wolf Customer Care 800.222.7820
Page 27
E SERIES OVENS
SIDE
*W
**
**
NOTE: Location of electrical supply within opening may require additional cabinet depth.
30" E Series Single Oven
FLUSH INSET INSTALLATION
1" (25)
OR
11/4" (32)**
FLUSH INSET WIDTH***
FLUSH INSET
TOP VIEW
303/8" (772)
25"
DEPTH
(635)
FINISHED
CLEATS*
283/8"
(721)
FLUSH INSET
HEIGHT***
15
VIEW
ill be visible and should be finished to match cabinetry.
1" (25) for professional and transitional models and 11/4" (32) for contemporary model.
*Dimension provides minimum reveals.
(24)
/16"
FRONT VIEW
3
/4"(19)
3
/8" (10)
5"
(127)
E
4"
(102)
E
E
wolfappliance.com | 27
Page 28
E SERIES OVENS
SIDE
NOTE: Location of electrical supply within opening may require additional cabinet depth.
30" E Series Double Oven
STANDARD INSTALLATION
TOP VIEW
24" (610)
OPENING
DEPTH
VIEW
493/4"
(1264)
OPENING
HEIGHT
17" (432)
TYPICAL
281/2" (724)
OPENING WIDTH
FRONT VIEW
5"
(127)
E
4"
(102)
E
E
28 | Wolf Customer Care 800.222.7820
Page 29
E SERIES OVENS
SIDE
*W
**
**
NOTE: Location of electrical supply within opening may require additional cabinet depth.
30" E Series Double Oven
FLUSH INSET INSTALLATION
507/8"
(1292)
FLUSH INSET
HEIGHT***
1" (25)
OR
11/4" (32)**
FLUSH INSET WIDTH***
15
/16" (24)
FLUSH INSET
TOP VIEW
303/8" (772)
3
/4"(19)
25" (635)
DEPTH
5"
(127)
E
4"
(102)
FINISHED
CLEATS*
E
17" (432)
TYPICAL
VIEW
ill be visible and should be finished to match cabinetry.
1" (25) for professional and transitional models and 11/4" (32) for contemporary model.
*Dimension provides minimum reveals.
3
/8" (10)
FRONT VIEW
E
wolfappliance.com | 29
Page 30
L SERIES OVEN
30 | Wolf Customer Care 800.222.7820
Page 31
L SERIES OVEN
L Series Built-In Oven
Since their introduction, Wolf L series built-in ovens have
taken the culinary world by storm—and not just for their
stylish cobalt blue interior and 10 cooking modes. Thanks
to a Wolf innovation called dual convection, the L series
delivers faster, more consistent results for baking, roasting,
broiling—even drying fruits. The Wolf L series oven is offered
in the 36" width with unframed door style and tubular
handle.
L SERIES OVEN
UNFRAMED
SO36U/S
wolfappliance.com | 31
Page 32
L SERIES OVEN
L Series Built-In Oven
36" SINGLE OVEN
243/8"
(619)
(76)
3"
CONDUIT
CHANNEL
23"
(584)
341/8"
(867)
87/8"
(225)
95/8"
(244)
355/8"
(905)
(76)
3"
24" (610)
BEHIND FRAME
OPEN OVEN DOOR
173/4"
(451)
32 | Wolf Customer Care 800.222.7820
Page 33
L SERIES OVEN
Planning Information
If a cooktop is being installed above an oven, a minimum
1
/4" (6) is required between the units. The location of the
of
electrical supply within the oven opening may require additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
INSTALLATION REQUIREMENTS
BASE SUPPORTMIN
36" Single Oven250 lb (113 kg)
TRIM OVERLAP
Top
Bottom
Sides
3
/16" (5)
1
/8" (3)
9
/16" (14)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply ush with the back wall and
within the shaded area shown in the illustration on the following page. For ease of installation, the electrical supply for
the oven can be placed in an adjacent cabinet within reach
of the conduit.
Performance may be compromised if the electrical supply is
less than 240 volts.
The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground conductor.
The wiring diagram covering the control circuit is provided
with the oven.
ELECTRICAL REQUIREMENTS
Electrical Supplygrounded, 240/ 208 VAC, 60 Hz
Service30 amp dedicated circuit
Conduit3'
Total Amps21
Max Connected Load5.1 kW
(.9 m)
wolfappliance.com | 33
Page 34
SIDE
NOTE: Location of electrical supply within opening may require additional cabinet depth.
L SERIES OVEN
36" L Series Single Oven
STANDARD INSTALLATION
TOP VIEW
24" (610)
OPENING
DEPTH
VIEW
241/16"
(611)
OPENING
HEIGHT
341/2" (876)
OPENING WIDTH
FRONT VIEW
5"
(127)
E
4"
(102)
E
E
34 | Wolf Customer Care 800.222.7820
Page 35
L SERIES OVEN
wolfappliance.com | 35
Page 36
CONVECTION STEAM OVENS
36 | Wolf Customer Care 800.222.7820
Page 37
CONVECTION STEAM OVENS
Convection Steam Ovens
The legacy of the “combination oven” goes back decades,
to innovative chefs in America and Europe who embraced
the combination of air movement with superheated steam
to achieve superior results—from breads and roasts to
delicate shes, seafood, and vegetables. Wolf combines the
benets of convection and steam for the most innovative
steam oven on the market today. Virtually any dish prepared
in a conventional oven, range, or microwave can also be
prepared in the Wolf convection steam oven—with more
control. Two widths and three distinct styles compliment
the look of Wolf ovens, ranges, and cooktops. Convection
steam ovens can be installed in a standard or ush inset
application.
CONVECTION STEAM OVENS
TRANSITIONAL
CSO24TE/S/TH
PROFESSIONAL
CSO30PM/S/PH
CONTEMPORARY
CSO30CM/B/TH
CSO30TM/S/TH
CSO30PE/S/PH
CSO30CMS
CSO30TE/S/TH
CSO30CMB
wolfappliance.com | 37
Page 38
CONVECTION STEAM OVENS
Convection Steam Ovens
TRANSITIONAL
7
/8"
(22)
171/2"
W
WIDTH
177/8"
(454)
21/2"
(64)
211/2" (546)
BEHIND FRAME
WIDTH
24" Transitional231/2" (597)
30" Transitional297/8" (759)
PROFESSIONAL
7
/8"
(22)
177/8"
(454)
171/2"
(446)
W
(446)
213/16"
(538)
OPEN OVEN DOOR
213/16"
(538)
143/16"
(360)
297/8"
(759)
31/4"
(83)
CONTEMPORARY
177/8"
(454)
297/8"
(759)
21/2"
(64)
38 | Wolf Customer Care 800.222.7820
211/2" (546)
BEHIND FRAME
7
/8"
(22)
211/2" (546)
BEHIND FRAME
171/2"
(446)
OPEN OVEN DOOR
213/16"
(538)
OPEN OVEN DOOR
143/16"
(360)
143/16"
(360)
Page 39
CONVECTION STEAM OVENS
Planning Information
The convection steam oven can be installed in a standard or
ush inset application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
1
For ush inset installations, a minimum
/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORTMIN
Convection Steam Oven100 lb (45 kg)
TRIM OVERLAP24" MODEL30" MODEL
Top
Bottom0" (0)0" (0)
Sides
3
/16" (5)
11
/16" (18) 37/8" (98)
3
/16" (5)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation. Refer to the illustration below for minimum power
cord plug clearance.
