Willtek
4032
STABILOCK Communications
Test System
Built-in spectrum analyzer
AUTORUN
IEEE-488 interface
High-speed measurements
Reliability
Willtek STABILOCK 4032
In excess of 5000 STABILOCK 4032 radio test sets are currently in use worldwide. This success has been due to the versatile design, simple operation and wide variety of system tests which can be made with the “universal” test set.
Applications range from high-speed production tests and quality measurements to servicing and commissioning tests. The wide variety of hardware modules and software options covering frequency ranges up to 2.3 GHz, provide comprehensive capability of analog and digital cellular, cordless and two-way radio systems.
Additional capability includes base station measurements and paging tests.
Systems include TETRA Digital Trunked Radio, Tetrapol as well as CDMA base station testing at 800 MHz and
1900 MHz. The GSM Option of the STABILOCK 4032 now is also capable of testing dual-band mobiles.
Please refer to individual data sheets for further details of system performance.
Typical performance is derived from the standard deviation of many hundreds of production units operating under normal environmental conditions of 20°C.
Built-in spectrum analyzer
Detailed spectrum analysis from 2 MHz to 1 GHz (standard) or up to 2.3 GHz (optional). Additional option for highspeed sweep and a host of useful functions.
AUTORUN
Simple, BASIC-oriented programming language for fully automated tests. Ready-written programs are available for all popular mobile telephone systems.
IEEE-488 interface
Fitted as standard. Ensures remote control via controller or program downloads from LAN servers.
High-speed measurements
Special firmware for final testing during production cuts measuring times by around 30%.
Reliability
All subassemblies are burnt-in tested, with plug-in modules and SMD technology.
Generator (Typical Performance)
Level error |
(< –15 dBm, RF socket, |
|
f = 1 to 1000 MHz) |
Level error (FEX) |
(< –20 dBm, RF socket, |
|
f = 1000 to 2000 MHz) |
|
|
< 0.3 dB
[1.3 dB]
<0.3 dB
[ 1.3 dB]
Analzyer (Typical Performance)
RF power measuring error |
(20 to 500 MHz, broadband) |
|
4% [ |
10%] |
RF power measuring error |
(800 to 920 MHz, broadband) |
|
5% [ |
12%] |
|
|
|
|
|
Audio Generator and Analyzer (Typical Performance) |
|
|
||
|
|
|
|
|
AF generator distortion |
(f > 3kHz) |
|
< 0.6% [ |
1.0%] |
AF volmeter measuring error |
(f = 300 Hz to 3 kHz) |
|
< 1% [ |
3.0%] |
|
|
|
|
|
Specifications below apply for the basic 4032 up to 999.99 MHz. When the FEX (Frequency Extension) option is fitted please see * section at the end. Please refer to individual data sheets for performance of options.
2
Willtek STABILOCK 4032
AM measurement |
|
|
Frequency range |
|
2 to 999.9999 MHz |
Measuring range |
|
0 to 100 % |
Input level |
|
|
RF socket |
|
1 mW to 125 W |
RF DIRECT socket |
|
0.01 mW to 0.5 W |
Resolution |
|
0.1% |
Measuring accuracy (m |
10%) |
|
fmod = 200 Hz to 10 kHz |
10% ±2 digits |
|
Demodulation distortion |
|
|
fmod = 300 Hz to 3 kHz |
< 1% |
|
Modulation frequency |
DC to 10 kHz |
|
Spurious-modulation measurement |
||
Input level |
|
|
RF socket |
|
1 mW to 125 W |
RF DIRECT socket |
|
20 mV to 1 V |
Measuring range |
0 to –40 dB (CCITT-weighted) |
|
|
|
referred to 3 kHz FM dev., |
|
|
3 rad M dev. or 30% AM |
Measuring accuracy |
|
1 dB |
AF Generator
Modulation generator GEN A |
|
|
Frequency range |
30 Hz to 30 kHz |
|
Resolution |
|
|
