Wilbur Curtis TLP61 User Manual

FIND OUT MORE
THE WEB.
ON
WILBURCURTIS.COM
Installation Instructions, Service & Warranty Information
MODELS INCLUDEDMODELS INCLUDED
MODELS INCLUDED
MODELS INCLUDEDMODELS INCLUDED
••
• TLP10
••
••
• TLP15
••
••
• TLP20
••
••
• TLP30*
••
••
• TLP61
•• * 30 is Not UL Listed
UU
U
UU
LL
L
LL
®®
®
®®
C
ISO 9001 REGISTERED
UU
U
UU
®®
®
®®
TLP DIGITAL AIRPOT BREWER
LL
L
LL
FOR THE LATEST SPEC INFORMATION GO TO WWW.WILBURCURTIS.COM
WILBUR CURTIS COMPANY Montebello, CA 90640
DRAFT COPY
Not Released. This Version Exists as File No.
I:\DIAGRAMS\FRANK\FX-134.p65
TT
ABLEABLE
T
ABLE
TT
ABLEABLE
OFOF
OF
OFOF CONTENTSCONTENTS
CONTENTS
CONTENTSCONTENTS
Important Safeguards / Conventions . . . . . . . . . . . . . . . . . . . . . . . .
Contents & Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rough-in Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Quick Start & Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Brewing Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Brew Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Brew Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Brew Cycle Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low Temperature Brew “Delta” Lockout . . . . . . . . . . . . . . . . . . .
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Temp Reset Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Care & Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Schematics
TLP10/12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLP15/17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLP20/22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLP30/32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLP61/63 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Illustrated Parts Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Illustrated Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 – 17
2 3 3 4 5 6 6 7 7 8
9 10 10
11 12 13 14 15
18 19
IMPOR IMPOR
IMPOR
IMPOR IMPOR SAFEGUARDS/SAFEGUARDS/
SAFEGUARDS/
SAFEGUARDS/SAFEGUARDS/ CONVENTIONSCONVENTIONS
CONVENTIONS
CONVENTIONSCONVENTIONS
TT
ANTANT
T
ANT
TT
ANTANT
This appliance is designed for commercial use. Any servicing other than cleaning and maintenance should be performed by an authorized Wilbur Curtis service center.
Do NOT immerse the unit in water or any other liquid
To reduce the risk of fire or electric shock, do NOT open top or side panel.
There are no user serviceable parts located inside. Repair should be done only by authorized service personnel.
Keep hands and other items away from hot parts of the appliance during operation.
Never clean with scouring powders or harsh implements (see Care & Maintenance, page 10).
CONVENTIONSCONVENTIONS
CONVENTIONS
CONVENTIONSCONVENTIONS
WW
ARNINGS - ARNINGS -
W
ARNINGS -
WW
ARNINGS - ARNINGS -
IMPORIMPOR
IMPOR
IMPORIMPOR
SANITSANIT
SANIT
SANITSANIT
TT
ANT NOTES/CAUTIONS - FROM ANT NOTES/CAUTIONS - FROM
T
ANT NOTES/CAUTIONS - FROM
TT
ANT NOTES/CAUTIONS - FROM ANT NOTES/CAUTIONS - FROM
AA
TION REQUIREMENTSTION REQUIREMENTS
A
TION REQUIREMENTS
AA
TION REQUIREMENTSTION REQUIREMENTS
TO HELP TO HELP
TO HELP
TO HELP TO HELP
AA
VOID PERSONAL INJURVOID PERSONAL INJUR
A
VOID PERSONAL INJUR
AA
VOID PERSONAL INJURVOID PERSONAL INJUR
THE FTHE F
THE F
THE FTHE F
YY
Y
YY
ACTORACTOR
ACTOR
ACTORACTOR
YY
Y
YY
2
CONTENTS AND UNPACKING
SHIPPING CARTON CONTENTS & UNPACKING
UNPACKING
All products manufactured by the Wilbur Curtis Company are thoroughly inspected at the factory and are warranted to be free of all defects and faulty workmanship. These brewers are packaged for maximum protection during shipping. Make sure the shipping carton is not damaged or punctured. Unpack the carton, carefully inspecting the contents for any damage that may have occurred in transit.