Performance may be compromised if the electrical supply is
less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supplygrounded, 240/ 208 VAC, 60 Hz
Service20 amp dedicated circuit
ReceptacleNEMA 6-20R grounding-type
Power Cord6'
(1.8 m)
1" (25)
MINIMUM
CLEARANCE
Power cord clearance
CORD
wolfappliance.com | 39
Page 40
SIDE
NOTE: 24"
CONVECTION STEAM OVENS
Convection Steam Oven
STANDARD INSTALLATION
23" (584)
OPENING
TOP VIEW
DEPTH
1711/16"
(449)
OPENING
HEIGHT
VIEW
(610) and 30" (762) models require the same opening dimensions.
OPENING WIDTH
24" Model221/8" (562)
30" Model221/8" (562)
W
E
OPENING WIDTH
FRONT VIEW
W
40 | Wolf Customer Care 800.222.7820
Page 41
SIDE
*W
**
CONVECTION STEAM OVENS
Convection Steam Oven
FLUSH INSET INSTALLATION
7
/8"
(22)
TOP VIEW
24" (610)
FLUSH INSET
DEPTH
FINISHED
CLEATS*
181/8"
(460)
FLUSH INSET
HEIGHT**
VIEW
ill be visible and should be finished to match cabinetry.
Dimension provides minimum reveals.
FLUSH INSET WIDTH
24" Model233/4" (603)
WA
13
/16" (21)
30" Model301/8" (765)4" (102)
5
E
/16"(8)
A
1
/8" (3)
FLUSH INSET WIDTH**
W
FRONT VIEW
wolfappliance.com | 41
Page 42
MICROWAVE OVENS
42 | Wolf Customer Care 800.222.7820
Page 43
MICROWAVE OVENS
Microwave Ovens
As true cooking instruments, Wolf microwave ovens have
features that make fast meals better meals. The new dropdown door microwaves feature a door that hinges at the
bottom for easier access to foods. Available in 24" and
30" widths, they are designed to match Wolf transitional,
professional, and contemporary products. Drawer microwave ovens can be conveniently located undercounter, in
a corner, or below an oven. Wolf also offers both a roomy,
powerful standard microwave and a convection model that
can microwave, broil, and cook in three convection modes.
Trim kits to match Wolf ovens are available through an
authorized Wolf dealer. Microwave ovens can be installed in
a standard or ush inset application.
DROP-DOWN DOOR MICROWAVES
TRANSITIONAL
MDD24TE/S/TH
PROFESSIONAL
MDD30PM/S/PH
CONTEMPORARY
MDD30CM/B/TH
MDD30TM/S/TH
MDD30PE/S/PH
DRAWER MICROWAVE
TRANSITIONAL
MDD30TE/S/TH
MD24TE/S
PROFESSIONAL
MD30PE/S
MD30TE/S
CONVECTION MICROWAVE
MC24 (M
/E TRIM)
MC24 (L TRIM)
STANDARD MICROWAVE
MS24 (M
/E TRIM)
MS24 (L TRIM)
wolfappliance.com | 43
Page 44
MICROWAVE OVENS
Drop-Down Door Microwave Ovens
TRANSITIONAL
7
/8"
(22)
213/16"
(538)
171/2"
W
WIDTH
177/8"
(454)
21/2"
(64)
20" (508)
BEHIND FRAME
WIDTH
24" Transitional231/2" (597)
30" Transitional297/8" (759)
PROFESSIONAL
7
/8"
(22)
171/2"
297/8"
(759)
177/8"
(454)
31/4"
(83)
20" (508)
BEHIND FRAME
(446)
W
(446)
OPEN
OVEN DOOR
213/16"
(538)
143/16"
(360)
CONTEMPORARY
177/8"
(454)
297/8"
(759)
21/2"
(64)
44 | Wolf Customer Care 800.222.7820
7
/8"
(22)
20" (508)
BEHIND FRAME
171/2"
(446)
OPEN
OVEN DOOR
213/16"
(538)
OPEN
OVEN DOOR
143/16"
(360)
143/16"
(360)
Page 45
MICROWAVE OVENS
Drawer Microwave Ovens
TRANSITIONAL / PROFESSIONAL
WIDTH
297/8" (759)
151/8"
(384)
11/4"
(32)
217/8" (556)
BEHIND FRAME
13/4"
POWER CORD
(45)
CHANNEL
24" Model237/8" (606)
30" Model297/8" (759)
145/8"
(372)
W
215/8" (549)
45/8"
(118)
OPEN DRAWER
161/2"
(419)
wolfappliance.com | 45
Page 46
MICROWAVE OVENS
*1
147/8"
(378)
FREE-
STANDING
243/4" (629)
FREESTANDING
197/8"
(505)
WITHTRIM
TRIM WIDTH
18"
(457)
BEHIND TRIM
*11/4" (32) for contemporary E series trim only.
1" (25) OR11/4" (32)*
Convection Microwave Oven
M/E SERIES TRIM
243/4" (629)
FREESTANDING
TRIM WIDTH
1
/4" (32) for contemporary E series trim only.
TRIM WIDTH
M SERIESE SERIESL SERIES
197/8"
(505)
WITH
TRIM
1" (25) OR
11/4" (32)*
(457)
18"
BEHIND TRIM
147/8"
(378)
FREE-
STANDING
27" TrimNA267/8" (683)NA
30" Trim297/8" (759)297/8" (759)297/8" (759)
36" TrimNANA355/8" (905)
L SERIES TRIM
243/4" (629)
FREESTANDING
TRIM WIDTH
197/8"
(505)
WITH
TRIM
13/8"
(35)
(448)
175/8"
BEHIND TRIM
147/8"
(378)
FREE-
STANDING
46 | Wolf Customer Care 800.222.7820
Page 47
MICROWAVE OVENS
*1
TRIM WIDTH
133/8"
(340)
FREE-
STANDING
24" (610)
FREESTANDING
181/4"
(464)
WITH
TRIM
18" (457)
BEHIND TRIM
*11/4" (32) for contemporary E series trim only.
