Wilo EMU FA + FK 17.1, EMU FA + FK 34, EMU FA + FK 202, EMU FA + FK 42 Installation And Operating Instructions Manual

Pioneering for You
·
Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42
6074704 • Ed.02/2017-06
en Installation and operating instructions
Installation and operating instructions Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 3
Table of contents
1 General information ................................................................................................................................................................. 5
1.1 About these instructions ..................................................................................................................................................................................5
1.2 Copyright ............................................................................................................................................................................................................5
1.3 Subject to change..............................................................................................................................................................................................5
1.4 Warranty..............................................................................................................................................................................................................5
2 Safety......................................................................................................................................................................................... 5
2.1 Identification of safety instructions................................................................................................................................................................5
2.2 Personnel qualifications....................................................................................................................................................................................7
2.3 Electrical work ....................................................................................................................................................................................................7
2.4 Monitoring devices ............................................................................................................................................................................................7
2.5 Use in fluids hazardous to health ....................................................................................................................................................................8
2.6 Transport.............................................................................................................................................................................................................8
2.7 Installing/dismantling........................................................................................................................................................................................8
2.8 During operation ................................................................................................................................................................................................8
2.9 Maintenance tasks.............................................................................................................................................................................................9
2.10 Operating fluid ...................................................................................................................................................................................................9
2.11 Operator responsibilities...................................................................................................................................................................................9
3 Application/use......................................................................................................................................................................... 9
3.1 Intended use.......................................................................................................................................................................................................9
3.2 Improper use....................................................................................................................................................................................................10
4 Product description................................................................................................................................................................ 10
4.1 Design...............................................................................................................................................................................................................10
4.2 Monitoring devices .........................................................................................................................................................................................11
4.3 Operating modes............................................................................................................................................................................................. 12
4.4 Operation with frequency converter............................................................................................................................................................ 12
4.5 Operation in an explosive atmosphere ........................................................................................................................................................12
4.6 Rating plate...................................................................................................................................................................................................... 12
4.7 Type key........................................................................................................................................................................................................... 13
4.8 Scope of delivery............................................................................................................................................................................................. 14
4.9 Accessories ......................................................................................................................................................................................................14
5 Transportation and storage................................................................................................................................................... 14
5.1 Delivery............................................................................................................................................................................................................. 14
5.2 Transport.......................................................................................................................................................................................................... 14
5.3 Storage .............................................................................................................................................................................................................15
6 Installation and electrical connection .................................................................................................................................. 15
6.1 Personnel qualifications................................................................................................................................................................................. 16
6.2 Installation types............................................................................................................................................................................................. 16
6.3 Operator responsibilities................................................................................................................................................................................ 16
6.4 Installation .......................................................................................................................................................................................................16
6.5 Electrical connection...................................................................................................................................................................................... 22
7 Commissioning........................................................................................................................................................................ 26
7.1 Personnel qualifications................................................................................................................................................................................. 26
7.2 Operator responsibilities................................................................................................................................................................................ 26
7.3 Direction of rotation check (for three-phase current motors only)........................................................................................................ 26
7.4 Operation in an explosive atmosphere ........................................................................................................................................................27
7.5 Before switching on........................................................................................................................................................................................ 27
7.6 Switch on and off............................................................................................................................................................................................28
7.7 During operation ............................................................................................................................................................................................. 28
8 Decommissioning/dismantling.............................................................................................................................................. 29
8.1 Personnel qualifications................................................................................................................................................................................. 29
8.2 Operator responsibilities................................................................................................................................................................................ 29
8.3 Decommissioning............................................................................................................................................................................................ 29
8.4 Removal............................................................................................................................................................................................................ 30
4 WILO SE 2017-06
9 Maintenance and repair.......................................................................................................................................................... 31
9.1 Personnel qualifications................................................................................................................................................................................. 32
9.2 Operator responsibilities................................................................................................................................................................................ 32
9.3 Labelling of the screw plugs.......................................................................................................................................................................... 32
9.4 Operating fluid ................................................................................................................................................................................................ 32
9.5 Maintenance intervals.................................................................................................................................................................................... 33
9.6 Maintenance measures ..................................................................................................................................................................................33
9.7 Repairs ..............................................................................................................................................................................................................37
10 Faults, causes and remedies ..................................................................................................................................................40
11 Spare parts............................................................................................................................................................................... 43
12 Disposal.................................................................................................................................................................................... 43
12.1 Oils and lubricants........................................................................................................................................................................................... 43
12.2 Protective clothing .........................................................................................................................................................................................43
12.3 Information on the collection of used electrical and electronic products.............................................................................................. 43
13 Appendix.................................................................................................................................................................................. 43
13.1 Tightening torques .........................................................................................................................................................................................43
13.2 Operation with frequency converter............................................................................................................................................................ 44
13.3 Ex rating ........................................................................................................................................................................................................... 45
General information en
Installation and operating instructions Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 5
1 General information
1.1 About these instructions
These installation and operating instructions are an integral part of the product. Read these instructions before commencing work and keep them in an accessible place at all times. Strict adherence to these instructions is a precondition for the intended use and correct operation of the product. All information and markings on the product must be observed.