STANDARD ITEMS
Qty Item Part Nº
Coffee Brewer, ThermoLogic Low Profile
1
Brew Cone
1
Elbow, ¼ x ? Flare
1
Paper Filters
25
Service Manual, TLP
1
3
8
TLP
WC-3621 WC-2401
CR-10 F-3206
ROUGH-IN DRAWINGS
TLP10 Model Only
2¼"
1
1 "
7
6 "
8
7
17 "
8
8
16½"
7
17 "
8
13¼"
11¾"
BREW SETUP HALF BREW, 1.1 LITER FULL BREW, 2.2 LITERS
CORD & PLUG 6 Ft./NEMA 5-15P (120V Units Only)
WATER HOOK-UP ELBOW, FLARE 1/4 x 3/8 FITTING, WATER CONNECTION
9"
7½"
6½"
TOP VIEW
ELECTRICAL
VoltsTLP Model Nº Watts Amps Hertz
TLP10
TLP20
TLP15
TLP30
TLP61
120V
120V
220V
220V
120/220V
1700W
1500W
3600W
3600W
1700/3600W
14A
12.5A
16.5A
16.5A
14/16.5A
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
2W+G
2W+G
3W+G
2W+G
2W/3W+G
2"
Wires
3
QUICK START & SET-UP
Your Curtis ADS System is Factory Pre-Set and Ready to Go... Right from the Carton.
Following are the Factory Settings for the TLP Coffee Brewer:
Brew Temperature = 200°F
Brew Volume = Set to dispensing vessel requirements (2.2 Liters) Generally there will never be a reason to change your ADS programming. However, should you need to make slight adjustments to meet your brewing needs, programming instructions are provided later in this manual.
SYSTEM REQUIREMENTS
• Water Source
20 - 100 PSI (Minimum Flow Rate of 1 GPM)
CAUTION: DO NOT connect this brewer to hot water. The inlet valve is not rated for hot water.
• Electrical
See attached schematic for your model.
This equipment is to be installed to comply with the applicable federal, state, or local plumbing and electrical codes having jurisdiction.
SETUP STEPS
The unit should be level (left to right and front to back), located on a solid counter top. Connect a water line from the water filter to the brewer. (NOTE: Some type of water filtration device must be used to maintain a trouble-free operation). In areas with extremely hard water, we suggest that a sedimentary and taste & odor filter be installed. These will prolong the life of your brewing system and enhance coffee quality.
The National Sanitation Foundation requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine can be
moved for cleaning underneath.
2. In some areas an approved backflow prevention device may be required between the brewer and the
water supply. (Check local plumbing codes)
1. A ¼ flare water inlet fitting has been supplied for water line connection. Use tubing sized sufficiently to provide a minimum of 1.0 GPM,
2. Connect the unit to an appropriate electrical power circuit.
3. Turn on the toggle (STANDBY/ON) switch behind the unit. The heating tank will start to fill. When the water level in the tank rises to the correct volume, the heating elements will ener­gize automatically. With ADS Systems there is no danger of element burnout caused by an empty tank.
4. Turn on the control panel by pressing the ON/OFF button.
5. The heating tank will require 20 to 30 minutes to reach operating temperature (200°F) as indicated by the READY-TO-BREW indicator.
6. Prior to brewing, dispense 12 ounces of hot water through the hot water faucet.
7. Run brew cycle of at least 16 ounces to purge the water line of any air that may be trapped in the lines after filling.
4
BREWING INSTRUCTIONS
WW
ARNING:ARNING:
W
ARNING: To avoid
WW
ARNING:ARNING: scalding, do NOT remove brew cone while brew indicator light is flashing.
