Williams Ref HJ2SA, HJ2 User Manual

Jade Range
Model: J1SA & J2SA - Datasheet
Design Excellence : Cool Technology
D824mm
H1960mm
W737mm
Key Features
• Foodsafe stainless steel exterior, stainless steel interior base with radiused corners to reduce potential dirt traps and aluminium walls for hygiene and durability
• Full length integral ‘easy grab’ door handle - easy to clean with no potential dirt traps
• CoolSmart controller is designed for easy operation and features clear digital display
• Designed and engineered to operate efficiently up to a 43°C ambient, this exceeds Climate Class 5
• Self closing doors minimises temperature gain, reducing energy consumption
• Precision injected, high density 75mm polyurethane insulation. Provides excellent thermal efficiency with low GWP (Global Warming Potential) and zero ODP (Ozone Depletion Potential)
• Heavy duty, non-marking swivel castors with brakes – designed to fit through a standard door for ease of positioning
• Barrel locked doors for added security
W1400mm
• Easy to clean and replace magnetic balloon door gaskets with 100% tight seal to prevent heat loss
• Top mounted removable refrigeration system designed for easy service and maintenance
• Fitted with 3 2/1GN nylon coated wire shelves per section as standard or trayslides to accommodate 2/1GN containers
• Removable racking system for flexibility and ease of cleaning
• Anti-tilt trayslides
• Fully automatic air cooled condensing unit
• Defrost water is vaporised using
recycled heat from compressor
• Can be connected to a Williams
temperature monitoring TAB system
• High performance helium leak testing to guarantee system efficiency
Variant
HJ1SA +1/+4°C
MJ1SA -2/+2°C
LJ1SA -18/-22°C
HJ2SA +1/+4°C
MJ2SA -2/+2°C
LJ2SA -18/-22°C
Temp Storage
General Produce
Frozen Food
General Produce
Frozen Food
Options
• Stainless steel interior
• Additional shelving / trayslides
• Glass door (high temp only)
• Left hand door hang
• Adjustable legs in lieu of castors (add 10mm)
• Hydrocarbon version available
• Glycol Secondary System
Meat
Meat
Dimensions
HJ1 MJ1 LJ1 HJ2 MJ2 LJ2
External (mm): H1960 H1960 H1960 H1960 H1960 H1960
W737 W737 W737 W1400 W1400 W1400 D824 D824 D824 D824 D824 D824
Internal (mm): H1370 H1370 H1370 H1370 H1370 H1370
W587 W587 W587 W1250 W1250 W1250 D683 D683 D683 D683 D683 D683
Door Opening (mm): D1520 D1520 D1520 D1520 D1520 D1520
Packed: H2070 H2070 H2070 H2070 H2070 H2070
W837 W837 W837 W1500 W1500 W1500 D924 D924 D924 D924 D924 D924
Weight: 137kg 137kg 142kg 164kg 164kg 169kg Add 5kg per product for packing
Important Information
HJ1 MJ1 LJ1 HJ2 MJ2 LJ2
Capacity: cu.ft/litres 21.5/611 21.5/611 21.5/611 45.5/1288 45.5/1288 45.5/1288
Construction
Exterior 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm
stainless steel stainless steel stainless steel stainless steel stainless steel stainless steel
Interior 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm
aluminium aluminium aluminium aluminium aluminium aluminium
Door 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm
stainless steel ext. stainless steel ext. stainless steel ext. stainless steel ext. stainless steel ext. stainless steel ext.
0.7mm 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm aluminium int. aluminium int. aluminium int. aluminium int. aluminium int. aluminium int.
Power Supply 220V/240V 220V/240V 220V/240V 220V/240V 220V/240V 220V/240V
50Hz/1Ph 50Hz/1Ph 50Hz/1Ph 50Hz/1Ph 50Hz/1Ph 50Hz/1Ph 13 amp plug 13 amp plug 13 amp plug 13 amp plug 13 amp plug 13 amp plug
Power Input
Start Up 10.7 amps 10.7 amps 22.7 amps 15.3 amps 15.3 amps 29.7 amps Running 3.0 amps 3.0 amps 4.0 amps 3.5 amps 3.5 amps 4.5 amps
Compressor HP 1/4 1/4 1/2 1/3 1/3 3/4
Energy Consumption 3.0kW in 24hrs 4.1kW in 24hrs 9.0kW in 24hrs 4.9kW in 24hrs 5.6kW in 24hrs 11.0kW in 24hrs
(Tested to EN153)
Heat Rejection
(Evaporating at -10°C in 32°C ambient) 565 watts 565 watts 1427 watts 665 watts 665 watts 3142 watts
Refrigerant R134a R134a R404a R134a R134a R404a
Defrost Automatic off cycle Automatic electric Automatic electric Automatic off cycle Automatic electric Automatic electric
Door mullion Door mullion Door mullion Door mullion heaters heaters heaters heaters
Insulation 75 mm 75 mm 75 mm 75 mm 75 mm 75 mm ODP Zero Polyurethane
Noise Output 58 dBa 58 dBa 60 dBa 61 dBa 61 dBa 65 dBa
Fittings
Shelves 3 x 2/1GN 3 x 2/1GN 3 x 2/1GN 6 x 2/1GN 6 x 2/1GN 6 x 2/1GN
(W530xD650) (W530xD650) (W530xD650) (W530xD650) (W530xD650) (W530xD650)
Trayslides 66612 12 12
Bryggen Road, North Lynn Industrial Estate
King’s Lynn, Norfolk PE30 2HZ
T +44 (0) 1553 817000 F +44 (0) 1553 817111
Spares+44 (0)1553 817017
E sales@williams-refrigeration.co.uk
Allow minimum of 500mm above cabinet for maintenance and ventilation. All refrigeration equipment requires adequate ventilation for efficient and effective performance.Williams are committed to a policy continuing product development and innovation and as such, we reserve the right to change product specifications stated without prior notice. V7 - May 2011
W www.williams-refrigeration.co.uk
Loading...