The language of the original operating instructions is German. All other languages of these instructions are translations of the original operating instructions.
1.2 Copyright
These installation and operating instructions have been copyrighted by the manufac­turer. Contents, of whatever type, which may not be reproduced or distributed, or used for purposes of competition and shared with others.
1.3 Subject to change
The manufacturer reserves the right to make technical modifications to the device or individual components. The illustrations used may differ from the original and are in­tended as an example representation of the device.
1.4 Warranty
The specifications in the current “General Terms and Conditions” apply to the warranty and the warranty period. These can be found at www.wilo.com/legal
Any deviations must be contractually agreed and shall then be given priority.
Claim to warranty
If the following points are complied with, the manufacturer is obligated to rectify every
qualitative or constructive flaw: ▪The defects are reported in writing to the manufacturer within the warranty period. ▪Application according to intended use. ▪All monitoring devices are connected and tested before commissioning.
Exclusion from liability
Exclusion from liability excludes all liability for personal injury, material damage or fin-
ancial losses. This exclusion ensues as soon as one of the following applies: ▪Inadequate configuration due to inadequate or incorrect instructions by the operator or
the client ▪Non-compliance with installation and operating instructions ▪Improper use ▪Incorrect storage or transport ▪Incorrect installation or dismantling ▪Insufficient maintenance ▪Unauthorised repairs ▪Inadequate construction site ▪Chemical, electrical or electro-chemical influences ▪Wear
2 Safety
This chapter contains basic information which must be adhered to during the individual
phases of the life cycle. Failure to follow the installation and operating instructions will
result in injuries to persons, damage to the environment and the device and result in the
loss of any claims for damages. Failure to follow the instructions can result in the fol-
lowing risks: ▪Danger to persons due to electrical, mechanical and bacteriological factors as well as
electromagnetic fields ▪Environmental risks due to leakage of hazardous substances ▪Property damage ▪Failure of important functions of the product
Additionally, the instructions and safety instructions in the other chapters must be
observed!
2.1 Identification of safety instruc­tions
These installation and operating instructions set out safety instructions for preventing personal injury and damage to property. These safety instructions are shown differ­ently:
▪Safety instructions relating to personal injury start with a signal word, are preceded by
a corresponding symbol and are shaded in grey.
en Safety
6 WILO SE 2017-06
DANGER Type and source of the danger!
Consequences of the danger and instructions for avoidance.
▪Safety instructions for property damage start with a signal and are displayed without a
symbol.
CAUTION Type and source of the danger!
Consequences or information.
Signal words
DANGER!
Failure to observe the safety instructions will result in serious injuries or death!
WARNING!
Failure to follow the instructions can lead to (serious) injuries!
CAUTION!
Failure to follow the instructions can lead to property damage and a possible total loss.
NOTE!
Useful information on handling the product.
