Winegard RV-7542, RV-0752, RV-0751 User Manual

STEP 4. Install connectors on downlead and
set 2 cable as shown in Figure 5. Attach downlead cable to jack on wall plate/power supply marked antenna as shown in Figure 4. Attach cable going to set 2 outlet to jack on power supply marked SET 2. Attach cable coming from cable input to jack on power supply marked CABLE.
Auxiliary (Satellite Receiver)
Set 2
Antenna
Cable
Figure 4
STEP 5. Mount power supply in wall with
screws provided and attach TV set cable to jack on front. Connect band separator to VHF and UHF antenna terminals of TV set, if required. Press switch on front of outlet and check that light is on.
OPERATION: To receive cable signals from outdoor receptacle: Press switch to (OFF)
position. Light on wallplate will go (OFF) showing that power is no longer connected to the antenna and the TV sets are receiving signals from outdoor receptacle. To receive signals from antenna: Press switch to (ON) position. Light on wall plate will come (ON) showing that power is connected to the antenna and theTV sets are receiving signals from the antenna. NOTE: Make sure TV antenna is in the (UP) position and pointed at the station
desired. To receive satellite signal, attach
coax from receiver/antenna to Auxiliary jack on wall plate.
INSTALLING FC-5910
CONNECTORS ON COAX CABLE
1.
Outer Cover
2.
3.
STEP 1: Strip outer cover back 1/2"* from end of cable. Fray braid back as far as outer cover will allow. STEP 2: Trim braid close to outer cover and remove 1/4"* of inner insulation being careful not to nick center conductor. Make sure no foil or braid can touch center conductor. STEP 3: Slide connector tip between braid and inner insulation (braid and foil, on foil shield cable) and push connector on cable as far as it will go. Crimp built-in ferrule with proper crimping tool. Hex connector requires hex crimping tool. Do Not crush cable out­of-round. * If installing in very hot weather, increase dimensions 1/8".
WINEGARD MOBILE PRODUCTS LIMITED WARRANTY
Winegard Company warrants this product against defects in materials or workmanship for a period of two (2) years from the date of original purchase. During year one (1) of such warranty, Winegard Company will also pay authorized labor costs to an authorized Winegard dealer to repair or replace defective products. No warranty claim will be honored unless at the time the claim is made, Customer presents proof of purchase to an authorized Winegard dealer (to locate the nearest authorized Winegard dealer, contact Winegard Company, 3000 Kirkwood Street, Burlington, Iowa 52601, Telephone 800-288-8094 or visit www.winegard.com). Customer must provide proof of purchase with a dated sales receipt for the Winegard product to verify the product is under warranty. If the date of purchase cannot be verified, the warranty period shall be considered to begin thirty (30) days after the date of manufacture.
If a defect in material or workmanship is discovered, Customer may take the product to an authorized Winegard dealer for service. Customer must provide proof of purchase to verify the product is under warranty. If the product is brought to an authorized Winegard dealer for service prior to expiration of year one (1) of the warranty period and a defect in material or workmanship is verified by Winegard Technical Services, Winegard Company will cover the Winegard dealer’s labor charges for warranty service. The Winegard dealer must contact Winegard Technical Services in advance for
Crimp Here
(2 YEARS PARTS; 1 YEAR LABOR)
1/2" *
Inner Insulation
¼" *
Center Conductor
Figure 5
pre-approval of the service. Approval of the service is at the sole discretion of Winegard Company.
Alternatively, Customer may ship the product prepaid to Winegard Technical Services (located at 3111 Kirkwood Street, Burlington, Iowa 52601, Telephone 800-788-4417). Customer must return the product along with a brief description of the problem and provide Winegard Technical Services with Customer’s name, address, and phone number. Customer must also provide proof of purchase to verify the product is under warranty. If the product is returned before the expiration of the warranty period, Winegard Company will (at its option) either repair or replace the product.
This Limited Warranty does not apply if the product has been damaged, deteriorates, malfunctions or fails from: improper installation, misuse, abuse, neglect, accident, tampering, modification of the product as originally manufactured by Winegard in any manner whatsoever, removing or defacing any serial number, usage not in accordance with product instructions or acts of nature such as damage caused by wind, lightning, ice or corrosive environments such as salt spray and acid rain. This Limited Warranty also does not apply if the product becomes unable to perform its’ intended function in any way as a result of the television signal provider making any changes in technology or service.
any product to Winegard Company or Winegard Warranty Services under this warranty policy. Please call our Technical Services Department at 800-788-4417 or send an e-mail to
warranty@winegard.com to obtain the RMA number. Please furnish
the date of purchase when requesting an RMA number. Enclose the product in a prepaid package and write the RMA number in large, clear letters on the outside of the package. To avoid confusion or misunderstanding, a shipment(s) without an RMA number(s) or an unauthorized return(s) will be refused and returned to Customer freight collect.