1. Brewer should be ON (Confirm rear toggle switch is on, then press ON/ OFF button).
2. Place an empty airpot in position, under the sprayhead.
3. Place a filter and ground coffee in the brewcone. Slide the brewcone into position on brew rails.
4. Wait until the READY-TO-BREW light comes on and then press the desired BREW button. The indicator light above the selected brew will begin flashing when the brewcycle starts.
IMPORTANT: The brewcycle is adjusted at the factory to fill a standard 2.5 liter airpot with
2.2 liters of brewed coffee. The duration of the brewcycle is set between 2 minutes, 40 seconds and 3 minutes.
5
STEPS TO PROGRAMMING
Your Curtis ADS System is Factory Pre-Set for Optimum Per­formance. Generally, There Will Not be a Need to Change Programming.
READY TO BREW Indicator Light (Red)
ON/OFF Button (Yellow)
Changing the ADS System Program
WARNING: These steps will involve working with hot water. Scalding may occur if care is not taken against spilling.
ENTERING THE PROGRAM MODE
For ALL functions you must first enter the programming mode.
Turn OFF the power from the Control Panel by pressing .
Press and HOLD and press and RELEASE .
MODE #1
Continue HOLDING until starts blinking; RELEASE.
READY TO BREW
Your ADS System features a dynamic memory. In the event of a power loss, it will remember ALL program settings.
Brew Temperature - Factory Pre-set to 200º F
This programming function allows you to set brew temperature from 170º to 204ºF. Brew temperature will be indicated by the READY TO BREW light blinking (see chart). Simply follow the steps indicated.
I/O
ON/OFFON/OFF
ON/OFF
ON/OFFON/OFF
I/O
ON/OFFON/OFF
ON/OFF
ON/OFFON/OFF
I/O
ON/OFF
FULL BREW Button (Green)
HOT WATER Dispense Button (Orange)
READY TO BREW
FULL BREW
HALF BREW
~~~
HOT
WATER
HALF BREW Button (Green)
CONFIRM/RESET BREW TEMPERATURE - Factory Preset to 200º
ENTER THE PROGRAMMING MODE #1:
Press for two seconds, then RELEASE.
will start blinking. Each blink equals 2º F, starting at 170º (max.
READY TO BREW
temp. 204º F or 18 blinks).
To change Temperature, press and HOLD .
Temperature Table
No. of
Blinks Temp.
170ºF
1
172ºF
2
174ºF
3
176ºF
4
178ºF
5
180ºF
6
182ºF
7
184ºF
8
186ºF
9
* Factory Setting
6
No. of
Blinks Temp.
10 11 12 13 14 15 16 17 18
188ºF 190ºF 192ºF 194ºF 196ºF 198ºF
200ºF*
202ºF 204ºF
will start QUICK flashing. Each QUICK flash equals 2º F.
READY TO BREW
After reaching 204º, temperature starts over at 170º.
RELEASE when the desired temperature is reached. The newly set
temperature will now be displayed. To set and exit, press .
I/O
ON/OFFON/OFF
ON/OFF
ON/OFFON/OFF
Brew Volume - Factory Pre-set Full Brew to 2.2 Liters
The Half Brew button is always half of the brewtime of the setting of the Full Brew button. You cannot program the Half Brew. Change the brew volume of your ADS System by following these steps.
Before changing the brew volume, wait until unit reaches brew temperature (Ready to Brew light comes on), insert the brewcone into place on the brewer, then place a measuring container centered beneath the brewcone.
ENTER THE PROGRAM MODE
For ALL functions you must first enter the programming mode.
Turn OFF the power from the Control Panel by pressing .
Press and HOLD and press and RELEASE .
MODE #1
Continue HOLDING until starts blinking; RELEASE.
READY TO BREW
I/O
ON/OFFON/OFF
ON/OFF
ON/OFFON/OFF
I/O
ON/OFFON/OFF
ON/OFF
ON/OFFON/OFF
(When programming the brewer for volume, it is important to realize that after you program the unit, it must reach full brew temperature before it will allow you to brew.)