Markups
Prerequisite
1. Work step/list
⇒ Information/instructions
▶ Result
Symbols
These instructions use the following symbols:
Danger of electric voltage
Danger of bacterial infection
Danger of explosion
Danger – explosive atmosphere
General warning symbols
Warning of cutting injuries
Warning of hot surfaces
Warning of high pressure
Warning of suspended loads
Safety en
Installation and operating instructions Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 7
Personal protective equipment: Wear a safety helmet
Personal protective equipment: Wear foot protection
Personal protective equipment: Wear hand protection
Personal protective equipment: Wear mouth protection
Personal protective equipment: Wear safety goggles
Autonomous work prohibited! A second person must be present.
Useful information
2.2 Personnel qualifications
Personnel must: ▪Be instructed in the locally applicable accident prevention regulations. ▪Have read and understood the installation and operating instructions.
Personnel must have the following qualifications: ▪Electrical work: Electrical work must be carried out by a qualified electrician (in accord-
ance with EN50110-1). ▪Installation-/dismantling: The technician must be trained in the use of the necessary
tools and mounting materials for the relevant construction site. ▪Maintenance tasks: The technician must be familiar with the use of operating fluids and
their disposal. In addition, the technician must have basic knowledge of mechanical en-
gineering.
Definition of “qualified electrician”
A qualified electrician is a person with appropriate technical education, knowledge and
experience who can identify and prevent electrical hazards.
2.3 Electrical work
▪A qualified electrician must carry out the electrical work. ▪When connecting to the mains, comply with the locally applicable laws and regulations
of the local energy supply company. ▪Before commencing work, disconnect the device from the mains and secure it against
being switched on again without authorisation. ▪Personnel is trained on the execution of the electrical connection and the options for
switching off the device. ▪Comply with the technical specifications contained in these installation and operating
instructions and on the rating plate. ▪Earth the device. ▪Observe the manufacturer’s specifications when connecting to electrical switching sys-
tems. ▪Comply with the specifications on electro-magnetic compatibility when connecting
electronic start-up controllers (e.g. soft starter or frequency converter). If required, take
into account special measures (e.g. shielded cables, filters etc.). ▪Replace defective power supply cables immediately. Contact customer service.
2.4 Monitoring devices
The following monitoring equipment must be provided on-site:
Circuit breaker
The size of the circuit breakers conforms to the rated current of the pump. The switch-
ing characteristics should comply with group B or C. Observe local regulations.
en Safety
8 WILO SE 2017-06
Motor protection switch
Make provision for an on-site motor protection switch for devices without a plug! The minimum requirement is a thermal relay/motor protection switch with temperature compensation, differential triggering and anti-reactivation device in accordance with the local regulations. In case of sensitive mains, make provision for the installation on­site of other protective equipment (e.g. overvoltage, undervoltage or phase failure re­lay, etc.).
Residual-current device (RCD)
Comply with the regulations of the local energy supply company! The use of a residual­current device is recommended. If persons come into contact with the device and conductive fluids, secure the connec­tion with a residual-current device (RCD).
2.5 Use in fluids hazardous to health
There is a danger of bacterial infection when using the device in fluids hazardous to health! Thoroughly clean and disinfect the device after dismantling and prior to further use. The operator must ensure the following:
▪The following protective equipment is provided and worn when cleaning the device:
– Closed safety goggles – Breathing mask – Protective gloves
▪All persons are informed about the fluid, the associated danger and its correct handling!
2.6 Transport
▪The following protective equipment must be worn:
– Safety shoes
– Safety helmet (when using lifting equipment) ▪Always hold the handle to transport the device. Never pull the power supply cable! ▪Only use legally specified and approved lifting gear. ▪Select the lifting gear based on the available conditions (weather, attachment point,
load, etc.). ▪Always attach the lifting gear to the attachment points (handle or lifting eyelet). ▪The stability of the lifting equipment must be ensured during operation. ▪When using lifting equipment, a second person must be present to coordinate the pro-
cedure if required (e.g. if the operator’s field of vision is blocked). ▪Persons are not permitted to stand beneath suspended loads. Do not lift loads above
workplaces, on which people are present.