1" (25) OR11/4" (32)*
Standard Microwave Oven
M/E SERIES TRIM
24" (610)
FREESTANDING
TRIM WIDTH
1
/4" (32) for contemporary E series trim only.
TRIM WIDTH
M SERIESE SERIESL SERIES
181/4"
(464)
WITH
TRIM
1" (25) OR
11/4" (32)*
18" (457)
BEHIND TRIM
133/8"
(340)
FREE-
STANDING
27" TrimNA267/8" (683)NA
30" Trim297/8" (759)297/8" (759)297/8" (759)
L SERIES TRIM
24" (610)
FREESTANDING
TRIM WIDTH
181/4"
(464)
WITH
TRIM
13/8"
(35)
175/8" (448)
BEHIND TRIM
133/8"
(340)
FREE-
STANDING
wolfappliance.com | 47
Page 48
MICROWAVE OVENS
Planning Information
DROP-DOWN DOOR MICROWAVE
The drop-down door microwave oven can be installed in a
standard or ush inset application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
1
For ush inset installations, a minimum
/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORTMIN
Drop-Down Door Microwave125 lb (57 kg)
TRIM OVERLAP24" MODEL30" MODEL
Top
Bottom0" (0)0" (0)
Sides
3
/16" (5)
11
/16" (18) 37/8" (98)
3
/16" (5)
DRAWER MICROWAVE
The drawer microwave oven can be installed in a standard
or ush inset application. The location of the electrical
supply within the oven opening may require additional
cabinet depth.
Finish the edges of the opening. They may be visible when
the drawer is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
1
For ush inset installations, a minimum
required on the top and sides and
/8" (3) reveal is
11
/16" (18) on the bottom.
To ensure consistent reveals, each corner of the opening
must be exactly 90°. A sales accessory is required to direct
air away from the unit. Accessories are available through an
authorized Wolf dealer. For local dealer information, visit the
nd a showroom section of our website, wolfappliance.com.
INSTALLATION REQUIREMENTS
BASE SUPPORTMIN
24" Drawer Microwave125 lb (57 kg)
30" Drawer Microwave125 lb (57 kg)
TRIM OVERLAP24" MODEL30" MODEL
Top
Bottom
Sides
5
/16" (8)
1
/16" (2)
7
/8" (22)37/8" (98)
5
/16" (8)
1
/16" (2)
48 | Wolf Customer Care 800.222.7820
Page 49
MICROWAVE OVENS
Planning Information
CONVECTION / STANDARD MICROWAVES
Convection and standard microwave ovens can be installed
in a standard or ush inset application using accessory
trim to match Wolf ovens. Trim kits are avail able through an
authorized Wolf dealer. For local dealer information, visit the
nd a showroom section of our website, wolfappliance.com.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
Convection and standard microwave ovens can also be
used freestanding. For freestanding applications, a minimum
(51) space is required at the top, rear, and sides of the
2"
microwave oven for air circulation.
INSTALLATION REQUIREMENTS
BASE SUPPORTMIN
Convection Microwave125 lb (57 kg)
Standard Microwave125 lb (57 kg)
27" E SERIES TRIM OVERLAPCONVSTAN
Top
Bottom
Sides
30" M/E/L TRIM OVERLAPCONVSTAN
Top
Bottom
Sides13/16" (30)13/16" (30)
36" L SERIES TRIM OVERLAPCONVSTAN
Top
Bottom
Sides1
1
/4" (6)
3
/4" (19)
13
/16" (21)
1
/4" (6)
3
/4" (19)
3
/16" (5)NA
13
/16" (21)NA
1
/4" (32)NA
9
/16" (14)
11
/16" (17)
13
/16" (21)
9
/16" (14)
11
/16" (17)
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on
the following pages. The receptacle may also be located
in an adjacent cabinet within reach of the power cord. A
separate circuit servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) is not recommended
and may cause interruption of operation. Refer to the illustration below for minimum power cord plug clearance.
ELECTRICAL REQUIREMENTS
Electrical Supplygrounded, 120 VAC, 60 Hz
Service15 amp dedicated circuit
Receptacle3-prong grounding-type
Power Cord4'
3"
(76)
MINIMUM CORD
CLEARANCE
Power cord clearance
(1.2 m)
wolfappliance.com | 49
Page 50
MICROWAVE OVENS
SIDE
NOTE: 24"
Drop-Down Door Microwave Oven
STANDARD INSTALLATION
OPENING
TOP VIEW
219/16"
(548)
DEPTH
1711/16"
(449)
OPENING
HEIGHT
VIEW
(610) and 30" (762) models require the same opening dimensions.
OPENING WIDTH
24" Model221/8" (562)
30" Model221/8" (562)
W
E
OPENING WIDTH
FRONT VIEW
W
50 | Wolf Customer Care 800.222.7820
Page 51
MICROWAVE OVENS
SIDE
*W
**
Drop-Down Door Microwave Oven
FLUSH INSET INSTALLATION
7
/8" (22)
FLUSH INSET
TOP VIEW
23" (584)
DEPTH
FINISHED
CLEATS*
181/8"
(460)
FLUSH INSET
HEIGHT**
VIEW
ill be visible and should be finished to match cabinetry.
Dimension provides minimum reveals.
FLUSH INSET WIDTH
24" Model233/4" (603)
WA
13
/16" (21)
30" Model301/8" (765)4" (102)
5
E
/16"(8)
A
1
/8" (3)
FLUSH INSET WIDTH**
W
FRONT VIEW
wolfappliance.com | 51
Page 52
MICROWAVE OVENS
SIDE
NOTE: All dr
Drawer Microwave Oven
STANDARD INSTALLATION
22" (559)
OPENING
DEPTH
TOP VIEW
ANTI-TIP BLOCK
(375)
143/4"
OPENING
HEIGHT
VIEW
awer microwave ovens require the same opening dimensions.
OPENING WIDTH
24" Model221/8" (562)
30" Model221/8" (562)
W
E
W
OPENING WIDTH
FRONT VIEW
52 | Wolf Customer Care 800.222.7820
Page 53
MICROWAVE OVENS
SIDE
*W
**
Drawer Microwave Oven
FLUSH INSET INSTALLATION
11/4" (32)
231/4"
FLUSH INSET
TOP VIEW
DEPTH
(591)
FINISHED
CLEATS*
ANTI-TIP BLOCK
1515/16"
VIEW
ill be visible and should be finished to match cabinetry.
Dimension provides minimum reveals.