Brew Cycle Counter
This function allows you to see exactly how many brew cycles occurred on the system. This feature is ideal for preventive maintenance programs (i.e., changing water filters, cleaning the sprayhead, etc.) and determining profitability. To view the number of brew cycles on the unit, follow these steps:
ENTER THE PROGRAM MODE
For ALL functions you must first enter the programming mode.
I/O
ON/OFFON/OFF
ON/OFF
ON/OFFON/OFF
I/O
ON/OFFON/OFF
ON/OFF
ON/OFFON/OFF
Turn OFF the power from the Control Panel by pressing .
Press and HOLD and press and RELEASE .
MODE #2
Continue HOLDING until STOPS blinking; RELEASE.
READY TO BREW
CHANGE BREW VOLUME - Factory Preset to Brewer Requirements
ENTER THE PROGRAMMING MODE #1: (CAUTION: Be sure to have brewcone and vessel in position).
Press and HOLD until hot water starts running; then RELEASE.
When desired volume is reached, press again to stop flow.
To set and exit, press .
I/O
ON/OFFON/OFF
ON/OFF
ON/OFFON/OFF
TO ACCESS BREW CYCLE COUNTER
ENTER THE PROGRAMMING MODE #2:
will now start a pattern of LONG and SHORT blinks.
READY TO BREW
This pattern identifies the number of brew cycles. SHORT blinks indicate the brew number from one [1] to nine [9]. LONG blinks separate the 1’s, 10’s, 1,000’s and 10,000’s.
BREW COUNT EXAMPLE
Sets Pattern Factor
1st
2nd 3rd
4th 5th
Total Brews
1’s
10’s
100’s
1,000’s
10,000’s
Total
4
20
300
1,000
0
01,324
7
Low Temperature Brew Lockout (Delta) - Factory Preset to Delta 1
DELTA 1 (this is factory setting) allows you to brew within 5 degrees from set tempera-
ture. This provides for consistent brew temperature and consistent water density. If Delta 1 is used, run half brew first, discard water. Program to ½" below collar of airpot (one small finger width).
DELTA 2 allows you to brew within 10 degrees from set temperature. If Delta 2 is used, run half brew first and discard water. Program to ¾" below collar of airpot (between one and two small finger widths).
DELTA 3 will allow you to brew at any temperature. Back to back brewing is only possible in this mode (120V). If Delta 3 is used, run half brew first and discard water. Program to 1” below collar of airpot (two small finger widths). The brew cone must be empty without a filter. This will ensure proper operation at all brew rates. During back to back brew cycles the water temperature in the tank will start to drop, as these brew cycles increase the water gets cooler. With cooler water in the tank the density changes and the flow rate will increase. Typically an increased flow rate may translate in to a maximum increase of 4 ounces in the airpot.
ENTERING THE PROGRAM MODE
For ALL functions you must first enter the programming mode.
I/O
ON/OFFON/OFF
ON/OFF
ON/OFFON/OFF
I/O
ON/OFFON/OFF
ON/OFF
ON/OFFON/OFF
Turn OFF the power from the Control Panel by pressing .
Press and HOLD and press and RELEASE .
MODE #3
Continue HOLDING until stops blinking and REMAINS ON. RELEASE.
Release will blink a pattern of flashes from one to three.
READY TO BREW
READY TO BREW
CHANGING THE DELTA FEATURE
ENTER THE PROGRAMMING MODE #3:
Press and HOLD until shows one quick flash, then
RELEASE. You have now added a blink to your blinking light pattern.
By pressing and holding you add another blink.
Example 1: has two blinks and you want to remove the temperature
Example 2: has three blinks and you want to go back to Delta 1
To set and exit, press .
READY TO BREW
limitation entirely, press and hold for one more blink. Now you can brew at Delta 3.
READY TO BREW
setting. Press and HOLD for one more blink. Now you can brew at Delta 1.
