Wilo Economy MHIL Installation And Operating Instructions Manual

Pioneering for You
Wilo-Economy MHIL
de Einbau- und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service
4 088 957-Ed.05 /2016-08-Wilo
es Instrucciones de instalación y funcionamiento it Istruzioni di montaggio, uso e manutenzione ru Инструкция по монтажу и эксплуатации
Fig. 1
Fig. 2
~1
~1
Fig. 3
Y
~3
HIGH (VOLTAGE) LOW
Fig. 4
English
1. General
Installation and service by qualified personnel only
1.1 Applications
Pumps for clear liquids in residential, agricultural, industrial, and other applications.
- Drawing of water from a well, spring, river, pond, etc. Water should not be drawn from abyssinian wells (tube, driven well).
1.2 Technical description
1.2.1 Performance and electrical data (Table 1)
Permissible temperature range –15 °C to +90 °C Maximum ambient temperature +40 °C Maximum permissible working pressure 10 bar Mains voltages: 50 Hz 60 Hz 1~230V (±10%) 1~220V (-10%) - 1~240V (+6%)
3~230/400V (±10%) 3~220/380V (-10%) - 3~265/460V (+10%)
Speed (RPM) 50 Hz 60 Hz 2900 RPM 3500 RPM
Mains fuse protection see motor rating plate
Protective system IP 54
Insulation class F
Sound pressure level 0/+3 dB(A)
Power (kW)
1~ 1~ 3~ 3~
50Hz 60Hz 50Hz 60Hz
0.55    
0.75    
1.1    
1.5    
2.2 - -  
When ordering spare parts, please give all the information on the pump/motor rating plate.
1.2.2 Series specifications
Pump family
Flow rate (m3/h) (2-pole/ 50 Hz)
Number of stages
E = gaskets EPDM V = gaskets VITON
1 = single-phase motor 3 = three-phase motor
Mains voltage (V) Frequency (Hz) 2 poles Manufacturer’s key IE3 motor
MHIL 3 02 E - 1 - 230 - 50 - 2 / XX/X - IE3
Connection diameters
Models
Tapped port ND
Suction Discharge MHIL100 1” - (26-34) 1” - (26-34)
MHIL300 1” - (26-34) 1” - (26-34)
MHIL500 1”
 1”
1/4
- (33-42) 1” - (26-34)
1/2
 1”
1/4
- (33-42)
10 WILO SE 04/2016