FLUSH INSET WIDTH
(405)
FLUSH INSET
HEIGHT**
WA
24" Model241/8" (613)1" (25)
30" Model301/8" (765)4" (102)
7
E
/16"(11)
A
3
/4" (19)
FLUSH INSET WIDTH**
W
FRONT VIEW
wolfappliance.com | 53
Page 54
MICROWAVE OVENS
SIDE
Convection Microwave Oven
STANDARD INSTALLATION WITH TRIM
201/8" (511)
TOP VIEW
OPENING
DEPTH
187/8" (479)
OPENING
HEIGHT
VIEW
OPENING WIDTH
27" Trim251/4" (641)
30" Trim271/2" (699)
36" Trim333/8" (854)
E
W
W
OPENING WIDTH
FRONT VIEW
54 | Wolf Customer Care 800.222.7820
Page 55
MICROWAVE OVENS
*W
**
**
SIDE
Convection Microwave Oven
FLUSH INSET INSTALLATION WITH TRIM
201/8" (511)
FLUSH INSET
HEIGHT***
(25)
1"
OR
11/4" (32)**
TOP VIEW
3
E
/8"
A
7
/8" (22)
FLUSH INSET WIDTH***
231/4"
FLUSH INSET
DEPTH
(10)
W
(591)
FINISHED
CLEATS*
VIEW
ill be visible and should be finished to match cabinetry.
11/4" (32) for contemporary E series trim only.
*Dimension provides minimum reveals.
FLUSH INSET WIDTH
27" Trim271/8" (689)
WA
15
/16" (24)
30" Trim301/8" (765)13/16" (30)
FRONT VIEW
wolfappliance.com | 55
Page 56
MICROWAVE OVENS
SIDE
Standard Microwave Oven
STANDARD INSTALLATION WITH TRIM
TOP VIEW
20" (508)
OPENING
DEPTH
17" (432)
OPENING
HEIGHT
VIEW
OPENING WIDTH
27" Trim251/4" (641)
30" Trim271/2" (699)
E
W
W
OPENING WIDTH
FRONT VIEW
56 | Wolf Customer Care 800.222.7820
Page 57
MICROWAVE OVENS
SIDE
*W
**
**
Standard Microwave Oven
FLUSH INSET INSTALLATION WITH TRIM
181/2" (470)
FLUSH INSET
HEIGHT***
(25)
1"
OR
11/4" (32)**
TOP VIEW
11
E
/16"
A
13
/16" (21)
FLUSH INSET WIDTH***
231/4"
FLUSH INSET
DEPTH
(17)
W
(591)
FINISHED
CLEATS*
VIEW
ill be visible and should be finished to match cabinetry.
11/4" (32) for contemporary E series trim only.
*Dimension provides minimum reveals.
FLUSH INSET WIDTH
27" Trim271/8" (689)
WA
15
/16" (24)
30" Trim301/8" (765)13/16" (30)
FRONT VIEW
wolfappliance.com | 57
Page 58
WARMING DRAWERS
58 | Wolf Customer Care 800.222.7820
Page 59
WARMING DRAWERS
Warming Drawers
Wolf warming drawers are designed to take care of prepared foods until it’s time to serve them. You can adjust the
temperature, keeping moist foods moist, and crisp foods
crisp. Warming drawers are ideal for proong dough. They
can also be used to warm robes and towels. Drawer fronts
are available to match the look of Wolf ovens, sealed burner
rangetops, and outdoor grills. The integrated drawer front
allows for a custom panel and handle. Model WWD30O,
approved for outdoor installations, is ideal for any outdoor
kitchen.
WARMING DRAWER FRONTS
M/E SERIES
TRANSITIONAL
L SERIES
TRANSITIONAL
INTEGRATED
CUSTOM PANEL
PROFESSIONAL
CONTEMPORARY
wolfappliance.com | 59
Page 60
WARMING DRAWERS
Warming Drawers
DRAWER FRONT OPTIONS
Wolf warming drawer fronts allow for many design options,
but the warming drawer itself will be the same for all applications. A panel mounting kit is required when installing a
custom panel. The panel mounting kit is available through
an authorized Wolf dealer. For local dealer information,
visit the nd a showroom section of our website,
wolfappliance.com.
(51) thick drawer front, in 30"and 36" widths, is
The 2"
designed to be installed below a sealed burner rangetop or
outdoor gas grill, so the panel aligns properly with the front
of the rangetop or grill. Dimensions for the warming drawer
remain the same, even though the drawer front may be
wider to match a Wolf 36" oven, sealed burner rangetop,
or outdoor grill.
Dimensions (typical)297/8" (759)103/8" (264)
Min Thickness
7
/8" (22)31/2" (89)
3
/4" (19)
5
/8" (16)
60 | Wolf Customer Care 800.222.7820
Page 61
WARMING DRAWERS
Planning Information
The warming drawer must be installed with a Wolf drawer
front, avail able through an authorized Wolf dealer. For local
dealer information, visit the nd a showroom section of our
website, wolfappliance.com. Specic installation instructions are included with the drawer front.
The warming drawer can be installed in a standard or ush
inset application (excludes L series drawer front).
For a standard installation, the drawer collar and front panel
sit proud of the cabinet face frame. A recessed installation
3
requires the cabinetry be recessed by
/16" (5) so the collar
is ush with the cabinet face frame but the drawer front
will sit proud. A ush inset installation (excludes L series)
requires the drawer collar and front panel be recessed to be
ush with surrounding cabinetry. Refer to illustrations on the
following pages for minimum cabinet dimensions for your
specic installation.
Finish the edges of the opening. They may be visible when
the drawer is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
1
For ush inset installations, a minimum
/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply ush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the warming drawer can be placed in an adjacent
cabinet within reach of the power cord.
IMPORTANT NOTE: When installed outdoors, a ground fault
circuit interrupter (GFCI) is required to reduce the risk of
electrical shock.
ELECTRICAL REQUIREMENTS
Electrical Supplygrounded, 120 VAC, 60 Hz
Service15 amp dedicated circuit
Receptacle3-prong grounding-type
Power Cord3'
(.9 m)
Model WWD30O is CSA approved for outdoor installations.
INSTALLATION REQUIREMENTS
Min Base Support200 lb (90 kg)
Trim Overlap (top, bottom, sides)
5
/8" (16)
wolfappliance.com | 61
Page 62
WARMING DRAWERS
SIDE
NOTE: Location of electrical supply within opening may require additional cabinet depth.
