INSTALLATION
Removal of Redundant Cabinets
Please ensure the old / redundant cabinet and refrigeration equipment are disposed of safely and legally. It is
recommended that doors are removed prior to disposal in order to ensure safety.
Unpacking
Remove all external and interior packing and accessories. Ensure all such material is disposed of safely.
Ventilation
It is essential to ensure that the room in which the unit is to be installed has adequate ventilation. Refrigerators generate
a considerable amount of heat and, if operated in a small unventilated room in warm weather, they will quickly cause the room
temperature to become excessive. This could cause the motor to overheat and possibly damage the windings. At the very
least, such an installation will cause the unit to use an excessive amount of electricity. A single door unit usually generates
1200W of heat and a two door version - 1800W (these figures are approximate).
In addition to ventilation in a room, please ensure that cabinets with top-mounted systems have 500mm clearance
between the cabinet top and ceiling for engineer access and ventilation, with 50mm clearance provided around the unit
to ensure efficient and effective performance. Do not block vents by stacking boxes on top or in front of the unit as this
could affect performance.
Castors
The cabinet should stand level to ensure correct operation of self-closing doors and proper drainage of condensate
from the evaporator.
Models fitted with castors and non-adjustable, therefore a level platform / floor should be provided where unit is to be
located. Where swivel and brake castors are fitted and when unit has been positioned, please ensure brakes have
been activated by pressing metal bar down. Remember to release brakes before trying to move unit.
Mains Connection
The unit comes fitted with a moulded plug for safety and must be earthed. If plug or cable should fail, please contact
the spares office on +44 (0) 1553 817017 for a replacement.
If the cabinet has been laid on its back or tipped, DO NOT switch on immediately. Leave in an upright position
for at least 1 hour before switching on.
Connection to Main Drains
The Overnight Thaw requires connection to a main drain with a standard 1 1/2” fitting.
Shelf/Slide Fitting
When positioning the slides present the slide to the racking by holding it in the opposite hand to the side of the
cabinet you are installing the slides. Offer the slide at a 45° angle as shown in Figure 1. Once in place let slide drop
into position creating a horizontal ledge on which the shelves will sit.
Shelf Weight Distribution
Before loading, allow cabinet to reach normal operating temperature.
When loading the unit, please ensure that load is equally distributed throughout and ensure air can circulate around
and through stored products. Ensure all items are covered and that raw and cooked foods are stored separately.
Fig. 1