2.7 Installing/dismantling
▪Wear the following protective equipment:
– Safety shoes
– Safety gloves against cuts
– Safety helmet (when using lifting equipment) ▪Locally applicable laws and regulations for work safety and accident prevention must be
complied with. ▪Disconnect the device from the mains and secure it against being switched on again
without authorisation. ▪All rotating parts must be at a standstill. ▪Provide adequate aeration in closed rooms. ▪When working in chambers and closed spaces, a second person must be present for
safety reasons. ▪Take immediate countermeasures if there is a build-up of toxic or suffocating gases! ▪Clean the device thoroughly. Disinfect devices that are used in fluids hazardous to
health! ▪Make sure that there is no risk of explosion when carrying out any type of welding work
or work with electrical devices.
2.8 During operation
▪Wear the following protective equipment:
– Safety shoes
– Ear protection (in accordance with the notice of the work regulations) ▪Work area of the device is not an recreational area. No persons are allowed in the work
area during operation. ▪The operator must immediately report any faults or irregularities to their line manager. ▪If safety-endangering defects occur, the operator must immediately deactivate the
device:
– Malfunction of the safety and monitoring equipment
– Damage to the housing parts
– Damage to the electrical equipment ▪Never reach into the suction port. The rotating parts can crush and sever limbs.
Application/use en
Installation and operating instructions Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 9
▪If the motor emerges during operation as well as in dry well installation, the motor
housing can reach temperatures in excess of 40°C. ▪Open all gate valves in the piping on the suction and pressure side. ▪Ensure minimum water submersion through dry-running protection. ▪Under normal operating conditions, the sound pressure level of the device is below
85dB(A). However, the actual sound-pressure level depends on several factors:
– Installation depth
– Installation
– Fixation of accessories and pipe
– Duty point
– Immersion depth ▪If the device is operated under normal operating conditions, the operator must measure
the sound pressure. Ear protection must be worn for sound pressure level of 85dB(A)
and above and this must be noted in the work regulations!
2.9 Maintenance tasks
▪Wear the following protective equipment:
– Closed safety goggles
– Safety shoes
– Safety gloves against cuts ▪Always carry out maintenance tasks outside the operating space/installation site. ▪Only carry out maintenance tasks mentioned in this installation and operating instruc-
tions. ▪Only original parts from the manufacturer may be used for maintenance and repairs.
Use of parts other than the original parts releases the manufacturer from any liability. ▪Collect any leakage of fluid and operating fluid immediately and dispose of it according
to the locally applicable guidelines. ▪Store tools at the designated locations. ▪After completing work, reattach all safety and monitoring devices and check that they
function properly.
Changing operating fluid
In case of a defect, a pressure of several bar can build up in the motor! This pressure
escapes when the screw plugs are opened. If screw plugs are opened without due cau-
tion, they can be ejected at high speed! To avoid injuries, observe the following instruc-
tions: ▪Adhere to the prescribed sequence of work steps. ▪Unscrew the screw plugs slowly, but never unscrew them completely. As soon as the
pressure escapes (audible whistling or hissing of air), stop turning the screw plug any
further.
WARNING!Hot operating fluid can also spray out when the pressure is escaping. This
can result in scalding! To avoid injuries, allow the motor to cool down to the ambient
temperature before carrying out any work!
▪When the pressure has completely dissipated, fully unscrew the screw plug.
2.10 Operating fluid
Motor in the motor compartment and the sealing chamber is filled with white oil or a
water-glycol-mixture. Operating fluids must be replaced during regular maintenance
work and disposed off according to the local guidelines.
2.11 Operator responsibilities
▪Installation and operating instructions must be in a language which the personnel can
understand. ▪Make sure that the personnel is relevantly trained for the specified work. ▪Provide the necessary protective equipment and make sure that the personnel wears it. ▪Safety and information signs mounted on the device must be always legible. ▪Train the personnel pertaining to the functioning of the system. ▪Eliminate risk from electrical current. ▪Equip hazardous components inside the system with an on-site guard. ▪Identify and cordon off the work area. ▪To ensure safe working practice, define the responsibilities of the employees.
Children and persons below 16years or with reduced physical, sensory or mental capa-
cities or limited experience are prohibited from handling the device! A technician must
supervise persons below 18years!