Warming Drawer
STANDARD INSTALLATION
TOP VIEW
23" (584)
OPENING
DEPTH
ANTI-TIP BLOCK
91/8" (232)
OPENING
HEIGHT
VIEW
285/8" (727)
OPENING WIDTH
FRONT VIEW
E
62 | Wolf Customer Care 800.222.7820
Page 63
SIDE
*W
**
**
NOTE: Location of electrical supply within opening may require additional cabinet depth.
WARMING DRAWERS
Warming Drawer
FLUSH INSET INSTALLATION
A
DRAWER
FRONT
DEPTH
FLUSH INSET
TOP VIEW
24" (610)
DEPTH***
FINISHED
CLEATS*
ANTI-TIP BLOCK
105/8"
(270)
FLUSH INSET
HEIGHT**
VIEW
ill be visible and should be finished to match cabinetry.
Dimension provides minimum reveals.
*241/8" (613) for E series contemporary drawer front.
DRAWER FRONT DEPTH (A)
Transitional/Professional
Professional (2" thick)NA21/8" (54)
Contemporary Stainless
Contemporary Black1"
M SERIESE SERIES
7
/8" (22)11/8" (29)
7
/8" (22)NA
(25)1
Custom front panel depth is dependent on panel thickness. Add
the panel thickness to determine the drawer front depth.
3
/8" (35)
1
/4" (6) to
3
/4"(19)
3
/4"(19)
3
/4"(19)
301/8" (765)
FLUSH INSET WIDTH**
FRONT VIEW
E
E
wolfappliance.com | 63
Page 64
INDUCTION | ELECTRIC COOKTOPS
64 | Wolf Customer Care 800.222.7820
Page 65
INDUCTION COOKTOPS
Induction Cooktops
Almost instantaneous temperature response. Practically no
wasted heat. Induction cooking has been popular among
European chefs and homeowners for decades. Now Wolf
leads the way in bringing this remarkable technology to
North American kitchens. Its secret is magnetism. Electromagnetic elements cause iron and magnetic stainless cookware to heat up instantly and with perfectly distributed heat.
Heat generation stops the instant you turn off the element or
remove the pan. The cooktop’s surface remains cool. Your
kitchen stays cooler too.
Transitional models have a brushed stainless steel trim.
Contemporary models can be mounted ush with the
countertop. The following models have the same stainless
steel frame as our module cooktops for paired installations:
CI243TF/S, CI304TF/S, and CI365TF/S.
INDUCTION COOKTOPS
TRANSITIONAL FRAMED
CI243TF/S
TRANSITIONAL
CI304T/S
CONTEMPORARY
CI243C/B
CI304TF/S
CI365T/S
CI304C/B
CI365TF/S
CI365C/B
wolfappliance.com | 65
Page 66
INDUCTION COOKTOPS
Induction Cooktops
24" TRANSITIONAL
21"
(533)
235/8" (600)
11/4" (32)
CONDUIT
7
/8"
(22)
2" (51)
24" CONTEMPORARY
21"
(533)
235/8" (600)
30" TRANSITIONAL
30" (762)
CONDUIT
7
/8"
11/4" (32)
(22)
30" CONTEMPORARY
30" (762)
21"
(533)
2" (51)
21"
(533)
36" TRANSITIONAL
36" (914)
CONDUIT
7
11/4" (32)
(22)
36" CONTEMPORARY
36" (914)
21"
(533)
2" (51)
/8"
21"
(533)
21/2" (64)
/8"
11/4" (32)
11/4" (32)
CONDUIT
7
(22)
ELEMENT RATING
24" COOKTOPW
11" (279)2600/3150 boost
(203)2100/3000 boost
8"
(203)2100
8"
30" COOKTOPW
11" (279)2600/3150 boost
(203)2100/3000 boost
8"
8" (203)2100
(152)1400
6"
36" COOKTOPW
11" (279)2600/3700 boost
(203)2100/3000 boost
(2) 8"
(203)2100
(2) 8"
CONDUIT
7
/8"
(22)
21/2" (64)
11/4" (32)
CONDUIT
7
/8"
(22)
21/2" (64)
66 | Wolf Customer Care 800.222.7820
Page 67
ELECTRIC COOKTOPS
Electric Cooktops
New generation electric cooktops use high-frequency
pulsation technology for the most exceptional performance and control ever in a Wolf electric cooktop, with
blazing hot sears at the high end and steady simmers and
melts at the low end—a low-end nesse that is unusual in
an electric cooktop. The updated element conguration
accommodates a wide variety of cooking vessels and dish
preparation.
ELECTRIC COOKTOPS
TRANSITIONAL
CE304T/S
CONTEMPORARY
CE304C/B
CE365T/S
CE365C/B
wolfappliance.com | 67
Page 68
ELECTRIC COOKTOPS
Electric Cooktops
30" TRANSITIONAL
30" (762)
CONDUIT
7
/8"
11/4" (32)
(22)
21"
(533)
31/2" (89)
36" TRANSITIONAL
36" (914)
11/4" (32)
CONDUIT
7
(22)
30" CONTEMPORARY36" CONTEMPORARY
21"
(533)
30" (762)
36" (914)
21"
(533)
31/2" (89)
/8"
21"
(533)
4" (102)
/8"
11/4" (32)
CONDUIT
7
(22)
ELEMENT RATING
30" COOKTOPW
101/2" (267) Triple1050/1950/2700
1
/2" (140) Singles1200
(2) 5
1
/2" (165) Single with Oval2400
6
36" COOKTOPW
101/2" (267) Triple1050/1950/2700
(203) Dual700/2200
8"
51/2" (140) Single1200
(178) Singles with Bridge4400
(2) 7"
11/4" (32)
CONDUIT
7
/8"
(22)
4" (102)
68 | Wolf Customer Care 800.222.7820
Page 69
INDUCTION | ELECTRIC COOKTOPS
Planning Information
A minimum 2" (51) is required from the bottom of the
cooktop to combustible materials.
Contemporary induction and electric cooktops can be
mounted ush with the top of the countertop, or as a frameless standard installation sitting on top of the countertop
surface. If the cooktop is to be mounted ush with the
countertop, a recessed area surrounding the cooktop cutout
must be provided.
IMPORTANT NOTE: Flush mount installations are intended
for granite, solid surface, or stone countertop surfaces only.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on
the following pages. A separate circuit servicing only this
appliance is required.
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
ectrical supply location only applies to installations with built-in oven.
