Design Excellence : Cool Technology
Jade Range
Model: JC2SA. JC3SA & JC4SA - Datasheet
Key Features
• Foodsafe stainless steel exterior, stainless steel interior base with radiused corners to reduce potential dirt traps and aluminium walls for hygiene and durability
• Integral ‘easy grab’ door handle ­easy to clean with no potential dirt traps
• CoolSmart controller is designed for easy operation and features clear digital display
• Designed and engineered to operate efficiently up to a 43°C ambient, this exceeds Climate Class 5
• Self closing doors minimises temperature gain, reducing energy consumption
• Precision injected, high density polyurethane insulation. Provides excellent thermal efficiency with low GWP (Global Warming Potential) and zero ODP (Ozone Depletion Potential)
• Heavy duty, non-marking swivel castors with brakes – designed to fit through a standard door for ease of positioning
• Barrel locked doors for added security
• Easy to clean and replace magnetic balloon door gaskets with 100% tight seal to prevent heat loss
• Removable refrigeration system designed for easy service and maintenance
• Fitted with 2 1/1GN nylon coated wire shelves per section as standard or trayslides to accommodate 2/1GN containers
• Removable racking system for flexibility and ease of cleaning
• Anti-tilt trayslides
• Fully automatic air cooled condensing unit
• Defrost water is vaporised using
recycled heat from compressor
• Can be connected to a Williams
temperature monitoring TAB system
• High performance helium leak testing to guarantee system efficiency
Options
• Stainless steel interior
• Additional shelving / trayslides
• Drawer banks (2 or 3)
• Raised pan holder
• Screw on splash-back
• Adjustable legs in lieu of castors (add 10mm)
• Hydrocarbon version available
• Glycol Secondary System
• Wells - full / standard / special
HJC2SA +1/+4°C
MJC2SA -2/+2°C
LJC2SA -18/-22°C
HJC3SA +1/+4°C
MJC3SA -2/+2°C
LJC3SA -18/-22°C
HJC4SA +1/+4°C
MJC4SA -2/+2°C
Variant
Temp Storage
General Produce
Meat
Frozen Food
General Produce
Meat
Frozen Food
General Produce
Meat
Dimensions
Important Information
Allow minimum of 500mm above cabinet for maintenance and ventilation. All refrigeration equipment requires adequate ventilation for efficient and effective performance.Williams are committed to a policy continuing product development and innovation and as such, we reserve the right to change product specifications stated without prior notice. V7 - July 2010
Bryggen Road, North Lynn Industrial Estate
King’s Lynn, Norfolk PE30 2HZ
T +44 (0) 1553 817000 F +44 (0) 1553 817111
Spares+44 (0)1553 817017
E info@williams-refrigeration.co.uk
W www.williams-refrigeration.com
H860 W1370 D659
H600 W390 D560
D1090
H965 W1470 D750
115kg
External (mm):
Internal (mm):
w = per section
Door Opening (mm):
Packed:
Weight:
Add 5kg per product for packaging
HJC2
H860 W1370 D659
H600 W390 D560
D1090
H965 W1470 D750
115kg
H860 W1370 D659
H600 W390 D560
D1090
H965 W1470 D750
120kg
H860 W1835 D659
H600 W390 D560
D1090
H965 W1935 D750
140kg
H860 W1835 D659
H600 W390 D560
D1090
H965 W1935 D750
140kg
H860 W1835 D659
H600 W390 D560
D1090
H965 W1935 D750
145kg
H860 W2300 D659
H600 W390 D560
D1090
H960 W2400 D750
150kg
H860 W2300 D659
H600 W390 D560
D1090
H960 W2400 D750
150kg
MJC2 LJC2 HJC3 MJC3 LJC3 HJC4 MJC4
12.5 / 354
0.7mm stainless steel
0.7mm aluminium
0.7mm stainless steel ext.
0.7mm aluminium int.
220V/240V 50Hz/1Ph 13 amp plug
10.7 amps
3.0 amps
1/4
3.2kW in 24hrs
561 watts
R134a
Automatic off cycle
75mm 50mm (sides)
51 dBA
4 x 1/1 GN
2 pairs of slides per door
Capacity: cu.ft/litres
Construction
Exterior
Interior
Door
Power Supply
Power Input
Start Up Running
Compressor HP
Energy Consumption
(Tested to EN153)
Heat Rejection
(Evaporating at -10°C in 32°C ambient)
Refrigerant
Defrost
Insulation
ODP Zero Polyurethane
Noise Output
Fittings
Shelves
Trayslides
HJC2
12.5 / 354
0.7mm stainless steel
0.7mm aluminium
0.7mm stainless steel ext.
0.7mm aluminium int.
220V/240V 50Hz/1Ph 13 amp plug
10.7 amps
3.0 amps
1/4
4.3kW in 24hrs
561 watts
R134a
Automatic electric door mullion heaters
75mm 50mm (sides)
51 dBA
4 x 1/1 GN
2 pairs of slides per door
12.5 / 354
0.7mm stainless steel
0.7mm aluminium
0.7mm stainless steel ext.
0.7mm aluminium int.
220V/240V 50Hz/1Ph 13 amp plug
22.7 amps
4.0 amps
1/2
10.2kW in 24hrs
736 watts
R404a
Automatic electric door mullion heaters
75mm 50mm (sides)
52.5 dBA
4 x 1/1 GN
2 pairs of slides per door
18 / 510
0.7mm stainless steel
0.7mm aluminium
0.7mm stainless steel ext.
0.7mm aluminium int.
220V/240V 50Hz/1Ph 13 amp plug
15.3 amps
3.5 amps
1/3
4.4kW in 24hrs
665 watts
R134a
Automatic off
cycle
75mm 50mm (sides)
51. dBA
6 x 1/1 GN
2 pairs of slides per door
18 / 510
0.7mm stainless steel
0.7mm aluminium
0.7mm stainless steel ext.
0.7mm aluminium int.
220V/240V 50Hz/1Ph 13 amp plug
15.3 amps
3.5 amps
1/3
5.3kW in 24hrs
665 watts
R134a
Automatic electric door mullion heaters
75mm 50mm (sides)
51 dBA
6 x 1/1 GN
2 pairs of slides per door
18 / 510
0.7mm stainless steel
0.7mm aluminium
0.7mm stainless steel ext.
0.7mm aluminium int.
220V/240V 50Hz/1Ph 13 amp plug
22.7 amps
4.5 amps
1/2
11.4kW in 24hrs
1223 watts
R404a
Automatic electric door mullion heaters
75mm 50mm (sides)
52.5 dBA
6 x 1/1 GN
2 pairs of slides per door
24 / 670
0.7mm stainless steel
0.7mm aluminium
0.7mm stainless steel ext.
0.7mm aluminium int.
220V/240V 50Hz/1Ph 13 amp plug
15.3 amps
3.5 amps
1/3
6.1kW in 24hrs
665 watts
R134a
Automatic off cycle
75mm 50mm (sides
51.0 dBA
8 x 1/1 GN
2 pairs of slides per door
24 / 670
0.7mm stainless steel
0.7mm aluminium
0.7mm stainless steel ext.
0.7mm aluminium int.
220V/240V 50Hz/1Ph 13 amp plug
15.3 amps
3.5 amps
1/3
7.2kW in 24hrs
665 watts
R134a
Automatic electric door mullion heaters
75mm 50mm (sides
51.0 dBA
8 x 1/1 GN
2 pairs of slides per door
MJC2 LJC2 HJC3 MJC3 LJC3 HJC4 MJC4