Dimensions
Front Loading - 30” Entry 1 Rack 2 Rack 3 Rack 4 Rack 6 Rack 8 Rack
External (mm): H2580 H2580 H2580 H2580 H2580 H2580
W1200 W1200 W1200 W1200 W2500 W2500
D1000 D1500 D2000 D2500 D2000 D2750
Internal (mm): H2000 H2000 H2000 H2000 H2000 H2000
W869 W869 W869 W869 W2210 W2210
D747 D1247 D1756 D2256 D1780 D2530
Door Opening (mm): D1995 D2495 D2995 D3495 D2995 D3745
Front Loading - 18” Entry 2 Rack 4 Rack 6 Rack 8 Rack
External (mm): H2580 H2580 H2580 H2580 H2580 H2580
W965 W965 W1000 W1000 W2000 W2000
D1200 D2000 D3000 D3750 D3000 D3750
Internal (mm): H2000 H2000 H2000 H2000 H2000 H2000
W634 W634 W710 W710 W1710 W1710
D1200 D1747 D2700 D3452 D2720 D3470
Door Opening (mm): D1970 D2770 D3770 D4520 D3770 D4520
Important Information
1 Rack 2 Rack 3 Rack 4 Rack 6 Rack 8 Rack
Capacity:
1 x 20 tier trolley 2 x 20 tier trolley 3 x 20 tier trolley 4 x 20 tier trolley 6 x 20 tier trolley 8 x 20 tier trolley
Construction
Exterior 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm
stainless steel stainless steel stainless steel stainless steel stainless steel stainless steel
Interior 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm
stainless steel stainless steel stainless steel stainless steel stainless steel stainless steel
Door 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm
stainless steel ext. stainless steel ext. stainless steel ext. stainless steel ext. stainless steel ext. stainless steel ext.
0.7mm 0.7mm 0.7mm 0.7mm 0.7mm 0.7mm
stainless steel stainless steel stainless steel stainless steel stainless steel stainless steel
Power Supply 400V/415V 400V/415V 400V/415V 400V/415V 400V/415V 400V/415V
50Hz/3Ph 50Hz/3Ph 50Hz/3Ph 50Hz/3Ph 50Hz/3Ph 50Hz/3Ph
Power Input
Running 13 amps 13 amps 18 amps 19 amps 31 amps 37 amps
Compressor HP 1/2 1 1 1/4 2 2 1/2 3
Heat Rejection
(Evaporating at -10°C
in 32°C ambient) 565 watts 565 watts 1564 watts 737 watts 737 watts 2931 watts
Refrigerant R134a R134a R404a /R134a R134a /R404a R404a R404a
Defrost Automatic Automatic Automatic Automatic Automatic Automatic
electric electric electric electric electric electric
Insulation 90 mm 90 mm 90 mm 90 mm 90 mm 90 mm
ODP Zero Polyurethane
Noise Output 58 dBa 58 dBa 60 dBa 61 dBa 61 dBa 65 dBa
Allow minimum of 500mm above cabinet for maintenance and ventilation. All refrigeration equipment requires
adequate ventilation for efficient and effective performance.Williams are committed to a policy continuing product
development and innovation and as such, we reserve the right to change product specifications stated without prior notice. V3 - August 2010
Bryggen Road, North Lynn Industrial Estate
King’s Lynn, Norfolk PE30 2HZ
T +44 (0) 1553 817000
F +44 (0) 1553 817111
Spares +44 (0)1553 817017
E info@williams-refrigeration.co.uk
W www.williams-refrigeration.com