3 Application/use
3.1 Intended use
Submersible pumps are suitable for pumping: ▪Sewage containing faeces (in accordance with EN12050-1)
en Product description
10 WILO SE 2017-06
▪Wastewater (with small amounts of sand and gravel) ▪Process sewage ▪Fluids with dry matter up to max. 8%
3.2 Improper use
DANGER Explosion due to pumping of explosive fluids!
Pumping of highly flammable and explosive fluids (gasoline, kerosene, etc.) in pure form is strictly prohibited. There is a risk of fatal injury due to explosion! The pumps are not designed for these fluids.
DANGER Danger due to fluids hazardous to health!
If the pump is used in fluids hazardous to health, decontaminate the pump after dis­mantling and before carrying out any other work! There is danger to life! Observe the specifications in the work regulations! The operator must make sure that the per­sonnel has received and read the work regulations!
The submersible pumps must not be used for pumping:
▪Drinking water ▪Fluids containing hard components (such as stones, wood, metal, etc.) ▪Fluids containing large quantities of abrasive contents (e.g. sand, gavel)
Intended use also includes compliance with this manual. Any other use is regarded as non-compliant with the intended use.
4 Product description
4.1 Design
Submersible sewage pump as submersible monobloc unit for continuous duty in wet well and dry well installation.
P-Typ M-Typ
S/N
MFY
U Q IMø
I H OTS/E
IST Cos TPFmax
P SF
F ISF IP
N MC
P-Typ M-Typ
S/N
MFY
U Q IMø
I H OTS/E
ISTCos TPF
max
P SF
F ISF IP
N MC
2 1
4
6
5
6
7
7
1
2
3
Fig.1: Overview
1 Power supply cable 2 Handle/attachment point 3 Motor 4 Seal housing 5 Hydraulics housing 6 Suction port 7 Pressure port
4.1.1 Hydraulics
Centrifugal hydraulics with different impeller shapes, horizontal flange connection on the pressure side, inspection cover as well as casing and impeller wear rings. The hydraulics are not self-priming, in other words, the fluid must flow in either auto­matically or with supply pressure.
Impeller forms
The individual impeller shapes depend on the size of the hydraulics and not every im­peller shape is available for every hydraulic system. The following is an overview of the
different impeller shapes: ▪W = Vortex impeller ▪E = Single-channel impeller ▪Z = Two-channel impeller ▪D = Three-channel impeller ▪V = Four-channel impeller ▪T = Closed SOLID impeller ▪G = Half open SOLID impeller
Product description en
Installation and operating instructions Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 11
Inspection cover (depending on the hydraulics)
Additional opening on the hydraulics housing. This opening is used to remove clogging in the hydraulics.
Casing and impeller wear rings (depending on the hydraulics)
The suction port and impeller are subjected to the most stress when pumping. In the case of channel impellers, the gap between the impeller and the suction port is an im­portant factor for a constant delivery rate. The larger the gap between the impeller and the suction port, the higher the losses in the delivery rate and the risk of clogging in­creases. In order to ensure long and efficient operation of the hydraulics, an impeller wear ring and/or casing wear ring is installed depending on the impeller and the hy­draulics.
▪Impeller wear ring
The impeller wear ring is attached to the channel impellers and protects the incoming flow edge of the impeller.
▪Casing wear ring
The casing wear ring is installed in the suction port of the hydraulics and protects the incoming flow edge in the centrifugal chamber.
The two components can be replaced easily when worn.
4.1.2 Motor
In the three-phase current version, self-cooling submersible motors are used as the drive. The motor can be used in continuous duty both immersed and non-immersed. Continuous duty is also possible in dry well installation. The roller bearings are perman­ently lubricated, which means they are maintenance-free. The connection cable has bare cable ends and the standard length is 10m. The cable length can be adapted ac­cording to the order.
4.1.3 Cooling system
The motor has an active cooling system. For the cooling, the motor is filled with medi­cinal white oil. The coolant is circulated by an impeller. The impeller is driven by the motor shaft. The waste heat is transferred directly to the fluid via the cooling flange. The cooling system itself is not pressurised.
4.1.4 Seal
The seal for the fluid and the motor compartment is made via two mechanical seals. The
two mechanical seals are arranged in two different ways: ▪Version “G”: two separate mechanical seals ▪Version “K”: two mechanical seals in a block seal cartridge made of stainless steel
The sealing chamber between the mechanical seals is filled with medicinal white oil and
accommodates any possible leakage of the mechanical seal on the fluid side.