CUTOUT WIDTH
W
24" Induction221/8" (562)
30" Induction/Electric29" (737)
36" Induction/Electric35" (889)
70 | Wolf Customer Care 800.222.7820
FRONT VIEW
Page 71
INDUCTION | ELECTRIC COOKTOPS
SIDE
NO
combus
El
Outsid
24" / 30" / 36" Cooktop
FLUSH INSTALLATION
13"
(330)
COUNTERTOP
7
/8"
(22) MAX
PROFILE
5
(8)
/16"
36" (914) min
FLOOR TO
COUNTERTOP
211/8"
(537)
RECESS
19/16" (40) min
18"
(457)
2"
(51)
W
CUTOUT WIDTH
A
RECESS
COUNTERTOP CUTOUT
30"
(762)
41/2" (114)
31/2" (89)
10" (254)
21/2" (64)
191/2"
(495)
21/2" (64)
E
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
ectrical supply location only applies to installations with built-in oven.
e corner radius 7/16" (11).
CUTOUT WIDTH
WA
24" Induction221/8" (562)233/4" (603)
30" Induction/Electric29" (737)301/8" (765)
36" Induction/Electric35" (889)361/8" (918)
FRONT VIEW
wolfappliance.com | 71
Page 72
GAS COOKTOPS
72 | Wolf Customer Care 800.222.7820
Page 73
GAS COOKTOPS
Gas Cooktops
Like their oven counterparts, the new generation of Wolf gas
cooktops features three new looks—transitional, professional, and contemporary. New performance enhancements
make delicious results even more of a certainty than ever.
Multiple sizes, choice of knob colors, and distinctly different
grates—the new gas cooktops offer exceptional design
exibility. For a striking, low-prole look, the contemporary
gas cooktop ts ush to the countertop with front-mounted
controls that integrate directly into cabinetry below.
Model CG243TF/S has the same stainless steel frame as
our module cooktops for paired installations.
A minimum 2" (51) is required from the bottom of the
cooktop to combustible materials. If the cooktop is installed
above an oven, a minimum of
units.
The contemporary gas cooktop can be mounted ush with
the top of the countertop, or as a standard installation
sitting on top of the countertop surface. If the cooktop is
to be mounted ush with the countertop, a recessed area
surrounding the cooktop cutout must be provided. The
countertop must be able to withstand temperatures up to
(149°C).
300°F
Control knobs for the contemporary gas cooktop are
designed to be mounted on the front face of cabinetry
below the unit. Mounting holes must be drilled through the
cabinet face. Refer to the illustrations on pages 78–79 for
the hole location.
1
/4" (6) is required between the
wolfappliance.com | 75
Page 76
GAS COOKTOPS
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supplygrounded, 120 VAC, 60 Hz
Service15 amp dedicated circuit
Receptacle3-prong grounding-type
Power Cord6'
(1.8 m)
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certied, 3'
(19)
ID exible metal appliance connector is recommended.
(.9 m) long,
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
will function up to 8,600'
in altitude without adjustment and LP gas cooktops
(2621 m). If the installation exceeds
1
/2" (13) or 3/4"
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
GAS REQUIREMENTS
Gas Supply
Gas Inlet
NATURAL GASWC
Supply Pressure5" (12.5 mb)
Min Line Pressure7" (17.5 mb)
Max Regulator Pressure14" (34.9 mb), .5 psi (3.5 kPa)
LP GASWC
Supply Pressure10" (25 mb)
Min Line Pressure11" (27.4 mb)
Max Regulator Pressure14" (34.9 mb), .5 psi (3.5 kPa)
3
/4" ID line
1
/2" NPT male
76 | Wolf Customer Care 800.222.7820
Page 77
SIDE
NO
combus
El
GAS COOKTOPS
24" / 30" / 36" Transitional / Professional Gas Cooktop
STANDARD INSTALLATION
21/2" (64)
13"
(330)
18"
(457)
9"
(229)
W
WIDTH
COUNTERTOP CUTOUT
30"
(762)
4" (102)
31/2" (89)
E G
10"
(254)
191/2"
(495)
21/2"
(64)
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
ectrical and gas supply location only applies to installations with built-in oven.
CUTOUT WIDTH
W
24" Transitional23" (584)
30" Transitional/Professional29" (737)
36" Transitional/Professional35" (889)
FRONT VIEW
wolfappliance.com | 77
Page 78
GAS COOKTOPS
SIDE
NOTE:
combus
Ma
36" Contemporary Gas Cooktop
STANDARD INSTALLATION
21/2" (64)
13"
(330)
2" (51) MIN–
5"
(127) MAX
18"
(457)
9"
(229)
35" (889)
CUTOUT WIDTH
COUNTERTOP CUTOUT
30"
(762)
5"
11/4" (32)
(127)
10"
(254)
DIAMETER
C
L
4" (102)
37/8"
E G
(98) MIN
20"
(508)
–51/8"
(130) MAX
C
L
VIEW
Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
ximum facade thickness 1" (25). 1" (25) thickness extends 17 " (432) left and right and 2" (51) above and below centerlines.
FRONT VIEW
78 | Wolf Customer Care 800.222.7820
Page 79
GAS COOKTOPS
SIDE
NOTE:
combus
Ma
Outsid
36" Contemporary Gas Cooktop
FLUSH INSTALLATION
COUNTERTOP
PROFILE
1
/2"
(13) MAX
5
(2)
/64"
21"
(533) MIN
RECESS
(889)
35"
CUTOUT WIDTH
36" (914) MIN
RECESS
COUNTERTOP CUTOUT
21/2"
20"
(508)
(64)
13"
(330)
18"
(457)
9"
(229)
2" (51) MIN–
5"
(127) MAX
VIEW
Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
ximum facade thickness 1" (25). 1" (25) thickness extends 17 " (432) left and right and 2" (51) above and below centerlines.
e corner radius 3/8" (10).
30"
(762)
5"
(127)
10"
(254)
C
L
FRONT VIEW
(102)
4"
37/8" (98) MIN–51/8" (130) MAX
11/4" (32)
DIAMETER
E G
C
L
wolfappliance.com | 79
Page 80
MODULE COOKTOPS
80 | Wolf Customer Care 800.222.7820
Page 81
MODULE COOKTOPS
Module Cooktops
Wolf modules have been redesigned to match the updated
lines of Sub-Zero and Wolf. Controls, grates, and trim allow
them to integrate perfectly with their larger counterparts and
deliver equal performance. Combine modules à la cartestyle to create a custom cooktop, or add specialty functions
alongside an existing cooktop.
Full-size cooktops including CI243TF/S, CG243TF/S,
CI304TF/S, and CI365TF/S feature the same brushed stainless frame, making them ideal for pairing with modules.
