Williams Ref PW4 User Manual

Page 1
Design Excellence : Cool Technology
PW4 Prep Well
Model: PW4 - Datasheet
Key Features
Foodsafe stainless steel exterior and
•
Designed to accommodate 1/3 and
•
1/6 GN containers in pan holders
•
Includes space saving worktop / chopping board
•
Environmentally sound Hydrocarbon refrigerant has a low GWP / zero ODP, energy consumption is reduced by 15% due to its excellent thermodynamic properties
CoolSmart controller is designed for
•
easy operation and features clear digital display
•
Designed and engineered to operate efficiently up to a 32°C ambient, this exceeds Climate Class 4
Precision injected, high density
•
30mm polyurethane insulation. Provides excellent thermal efficiency with low GWP (Global Warming Potential) and zero ODP (Ozone Depletion Potential)
Heavy duty, non-marking swivel
•
castors with brakes for mobility and ease of positioning
•
High performance, efficient commercial refrigeration system for increased energy efficiency and quieter improved performance
•
Designed to prolong preparation periods by reducing the temperature rise of ingredients whilst the lid is removed
•
Unique air flow design with protective 1°C air curtain ensures food temperature in pans is maintained at between 1°C to 4°C, when the cutting board / worktop is in place
•
Removable, easy to clean worktop / chopping board, crumb tray and lift off night cover
Removable internal fittings including
•
pan supports for easy cleaning and hygiene
Designed for positioning next to
•
existing wall benches and tables
769mm
Variant
PW4 +1/+4°C
Temp Storage
General Produce
Options
• 1/3 x 150mm Gastronorm pans
• 1/6 x 150mm Gastronorm pans
450mm
Page 2
Dimensions
External (mm):
PW4
xcluding lid (882mm including lid)
H870 e W450 D769
Internal (mm):
Door Opening (mm):
Packed:
Weight:
Add 5kg per product for packaging
Important Information
Capacity:1/3or1/6pans
Construction
Exterior
Interior
Door
Power Supply
H179 W305 D709
N/A
H902 W470 D790
60kg
PW4
4 x1/3or 8 x1/6pans
0.7mm stainless
steel
0.6mm tainless
s steel
0.7mm
stainless steel
220V/240V 50Hz/1Ph
13 amp plug
Power Input
Start Up
Running
Compressor HP
Energy Consumption
(Tested to EN153) in 24hrs
7 amps
1.2 amps
1/5
3kW
Heat Rejection
(Evaporating at -10°C
in 32°C ambient)
Refrigerant
Defrost
Insulation
ODP Zero Polyurethane
498watts
R290
Hot gas defrost
30mm
Fittings
1
/6Pans (not included)
1
/3Pans (not included)
Cutting Board
8
4
Bryggen Road, North Lynn Industrial Estate
King’s Lynn, Norfolk PE30 2HZ
T +44 (0) 1553 817000
F +44 (0) 1553 817111
Spares +44 (0)1553 817017
All refrigeration equipment requires adequate ventilation for efficienct and effective performance. Williams are committed to a policy continuing product development and innovation and as such, we reserve the right to change product specifications stated without prior notice. V2 - October 2011
W www.williams-refrigeration.com