4.1.5 Material
The following materials are used in the standard version: ▪Pump housing: EN-GJL-250 ▪Impeller: EN-GJL-250 ▪Motor housing: EN-GJL-250 ▪Seal on the motor side: SiC/SiC ▪Seal on the fluid side: SiC/SiC ▪Seal, static: NBR
The precise details of the materials are shown in the respective configuration.
4.2 Monitoring devices
Overview of possible monitoring devices:
FK 17.1 FK 202 FK 34
FK 42
Motor compartment
- -
Motor winding
Motor bearings
- - o o
Sealing chamber
Internal electrode
- -
External electrode
o o - -
Key: - = not available/possible, o = optional, • = as standard
All the monitoring devices fitted must always be connected!
Monitoring of motor compartment
The motor compartment monitoring protects the motor winding from short-circuits.
The moisture is measured by an electrode.
en Product description
12 WILO SE 2017-06
Monitoring of motor winding
The thermal motor monitoring protects the motor winding from overheating. Temper­ature limiting with bimetallic strip is fitted as standard.
As an option, the temperature can also be measured with a PTC sensor. The thermal motor monitoring can also be designed as temperature control. This allows the meas­urement of two temperatures. When the low temperature is reached, an automatic re­activation can be initiated after cooling the motor. When the high temperature is reached, the unit must deactivate with reactivation lock.
Sealing chamber monitoring
▪FK 17.1, FK 202: The sealing chamber can be equipped with an external pencil elec-
trode.
▪FK 34, FK 42: This sealing chamber is equipped with an internal pencil electrode.
The electrode registers fluid ingress through the mechanical seal on the fluid side. An alarm or deactivation of the pump can therefore take place through pump control.
Monitoring of motor bearing
The thermal monitoring of the motor bearing protects the roller bearings against over­heating. Pt100 sensors are used for temperature measurement.
4.3 Operating modes
Operating mode S1: Continuous duty
The pump can operate continuously at the rated load without exceeding the permiss­ible temperature.
Operating mode: Non-immersed operation
The “non-immersed operation” operating mode describes the possibility of the motor emerging during the drainage pumping sequence. This allows a further lowering of the water level as far as the upper edge of the hydraulics. Observe the following points dur-
ing non-immersed operation: ▪Operating mode: Continuous duty (S1). ▪Max. fluid and ambient temperature: The max. ambient temperature corresponds to the
max. fluid temperature shown on the rating plate.
4.4 Operation with frequency con­verter
Operation on the frequency converter is permitted. Refer to the appendix for the relev­ant requirements!
4.5 Operation in an explosive atmo­sphere
FK 17.1 FK 202 FK 34
FK 42
ATEX approval
o - - -
FM approval
o - - -
CSA-Ex approval
- - - -
Key: - = not available/possible, o = optional, • = as standard
For use in explosive atmospheres, the pump must be marked as follows on the rating
plate: ▪“Ex” symbol of the corresponding approval ▪Ex classification
For the relevant requirements, refer to the explosion protection chapter in the ap-
pendix of these installation and operating instructions!
ATEX approval
The pumps are suitable for operation in potentially explosive areas, which require
devices belonging to group II, category 2. The pumps can be used in both zone 1 and
zone 2.
These pumps must not be used in zone 0!
FM approval
The pumps are suitable for operation in potentially explosive areas, which require
devices belonging to the protection class “Explosion proof, Class 1, Division 1”. There-
fore, operation in areas with the required protection class “Explosion proof, Class 1, Di-
vision 2” is also possible.
4.6 Rating plate
The following is an overview of the abbreviations and associated data on the rating
plate:
Product description en
Installation and operating instructions Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 13
Rating plate designation
Value
P-Typ
Pump type
M-Typ
Motor type
S/N
Serial number
Art.-No.