f < 3 kHz |
0.1 Hz |
|
f 3 kHz |
1 Hz |
|
Frequency error |
< 0.01% |
|
Level range (EMF) |
0.1 mVrms to 5 Vrms |
|
Resolution |
|
|
EMF |
5 V |
10 mV |
EMF |
1 V |
1 mV |
EMF |
0.1 V |
0.1 mV |
EMF |
10 mV |
10 V |
Level error |
|
|
f = 100 Hz to 10 kHz |
< 3% |
|
f = 30 Hz to 30 kHz |
< 10% |
|
Distortion |
|
|
f = 30 Hz to 3 kHz |
< 0.5% |
|
f > 3 kHz |
< 1% |
|
Output impedance (balanced) |
|
|
f = 300 Hz to 3 kHz |
< 10 |
|
f = 30 Hz to 30 kHz |
< 40 |
|
Output impedance |
|
|
(unbalanced) |
600 ±5% |
|
Permissible load impedance |
> 200 |
AF Analyzer
AF voltmeter
Frequency range
30 Hz to 30 kHz or to CCITT P 53A |
|
Measuring range |
0.1 mV to 20 V |
Resolution |
|
Level < 0.1 V |
0.1 mV |
Level < 1 V |
1 mV |
Level < 10 V |
10 mV |
Level < 20 V |
100 mV |
Measuring accuracy |
|
f = 300 Hz to 3 kHz |
3% |
f = 50 Hz to 15 kHz |
6% |
Source impedance |
> 100 k or 600 ±3% |
Input capacitance |
20 pF |
AF counter |
|
Frequency range |
30 Hz to 30 kHz |
Input level |
5 mV to 20 V |
Resolution |
|
f < 300 Hz |
0.1 Hz |
f < 10 kHz |
1 Hz |
f 10 kHz |
10 Hz |
Measuring accuracy |
0.01% ±1 digit |
Distortion meter |
|
Input level |
0.1 to 20 V |
Test frequency |
1 kHz ±5 Hz |
Measuring range |
0 to 99% |
Resolution |
0.1% |
Measuring accuracy |
|
d = 1 to 90% |
5% of meas. value ±3 digits |
SINAD meter |
|
Input level |
0.1 to 20 V |
Measuring range |
1 to 46 dB |
Resolution |
|
SINAD < 30 dB |
0.1 dB |
SINAD 30 dB |
0.5 dB |
Measuring accuracy for SINAD < 30 dB
0.8 dB ±1 digit
Scope & Analyzer
Spectrum analyzer |
|
|
Frequency range |
2 to 999.9999 MHz |
|
Frequency accuracy |
|
|
better than 2% of sweep width |
||
Input level range for measuring accuracy 3 dB |
||
in the frequency range 0.5 × fc |
f 2 × fc |
|
RF socket |
|
–70 to +47 dBm |
RF DIRECT socket |
|
–90 to +13 dBm |
Sweep width |
200 kHz, 2 MHz, 10 MHz |
|
Sweep time |
|
|
Sweep width 2 MHz and 10 MHz |
approx. 500 ms |
|
Sweep width 200 kHz |
|
approx. 2 s |
Evaluation bandwidth |
|
|
Sweep width 2 MHz and 10 MHz |
30 kHz |
|
Sweep width 200 kHz |
|
6 kHz |
Inherent noise on RF DIRECT socket |
||
Sweep width 2 MHz and 10 MHz |
–95 dBm |
|
Sweep width 200 kHz |
|
–105 dBm |
Oscilloscope |
|
Inputs external |
Zi = 1 M /40 pF (AC/DC) |
Inputs internal RX mod, TX demod, duplex demod, AF voltmeter, residual distortion
Frequency range |
DC (3 Hz) to 20 kHz |
|
Level error |
< 10% + 0.2 div |
|
Grating |
6 x 10 div |
|
Horizontal deflection |
100 s/div to 500 |
s/div |
Vertical deflection |
2 mV/div to 10 V/div or |
|
|
160 Hz/div to 8 kHz/div (FM) |
|
|
0.16 rad/div to 8 rad/div ( |
M) |
|
0.8 %/div to 40 %/div (AM) |
|
Trigger |
± slope selectable trigger level |
|
Operating modes |
auto, norm, one-shot, freeze, |
|
time measurement (max. resolution 2.5 s) |
Selective-call encoder and decoder
Standard tone sequences |
|
|
ZVEI 1 |
CCIR |
VDEW |
ZVEI 2 |
EEA |
NATEL |
EIA |
EURO |
CCITT |
User-defined tone sequences
Sequence of up to 30 tones can be stored by user. Also double tones and underlying continuous tone (with GEN B option).
Encoder
Operating modes
Single-tone sequence (max. 30 tones). Double-tone sequence (with GEN B option) (singletone and double-tone sequences can be transmitted continuously).
Acknowledgement call (max. 15 double tones) from response time of < 100 ms acknowledgement call only possible with optional duplex FM/ M stage
Frequency error |
1 × 10– Hz |
Decoder
Decoding of each tone of tone sequences
(max. 30 tones). Continuous decoding can be set.
4