I/O
ON/OFFON/OFF
ON/OFF
ON/OFFON/OFF
READY TO BREW
8
TROUBLE­SHOOTING GUIDE
IMPORIMPOR
TT
IMPOR
IMPORIMPOR
Error codes are indicated by the red READY TO BREW light. If and Error Code occurs, the unit will shut down all functions including heating, water inlet, water delivery. confirm Error Code three times.
ANTANT
T
ANT
TT
ANTANT
ALWAYS
ERROR CODES
Curtis ADS Systems contain various safety features in the electronic circuitry that will shut down the functions of the unit in the event of systems faiolures. Error codes are signalled by the red READY-TO-BREW light blinking.
::
:
::
INTERPRETING THE CODES
ADS ERROR CODESADS ERROR CODES
ADS ERROR CODES
ADS ERROR CODESADS ERROR CODES
ADS technology features a state-of-the-art error code system. This is designed to quickly advise you of any problems the system may experience expediting service or repair. Occasionally, an error reported may be a problem with the water supply or electrical power; NOT directly associated with a fault of the Curtis system itself. An example of this includes a clogged water filter — indicated by a water level error code.
Error Codes are indicated by blinking. = Long Flash = Short Flash
The code pattern is as follows:
Error Codes are reset by turning the rear toggle switch to Standby for a minimum of 10 seconds, then returning the switch to ON. Any service required for your Curtis system must be performed by a qualified service technician.
READY TO BREW
WATER LEVEL PROBLEM
TEMPERATURE PROBLEM
SYMPTOM:SYMPTOM:
SYMPTOM:
SYMPTOM:SYMPTOM:
POSSIBLE CAUSE SOLUTION
1. Water line has been turned OFF
2. Insufficient Water Supply; Water Line Pinched
3. Clogged Water Filter
4. Defective Inlet Valve
5. Grounded Probe
6. Defective Control Board
SYMPTOM:SYMPTOM:
SYMPTOM:
SYMPTOM:SYMPTOM:
POSSIBLE CAUSE SOLUTION
7. Defective Water Inlet Valve
8. Limed-Up Probe
9. Non-grounded or loose terminal connections at control board or tank.
10. Defective Control Board.
WW
AA
TER DOES NOT FLOW INTO HEATER DOES NOT FLOW INTO HEA
W
A
TER DOES NOT FLOW INTO HEA
WW
AA
TER DOES NOT FLOW INTO HEATER DOES NOT FLOW INTO HEA
WW
AA
W
A
WW
AA
TER HEATER HEA
TER HEA
TER HEATER HEA
TING TING
TT
ANK OVERFLOWINGANK OVERFLOWING
TING
T
ANK OVERFLOWING
TING TING
TT
ANK OVERFLOWINGANK OVERFLOWING
Turn ON Water Line; confirm unit is turned on and water is flowing into heating tank. Straighten Wafer Line; confirm unit is turned on and water is flowing into heating tank. Replace filter; confirm unit is turned on and water is flowing into heating tank. Contact Factory. Contact Factory. Contact Factory.
Turn power off and observe tank water level. If water continues to flow Inlet Valve must be cleaned, rebuilt or replaced.
Clean and/or replace. The control board must be securely grounded for proper operation.
Check for loose connections at the terminals.
Contact Factory
TING TING
TING
TING TING
TT
ANKANK
T
ANK
TT
ANKANK
Water Level
ERROR CODE
Water Level
ERROR CODE
IMPORTANT: Heating function may be SHUT DOWN due to Water Level Error Code.