MODULE COOKTOPS
CI152TF/S
INDUCTION
GM15TF/S
GRILL
CE152TF/S
ELECTRIC
TM15TF/S
TEPPANYAKI
SM15TF/S
STEAMER
CG152TF/S
GAS
FM15TF/S
FRYER
MM15TF/S
MULTIFUNCTION
wolfappliance.com | 81
Page 82
MODULE COOKTOPS
Module Cooktops
INDUCTIONELECTRICSTEAMER
21"
(533)
31/2" (89)
21"
(533)
7
(22)
/8"
15"
(381)
DRAIN
OUTLET
4"
(102)
11/4"
(32)
15"
(381)
CONDUIT
7
/8"
(22)
21"
(533)
2" (51)
21"
(533)
11/4"
(32)
15"
(381)
CONDUIT
7
/8"
(22)
21"
(533)
83/4"
(222)
21"
(533)
FRYER
15"
(381)
7
/8"
(22)
DRAIN
OUTLET
MULTIFUNCTIONGRILLTEPPANYAKIGAS
4"
(102)
21"
(533)
83/4"
(222)
21"
(533)
11/4"
(32)
15"
(381)
7
(22)
15"
(381)
5"
(127)
7
/8"
(22)
/8"
4" (102)
15"
(381)
7
(22)
4" (102)
/8"
15"
(381)
7
(22)
5" (127)
/8"
82 | Wolf Customer Care 800.222.7820
Page 83
MODULE COOKTOPS
Planning Information
IMPORTANT NOTE: Wolf does not recommend the use
of downdraft ventilation with the steamer, fryer, or grill
modules.
A minimum 2"
(51) is required from the bottom of the module
to combustible materials. For the teppanyaki module, a
7
minimum
/8" (22) is required from the bottom of the unit to
any material.
Refer to the illustrations on the following pages for installation of modules.
MULTIPLE COOKTOPS
When multiple cooktops or modules are installed side by
side, refer to the chart and illustration below for typical
congurations. The cutout dimensions provided will accommodate the use of an optional ller strip if desired.
For specic multiple cooktop and module conguration
options or the installation of more than six modules, contact
Wolf Customer Care at 800-222-7820.
COUNTERTOP CUTOUT
(2) 15" Modules*29" (737)
(3) 15" Modules*44" (1118)
(4) 15" Modules*591/4" (1505)
(5) 15" Modules*741/4" (1886)
(6) 15" Modules*891/4" (2267)
24" Cooktop**/15" Module*375/8" (956)
30" Cooktop/15" Module*44" (1118)
30" Cooktop/(2) 15" Modules*59" (1473)
36" Cooktop/15" Module*50" (1270)
*Dimensions apply to CI152TF/S, CE152TF/S, CG152TF/S, SM15TF/S,
FM15TF/S, GM15TF/S, TM15TF/S and MM15TF/S.
5
**23
/8" actual product width.
W
21/2"
(64) min
21/2"
(64) min
Countertop cutout
W
CUTOUT
WIDTH
FRONT OF COUNTERTOP
wolfappliance.com | 83
191/2"
(495)
CUTOUT
DEPTH
Page 84
MODULE COOKTOPS
Planning Information
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on
the following pages. A separate circuit servicing only this
appliance is required.
When multiple cooktops or modules are installed side by
side, each must have its own separate electrical supply.
Steamer and fryer modules require a method for draining
hot water and oil. For the steamer module, options include
5
connecting a drain hose from the
/8" (16) outlet tied into
an existing drain, a separate drain with freefall, or placing a
heat-resistant receptacle under the drain outlet. For the fryer
module, the drain outlet must be accessible to drain oil into
a heat-resistant receptacle.
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certied, 3'
(19)
ID exible metal appliance connector is recommended.
(.9 m) long,
1
/2" (13) or 3/4"
When multiple gas cooktops or modules are installed side
by side, they can receive their gas supply from a common
line. However, each unit must have its own regulator
installed between the mainline and the cooktop or module.
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
will function up to 8,600'
in altitude without adjustment and LP gas cooktops
(2621 m). If the installation exceeds
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
GAS REQUIREMENTS
Gas Supply
Gas Inlet
NATURAL GASWC
Supply Pressure5" (12.5 mb)
Min Line Pressure7" (17.5 mb)
Max Regulator Pressure14" (34.9 mb), .5 psi (3.5 kPa)
LP GASWC
Supply Pressure10" (25 mb)
Min Line Pressure11" (27.4 mb)
Max Regulator Pressure14" (34.9 mb), .5 psi (3.5 kPa)
3
/4" ID line
1
/2" NPT male
84 | Wolf Customer Care 800.222.7820
Page 85
MODULE COOKTOPS
SIDE
NO
combus
Induction / Electric Module
STANDARD INSTALLATION
21/2" (64)
13"
(330)
18"
(457)
COUNTERTOP CUTOUT
2"
(51)
14"
(356)
30"
(762)
E
191/2"
(495)
21/2" (64)
36" (914) min
FLOOR TO
COUNTERTOP
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
FRONT VIEW
wolfappliance.com | 85
Page 86
MODULE COOKTOPS
NO
combus
SIDE
Steamer Module
STANDARD INSTALLATION
21/2" (64) min
13"
(330)
77/8"
(200)
18"
(457)
14"
(356)
COUNTERTOP CUTOUT
30"
(762)
7"
(178)
(314)
(152)
DRAIN
OUTLET
123/8"
E
6"
191/2"
(495)
21/2" (64) min
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
FRONT VIEW
WARNING
The steamer module must be installed at least 15" (381)
from a fryer module.
86 | Wolf Customer Care 800.222.7820
Page 87
MODULE COOKTOPS
SIDE
NO
combus
Fryer Module
STANDARD INSTALLATION
21/2" (64) min
13"
(330)
77/8"
(200)
18"
(457)
14"
(356)
COUNTERTOP CUTOUT
30"
(762)
7"
(178)
(314)
(152)
DRAIN
OUTLET
123/8"
E
6"
191/2"
(495)
21/2" (64) min
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
FRONT VIEW
WARNING
The fryer module must be installed at least 15" (381)
from any open-ame cooking device or a steamer
module.
wolfappliance.com | 87
Page 88
MODULE COOKTOPS
SIDE
NO
combus
Grill / Teppanyaki Module
STANDARD INSTALLATION
21/2" (64) min
13"
(330)
18"
(457)
14"
(356)
COUNTERTOP CUTOUT
30"
(762)
7"
(178)
E
191/2"
(495)
21/2" (64) min
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
FRONT VIEW
88 | Wolf Customer Care 800.222.7820
Page 89
MODULE COOKTOPS
SIDE
NO
combus
Gas / Multifunction Module
STANDARD INSTALLATION
21/2" (64)
13"
(330)
18"
(457)
14"
(356)
COUNTERTOP CUTOUT
30"
(762)
7"
(178)
EG
191/2"
(495)
21/2" (64)
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
FRONT VIEW
wolfappliance.com | 89
Page 90
COFFEE SYSTEMS
90 | Wolf Customer Care 800.222.7820
Page 91
COFFEE SYSTEMS
Coffee Systems
Make professional-quality coffee, espresso, cappuccino,
latte, and more. The Wolf coffee system automatically
steams and foams the milk perfectly. The water temperature
and brew strength are adjustable. It uses either whole-bean
or ground coffee. The design pairs beautifully, either sideby-side or in a tower application, with other Wolf products
such as the convection steam oven. Coffee systems can be
installed in a standard or ush inset application. All 30" trim
options are based on model EC24/B.