Article number
MFY
Date of construction (format: yyyyWww)
Q
Volume flow duty point
Q
max
Max. volume flow
H
Delivery head duty point
H
max
Max. delivery head
H
min
Min. delivery head
n
Speed
t
max
Max. fluid temperature
IP
Protection class
I
Rated current
I
ST
Starting current
I
SF
Rated current at service factor
P
1
Power consumption
P
2
Rated power
U
Rated voltage
F
Frequency
Cos φ
Motor efficiency
SF
Service factor
OT
S
Operating mode: submerged
OT
E
Operating mode: non-immersed
AT
Starting mode
IM
org
Impeller diameter: Original
IM
korr
Impeller diameter: corrected
4.7 Type key
Example: Wilo-EMU FA 30.93D + FK 34.1-6/33KEx-E3
Hydraulics type key
FA
Sewage pump
30
x10 = nominal diameter of pressure connection
93
Internal performance coefficient
D
Impeller shape: W = vortex impeller E = single-channel impeller Z = two-channel impeller D = three-channel impeller V = four-channel impeller T = closed SOLID impeller G = half open SOLID impeller
Motor type key
FK
Self-cooling motor, oil-filled
34
Size
1
Internal code figure
6
Number of poles
33
Package length in cm
K
Seal version
en Transportation and storage
14 WILO SE 2017-06
Example: Wilo-EMU FA 30.93D + FK 34.1-6/33KEx-E3
Ex
Ex-rated
E3
IE-efficiency class (derived from IEC60034‑30)
4.8 Scope of delivery
▪Pump with free cable end ▪Cable length per customer request ▪Mounted accessories, e.g. external pencil electrode, pump support foot, etc. ▪Installation and operating instructions
4.9 Accessories
▪Suspension unit ▪Pump support foot ▪Special versions with Ceram coatings or special materials ▪External pencil electrode for sealing chamber control ▪Level control devices ▪Fixation accessories and chains ▪Switchgear, relays and plugs
5 Transportation and storage
5.1 Delivery
After receiving the shipment, this must be checked immediately for defects (damage, completeness). Defects must be noted on the freight documentation! Furthermore, de­fects must be notified to the transport company or the manufacturer immediately on the day of receipt of shipment. Subsequently notified defects can no longer be asser­ted.
5.2 Transport
WARNING Standing beneath suspended loads!
Never allow anyone to stand under suspended loads! Danger of (serious) injuries caused by falling parts. Loads may not be carried over work places where people are present!
WARNING Head and foot injuries due to lack of protective equipment!
Danger of (serious) injuries during work. Wear the following protective equipment:
• Safety shoes
• Safety helmet must be used if lifting equipment are used!
NOTICE Only use lifting equipment in a technically sound condition!
Only use lifting equipment in a technically sound condition for lifting, lowering and transporting the pump. Ensure that the pump does not become jammed during lift­ing and lowering. Do not exceed the max. permissible bearing capacity of the lifting equipment!
Only remove the outer packaging at the place of utilisation to ensure that the pump is not damaged during transport. Use tear-proof plastic sacks of sufficient size to pack­age used pumps for transport in a leak-proof manner.
The following points must also be observed:
Transportation and storage en
Installation and operating instructions Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 15
P-Typ M-Typ
S/N
MFY
U Q IMø
I H OTS/E
IST Cos TPFmax
P SF
F ISF IP
N MC
P-Typ M-Typ
S/N
MFY
U Q IMø
I H OTS/E
ISTCos TPF
max
P SF
F ISF IP
N MC
Fig.2: Attachment point
▪Adhere to the applicable national safety regulations. ▪Use legally specified and approved lifting gear. ▪Select the lifting gear based on the existing conditions (weather, attachment point,
load, etc.). ▪Only attach the lifting gear to the attachment point. Fix with a shackle. ▪Use lifting equipment with sufficient bearing capacity. ▪The stability of the lifting equipment must be ensured during operation. ▪When using lifting equipment, a second person must be present to coordinate the pro-
cedure if required (e.g. if the operator’s field of vision is blocked).
5.3 Storage
DANGER Danger due to fluids hazardous to health!
If the pump is used in fluids hazardous to health, decontaminate the pump after dis­mantling and before carrying out any other work! There is danger to life! Observe the specifications in the work regulations! The operator must make sure that the per­sonnel has received and read the work regulations!