SYMPTOM:SYMPTOM:
SYMPTOM:
SYMPTOM:SYMPTOM: WW
AA
TER TER
W
A
TER
WW
AA
TER TER
POSSIBLE CAUSE SOLUTION
11. Defective or Loose Heat Sensor
12. Defective Heating Element
13. Defective Control Board
WW
AA
TER IN HEATER IN HEA
W
A
TER IN HEA
WW
AA
TER IN HEATER IN HEA
TEMPERATEMPERA
TEMPERA
TEMPERATEMPERA
TING TING
TING
TING TING
TURE LOWTURE LOW
TURE LOW
TURE LOWTURE LOW
TT
ANK DOES NOT GET HOTANK DOES NOT GET HOT
T
ANK DOES NOT GET HOT
TT
ANK DOES NOT GET HOTANK DOES NOT GET HOT
Make sure there is a layer of silicone paste (Part No WC-5231) between the sensor and tank body. The fastening nut should be securely tightened, making a good connection. Check wire for damage. Contact factory. Contact factory.
;;
;
;;
Temp Sensor
ERROR CODE
9
SYMPTOM:SYMPTOM:
SYMPTOM:
SYMPTOM:SYMPTOM:
POSSIBLE CAUSE SOLUTION
14. Obstructed Sprayhead
15. Water level is too low in heating
16. Defective Pump
17. Defective Control Board
tank
WW
AA
TER NOT FLOWING FROM SPRATER NOT FLOWING FROM SPRA
W
A
TER NOT FLOWING FROM SPRA
WW
AA
TER NOT FLOWING FROM SPRATER NOT FLOWING FROM SPRA
Remove and inspect sprayhead. Clean and reinstall. Check water level in tank. If water is not flowing into tank, review steps 1 through 4. Contact factory. Contact factory.
YHEADYHEAD
YHEAD
YHEADYHEAD
Water Level
ERROR CODE
HIGH TEMP THERMOSTAT
WARNING: Turn off all power to unit before removing side panel to reset the thermostat.
SYMPTOM:SYMPTOM:
SYMPTOM:
SYMPTOM:SYMPTOM:
POSSIBLE CAUSE SOLUTION
18. Temperature set too high for
19. Loose or defective heat sensor
20. Defective triac
21. Defective control board
elevation
WW
AA
TER IN HEATER IN HEA
W
A
TER IN HEA
WW
AA
TER IN HEATER IN HEA
TING TING
TING
TING TING
TT
ANK OVERHEAANK OVERHEA
T
ANK OVERHEA
TT
ANK OVERHEAANK OVERHEA
Re-program to lower temperature.
Contact factory. Contact factory. Contact factory.
TINGTING
TING
TINGTING
Temp Sensor
ERROR CODE
HIGH TEMPERATURE RESET THERMOSTAT
The High Temperature Reset Thermostat (p/n WC-523) protects the unit by cutting off power in the event of an overheated condition. This may be caused by a low water level. When this occurs, the heating element may be exposed, causing an excessively HOT condition. Power will be cut off by the reset thermostat, indicated when the red reset button pops out. When the high temperature condition has been corrected and after the temperature drops, reset the thermostat by pushing in the red button. You can find the reset thermostat, located on the heating tank.
CARE & MAINTENANCE
CAUTION: Do not use cleansers, liquid bleach , powders or any other substance containing chlorine. These products will promote corrosion and will pit stainless steel. USE OF
THESE PRODUCTS WILL VOID YOUR WARRANTY.
10
PREVENTIVE MAINTENANCE OF TLP
1. Remove the sprayhead from brewer and clean it once a week; more often in heavy lime areas.
2. Inside of the heating tank may occasionally require removing of lime build-up. The frequency is determined by local water conditions.
CLEANING
Daily cleaning of the external parts of the unit will maintain the appearance of the TLP and improve the flavor of the coffee.
1. Wipe off any spills, dust or debris that may fall on exterior surfaces.
2. Slide out the brew cone and rinse.
3. Clean sprayhead and dome around the sprayhead. Use a non-toxic cleaner.
4. Clean the brew cone slide rails with a brush or damp cloth. Dry thoroughly.
NOTE - On stainless steel units clean the outside surfaces with stainless steel polish. This is to prevent scratching of the stainless steel surfaces.