COFFEE SYSTEMS
24" MODELS
EC24/B
TRANSITIONAL
30" M SERIES TRIM
PROFESSIONAL
30" M SERIES TRIM
CONTEMPORARY
EC24/S
30" E SERIES TRIM
30" E SERIES TRIM
30" M
/E SERIES TRIM
wolfappliance.com | 91
Page 92
COFFEE SYSTEMS
Coffee System
DIMENSIONS
177/8"
(454)
7
(22)
/8"
W
WIDTH
18" (457)
BEHIND FRAME
WIDTH
24" Model231/2" (597)
30" Trim297/8" (759)
UNIT
FULL EXTENSION
W
181/4"
(464)
92 | Wolf Customer Care 800.222.7820
Page 93
COFFEE SYSTEMS
Planning Information
The coffee system can be installed in a standard or ush
inset application. All 30" trim options are based on model
EC24/B. The sides of the cabinetry opening must be adequate to support installation of the mounting slides. Refer to
the illustration below.
Finish the edges of the opening. They may be visible when
the unit is slid forward.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
1
For ush inset installations, a minimum
/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORTMIN
Coffee System100 lb (45 kg)
TRIM OVERLAP24" MODEL30" TRIM
Top
Bottom0" (0)0" (0)
Sides
3
/16" (5)
11
/16" (18) 37/8" (98)
3
/16" (5)
COMBINATION INSTALLATION
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supplygrounded, 120 VAC, 60 Hz
Service15 amp dedicated circuit
Receptacle3-prong grounding-type
Power Cord6'
(1.8 m)
To install a coffee system above a cup warming drawer, one
opening for both units must be specied. To achieve the
minimum reveal between the units, place the coffee system
support rails on top of the cup warming drawer, then secure
the rails to the sides of the cabinet. Any material between
the units will increase the horizontal reveal.
14"
(356)
3
/4" (19)
TYPICAL
Side support
10"
(254)
wolfappliance.com | 93
Page 94
SIDE
NOTE: 24"
COFFEE SYSTEMS
Coffee System
STANDARD INSTALLATION
SLIDE
SUPPORT
OPENING
TOP VIEW
219/16"
(548)
DEPTH
1711/16" (449)
SLIDE
SUPPORT
VIEW
(610) model and model with 30" (762) trim require the same opening dimensions.
OPENING
HEIGHT
OPENING WIDTH
24" Model221/8" (562)
30" Trim221/8" (562)
W
E
W
OPENING WIDTH
FRONT VIEW
94 | Wolf Customer Care 800.222.7820
Page 95
SIDE
*W
**
COFFEE SYSTEMS
Coffee System
FLUSH INSET INSTALLATION
SLIDE
SUPPORT
(460)
181/8"
FLUSH INSET
HEIGHT**
SLIDE
SUPPORT
7
/8" (22)
TOP VIEW
5
/16"(8)
A
FLUSH INSET WIDTH**
1
/8" (3)
E
W
23" (584)
FLUSH
INSET
DEPTH
FINISHED
CLEATS*
VIEW
ill be visible and should be finished to match cabinetry.
Dimension provides minimum reveals.
FLUSH INSET WIDTH
24" Model233/4" (603)
WA
13
/16" (21)
30" Trim301/8" (765)4" (102)
FRONT VIEW
wolfappliance.com | 95
Page 96
CUP WARMING DRAWERS
96 | Wolf Customer Care 800.222.7820
Page 97
CUP WARMING DRAWERS
Cup Warming Drawers
Wolf cup warming drawers preheat cups so hot beverages
stay hot longer. The temperature is adjustable. Two model
options match the look of Wolf stainless and black coffee
systems. The cup warming drawer can be installed in a
standard or ush inset application.
CUP WARMING DRAWERS
CW24/S
Stainless
CW24/B
Black
DIMENSIONS
231/2" (597)
DRAWER
FULL EXTENSION
51/2"
(140)
19"
(483)
7
/8"
(22)
21" (533)
BEHIND FRAME
wolfappliance.com | 97
Page 98
CUP WARMING DRAWERS
Planning Information
The cup warming drawer can be installed in a standard or
ush inset application. Finish the edges of the opening.
They may be visible when the drawer is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
1
For ush inset installations, a minimum
/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORTMIN
Cup Warming Drawer75 lb (34 kg)
TRIM OVERLAP
Top0" (0)
Bottom0" (0)
Sides
11
/16" (18)
COMBINATION INSTALLATION
To install a cup warming drawer below a coffee system, one
opening for both units must be specied. To achieve the
minimum reveal between the units, place the coffee system
support rails on top of the cup warming drawer, then secure
the rails to the sides of the cabinet. Any material between
the units will increase the horizontal reveal.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supplygrounded, 120 VAC, 60 Hz
Service10 amp dedicated circuit
Receptacle3-prong grounding-type
Power Cord3'
(.9 m)
98 | Wolf Customer Care 800.222.7820
Page 99
CUP WARMING DRAWERS
SIDE
Cup Warming Drawer
STANDARD INSTALLATION
OPENING
TOP VIEW
221/2"
(572)
DEPTH
ANTI-TIP BLOCK
VIEW
51/2" (140)
OPENING HEIGHT
E
221/8" (562)
OPENING WIDTH
FRONT VIEW
wolfappliance.com | 99
Page 100
SIDE
*W
**
CUP WARMING DRAWERS
Cup Warming Drawer
FLUSH INSET INSTALLATION
7
/8" (22)
231/2" (597)
TOP VIEW
FLUSH
INSET
DEPTH
FINISHED
CLEATS*
ANTI-TIP BLOCK
53/4" (146)
FLUSH INSET
VIEW
ill be visible and should be finished to match cabinetry.
Dimension provides minimum reveals.
HEIGHT**
1
/8" (3)
13
/16"
(21)
233/4" (603)
FLUSH INSET WIDTH**
FRONT VIEW
1
/8" (3)
E
100 | Wolf Customer Care 800.222.7820
Loading...
+ hidden pages
You need points to download manuals.