WARNING Sharp edges on the impeller and suction port
Sharp edges can form on the impeller and suction port. There is danger of limbs be­ing cut-off! Protective gloves must be worn to protect from cuts.
CAUTION Total damage due to moisture ingress
Moisture ingress in the power supply cable damages the power supply cable and the pump! Never immerse the end of the power supply cable in a fluid and firmly seal it during storage.
Newly supplied pumps can be stored for one year. Contact customer service to store
the pump for more than one year.
The following must be observed for storage: ▪Securely position the pump on a firm bearing surface. Store pumps with pump support
foot in an upright position, store pumps without pump support foot in a horizontal pos-
ition. Secure the pump against falling over and slipping! ▪The max. storage temperature is -15°C to +60°C at a max. relative humidity of 90%,
non-condensing. Frost-proof storage at a temperature of 5°C to 25°C with relative
humidity of 40% to 50% is recommended. ▪Do not store the pump in rooms in which welding work is carried out. The resulting
gases or radiation can corrode the elastomer parts and coatings. ▪Seal the suction and pressure connection tightly. ▪Protect power supply cables against kinking and damage. ▪Protect the pump from direct sunlight and heat. Extreme heat can cause damage to the
impellers and the coating! ▪Impellers must be turned by 180° at regular intervals (3–6months). This prevents
jamming of the bearings and renews the lubrication film of the mechanical seal. WARN-
ING!There is a risk of injury due to edges on the impeller and suction port!
▪Elastomer parts and the coating are subject to natural brittleness. Contact customer
service if the pump must be stored for more than 6months.
After storage, remove any dust and oil from the pump and check the coating for dam-
age. Repair damaged coatings before further use.
en Installation and electrical connection
16 WILO SE 2017-06
6 Installation and electrical con-
nection
6.1 Personnel qualifications
▪Electrical work: Electrical work must be carried out by a qualified electrician (in accord-
ance with EN50110-1).
▪Installation-/dismantling: The technician must be trained in the use of the necessary
tools and mounting materials for the relevant construction site.
6.2 Installation types
▪Vertical stationary wet well installation with suspension unit ▪Vertical portable wet well installation with pump support foot ▪Vertical stationary dry well installation ▪Horizontal stationary dry well installation
NOTICE!Horizontal installation is not possible, depending on type and performance. For this installation type, contact customer service!
6.3 Operator responsibilities
▪Observe locally applicable accident prevention and safety regulations of trade associ-
ations. ▪Observe all regulations for working with heavy loads and under suspended loads. ▪Provide protective equipment and ensure that the protective equipment is worn by
personnel. ▪Observe local sewage technology regulations for the operation of sewage systems. ▪Avoid pressure surges!
Pressure surges can occur in long discharge pipelines with steep terrain. These pressure
surges can lead to the destruction of the pump! ▪Ensure the cooling time of the motor depending on the operating conditions and the
size of the pump chamber. ▪Structural components and foundations must be of sufficient stability in order to allow
the device to be fixed securely and functionally. The operator is responsible for the pro-
vision and suitability of the structural component/foundation! ▪Check that the available consulting documents (installation plans, design of the operat-
ing space, inflow conditions) are complete and correct.
6.4 Installation
DANGER Potentially fatal danger due to dangerous autonomous work!
Work in chambers and narrow rooms as well as work involving risk of falling are dan­gerous work. Such work may not be carried out autonomously! A second person must be present for safety reasons.
WARNING Hand and foot injuries due to lack of protective equipment!
Danger of (serious) injuries during work. Wear the following protective equipment:
• Safety gloves against cuts
• Safety shoes
• Safety helmet must be used if lifting equipment are used!
NOTICE Only use lifting equipment in a technically sound condition!
Only use lifting equipment in a technically sound condition for lifting, lowering and transporting the pump. Ensure that the pump does not become jammed during lift­ing and lowering. Do not exceed the max. permissible bearing capacity of the lifting equipment!
▪Prepare operating space/installation location as follows:
– Clean, free of coarse solids
– Dry well
– Frost-free
– Decontaminated
Loading...
+ 36 hidden pages