ELECTRICAL SCHEMATIC
Brewer Model TLP10 & TLP12
1/31/00 9.1 I:Diagrams\Fx-134.p65.p12
11
ELECTRICAL SCHEMATIC
Brewer Model TLP15 & TLP17
12
ELECTRICAL SCHEMATIC
Brewer Model TLP20 & TLP22
13
ELECTRICAL SCHEMATIC
Brewer Model TLP30 & TLP32
14
ELECTRICAL SCHEMATIC
Brewer Model TLP61 & TLP63
15
PARTS DIAGRAMS
2
1
3
6
5
15
7
12
13
11
16
17
9
10
A
16
8
A
PARTS DIAGRAMS
20
24
19
18
21
23
22
B
B
4
14
17
PARTS LIST GENERAL PARTS
ITEM ITEM
NN
ºº
PART PART
ITEM
N
ITEM ITEM
1 WC-3621 CONE, UNIVERSAL BREW 7 1/8 BLK PLASTIC 1A WC-3316 BREWCONE W/BASKET, S/S STD 7 1/8 2 WC-5450 COVER, TOP 3 WC-39321 MEMBRANE, CONTROL PANEL CURTIS 4 WC-1438-101 SENSOR, TEMPERATURE TANK 5 WC-29030 SPRAYHEAD ASSY, ADVANCED FLOW ORANGE 6 WC-2962 FITTING, SPRAYHEAD ASSY 7 WC-29037 RESTRICTOR, ELBOW PP RED 8 WC-3765 KIT, INLET VALVE REPAIR (FOR WC-826, WC-856) 9 WC-58085 COVER, SIDE 10 WC-8556 HEATSINK ASSY 11 WC- 761 CONTROL BOARD, 120V TLP (Models 10, 20, 15, 61) 11A WC- 771 CONTROL BOARD, 220V TLP (Model 30) 12 WC-1040 PUMP, WATER CENTRIFUGAL 120V 60 Hz (Models 10, 20, 15, 61) 12A WC-1042 PUMP, WATER CENTRIFUGAL 220V 60 Hz (Model 30) 13 WC- 889 VALVE, LIQUID DISPENSING LEFT 120V 12W (Models 10, 20, 15, 61) 13A WC- 860 VALVE, LIQUID DISPENSING LEFT 220VAC 12W (MODEL 30) 14 WC-5231 COMPOUND, SILICONE 5 OZ TUBE 15 WC-3503 LEG, SCREW BUMPER 3/8” - 16 STUD 16 WC- 102 SWITCH, TOGGLE SPST 25A 250VAC RESISTIVE (Models 10, 20) 16A WC- 103 SWITCH, TOGGLE DPST 25A 125/250 VAC RESISTIVE (Models 15, 30, 61) 17 WC- 826 VALVE INLET 1.15 GPM 120V 10W (Models 10, 20, 15, 61) 17A WC- 856 VALVE, INLET 1.15 GPM 240V 10W (Model 30) 18 WC-54107 TANK, COMPLETE W/1600W HEATER (Model 10) 18A WC-54123 TANK, COMPLETE W/1450W HEATER (Model 20) 18B WC-54124 TANK, COMPLETE W/3500W HEATER (Models 15 & 30) 18C WC-54127 TANK, COMPLETE W/1600W AND 3500W HEATER (Model 61) 19 WC-43062 GASKET, TANK LID 20 WC-5851 COVER, TANK W/NOTCHES 21 WC-5502 PROBE ASSY, WATER LEVEL 22 WC- 523 THERMOSTAT, MANUAL RESET 120/220 VAC 25A 220 DEG F MAX 23 WC- 904 ELEMENT, HEATING 1,600W 120V (Model 10 & 61) 23A WC- 917 ELEMENT, HEATING 1,450W 120V (Model 20) 23B WC- 922 ELEMENT, HEATING 3,500W 220V (Models 15, 30 & 61) 24 WC-5310 TUBE, 5/16 ID x 1/8W SILICONE
25 WC-8591 CAPACITOR, X2
º
NN
ºº
PART
PART PART
NN
N
NN
ºº
DESCRIPTIONDESCRIPTION
º
DESCRIPTION
ºº
DESCRIPTIONDESCRIPTION
18
WARRANTY We hereby certify that the products manufactured by the Wilbur Curtis Company, Inc., are, to the
best of our knowledge, free from all defects and faulty workmanship. The following warranties and conditions are applicable:
90 Days for Labor and 1 Year Parts from Date of Purchase from Factory: This warranty covers all electrical parts, fittings and tubing.
