Wilkerson Instrument DR4302 Operating Manual

DR4302
DC INPUT
DUAL OUTPUT
ISOLATED TRANSMITTER
DIN RAIL MOUNT
DESCRIPTION
The DR4302 provides two individually isolated DC current outputs proportional to a DC voltage or current input. The input and output are ranged at the factory, but Zero and Span controls provide
±15% adjustability. The DR4302 provides 3 way
isolation between input, output, and power source.
The isolation makes the product useful for measuring input signals with high common mode voltages and for breaking ground connections to eliminate ground loops. It can also be used for signal conversion and scaling as well.
The screw terminal blocks plug into the case, which allows easy wiring and removal of products.
All of the DR Series of products provide transient protection to help eliminate damage from lightning and from other transients coupled onto the power and signal leads by system wiring.
INSTALLATION
The DR Series of products mount on standard 35 mm DIN rails. Install by hooking the top of the case’s latch onto the top of the DIN rail. Then push down on the case, letting it pivot on the DIN rail. The bottom slide of the mount will snap behind the rail and secure the product.
To remove, insert a screwdriver into the hole on the metal latch on the bottom of the case, and pull the latch down until it allows the front of the case to be lifted up.
WARRANTY
The DR4302 Series of products carry a limited 3 year warranty. In the event of a failure due to defective material or workmanship, the unit will be repaired or replaced at no charge.
CALIBRATION
The DR4302 is factory calibrated to the input and output noted on the case side label. Terminal connections are shown on the front label. To make field adjustments to the product:
1. Remove the circuit board from the case by squeezing the 2 locking tabs (see diagram below) and pulling the case front, with the circuit board, out of the case.
2. Connect a calibrator to the input terminals.
3. Connect an accurate voltmeter or current meter to the Output 1 terminals.
4. Apply power to the unit.
5. Set the input for its zero scale and adjust the Zero control for
zero scale output.
6. Set the input for its full scale and adjust the Span control for
full scale output.
7. Repeat once or twice until no further adjustment is required.
8. Repeat steps 3 through 7 for Output 2.
1 2
SPECIFICATIONS
INPUT RANGE
Voltage 1/5 V, 0/10 V
Current
0/1 mA, 0/20 mA 4/20 mA, 10/50 mA
INPUT IMPEDANCE
Voltage
600 kilohms
Current Current Input Input Shunt
Value
0/1 mA
0/20 mA
4/20 mA
10/50 mA
OUTPUT
Current
4/20 mA Compliance > 12 V Per Output at 24 V Power
1000 OHM
100 OHM 125 OHM
20 OHM
CASE DIMENSIONS INCHES [mm]
BANDWIDTH
-3db at 3 Hz OUTPUT RIPPLE
(peak to peak)
<0.1% of span
ACCURACY ±0.1% of span
LINEARITY ±0.05% of span
COMMON MODE REJECTION
100 dB, DC to 60 Hz
ISOLATION, OUTPUT/INPUT/POWER
>500 megohms 1000 VPeak
OPERATING TEMPERATURE
14°F to 158°F/-10°C to 70°C
TEMPERATURE STABILITY
±(0.01% of span)/°C max
POWER
21 to 28 VDC, 60 mA max
TWO-WIRE TRANSMITTER WIRING
In installations where isolation between the power supply and the input
terminals is not required, the DR Series power supply can also be used to power a Two-Wire Transmitter (see drawing below). If isolation is required, a separate power supply must be used to power the Two-Wire Transmitter.
3
Specifications Are Subject To Change Without Notice. © 2007 Wilkerson Instrument Co., Inc. DWG#W103853 3/07