FOR ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, MADE BY ANY OTHER PERSON.
OR STATUTORY INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY ARE LIMITED TO THE TWO YEAR PERIOD OF THIS WARRANTY.
the exclusion of limitation of incidental or consequential damages, the above limitations or exclusions do not apply.
warranty lasts, or the exclusion of limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
may also have other rights that may vary from state to state.
RETURN AUTHORIZATION POLICY
A Return Material Authorization (RMA) is required prior to returning
WINEGARD COMPANY DOES NOT ASSUME ANY LIABILITIES
ALL OTHER WARRANTIES WHETHER EXPRESS, IMPLIED
In states that do not allow limitations on implied warranties, or
Some states do not allow limitations on how long an implied
This warranty gives Customer specific legal rights. Customer
SATELLITE RECEIVER WARRANTY:
See manufacturer’s limited warranty policy.
WS-MOBWARREV2 Rev. 1/10
INSTRUCTIONS
MODEL RV-0751 (almond bulk)
MODEL RV-0752 (white bulk) MODEL RV-7542 (white single)
Made in U.S.A.
RV WALL PLATE/
POWER SUPPLY
This unit is equipped with a polyswitch,
(current limiting device), which will shut down +12VDC if there is a direct short between antenna and power supply. Green indicator light will not light. Once short is eliminated, device will reset itself in approximately 2 minutes.
Wall plate/power supply to operate Winegard RV antenna with outdoor receptacle for TV set and cable or satellite input. Wall plate/power supply provides +12 VDC to antenna as well as antenna signals to two TV sets. Cable input from outdoor receptacle connects to wall plate and may be switched so either antenna or cable signals may be watched. See applications.
There is also an auxiliary jack for a third signal.
NOTE: THIS UNIT IS NOT AN AMPLIFIER. USE ONLY WITH A WINEGARD AMPLIFIED RV ANTENNA.
3000 KIRKWOOD ST., BURLINGTON, IA 52601-2000
DESCRIPTION
WINEGARD COMPANY
Printed in U.S.A. 2451487 REV2 1/10
WARNING: Use of this on/off power switch with any product other than Winegard amplified RV antenna, could result in fire or other damage.
APPLICATIONS AND
ALTERNATE CONNECTIONS
Antenna
Cable Input
Antenna Input
Cable Input
Example 1
ON/OFF Switch
Outdoor Receptacle WA-1010
TV Outlet
Set 2
Set 1
Antenna Input
ON/OFF Switch
Antenna
Antenna Input
ON/OFF Switch
Antenna
Set 1
Set 1
Cable Input
Set 2
Example 2
Cable Input
Set 2
Example 3
Outdoor Receptacle WA-1010
TG-7221
Outdoor Receptacle WA-1010
TV Outlet
SP-1002 Splitter
TG-7221
INSTRUCTIONS
STEP 1. Select location for wall plate and
patio receptacle if required. Run coax cables between locations and install connectors on each end. Mark cables so they may be identified. Antenna downlead and +12 VDC will also be needed at inside wall plate/power supply location.
STEP 2. The wall plate assembly may be flush mounted in most standard electrical boxes. To flush mount, cut a hole in wall to fit the box. Route all cables to the wall plate and other outlets required at this time. The Auxiliary
jack is designed for the use of satellite receivers, etc. requiring direct line input.
WHEN CONNECTING CABLE OR WIRES
BE SURE SWITCH IS IN OFF POSITION.
STEP 3. Make +12 VDC connection by
running two #12 wires between the wall plate and +12 VDC source. Install terminals on wires from +12 VDC source as shown in Figure 1. Crimp terminals with Craftsman type 4 crimping tool or equivalent. Push wires onto tabs on terminal board as shown in Figure 2. If in doubt as to the polarity of the wires, connect them temporarily to tabs on circuit board and press switch on front of outlet. If light comes on, polarity is correct. See Figure 3.
Connector Insulation
Figure 1
Figure 2
Set 1
Figure 3
Crimp Here
1/4"
Connector Ferrule
#12 Wire
Remove 1/4" of insulation from #12 wire.
+12 VDC
Ground
Auxilliary
Loading...