40 Months or 40, 000 Pounds of Coffee on a set of Grinding Burrs. (ADS Grinders)
• 2 Years from Date of Purchase: This warranty covers electronic control boards and leaking or pitting of a stainless steel body of a Brewer or Urn.
90 Days from Date of Purchase: On replacement parts that have been installed on out of warranty equipment
All in-warranty service calls must have prior authorization from the manufacturer. For an RMA (Return Merchandise Authorization) number, call the Technical Service Department at 1-800-995-0417. The Wilbur Curtis Company will allow up to 100 miles, round trip, per in-warranty service call.
CONDITIONS & EXCEPTIONS
The warranty covers original equipment at time of purchase only. The Wilbur Curtis Company, Inc., assumes no responsibility for substitute replacement parts installed on Curtis equipment that have not been purchased from the Wilbur Curtis Company. Inc The Wilbur Curtis Company will not accept any responsibility if the following conditions are not met. The warranty does not cover and is void under these circumstances:
1) Improper operation of equipment. The equipment must be used for its designed and intended purpose and function.
2) Improper installation of equipment. This equipment must be installed by a professional, certified technician and must comply with all local electrical, mechanical and plumbing codes.
3) Wilbur Curtis Company will not be responsible for the operation of equipment at other than the stated voltages on the serial plate.
4) Abuse or neglect (including failure to periodically clean or remove lime accumulations). Manufacturer is not responsible for variation in equipment operation due to excessive lime or local water conditions.
5) Replacement of items subject to normal use and wear. This shall include, but is not limited to, light bulbs, shear disks, “0” rings, gaskets, canister assemblies. whipper chambers and plates, mixing bowls, agitation assemblies and whipper propellers.
6) Any faults resulting from inadequate water supply. This includes, but is not limited to, excessive or low water pressure, and inadequate or fluctuating water flow rate.
7) All repairs and/or replacements are subject to our decision that the workmanship or parts were faulty and the defects showed up under normal use.
8) All labor shall be performed during regular working hours. Overtime charges are the responsibility of the owner.
9) Charges incurred by delays, waiting time, or operating restrictions that hinder the service technician’s ability to perform service is the responsibility of the owner of the equipment. This includes institutional and correctional facilities.
10) All claims under this warranty must be submitted to the Wilbur Curtis Company Technical Service Department before return of the unit to the factory.
11) All equipment returned to us must be repackaged properly in the original carton. No units will be accepted if they are damaged in transit due to improper packaging.
12) Damaged in transit.
13) The resetting of safety thermostats and circuit breakers, programming and temperature adjustments are the responsibility of the equipment owner.
NO UNITS OR PARTS WILL BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION (RMA). RMA NUMBER MUST BE MARKED ON THE CARTON OR SHIPPING LABEL.
All in-warranty service calls must be performed by an authorized service center, where service is
available. Call the factory for location near you.
19
4/3/01 ecn 4180 RevA 5/29/01 ecn 4283 RevB
WILBUR CURTIS CO., INC.
6913 Acco St., Montebello, CA 90640-5403 U.S.A. Phone: 800/421-6150 (M-F 5:30A - 4:00P PST) Fax: 323-837-2410
Technical Support Phone: 800/995-0417 E-Mail: techsupport@wilburcurtis.com
Web Site: www.wilburcurtis.com
Printed in U.S.A. 8/03 F-3206 rev C
FOR THE LATEST SPEC INFORMATION GO TO WWW.WILBURCURTIS.COM
Loading...